Professional Documents
Culture Documents
P102658-IDM-AER-400000-DWG-Z-301680-01.C02-Details HML
P102658-IDM-AER-400000-DWG-Z-301680-01.C02-Details HML
Exceptional risks relating to the works associated with this drawing are identified below.
Construction
No specific risks identified
BOLLARD FILLED WITH The above information is offered as guidance and assumes works are carried out by competent parties working where applicable
35N/MM2 CONCRETE INFILL to an appropriate Method Statements. The list of Risks/Hazards is not exhaustive and reference should be made to the relevant
CDM Risk Assessment documentation and Pre-Construction information.
REV:
01.C02 BOLLARD FILLED WITH GENERAL NOTES
35N/MM2 CONCRETE INFILL
REV: © 2022 IDOM
01.C02
1. This drawing has been prepared for the use of IDOM's client. It may not be used, modified, reproduced or relied
FOR HML FOUNDATION DETAILS 150mm Ø X 8mm HOLLOW STEEL BOLLARD, HOT upon by third parties except as agreed by IDOM or as required by law. IDOM accepts no responsibility and
REFER TO DRAWING DIPPED, GALVANISED, ETCH PRIMED. denies any liability whatsoever to any party that uses and relies on this drawing without IDOM's written consent.
P102658-IDM-AER-400000-DWG-Z-301690 PAINTED AND PRIMED GREY
2. The use of any proprietary products shown on this drawing or in any associated specifications is based solely on
1000 the data made available to IDOM by the manufacturer and/or supplier, and IDOM has made no detailed check
900 900 of the proprietary aspects of that product which remain the sole liability of the manufacturer and/or product
PROPOSED BOLLARD SET IN supplier. All proprietary products must be installed in accordance with the manufacturer's requirements.
EARTHING PIT 1200 500 X 500 X 500mm BASE WITH MIN
POWER SUPPLY 50N/mm2 NON SHRINK GROUT. 3. If this drawing has been received electronically it is the recipient's responsibility to print the document to the
JOINT JOINT
correct scale.
4. Do not scale from this drawing. Use dimensions where provided on this and related plans, sections and details.
500
Varies
5. All dimensions are in metres unless stated otherwise.
6. This drawing is to be read in conjunction with all other relevant drawings and specifications.
Varies 50mm BLINDING
UNDER PAD BASE 7. Existing infrastructure is based on an amalgamation/combination of; topographical surveys, aerial surveys,
partially completed services investigations, historical record drawings, design drawings and as-built drawings
Varies provided by LLA, in varying states of readiness and reliability.
500
8. No liability is accepted by IDOM for any discrepancy, omission or deviation and the actual existing infrastructure
must be verified and established on site by the contractor before the commencement of the works.
9. Design is based, on EASA-CS-ADR-DSN (European Aviation Safety Agency - certification specifications and
guidance material for aerodromes design) Issue 6 as instructed by LLA. Other requirements have been applied
PROTECTION BOLLARD REV:
as instructed or approved by LLA.
500 SCALE 1:25 01.C02
Dimension in mm.
NOTES
1V:1H 300
1. High mast lighting to be installed in accordance to manufacturer’s instructions.
REV:
01.C02
SECTION 30000
HIGH MAST LAYOUT
SCALE 1:25
Dimension in mm.
3152
EARTHING PIT - PT205
REV: 300x300mm
01.C02
1 x 50 Ø
1000mm
CLEARANCE MIN.
3000mm LUMINAIRE
CRADLE CLEARANCE TO EARTHING PIT
REV: Consultant:
01.C02 POWER SUPPLY
1000mm RYEBRIDGE
CLEARANCE MIN. BOLLARD FILLED WITH Unit 4, Barratt Industrial Park, Airport Way
POWER SUPPLY 35N/MM2 CONCRETE INFILL LU2 9NH Luton
Phone +44 158 245 15 25
www.ryebridgeconstruction.com
EARTHING PIT
Consulting, Engineering,
REV: 300 Architecture
01.C02 Av. Monasterio de El Escorial, 4
BOLLARD FILLED WITH 28049 Madrid (Spain)
35N/MM2 CONCRETE INFILL Phone +34 91 444 11 50
www.idom.com
HIGH MAST LIGHTING FOR HML FOUNDATION DETAILS PROJECT CURIUM PHASE 2
SCALE 1:25 REFER TO DRAWING
Dimension in mm. P102658-IDM-AER-400000-DWG-Z-301690 1100 STAGE 4 DESIGN
Drawing Title:
High Mast Lighting & FEGP
SECTION C-C SHOWING GENERAL ARRANGEMENT Standard Details - HML Infrastructure
SCALE 1:25
Dimension in mm.