1.Subject
Information on Inmarsat-C/mini-C new software release for improvement of data error of internal GPS.
2.Objective Equipment
(1) Objective Equipment: JUE-85 / 87 / 95SA / 95VM / 95LT
(2) Objective EME: Current EME (NAF-253GM / NAF-253SA / NAF-253VM / NAF-253LT)
(3) Objective internal GPS: CCA-600 (EME manufactured until around June 2017 is object.)
Serial numbers of EME (NAF-253 series) equipped with CCA-600 are as follows.
JUE-87 EME serial numbers: GR52440 or earlier (Repair serial numbers: GR92483 or earlier)
JUE-85 EME serial numbers: (Repair serial Numbers: GR92408 or earlier)
JUE-95SA EME serial numbers: GR49741 or earlier (Repair serial numbers: GR92103 or earlier)
JUE-95VM EME serial numbers: GR52630 or earlier (Repair serial numbers: GR92508 or earlier)
JUE-95LT EME serial numbers: GR49781 or earlier (Repair serial numbers: GR92096 or earlier)
* The EME (NAF-253 series) serial numbers shipped for repair is the number after GR90000.
* JUE-85 EME (NAF-253 series) is shipped for repair only.
Note: In case of the confirmation work of EME serial number is difficult, refer to the IME Serial number for
approximate reference as IME serial number GR62000 or earlier is object.
3. Outlines
3.1 Information
(1) Internal GPS (CCA-600) installed in current EME (NAF-253 series) might have a symptom (false rollover)
that is similar to rollover that the date information becomes past date before 19.6 years, in rare cases.
In this case, scheduled transmission function might terminate or messages containing incorrect date / time
/ location information would be sent in Distress alert, SSAS message and position reporting, etc.
Therefore, new ACSE software for Inmarsat-C/mini-C JUE-85 / 87 / 95SA / 95VM / 95LT which improves
this false rollover have been released.
(2) If the internal GPS installed in the EME (NAF-253 series) is CCA-700JZ, no correspondence is required.
And if EME is NAF-741GM or NAF-742SA / VM / LT, no correspondence is also required.
JQS-2170 X 様式 4(2/2)
3.2 Countermeasures
(1) Confirm the model type of internal GPS installed in EME (NAF-253 series). (See the attachment 4.)
* Since JUE-85 / 87 has a display, users can check the model type of internal GPS.
* The standard configuration of the JUE-95 series is not equipped with a display, so a service engineer
must bring a PC and visit the ship to check the model type of internal GPS.
(2) If the CCA-600 is installed, please update to the new software in accordance with the following tables.
Please note that the function does not correctly work unless the following software version combination.
4.Attached document
(1) JUE-85 / 87 /95SA / 95VM / 95LT Software Version List (Attachment1)
(2) JUE-87 Software Update Procedure (Attachment2)
(3) JUE-85/95series with NAF-253’s ACSE Software Update Procedure (Attachment3)
(4) Confirmation Procedure of Internal GPS Type (Attachment4)
(5) Inmarsat-C JUE-87 Maintenance record (Attachment5)
(6) Inmarsat-C JUE-85 Maintenance record (Attachment6)
(7) Inmarsat-C JUE-95SA / VM / LT Maintenance record (Attachment7)
Attachment1
Functional addition for IMO Res. MSC. 431 (98) (EGC message external output function and
7 2.00 2.02 Bridge Alert Management (BAM) function), Remote Software Update function
(Software combination: ACSE 2.02 / MODEM 11.0 / IME 2.00 / DTE 2.01)
Change for the compatibility to new FROM due to discontinuation of FROM production. (INM-
C function itself has not changed.)
5 1.00 1.14
(Software combination : ACSE 1.14/MODEM 11.0/IME 1.02/DTE 1.13 or 1.14)
SSAS real, SSAS test and the scheduled multiple transmission function are improved.
4 1.00 1.13
(Software combination : ACSE 1.13/MODEM 11.0/IME 1.02/DTE 1.13)
Support of optional apparatus (RDB/SB/DMC) for common use type (Partil Release)
2 1.00 1.05
(Software combination : ACSE 1.05/MODEM 11.0/IME 1.02/DTE 1.05)
Initial release
1 1.00 1.02 (Software combination : ACSE 1.02/MODEM 11.0/IME 1.01/DTE 1.01)
Functional addition for IMO Res. MSC. 431 (98) (EGC message external output function and
3 2.00 2.00
Bridge Alert Management (BAM) function), Remote Software Update function
2 1.00 1.02 Support of optional apparatus (RDB/SB/DMC) for common use type
1 1.00 1.01 Initial release
Functional addition for IMO Res. MSC. 431 (98) (EGC message external output function and
6 2.00 2.01
Bridge Alert Management (BAM) function), Remote Software Update function
Change for the compatibility to new FROM due to discontinuation of FROM production. (INM-
5 1.00 1.14
C function itself has not changed.)
Export/Import function of all EME's setting data is improved. (If “Network type” of the
4 1.00 1.13 scheduled transmission No.1 to No.5 is setup as “E-mail”, all EME's setting data cannot be
carried out Export/Import function correctly.)
2 1.00 1.05 Support of optional apparatus (RDB/SB/DMC) for common use type (Partial Release)
DTE Recovery Software (NTF-318) (This software is used for recovery when NTF-318 cannot startup.)
Maintenance
No. Software Version Modification
Number
5 2.00 2.01 DTE recovery software for DTE software Ver2.01
4 1.00 1.13 DTE recovery software for DTE software Ver1.13
3 1.00 1.12 DTE recovery software for DTE software Ver1.12
2 1.00 1.05 DTE recovery software for DTE software Ver1.05 (Not Release)
1 1.00 1.01 DTE recovery software for DTE software Ver1.01
1
Attachment1
(1) Function addition that the printer connection error window is deleted after
“Esc” key is pressed
(2) Function addition that the “Now printing” window is deleted after “Esc” key is
pressed
(3) Changed the name from “Closed network id selection” to “dnid seleCtion”
2 11.00 11.03 (4) Improvement of “Closed network id selection (DNID selection)” window format
(5) Changed the name from “Closed network list” to “DNID list”
(6) Addition of “Polling program information” window
(7) Function addition that window data is printed out manually in “DNID
selection” window and in “Polling program information” window
2
Attachment1
3
Attachment1
4
Attachment1
5
Attachment2
1. Outline
This manual explains update procedure of Inmarsat-C JUE-87 software.
2. Preparation
EME
(NAF-253GM)
Coaxial Cable
(CFQ-5922A)
EME
IME DC POWER
EXT PSU
(NTF-318) (NBD-904)
Keyboard
Keyboard
(NDF-369)
1
Attachment2
3. Procedure
(2) Export
(6) Import
2
Attachment2
3
Attachment2
(3) Press up key or down key, select [4. Software Upgrade] and press ‘Enter’ key on Maintenance
Menu screen. Software Upgrade menu screen (refer to Fig.3-1b) will be displayed.
(4) Press up key or down key, select [1. Target] and press ‘Enter’ key on Software Upgrade menu
screen (refer to Fig.3-1b).
(5) Press up key or down key, select “DTE Main” and press ‘Enter’ key.
4
Attachment2
(7) Press up key or down key, select [2. Input Port] and press ‘Enter’ key on Software Upgrade menu
screen (refer to Fig.3-1b).
(8) Press up key or down key, select “USB Memory” and press ‘Enter’ key.
(9) Insert the USB Flash memory which contains DTE Main software and auxiliary file for recovery
to the DTE.
NOTE
- USB symbol will be displayed next to screen title when USB Flash memory is inserted.
- To remove the USB Flash memory safely, press ‘Shift + R’ keys.
(10) Press up key or down key, select [4. File Selection] and press ‘Enter’ key on Software Upgrade
menu screen (refer to Fig.3-1b).
(11) Press up key or down key, select DTE Main software and press ‘Enter’ key.
4.File Selection:JUE87_DTE_0201.BIN
5
Attachment2
Select [Cancel]
Select [OK]
Update Failure
Update Success
6
Attachment2
3-2 Export
Save the each parameter into a file or print out before the ACSE/IME updating, because the updating
clears all the parameters of ACSE/IME.
NOTE
1. About the data of received message, EGC message, and alarm pack, save them to a file or
print out, because upgrading software clears all of them away.
7
Attachment2
8
Attachment2
(5) Enter the name of Export file and Press [F1] (Fig.3-2d will be displayed).
NOTE:Export file name is "***.IN2".
(6) Press [OK] in Fig.3-2d. Then the Export will start and Fig.3-2e will be displayed.
9
Attachment2
10
Attachment2
11
Attachment2
NOTE
12
Attachment2
(3) Press up key or down key, select [4. Software Upgrade] and press ‘Enter’ key on Maintenance
Menu screen. Software Upgrade menu screen (refer to Fig.3-3b) will be displayed.
(4) Press up key or down key, select [1. Target] and press ‘Enter’ key on Software Upgrade menu
screen (refer to Fig.3-3b).
(5) Press up key or down key, select “IME” and press ‘Enter’ key.
1.Target : IME
NOTE
13
Attachment2
(7) Press up key or down key, select [2. Input Port] and press ‘Enter’ key on Software Upgrade menu
screen (refer to Fig.3-3b).
(8) Press up key or down key, select “USB Memory” and press ‘Enter’ key.
(9) Insert the USB Flash memory which contains IME software.
NOTE
- USB symbol will be displayed next to screen title when USB Flash memory is inserted.
- To remove the USB Flash memory safely, press ‘Shift + R’ keys.
(10) Press up key or down key, select [4. File Selection] and press ‘Enter’ key on Software Upgrade
menu screen (refer to Fig.3-3b).
(11) Press up key or down key, select software and press ‘Enter’ key.
NOTE
When an upgrade confirmation screen isn't displayed even if '*' key is pressed after the procedure
(1)-(11) is put into effect, please press Ctrl+I key.
After confirming that "- Press '*' key" is shown to< Functions>, please press '*' key once again.
14
Attachment2
Select [Cancel]
Select [OK]
Update Failure
Update Success
15
Attachment2
NOTE
Be careful about the following thing about update work.
・When a power supply of a terminal became off while doing an update, there is a possibility
that JUE-87 doesn't start. The update is possible even in that case. Try an update once again.
NOTE
16
Attachment2
(3) Press up key or down key, select [4. Software Upgrade] and press ‘Enter’ key on Maintenance
Menu screen. Software Upgrade menu screen (refer to Fig.3-4b) will be displayed.
(4) Press up key or down key, select [1. Target] and press ‘Enter’ key on Software Upgrade menu
screen (refer to Fig.3-4b).
(5) Press up key or down key, select “ACS” and press ‘Enter’ key.
1.Target : ACS
NOTE
17
Attachment2
(7) Press up key or down key, select [2. Input Port] and press ‘Enter’ key on Software Upgrade menu
screen (refer to Fig.3-4b).
(8) Press up key or down key, select “USB Memory” and press ‘Enter’ key.
(9) Insert the USB Flash memory which contains ACSE software.
NOTE
- USB symbol will be displayed next to screen title when USB Flash memory is inserted.
- To remove the USB Flash memory safely, press ‘Shift + R’ keys.
(10) Press up key or down key, select [4. File Selection] and press ‘Enter’ key on Software Upgrade
menu screen (refer to Fig.3-4b).
(11) Press up key or down key, select software and press ‘Enter’ key.
NOTE
When an upgrade confirmation screen isn't displayed even if '*' key is pressed after a procedure
(1)-(11) is put into effect, please press Ctrl+I key.
After confirming that "- Press '*' key" is shown to< Functions>, please press '*' key once again.
18
Attachment2
Select [Cancel]
Select [OK]
Update Failure
Update Success
19
Attachment2
NOTE
NOTE
(3) Press up key or down key, select [5. Inmarsat-C Setting & Checking] and press ‘Enter’ key on
Maintenance Menu screen. Then, select [Data Initialize] and press ‘Enter’ key.
Inmarsat-C Checking screen (refer to Fig.3-5b) will be displayed.
20
Attachment2
(4) Press up key or down key, select [FROM Clear] and press ‘Enter’ key.
(5) Select [OK] and press ‘Enter’ key then FROM Clear will be started.
21
Attachment2
(6) Fig.3-5d is displayed when the FROM Clear is completed. Press [F10].
(7) Carry out SRAM Clear, too. Following the procedure (4)-(6) but selecting “2 SRAM CLEAR” in
fig3-5b.
22
Attachment2
3-6 Import
(1) Turn on the IME.
(2) The boot screen will be displayed about 5 seconds after turning on the IME.
Press the ‘N’+ ‘D’+ ‘Z’ keys during “now loading” in the boot screen.
The maintenance mode will be initiated.
NOTE
(3) Press up key or down key, select [5. Inmarsat-C Setting & Checking] and press ‘Enter’ key on
Maintenance Menu screen. Then, select [Export/Import] and press ‘Enter’ key.
Export/Import screen (refer to Fig.3-6b) will be displayed.
23
Attachment2
(5) Press up key or down key, select Import file or enter the name of Import file.
Then press ‘Enter’ key. (Fig.3-6d will be displayed).
24
Attachment2
(6) Select [OK] and press ‘Enter’ key in Fig.3-6d. Then the Import will start and Fig.3-6e will be
displayed.
25
Attachment2
(7) Fig.3-6f is displayed when the Export is completed. Press ‘F10’ key.
26
Attachment2
(3) Press ‘Alt + A’ keys from DTE main menu (Fig.3-7b will be displayed).
27
Attachment2
(4) Press up key or down key, select [Alarm history] and press ‘Enter’ key on Diagnostics Menu
(Fig.3-7c will be displayed).
28
Attachment3
2. Preparation
1) Prepare below parts
PC
Straight serial cable
3. Procedure
3-1 Outlines
2) Export
6) SRAM/FROM Clear
7) Import
-1-
Attachment3
NOTE
Please note the following matters for upgrading.
1. JUE-85 might not shift to the update mode due to the compatibility of PC and the USB
serial conversion cable. In this case, please try the work about ten times repeatedly.
The mode might shift normally when several times tried.
2. JUE-85 might not start normally after turning off the power supply of the terminal during
upgrading. Even in this case, upgrading is also possible.
Try upgrading again.
3-2 Details
JUE-85-A/95SA-A/95VM-A/95LT-A
Straight serial cable
EME
COM1
X3 MAIN DTE (RS-232C)
IME PC
-2-
Attachment3
2) Export
Save the each parameter into a file or print out before the ACSE/IME updating, because the
updating clears all the parameters of ACSE/IME.
NOTE
About the data of received message, EGC message, and alarm pack, save them to a file or print
out, because upgrading software clears all of them away.
-3-
Attachment3
(2) Click [Export/Import] from MENU LIST. Then, the column of [Export/Import] is displayed in
the right side of the screen (refer to Fig.2).
-4-
Attachment3
(4) Enter the name of Export file and click [Save] (Fig.4 is displayed).
(5) Click [Yes] in Fig.4. Then the Export is started and Fig.5 is displayed.
-5-
Attachment3
-6-
Attachment3
-7-
Attachment3
-8-
Attachment3
(4) When the dialog box of Fig.A1.2.1.3c is displayed, turn OFF the power switch of the IME. And
click [OK] after the LED of the IME is automatically turned off.
(5) When the dialog box of Fig.12 is displayed, turn ON the power switch of the IME.
(6) The dialog box of Fig.A1.2.1.3e is displayed when the acquisition of terminal software
information is succeeded. Click [OK].
-9-
Attachment3
(7) When [OK] button in Fig.13 (dialog box) is clicked, the screen is returned to ACSE/IME
software updating screen and [Old module OK] is displayed in the [Information] column of
[Old] (refer to Fig.14).
(8) Click [FILE SELECT] button and display [File Select] dialog box (refer to Fig.15).
- 10 -
Attachment3
(9) When ACSE software [JUE85-A_ACS1054.jrc] is selected at Fig.15, the screen is return to
ACSE/IME software updating screen and [It is possible to update!] is displayed in the lower
part of [Update] column (refer to Fig.16).
- 11 -
Attachment3
(11) Click [Yes] in Fig.17. Then the updating is started and Fig.18 is displayed during updating.
When the power source of the terminal is turned off during update, repeat the procedure from (3).
- 12 -
Attachment3
- 13 -
Attachment3
- 14 -
Attachment3
6) SRAM/FROM Clear
(1) Activate the PC tool [winIST_CN149] on your PC.
(2) Click [SRAM/FROM Clear] from MENU LIST. Then, the column of [SRAM/FROM Clear] is
displayed in the right side of the screen (refer to Fig.22).
(3) Click [SRAM Clear] Start button. Fig.23 is displayed. Click [OK].
(4) Click [FROM Clear] Start button. Fig.24 is displayed. Click [OK].
- 15 -
Attachment3
7) Import
(1) Activate the PC tool [winIST_CN149] on your PC.
(2) Click [Export/Import] from MENU LIST. Then, the column of [Export/Import] is displayed in
the right side of the screen (refer to Fig.25).
- 16 -
Attachment3
(4) Enter the name of Import file and click [Open] in Fig.26 (Fig.27 is displayed).
- 17 -
Attachment3
- 18 -
Attachment4
August 8, 2019
Marine Satellite Communications Group
Marine Electronics Engineering Department
1. Outline
This manual explains confirmation procedure of internal GPS type for Inmarsat-C/mini-C with
NAF-253’s series. If CCA-600 is installed, confirm the software version and update according to
the attachment 2 or attachment 3.
1
Attachment4
(3) Select [Alarm history] and press ‘Enter’ key on Diagnostics Menu. (Fig.2 will be displayed).
*1 If NAF-253GM is equipped for JUE-85, the item ‘G:’ is displayed. And if NAF-741GM is
equipped, the item ‘G:’ is not displayed, and in that case, ACSE software update is unneccesary.
*2 ‘N’ may be displayed for about one minute after Inmarsat-C terminal starts up.
However, Inmarsat-C terminal has no problem, if ‘6’ or ’7’ is displayed after one minute.
2
Attachment4
(3) Select the item ‘Alarm Pack’ in the menu list, and click ‘READ’. (Fig.3 will be displayed)
*1 If NAF-253 series is equipped, the item ‘G:’ is displayed. And if NAF-741 / NAF-742
series are equipped, the item ‘G’ is not displayed, and in that case, ACSE software update is
unneccesary.
*2 ‘N’ may be displayed for about one minute after Inmarsat-C terminal starts up.
However, Inmarsat-C terminal has no problem, if ‘6’ or ’7’ is displayed after one minute.
3
別紙 5
Attachment 5
ソフトウェアバージョンの変更又は各機器・基板交換後、必要事項を記入して速やかに返却願います。
Fill in this form and return promptly, after change of a software version, or each apparatus and
substrate replaced.
*「件名」の先頭には“MR-INMARSAT-C_”を必ず付記してください。
Input a ”MR-INMARSAT-C_” into the head of the subject name of an e-mail.
船名
Name of Vessel
個別番号
MES Identification No.
ISN 4JR190
総合番号
GR
JUE-87 System Serial No.
機器名 項目 交換前 交換後
Unit name Item Old New
機器製造番号
GR GR
Unit serial No.
屋内装置
DTE ソフトウェアメンテナンス番号
IME Ver. Ver.
DTE software maintenance number
NTF-318
IME ソフトウェアメンテナンス番号
Ver. Ver.
IME software maintenance number
機器製造番号
屋外装置 GR GR
Unit serial No.
EME
ACS ソフトウェアメンテナンス番号
NAF-253GM Ver. Ver.
ACS software maintenance number
機器製造番号
プリンター QEDY QEDY
Unit serial No.
Printer
ファームウェア番号
NKG-900 Ver. Ver.
Firmware number
工事日
Service Date
港
Service Port
オーダ
Service Order
代理店
Service Agent
作業者
Service Engineer
作業後に動作(送受信など)が正常であることを確認
YES NO
The normal operation check after work
メモリークリア 実行 未実行
Memory clear Executed Not Executed
備考
Remarks
別紙 6
Attachment 6
ソフトウェアバージョンの変更又は各機器・基板交換後、必要事項を記入して速やかに返却願います。
Fill in this form and return promptly, after change of a software version, or each apparatus and
substrate replaced.
Maintenance report
日本無線株式会社
Japan Radio Co., Ltd.
メンテナンスレポート
E-mail : maintenance-report@jrc.co.jp
E-mail: maintenance-report@jrc.co.jp
*「件名」の先頭には“MR-INMARSAT-C_”を必ず付記してください。
Input a ”MR-INMARSAT-C_” into the head of the subject name of an e-mail.
船名
Name of Vessel
個別番号
MES Identification No.
ISN 4JR140
総合番号
GR
JUE-85 System Serial No.
機器名 項目 交換前 交換後
Unit name Item Old New
機器製造番号
屋内装置 GR GR
Unit serial No.
IME
IME ソフトウェアメンテナンス番号
NTF-781GM Ver. Ver.
IME software maintenance number
機器製造番号
DTE
Unit serial No.
NDZ-227 or
NDZ-127C1 DTE ソフトウェアメンテナンス番号
Ver. Ver.
DTE software maintenance number
屋外装置 機器製造番号
GR GR
EME Unit serial No.
NAF-741GM or ACS ソフトウェアメンテナンス番号
Ver. Ver.
NAF-253GM5 ACS software maintenance number
プリンター
機器製造番号
Printer QEDY QEDY
Unit serial No.
NKG-900
工事日
Service Date
港
Service Port
オーダ
Service Order
代理店
Service Agent
作業者
Service Engineer
作業後に動作(送受信など)が正常であることを確認
YES NO
The normal operation check after work
メモリークリア 実行 未実行
Memory clear Executed Not Executed
備考
Remarks
別紙 7
Attachment 7
ソフトウェアバージョンの変更又は各機器・基板交換後、必要事項を記入して速やかに返却願います。
Fill in this form and return promptly, after change of a software version, or each apparatus and
substrate replaced.
*「件名」の先頭には“MR-INMARSAT-C_”を必ず付記してください。
Input a ”MR-INMARSAT-C_” into the head of the subject name of an e-mail.
船名
Name of Vessel
個別番号
MES Identification No.
ISN 4JR
モデル
JUE-95SA JUE-95VM JUE-95LT
Model
総合番号
GR
System Serial No.
機器名 項目 交換前 交換後
Unit name Item Old New
機器製造番号
屋内装置 GR GR
Unit serial No.
IME
IME ソフトウェアメンテナンス番号
NTF-782 Ver. Ver.
IME software maintenance number
屋外装置 機器製造番号
GR GR
EME Unit serial No.
NAF-742 or ACS ソフトウェアメンテナンス番号
Ver. Ver.
NAF-253 ACS software maintenance number
工事日
Service Date
港
Service Port
オーダ
Service Order
代理店
Service Agent
作業者
Service Engineer
作業後に動作(送受信など)が正常であることを確認
YES NO
The normal operation check after work
メモリークリア 実行 未実行
Memory clear Executed Not Executed
備考
Remarks