TRUE NORTH
KEY PLAN
MANYAR SMELTER
DESALINATION PLANT
A
A
4031
9R13
B
4091
B
DW G-
THIS DRAWING
5465-
DD-
1R15
26300
6165
6030
NUATI
1565 3600
NE FOR CONTI
900mm STR
L90-5437-SJ-226-M, EL. 13850 4. ALL FITTING RADIUS OF CABLE TRAY IS 900mm.
L90-5437-SJ-126-M, EL. 13350
L90-5437-SP-226-M, EL. 12850 5. ALL CABLE TRAY NUMBERS SEPARATED WITH A FORWARD SLASH ( / ) INDICATES A DIVIDED TRAY.
L90-5437-SP-126-S, EL. 12350 ALL DIVIDED TRAYS HAVE THE DIVIDER LOCATION IN THE CENTER LINE OF THE TRAY UNLESS
900mm 90° IVE
OTHER WISE NOTED.
9R08 900mm STR 6. ALL MEDIUM VOLTAGE CABLE TRAY WILL BE SHOWN AT THE SIDE RAIL TRAY WITH
900mm HT
"DANGER - HIGH VOLTAGE - KEEP AWAY" EVERY 15 METERS STRAIGHT SECTIONS.
E (2) 300mm STR
E
L30-5437-SJ-151-M, EL. 15750 L90-5437-SJ-127-M, EL. 9990
7. THE COVERS SHALL BE PROVIDED ON CABLE TRAY INSTALLED OUTDOORS AT THE TOP LAYER OF ALL
L30-5437-SP-251-M, EL. 15250 L90-5437-SP-227-M, EL. 9490 STACKED. COVERS ARE REQUIRED TO PROTECT FROM FALLING OBJECT AND CORROSIVE MATERIALS,
L90-5437-SP-127-S, EL. 8990 DUSTY AREAS, DIRECT SOLAR RADIATION (SUNLIGHT) AND MECHANICAL DAMAGE DURING
MAINTENANCE.
8. THE CONTRACTOR SHALL INSTALL EXPANSION SPLICE PLATES EVERY STRAIGHT RUN CABLE TRAY
SECTION 1
OUTDOOR 50 METERS.
9R07 SCALE: 1:100
(2) 900mm STR 9. THE CONTRACTOR SHALL IDENTIFY TRAY NUMBER AT SIDE RAIL TRAY BY NOT EXCEEDING 15 METERS ON
L90-5437-SJ-122-M, EL. 10810 STRAIGHT SECTIONS AND WITHIN 1.5 METERS OF ALL TRAY INTERSECTION AND NUMBERING CHANGE
L90-5437-SP-222-M, EL. 10310 LOCATIONS. TRAY NUMBER SHALL BE SHOWN ON THE ONE SIDE RAIL TRAY WHERE PERSONAL CAN
EASILY BE SEEN FROM GRADE LEVEL.
MATCHLINE CONTINUATION
10. HORIZONTAL TRAY SHALL BE SUPPORTED AT INTERVALS NOT EXCEEDING 3.0 METERS AND VERTICAL TRAYS
27265
SEE MSD-DD-5437-ELE-DWG-4022 1R13 SHALL BE SUPPORTED AT INTERVALS NOT EXCEEDING 2.5 METERS WHEN MEASURED ALONG
F
F
THE CENTERLINE OF STRAIGHT TRAY SECTION RUNS. STRAIGHT SECTIONS AND FITTINGS SHALL BE
SUPPORTED IN ACCORDANCE WITH THE DETAILS DRAWING MSD-DD-5420-STR-STA-6970 THRU 6976.
9R06
3510
4081
BE BLIND END
DW G-
DO DROPOUT
900mm 30° OVE CABLE TRAY NUMBER
HB HORIZONTAL ELBOW
CHANGE DESIGNATOR
120
900mm STR
HT HORIZONTAL TEE
ELE-
900mm DO
1275
H
H
9R03
(3) 900mm 30° HB
1 315
L90-5437-SJ-130-M, EL. 14350
6500
900mm STR
220
SECTION 3
1R14 9RA 9RB SCALE: 1:100
L90-5437-SJ-240-M, EL. 14350 (4) 900mm STR 3
L90-5437-SJ-140-M, EL. 13850 L90-5437-SJ-226-M, EL. 13850
L90-5437-SP-340-M, EL. 13350 L90-5437-SJ-126-M, EL. 13350 THIS DWG
900mm DO
2500
850
1105 APPROVED FOR
1050
1R12
CONSTRUCTION
480
MATCHLINE FOR CONTINUATION SEE MSD-DD-5436-ELE-DWG-4011 THE DISTRIBUTION AND USE OF THE NATIVE FORMAT CAD
FILE OF THIS DRAWING IS UNCONTROLLED. THE USER
SHALL VERIFY TRACEABILITY OF THIS DRAWING TO THE
K (4) 900mm STR
LATEST CONTROLLED VERSION. K
L90-5437-SJ-225-M, EL. 13850
1RA 1RB 1RC 1RD 1RE 1RF 1RG 1RH 1RI 1RJ L90-5437-SJ-125-M, EL. 13350
L90-5437-SP-225-M, EL. 12850
L90-5437-SP-125-S, EL. 12350
R
E NKT TPG WBA NOV,11,2022 ISSUED FOR OWNER APPROVAL (IFA) Originator Document No: REV. DRAWING NO. REV.
03/31/2023 09:
NO. DRAWN CHECKED APPROVED DATE DESCRIPTION DWG NO. REFERENCE DRAWINGS DWG NO. REFERENCE DRAWINGS 411870-1EEC-E4021 0 MSD-DD-5437-ELE-DWG-4021 0