You are on page 1of 1

Prove Historical Report (First) ID:FUJISAN 21/03/22 13:17 Page 1

OMNI  5  PETROECUADOR

METER PROVING REPORT FOR MASTER METER METHOD Computer ID : FUJISAN

Date : 21/03/22 Time : 14:17:54 Report Number : 2388


Location : B61 AUCA SUR 47
API Table Selected: CrudeOil Product Name : CRUDO
==============================================================================
Master Meter Data :
Serial Number: 14754673 Meter ID : MSTER K Pulses/bbl : 95366.5
Meter Size : 2" 600# Meter Model : CMF200
==============================================================================
Meter Data :
Serial Number: 14430605 Meter ID : FE510501 K Pulses/bbl : 42000
Meter Size : 3"#150 Meter Model : CMF300 Total bbl : 2189838
==============================================================================
Previous M.F. : 1.0000 @ BBL/H : 9600.0 Date : 27/08/20 Time : 10:18:10
==============================================================================
Run #1 Run #2 Run #3 Run #4 Run #5
Master Meter Data
1. Vol bbl 1.00673 1.00225 1.00660 1.00287 1.00724
2. Temperature Deg.C 28.14 27.92 27.77 27.80 27.99
3. Pressure kpa 51 51 52 52 52
4. Density kg/m3 907.9 907.9 907.9 907.9 907.9
5. Meter Factor 1.0000 1.0000 1.0000 1.0000 1.0000
6. CTL .99060 .99077 .99087 .99085 .99071
7. CPL 1.00003 1.00003 1.00003 1.00003 1.00003
8. CCF( Line 5 x 6 x 7) .99063 .99080 .99090 .99088 .99074
9. Corrected Prover Volume .99729 .99303 .99744 .99372 .99791
==============================================================================
Proved Meter Data
10. Vol bbl 1.00676 1.00238 1.00659 1.00293 1.00729
11. Temperature Deg.C 28.14 27.92 27.77 27.80 27.99
12. Pressure kpa 51 51 52 52 52
13. Density kg/m3 907.9 907.9 907.9 907.9 907.9
14. Gros Flow Rate bbl/Hr 58.5 58.7 58.9 59.2 59.4
15. CTL .99060 .99077 .99087 .99085 .99071
16. CPL 1.00003 1.00003 1.00003 1.00003 1.00003
17. CCF( Line 15 x 16) .99063 .99080 .99090 .99088 .99074
18. Corrected Meter Volume .99733 .99316 .99743 .99378 .99796
19. Meter Factor (Line 9 /18) 1.0000 .9999 1.0000 .9999 1.0000
==============================================================================
Maximum MF Deviation % Between Runs .010
Average Meter Factor 1.0000
K Factor New 42001.68 pulses/bbl
Manual prove requested MF is not implemented.

Remarks, Repairs, Adjustments, Etc.,__________________________________________

______________________________________________________________________________

Signature Date Company Represented

_____________________
Firmado electrónicamente por:
________________ _____________________________________
DIEGO ARMANDO
PROANO JARRIN
_____________________ ________________ _____________________________________
OMNI_EOF