Professional Documents
Culture Documents
A A
1x125mmØ HD L
END
E=487962.0E0J0
0
N=2764R908 3/ .00 00
IE 5+
7
CLP
PROP.DN1200 MBV
CHAMBER, MBV-01
PROPOSED 1x125mmØ J
/E
E=488152.1089 HDPE SCADA DUCT IER
9
5+000
JBL
PROPOSED FOC PULL
PIT (PULL PIT SUPPLIED
BY DEWA
F E=488172.210 F
D
N=2764823.652 OA R
PROPOSED FOC PULL D
YE
PIT (PULL PIT SUPPLIED ZA
H
BY DEWA) EIK
E=488265.196 1 SH
E1
RE
DE SERV WIDE
N=2764786.581 TO
RE 0.0m
DE VATI
SE
WA AT )
(4
WA ON
R
WA ION
EH (15
PROPOSED 2x160mmØ +
TE
PROPOSED FOC PULL
V C 2.4
R
G PIT (PULL PIT 1x125mmØ HDPE SCADA G
OR 0m
BY DEWA) N=2764766.321
FR URE
FU
E=488329.738
OZ ME
T
EN TR
PROPOSED Ø1200 GRE SELF N=2764722.183 FRL
FILENAME : D:\ETIHAD RAIL\SHOP DRAWING\DESCON\JBL1B SCADA\2022-11-16 REVISED SD\REV.01\WORKING\C0306-JBL-EUT-DS-00028-R1
FO O
RESTRAINED DEWA WD WATER
R
LINE PROTECTED BY Ø1727 STEEL
LEGEND: SLEEVE WITH GROUT
0.30
ETIHAD RAIL ALIGNMENT
H ETIHAD RAILRIGHT OF WAY WARING TAPE H
RTA RIGHT OF WAY
UTILITY CORRIDOR PROPOSED FOC JOINT
DUBAI METRO CORRIDOR LOCATION-1 AT PROPOSED E ET
ETIHAD RAIL FENCE STR
PULL PIT (PULL PIT SUPPLIED
RTA FENCE YIS
0.85
SAND MITIGATION BY DEWA) ALA
2x160mmØ + 1x125mmØ HDPE LY
ETIHAD RAIL EARTHWORK 7-A
0.50
LINESIDE ACCESS GATCH TRACK SCADA DUCT END D5
E=488481.069
PROPOSED AT GRADE ROAD N=2764656.947
MSE WALL
1. Approved
2. Subject to successfully handover the system to Authorities TILE MARKER
J PROPOSED BARRIER TRANSITION J
0.20
125Ø 0.15
PILE
PROPOSED PILE / PILE CAP PILE CAP
NOTES:
LEGEND: 1. ALL DIMENSIONS ARE IN METER UNLESS OTHERWISE NOTED. SCADA DUCT
IN OPERATION SCADA DUCT 2. COORDINATE REFERENCE SYSTEM DLTM. (HDPE )MATERIAL
IN OPERATION SCADA DUCT TO 3. ALL EXISTING UTILITIES SHOWN WERE OBTAINED FROM THE DEWA GIS SYSTEM.
BE REMOVED 4. ALL UTILITY PROTECTION SHALL EXTEND FROM RAIL ROW TO ROW.
0.10
SAND BEDDING
160Ø
K PROPOSED SCADA DUCT 5. ALL EXISTING PIPES CROSSING THE RAIL ROW SHALL BE REPLACED WITH SELF-RESTRAINED K
IN OPERATION 1200mmØ PIPE GRE PIPES (10,000N/m2 STIFFNESS), LAMINATED JOINTS WITH STEEL SLEEVE.
IN OPERATION 1200mmØ PIPE 6. EXISTING FO CABLE (24F BIRLA CABLE) WILL BE JOINED WITH NEW 24F FO CABLE AT
TO BE REMOVED SCADA DUCT
0.15
PROPOSED JOINT LOCATIONS. (HDPE MATERIAL)
PROPOSED 1200mmØ PIPE
7. ALL FOC JOINT WORKS WILL BE DONE UNDER THE SUPERVISION AND PERMISSION OF DEWA
PROPOSED STEEL SLEEVE FOR
1200Ø WATER LINE
SND DEPARTMENT.
PROPOSED FOC PULL PIT
8. ALL THE PROPOSED PULL PITS WILL BE UNDER DEWA SCOPE. 0.15 160Ø 0.10 160Ø 0.15
9. PROPOSED MBV CONNECTION WITH SCADA UNDER DEWA SCOPE.
EXISTING FOC PULL PIT
10.PRIOR TO THE JOINT AND AFTER THE JOINT EXISTING FOC CABLES WILL BE TESTED AND TYPICAL SECTION FOR
PROPOSED MBV CHAMBER HEALTHNESS WILL BE VERIFIED. PROPOSED SCADA DUCT
L L