Professional Documents
Culture Documents
5000
A A
COORDINATE TABLE INTERFACE SCHEDULE PROPOSED LAND EASEMENT
AREA = 259.30m²
3
ID EASTING NORTHING 36504
1 E=484192.786 N=2766256.707 ITEM UTILITIES PROTECTION E- EXISTING
ALIGNMENT CHAINAGE DISCIPLINE AUTHORITY DESCRIPTION OF INTERFACE
2 E=484210.775 N=2766280.239 CODE TYPE OF WORK P-PROPOSED E=483815.983
ITY VILLAGE
N=2766389.351
E)
RESERVATION (152.40m WID
TL27 JBL 9+760 UTILITIES ETISALAT EXISTING 6 WAY DUCTS CONCRETE SURROUND E E=483821.858
ROAD MCB8
134.71
TO GREEN COMMUN
TL-B1 JBL UTILITIES ETISALAT EXISTING 6 WAY DUCTS NO PROTECTION REQUIRED E
CH: 0+031
TING
69 EXIS
B 39/6/621 ROAD MCB9 EXTENSION OF EXISTING DUCTS. B
UC T TL-B2 JBL UTILITIES ETISALAT EXISTING 6 WAY DUCTS E
6-WAY D CH: 0+026 NO PROTECTION REQUIRED
180.33
0+300
TL27A JBL 10+000 UTILITIES ETISALAT EXISTING 9 WAY DUCTS (NOT EXIST AT SITE) NOT APPLICABLE E
116.12
ROAD MCB5
TL-B8 JBL UTILITIES ETISALAT EXISTING 9 WAY DUCTS (NOT NOT EXIST SITE) NOT APPLICABLE E
CH: 0+364
PROPOSED LAND EASEMENT
ROAD MCB6 AREA = 284.30m²
C LIMIT OF CONTRACT TL-B9 JBL UTILITIES ETISALAT EXISTING 9 WAY DUCTS (NOT EXIST AT SITE) NOT APPLICABLE E C
CH: 0+026
71.89
TIE IN WITH EXISTING 6/
83
/
L.O.C E=483929.833 63
06
5
N=2766387.257
TL-B7 E=483946.117
1:1
2
N=2766372.045
1:12
SLOPE
122.58
0+469
1:1 PE
SLO
2
0+400
6-WAY ETISALAT DUCT 0+100
EXISTING
TIE INTO
L.O.C
0+300 0+200
0+200
0+300
0+385
TRIAL PIT
0+363 10+200
10+100
0+300 JBL-TP245-TP246
C0306-JBL-EUT-ARD-059 10+000
0+40
0 EXISTING 6-WAY
9+900
ETISALAT DUCTS FOUND Duct not found at site.
EXISTING
0+200
E TL27A E
FILENAME :D:\BASHEER\2. DESIGN & CONSTRUCTION NOC\COMPREHENSSIVE PACKAGE\JBL-02 COMPREHENSIVE CONSTRUCTION NOC PACAKGE CH 8+000 TO 11+150\UTILITIES\CAD\TELECOM-ETISALAT\C0306-JBL-EUT-DG-36522-36526.DWG
1 Etisalat requested a
ES ROAD
90 9+800
0+100
A T °
11 EMIR new ductJBasL per the
TO E6 -0+000
CT
working drawing
6-WAY DU
16/6/58872
9+700
EXISTING
TIE INTO
L.O.C
9+600 0+000
CONCRETE
LIMIT OF CONTRACT
SURROUND 2
9+500 PROTECTION OF 0+362
LIMIT OF CONTRACT
0+300
EXISTING DUCT TL-B9
LENGTH = 29.75m 0+200
0+100
F 9+400 -0+000 L.O.C F
0+500
EXISTING ETISALAT DUCT NOT EXIST AT SITE TO E11 SHEIKH
AS PER SITE VERIFICATION DONE ON 09/02/2022 ZAYED ROAD
(BY ETISALAT Engi - Mr Naser Ahmed)
TRIAL PIT TL-B2 81/6/63064 EXISTING
JBL-TP247-TP248 6-WAY ETISALAT DUCT
C0306-JBL-EUT-ARD-059 71/6/63035 EXISTING EXISTING ETISALAT
EXISTING 6-WAY 6-WAY ETISALAT DUCT 254/4/63036 EXISTING MANHOLE
ETISALAT DUCTS FOUND 4-WAY ETISALAT DUCT JRC14\53197
270/4/63034 EXISTING
G 4-WAY ETISALAT DUCT G
EXISTING ETISALAT
MANHOLE
FOR CON -EUT-DG-36523
INE EE
DEWA W
JRC14\53196
RESERV
UATION S
40m WID
225/4/63037 EXISTING
ATER LIN
E
L
H
C0306-JB
C0306-JBL-EUT-DG-36525
E
C
FOR CONTINUATION SE
T
H H
M A
MATCH LINE
LEGEND:
ETIHAD RAIL ALIGNMENT
ETIHAD RAIL RIGHT OF WAY
RTA RIGHT OF WAY EXISTING ETISALAT
UTILITY CORRIDOR MANHOLE
DUBAI METRO CORRIDOR JRC14\53195
PROPOSED UTILITY CORRIDOR
ETIHAD RAIL FENCE
RTA FENCE
J SAND MITIGATION J
ETIHAD RAIL EARTHWORK
LINESIDE ACCESS GATCH TRACK
MSE WALL
PROPOSED CONCRETE BARRIER
PROPOSED BARRIER TRANSITION
METRO CORRIDOR
DEWA WATER CORRIDOR
DEWA EHV CORRIDOR
PROPOSED ROAD BRIDGE
PROPOSED AT GRADE ROAD
PROPOSED RAMP
PROPOSED INTERLOCK PAVEMENT
K K
EXISTING ROAD TO BE DEMOLISHED
TIMESTAMP : 2/27/2022 3:39:05 PM