Professional Documents
Culture Documents
WinCan VX Demo Chelsea Rehab
WinCan VX Demo Chelsea Rehab
Project
Project Name: WinCan VX Demo Chelsea
Project Description: Sample Survey
Project Number: CHEL999
Project Date: 15/04/2016
Project Standard: MSCC4 Sewers & Drainage (GB)
WinCan VX SAMPLE
Table of Contents
Project Name Project Number Project Date
WinCan VX Demo Chelsea CHEL999 15/04/2016
WinCan VX SAMPLE
Section: 1; MH2603 > MH2604 (MH2603X) ............................................................................................................
1
Section: 2; CP3301 > MH3302 (CP3301X) .............................................................................................................
10
Node: 1; MH2601 ......................................................................................................................................................
16
Node: 2; CP3301 .......................................................................................................................................................
20
Node: 3; MH3302 ......................................................................................................................................................
24
Node: 4; MH2603 ......................................................................................................................................................
27
Node: 5; MH2604 ......................................................................................................................................................
30
Material Distribution ...................................................................................................................................................
34
Inspection Status .......................................................................................................................................................
35
Profile Distribution ......................................................................................................................................................
36
Defect Classification Statistics ...................................................................................................................................
37
Statistics on Waste Water Type ..................................................................................................................................
38
Infiltration Analysis .....................................................................................................................................................
39
Construction Year Decades .......................................................................................................................................
40
WinCan ......................................................................................................................................................................
41
Project Information
Project Name Project Number Project Date
WinCan VX Demo Chelsea CHEL999 15/04/2016
Client
Company: Borough Council
Description: Junction of North St and High Rd
Contact: Dave Stewart
Department: Flooding
Street: High Street
Town or City: Sometown
County: London
Post Code: W1 5GG
Phone: 01234 123456
Fax:
Mobile:
WinCan VX SAMPLE
01234 555444
07777 654321
Email: dave.stewart@email.com
Contractor
Company: WinCan Europe Ltd
Description: Software Vendor
Contact: Steve Peregrine
Department: Technical
Street: Albert Drive
Town or City: Woking
County: Surrey
Post Code: GU21 5JY
Phone: 01483 762222
Fax: 01483 763333
Mobile: 07498 987156
Email: s.peregrine@wincaneurope.com
Project Information
Project Name Project Number Project Date
WinCan VX Demo Chelsea CHEL999 15/04/2016
Project Summary
Executive Summary
There are some structural repairs required and we would also recommend some cleaning of
the existing assets.
WinCan VX SAMPLE
Project Information
Project Name Project Number Project Date
WinCan VX Demo Chelsea CHEL999 15/04/2016
Project Notes
Preliminary Info
The team arrived at 9:30am and located the chambers included in the job scope. It was
clear that the foul and surface water drainage systems appeared at first glance to be in a
reasonable working order and flowing. There was no indication of any immediate or recent
surcharge or surrounding pollution incidents.
WinCan VX SAMPLE
After cleaning, section resurveyed from CP3301 to MH3302. Inspection completed. The
pipe section is severely damaged but flowing ok. There is a risk of surrounding ground
errosion and possible surface collapse due to the poor structural integrity of this pipe.
CP3301 to MH3302 - inspection complete. This surface water pipe has some minor defects
but is predominantly in an excellent condition, comensurate with its age.
MH2601 to CN2601 - inspection abandoned at 22m due to loss of traction with the camera
system. The pipe is believed to be approximately 46m long.
Project Information
Project Name Project Number Project Date
WinCan VX Demo Chelsea CHEL999 15/04/2016
Drawing Legend
Soakaway Surface
Buchan Trap Oil Separator
Water
WinCan VX SAMPLE
Combined SVP & RWP Pump Chamber Toilet Manhole
Project Information
Project Name Project Number Project Date
WinCan VX Demo Chelsea CHEL999 15/04/2016
Project Drawing
WinCan VX SAMPLE
Scoring Summary
Project Name Project Number Project Date
WinCan VX Demo Chelsea CHEL999 15/04/2016
Structural Defects
Grade 3: Best practice suggests consideration should be given to repairs in the medium term.
Grade 4: Best practice suggests consideration should be given to repairs to avoid a potential
collapse.
Grade 5: Best practice suggests that this pipe is at risk of collapse at any time. Urgent
consideration should be given to repairs to avoid total failure.
Abandoned Surveys
Section PLR Description
3 MH2601X Survey abandoned
Information
These scoring summaries are based on the SRM grading from the WRc.
Project Pictures
Project Name Project Number Project Date
WinCan VX Demo Chelsea CHEL999 15/04/2016
WinCan VX SAMPLE
Westminster Map Westminster Satelite
Section Profile
Project Name Project Number Project Date
WinCan VX Demo Chelsea CHEL999 15/04/2016
Circular, 600 mm
Inspected
Section Upstream Node Downstream Node Date Road Pipe Material Total Length
Length
2 CP3301 MH3302 08/08/2008 North Street Concrete 23.00 m 23.00 m
Total: 1 Inspection x Circular 600 mm = 23.00 m Total Length and 23.00 m Inspected Length
WinCan VX SAMPLE
Total: 2 Inspections = 47.80 m Total Length and 47.80 m Inspected Length
Node Profile
Project Name Project Number Project Date
WinCan VX Demo Chelsea CHEL999 15/04/2016
Catchpits
Node
Node Node ID Town or Village Road Date
Depth
2 CP3301 Chelsea North Street 2.900 m 15/04/2016
Total: 1 Catchpit
Manholes
Node
Node Node ID Town or Village Road Date
Depth
1
3
4
MH2601
MH3302
MH2603
WinCan VX SAMPLE
Chelsea
Chelsea
West End
North Street
North Street
North Street
2.057 m
1.640 m
1.360 m
15/04/2016
15/04/2016
15/04/2016
5 MH2604 West End North Street 0.720 m 15/04/2016
Total: 4 Manholes
Total: 5 Nodes
Section Summary
Project Name Project Number Project Date
WinCan VX Demo Chelsea CHEL999 15/04/2016
Number of sections 5
WinCan VX SAMPLE
Number of section inspection photos
Section Summary
Project Name Project Number Project Date
WinCan VX Demo Chelsea CHEL999 15/04/2016
Project Summary
Project Name Project Number Project Date
WinCan VX Demo Chelsea CHEL999 15/04/2016
Section Summary
Sect.
PLR Upstream Node Downstream Node Road Town Type Use Mat. Profile Length
No.
1 MH2603X MH2603 MH2604 North Street West End SEC F VC Egg shaped 225/150mm 24.80 m
2 CP3301X CP3301 MH3302 North Street West End SEC S CO Circular 600mm 23.00 m
3 MH2601X MH2601 CN2601 North Street West End LAT S VC Circular 300mm 46.00 m
Total: 93.80 m
Section Levels
Sect. Downstream Downstream Downstream
PLR Upstream Node Upstream C.L. Upstream I.L. Upstream I.D. Downstream Node
WinCan VX SAMPLE
No. C.L. I.L. I.D.
1 MH2603X MH2603 123.833 m 122.473 m 1.360 m MH2604 122.840 m 122.120 m 0.720 m
2 CP3301X CP3301 123.826 m 121.626 m 2.200 m MH3302 122.843 m 121.203 m 1.640 m
3 MH2601X MH2601 123.766 m 121.709 m 2.057 m CN2601 121.354 m 121.354 m 0.000 m
Inspection Summary
Sect. Insp.
Upstream Node Downstream Node Dir. Operator Insp. Date Insp. Time Str Ser Final Observation Length
No. No.
1 1 MH2603 MH2604 US Paul 08/08/2008 10:31 3 5 MHF 24.80 m
2 1 CP3301 MH3302 US Paul 08/08/2008 10:39 1 3 MHF 23.00 m
3 1 MH2601 CN2601 US Paul 08/08/2008 10:39 2 3 SA, Unable to continue 22.00 m
Project Summary
Project Name Project Number Project Date
WinCan VX Demo Chelsea CHEL999 15/04/2016
Sect. Insp.
Upstream Node Downstream Node Dir. Operator Insp. Date Insp. Time Str Ser Final Observation Length
No. No.
Total: 69.80 m
Defect Summary
WinCan VX SAMPLE
CCTV Drainage Survey Observation Count
General Structural Condition Service Condition
Encrustation
Under Water
Obstruction
Abandoned
Length (m)
Infiltration
No. Grade
Collapsed
Displaced
Deformed
Fractures
Deviates
4/5 Obs.
Damage
Camera
Surface
Broken
Grease
Survey
Cracks
Joints
Joints
Roots
Water
Holes
Open
Level
Insp.
Sect. Insp.
Line
Silt
No. No. Upstream Node Downstream Node
1 1 MH2603 MH2604 24.8 9 3 12 5 3 5 3
2 1 CP3301 MH3302 23.0 3 4 1 1 1
3 1 MH2601 CN2601 22.0 1 3 1 1
Total: 69.8 9 1 6 19 5 3 1 6 5 1
Town or Village: West End Inspection Direction: Upstream Upstream Node: MH2603
Road: North Street Inspected Length: 24.80 m Upstream Pipe Depth: 1.360 m
Location: Gardens Total Length: 24.80 m Downstream Node: MH2604
Surface Type: Grass Joint Length: 1.50 m Downstream Pipe Depth: 0.720 m
Use: Foul Pipe Shape: Egg shaped
Type of Pipe: Gravity drain/sewer Dia/Height: 225 mm Width: 150 mm
Year Constructed: 1925 Pipe Material: Vitrified clay pipe (i.e. all clayware)
Flow Control: No flow control Lining Type: No Lining
Inspection Purpose: Sample survey to determine asset condition Lining Material: Polyester
Comments: Structural damage throughout.
Recommendations: Requires full length liner.
MH2604
WinCan VX SAMPLE
Depth: 0.72 m
0.00 MH Start node type, manhole, reference number: MH2604 00:00:00
1.20 MCVC Material changes to Vitrified clay (i.e. all clayware) 00:00:58
1.33 S03 FL Fracture, longitudinal at 12 o'clock, Start: Position wanders 00:01:23 1-1-7A
4.74 RMJ Roots, mass at joint, 15% cross-sectional area loss 00:05:45 1-1-13A 3
WinCan VX SAMPLE
12.05 FL Fracture, longitudinal at 12 o'clock 00:07:13 1-1-19A 3
14.71 S04 FL Fracture, longitudinal at 11 o'clock, Start: Position wanders 00:08:22 1-1-26A
20.93 MCVC Material changes to Vitrified clay (i.e. all clayware) 00:09:35 1-1-33A
21.62 DEX Settled deposits, other, 10% cross-sectional area loss: 00:11:48 1-1-35A 3
Stone.
WinCan VX SAMPLE
22.94 HJ Hole in drain/sewer at joint from 11 o'clock to 4 o'clock 00:14:41 1-1-36A 5
24.80 MHF Finish node type, manhole, reference number: MH2604 00:15:20 1-1-38A
WinCan VX SAMPLE
WinCan VX SAMPLE
1-1-5A, 00:00:59, 1.21 m
Water level, 20% of the vertical dimension
1-1-7A, 00:01:23, 1.33 m
Fracture, longitudinal at 12 o'clock, Start, Position wanders
WinCan VX SAMPLE
1-1-12A, 00:05:27, 3.58 m
Roots, fine, From break.
1-1-13A, 00:05:45, 4.74 m
Roots, mass at joint, 15% cross-sectional area loss
WinCan VX SAMPLE
1-1-21A, 00:07:25, 13.32 m
Broken pipe at joint from 11 o'clock to 12 o'clock
1-1-22A, 00:07:28, 13.59 m
Broken pipe at joint from 7 o'clock to 12 o'clock
WinCan VX SAMPLE
1-1-31A, 00:09:11, 18.27 m
Material changes to Concrete
1-1-33A, 00:09:35, 20.93 m
Material changes to Vitrified clay (i.e. all clayware)
WinCan VX SAMPLE
Town or Village: West End Inspection Direction: Downstream Upstream Node: CP3301
Road: North Street Inspected Length: 23.00 m Upstream Pipe Depth: 2.200 m
Location: Property with buildings Total Length: 23.00 m Downstream Node: MH3302
Surface Type: Asphalt Highway Joint Length: 1.50 m Downstream Pipe Depth: 1.640 m
Use: Surface water Pipe Shape: Circular
Type of Pipe: Gravity drain/sewer Dia/Height: 600 mm
Year Constructed: 1925 Pipe Material: Concrete
Flow Control: No flow control Lining Type: No Lining
Inspection Purpose: Investigation of suspected operational problem Lining Material: No Lining
Comments: None
Recommendations: None
CP3301
WinCan VX SAMPLE
Depth: 2.20 m
0.00 MH Start node type, manhole, reference number: CP3301 00:00:00
14.80 CXZ Position defective, other at 2 o'clock, diameter: 225mm: 00:02:06 2-1-8A
JN2601
15.50 GP General photograph taken at this point: View up connecting 00:03:10 2-1-13A
pipe.
22.60 GP General photograph taken at this point: Finish manhole 00:04:55 2-1-15A
base.
23.00 MHF Finish node type, manhole, reference number: MH3302 00:06:04
MH3302
23.00 Super-Combi - End
Depth: 1.64 m
WinCan VX SAMPLE
WinCan VX SAMPLE
WinCan VX SAMPLE
2-1-4A, 00:01:36, 11.70 m
Cracks, spiral from 1 o'clock to 3 o'clock
2-1-5A, 00:01:50, 12.00 m
Surface damage, spalling at 2 o'clock, At joint
WinCan VX SAMPLE
2-1-10A, 00:02:24, 15.20 m
Fracture, longitudinal at 2 o'clock
2-1-11A, 00:02:31, 15.40 m
Fracture, circumferential from 3 o'clock to 5 o'clock, From
connection hole.
WinCan VX SAMPLE
Node Report
Node ID Alternative ID Date Node Type Year Constructed Use
MH2601 15/04/2016 Manhole 1950 Surface Water
Operator Vehicle Client`s Job Ref Contractor`s Job Ref Node Depth Criticality
Paul FY15 GHY WCE 1234 WO 999 2.06 m Unknown
Weather: No rain or snow Vertical Ref.: Cover (highest corner of frame or highest point on a circular frame)
Temperature: Above freezing Circular Ref.: 6 o'clock
Sheet Number: 1 Inspection Method: Direct inspection
Status: Public Surcharge Level:
Flow Control:
Cover Shape:
Cover Hinge?
WinCan VX SAMPLE
No flow control
Rectangular
No
Inspection Purpose:
Cover Duty:
Cover Lock?
Investigation of known defects
Heavy
No
Side Entry? No Regular Courses? Not Applicable
Material: Concrete Construction Style: Pre-Cast Concrete
Comments: None
Recommendations: None
Observations
Inlets/Outlets
Clock
No. Depth Type Shape Dia Width PLR Remarks
Position
1 6 2.06 m Outlet Circular 900 mm MH2601X None.
2 1 1.99 m Inlet Circular 750 mm GY01X None
3 8 1.77 m Inlet Circular 300 mm None
4 5 1.08 m Inlet Circular 250 mm GY03X Intruding Slightly
5 1 1.10 m Inlet Circular 250 mm GY04X Intruding slightly
Node Report
Node ID Alternative ID Date Node Type Year Constructed Use
MH2601 15/04/2016 Manhole 1950 Surface Water
Operator Vehicle Client`s Job Ref Contractor`s Job Ref Node Depth Criticality
Paul FY15 GHY WCE 1234 WO 999 2.06 m Unknown
Cover 1
Shaft 2
Reducing Slab 3
Chamber 4
Access 5
Steps Material: Metal Encapsulated In Plastic Steps Type: Single Width - Wide Enough For One Foot Only
Clock: 3 Requires Attention? No
Remarks: None
WinCan VX SAMPLE
1-1-1A, 0.00 m
General remark, CleverScan
1-1-2A, 1.08 m
Connection, free drop into channel
1-1-3A, 1.10 m
Connection, free drop into channel
0m
2 3
1m
WinCan VX SAMPLE
4
2m
6 9 12 3 6
5
6
12
9 3
Node Report
Node ID Alternative ID Date Node Type Year Constructed Use
CP3301 15/04/2016 Catchpit 1950 Surface Water
Operator Vehicle Client`s Job Ref Contractor`s Job Ref Node Depth Criticality
Paul FY15 GHY WCE 1234 WO 999 2.90 m Unknown
Weather: No rain or snow Vertical Ref.: Cover (highest corner of frame or highest point on a circular frame)
Temperature: Above freezing Circular Ref.: 6 o'clock
Sheet Number: 2 Inspection Method: CCTV
Status: Highway Drain Surcharge Level:
Flow Control:
Cover Shape:
Cover Hinge?
WinCan VX SAMPLE
No flow control
Rectangular
No
Inspection Purpose:
Cover Duty:
Cover Lock?
Sample survey to determine asset condition
Heavy
No
Side Entry? No Regular Courses? Yes
Material: Brick Construction Style: Brick
Comments: None
Recommendations: None
Observations
Inlets/Outlets
Clock
No. Depth Type Shape Dia Width PLR Remarks
Position
4 6 2.20 m Outlet Circular 300 mm CP3301X None
5 11 2.14 m Inlet Circular 300 mm None
6 8 1.14 m Inlet Circular 150 mm None
Node Report
Node ID Alternative ID Date Node Type Year Constructed Use
CP3301 15/04/2016 Catchpit 1950 Surface Water
Operator Vehicle Client`s Job Ref Contractor`s Job Ref Node Depth Criticality
Paul FY15 GHY WCE 1234 WO 999 2.90 m Unknown
Cover 1
Shaft 2
Reducing Slab 3
Chamber 4
Invert 5
Access 6
Steps Material: Iron Or Steel Steps Type: Single Width - Wide Enough For One Foot Only
Clock: 3 Requires Attention? No
Remarks: None
WinCan VX SAMPLE
2-1-1A, 0.00 m
General remark, CleverScan
2-1-2A, 1.14 m
Connection, free drop into channel
2-1-4A, 2.39 m
Connecting pipeline, circular
0m
1m 2
WinCan VX SAMPLE
2m
4 3
6 9 12 3 6
12
9 3
Node Report
Node ID Alternative ID Date Node Type Year Constructed Use
MH3302 15/04/2016 Manhole 1925 Surface Water
Operator Vehicle Client`s Job Ref Contractor`s Job Ref Node Depth Criticality
Paul FY15 GHY WCE 1234 WO 999 1.64 m Unknown
Weather: No rain or snow Vertical Ref.: Cover (highest corner of frame or highest point on a circular frame)
Temperature: Above freezing Circular Ref.: 6 o'clock
Sheet Number: 3 Inspection Method: Direct inspection
Status: Surcharge Level:
Flow Control:
Material:
Comments:
WinCan VX SAMPLE
No flow control
Concrete
Inspection Purpose:
Construction Style:
Sample survey to determine asset condition
Recommendations:
Observations
Inlets/Outlets
Clock
No. Depth Type Shape Dia Width PLR Remarks
Position
5 12 1.64 m Inlet Circular 600 mm CP3301X Ok
WinCan VX SAMPLE
3-1-1A, 0.00 m
General photograph, o’clock direction the photo is taken from,
3-1-1B, 0.00 m
General photograph, o’clock direction the photo is taken from,
Overview Overview
0m
1m WinCan VX SAMPLE
6 9 12 3 6
12
9 3
Node Report
Node ID Alternative ID Date Node Type Year Constructed Use
MH2603 15/04/2016 Manhole 1925 Foul
Operator Vehicle Client`s Job Ref Contractor`s Job Ref Node Depth Criticality
Paul FY15 GHY WCE 1234 WO 999 1.36 m Unknown
Weather: No rain or snow Vertical Ref.: Cover (highest corner of frame or highest point on a circular frame)
Temperature: Above freezing Circular Ref.: 6 o'clock
Sheet Number: 4 Inspection Method: Direct inspection
Status: Surcharge Level:
Flow Control:
Material:
Comments:
WinCan VX SAMPLE
No flow control
Concrete
Inspection Purpose:
Construction Style:
Sample survey to determine asset condition
Recommendations:
Observations
Inlets/Outlets
Clock
No. Depth Type Shape Dia Width PLR Remarks
Position
2 6 1.36 m Outlet Circular 225 mm MH2601X Ok
WinCan VX SAMPLE
4-1-1A, 0.00 m
General photograph, o’clock direction the photo is taken from,
4-1-1B, 0.00 m
General photograph, o’clock direction the photo is taken from,
Overview Overview
0m
WinCan VX SAMPLE
1m
6 9 12 3 6
12
9 3
Node Report
Node ID Alternative ID Date Node Type Year Constructed Use
MH2604 15/04/2016 Manhole 1980 Foul
Operator Vehicle Client`s Job Ref Contractor`s Job Ref Node Depth Criticality
Paul FY15 GHY WCE 1234 WO 999 0.72 m Unknown
Weather: No rain or snow Vertical Ref.: Cover (highest corner of frame or highest point on a circular frame)
Temperature: Above freezing Circular Ref.: 6 o'clock
Sheet Number: 5 Inspection Method: Direct inspection
Status: Private Surcharge Level:
Toxic Atmosphere?
Flow Control:
Cover Shape:
WinCan VX SAMPLE
No
No flow control
Rectangular
Evidence of Vermin? N
Inspection Purpose: Sample survey to determine asset condition
Cover Duty: Medium
Cover Hinge? No Cover Lock? No
Side Entry? No Regular Courses? Yes
Material: Brick Construction Style: Brick
Comments: NONE
Recommendations: None.
Observations
Inlets/Outlets
Clock
No. Depth Type Shape Dia Width PLR Remarks
Position
3 6 0.72 m Outlet Circular 150 mm None.
4 8 0.65 m Inlet Circular 150 mm MH2603X None.
5 2 0.70 m Inlet Circular 150 mm None.
6 12 0.22 m Inlet Circular 150 mm None.
Cover 1
Node Report
Node ID Alternative ID Date Node Type Year Constructed Use
MH2604 15/04/2016 Manhole 1980 Foul
Operator Vehicle Client`s Job Ref Contractor`s Job Ref Node Depth Criticality
Paul FY15 GHY WCE 1234 WO 999 0.72 m Unknown
Reducing Slab 2
Chamber 3
Benching
WinCan VX SAMPLE 4
Channel 5
Access 6
Steps Material: Metal Encapsulated In Plastic Steps Type: Double Width - Wide Enough For Both Feet
Clock: 9 Requires Attention? No
Remarks: None.
WinCan VX SAMPLE
5-1-1A, 0.00 m
General photograph, o’clock direction the photo is taken from,
5-1-1B, 0.00 m
General photograph, o’clock direction the photo is taken from,
Overview Overview
0m
WinCan VX SAMPLE
0.5m
6 9 12 3 6
12
9 3
Material Distribution
Project Name Project Number Project Date
WinCan VX Demo Chelsea CHEL999 15/04/2016
Concrete
Brick
WinCan VX SAMPLE 2
Unknown
Sections Laterals
Concrete
1 Unknown
3
1 1
Vitrified clay pipe (i.e. all clayware)
Vitrified clay pipe (i.e. all clayware)
Inspection Status
Project Name Project Number Project Date
WinCan VX Demo Chelsea CHEL999 15/04/2016
inspected
8
uninspected 4
WinCan VX SAMPLE
Sections Laterals
uninspected
3
inspected 2
1
inspected
Nodes
uninspected
1
5
inspected
Profile Distribution
Project Name Project Number Project Date
WinCan VX Demo Chelsea CHEL999 15/04/2016
Circular 300mm
WinCan VX SAMPLE
Egg shaped 225/150mm
1
9 Unknown
1
Circular 600mm
Sections Laterals
1
Circular 600mm
1
Circular 300mm
WinCan VX SAMPLE
Grade 3
1.00
Grade 1
4.00
1.00
Grade 2
Sections
Grade 3
1
4
Grade 1
Surface water
6
Sections Laterals
Surface water
1
4
Foul
1
Surface water
Nodes
Infiltration Analysis
Project Name Project Number Project Date
WinCan VX Demo Chelsea CHEL999 15/04/2016
WinCan VX SAMPLE
None
2 1 5
0 0 0 0 0 0
None Minor Severe None Minor Severe None Minor Severe
1980 - 1989
1
2 9 1920 - 1929
1950 - 1959
WinCan VX SAMPLE
Sections Laterals
5 1
1920 - 1929 1920 - 1929
Nodes
2
1950 - 1959
WinCan
Notes:
Thank you for choosing to use WinCan to carry out your drainage investigation works.
The results and views carried in this report are those of the engineer(s) appointed to carry out the investigation
and are considered relevant on the day of the survey. Drain and sewer performance is known to alter over time,
so liability cannot be accepted for differences between the recorded data and the actual data at a time after this
report was generated.
This survey has been created in accordance with the drainage standard used in the country and language
settings for this PC.
If a DVD has been supplied with this report, please not that it can only be used in a Windows based PC. Please
browse the DVD and navigate to the PDF folder to find project-based documents such as drawings, engineer's
site notes and survey specifications amongst others.
WinCan VX SAMPLE
CCTV subsidence investigations do not account for the water tightness of the pipes and are merely a visual
inspection of inside of the drains. CCTV drainage engineers are generally not qualified to comment on the causes
of subsidence, and can only suggest required remedial actions for the pipes, and not the affected buildings.
Subsidence is a building structural failure, which can occur for many reasons. Although drainage failures can
contribute to subsidence problems, other causes should always be investigated as part of a considered approach.
In order to eliminate drains from suspicion, WinCan suggests that all pipes within at least 10m of the subsidence
area be pressure tested over and above a CCTV inspection, and remedial suggestions considered based on the
findings.
Unless otherwise specified in an associated task order (or similar), the data gathered in this report may not be
suitable for use as a pre-lining investigation. WinCan are happy to carry out such surveys, but this must be
agreed prior to the commencement of the works, and a the client must specify the data they wish to capture and
the acceptable tolerances.
Where GPS coordinates and heights have been issued within this report, they are to 1m accuracy, and 2m
accuracy for heights. Greater accuracy can be provided on request.