10% 10 kW 93.2%
20% 20 kW 96.1%
30% 30 kW 96.5%
50% 50 kW 96.7%
75% 75 kW 96.5%
100% 100 kW 96.1%
PowerGate Plus 100 kW Specifications UL/CSA CE
1 2
315V minimum 480V model
Input Parameters
Unparalleled Performance Maximum Array Input Voltage 600 VDC
900 VDC
With their advanced system
PV Array Configuration Positive Ground o o
intelligence, next-generation Edge™
MPPT technology, and industrial-grade Negative Ground o
maximize system uptime and power Input Voltage Range (MPPT; Full Power) 315–600 VDC
480 VAC
Proven Reliability
600 VAC
large-scale installations.
Nominal Output Frequency 60 Hz
Low Maintenance 50 Hz
Number of Phases 3
Safety
145 A 400 VAC
exception of the GFDI circuit) from the Maximum Continuous Output Power 100 kW (100 kVA)
Noise
Output Options Noise Level <65 dB(A)
Combiner
PowerGate Plus 100 kW
Number of Inputs and Fuse Rating 5 (110 ADC) o
5 (125 ADC) o
240 VAC Output
Inverter Cabinet
480 VAC Output Enclosure Rating NEMA 3R
CE 400 VAC Output Enclosure Finish RAL-7032
(14-Gauge, Powder-Coated G90 Steel)
Cabinet Dimensions (Height x Width x Depth) 80" x 57" x 30.84" (203.2 cm x 144.78 cm x 78.33 cm)
Streamlined Design Cabinet Weight 2,350 lbs. 1,066 kg
With all components encased in Transformer
a single, space-saving enclosure, Integrated Internal Transformer
Intelligent Monitoring
Output Transformer Satcon PV View® Plus o o
Satcon PV Zone® o o
Provides galvanic isolation
Third-Party Compatibility