T-710 Scope. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132


T-720 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132
T-721 Written Procedure Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132
T-730 Equipment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132
T-731 Examination Medium . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132
T-740 Miscellaneous Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
T-741 Surface Conditioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
T-750 Technique . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
T-751 Techniques . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
T-752 Prod Technique . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
T-753 Longitudinal Magnetization Technique . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
T-754 Circular Magnetization Technique. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135
T-755 Yoke Technique . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135
T-756 Multidirectional Magnetization Technique . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135
T-760 Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136
T-761 Frequency of Calibration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136
T-762 Lifting Power of Yokes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136
T-763 Gaussmeters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136
T-764 Magnetic Field Adequacy and Direction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137
T-765 Wet Particle Concentration and Contamination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
T-766 System Performance of Horizontal Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
T-770 Examination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140
T-771 Preliminary Examination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140
T-772 Direction of Magnetization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140
T-773 Method of Examination. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140
T-774 Examination Coverage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140
T-775 Rectified Current. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140
T-776 Excess Particle Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140
T-777 Interpretation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140
T-778 Demagnetization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141
T-780 Evaluation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141
T-790 Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141
T-791 Multidirectional Magnetization Technique Sketch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141
T-792 Recording of Indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141
T-793 Examination Records . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141
T-794 Performance Demonstration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141

Figures
T-754.2.1 Single-Pass and Two-Pass Central Conductor Technique . . . . . . . . . . . . . . . . . . . . . . . . 136
T-754.2.2 The Effective Region of Examination When Using an Offset Central Conductor. . . 136
T-764.1.1 Pie-Shaped Magnetic Particle Field Indicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137
T-764.1.2 Artificial Flaw Shims. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137
T-766.1 Ketos (Betz) Test Ring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139

129
Table
T-721 Requirements of a Magnetic Particle Examination Procedure. . . . . . . . . . . . . . . . . . . . . 133

Mandatory Appendices
Appendix I Magnetic Particle Examination Using theAC Yoke Technique on
Ferritic Materials Coated With Nonmagnetic Coatings . . . . . . . . . . . . . . . . . . . . . . . . 142
I-710 Scope. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142
I-720 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142
I-721 Written Procedure Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142
I-722 Personnel Qualification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142
I-723 Procedure/Technique Demonstration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142
I-730 Equipment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142
I-740 Miscellaneous Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142
I-741 Coating Thickness Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142
I-750 Technique . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143
I-751 Technique Qualification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143
I-760 Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
I-761 Yoke Maximum Lifting Force. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
I-762 Light Intensity Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
I-770 Examination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
I-780 Evaluation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
I-790 Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
I-791 Examination Record . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
I-792 Performance Demonstration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144

Appendix II Glossary of Terms for Magnetic Particle Examination . . . . . . . . . . . . . . . . . . . . . . . . . . 144


II-710 Scope. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
II-720 General Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
II-730 Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144.1

Appendix III Magnetic Flux Leakage (MFL) Examination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144.2


III-710 Scope. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144.2
III-711 References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144.2
III-720 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144.2
III-721 Personnel Qualification Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144.2
III-722 Equipment Qualification Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144.2
III-723 Written Procedure Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144.2
III-730 Equipment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144.3
III-740 Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144.3
III-760 Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144.4
III-770 Examination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144.4
III-780 Evaluation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144.5
III-790 Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144.5

Figures
III-722.1.1 Reference Plate Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144.3
III-722.1.2 Reference Pipe or Tube Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144.4

Tables
I-721 Requirements of AC Yoke Technique on Coated Ferritic Component. . . . . . . . . . . . . 143
III-723 Requirements of an MFL Examination Procedure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144.4

130
Nonmandatory Appendix
Appendix A Measurement of Tangential Field Strength With Gaussmeters . . . . . . . . . . . . . . . . . . . . 144.6
A-710 Scope. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144.6
A-720 General Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144.6
A-730 Equipment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144.6
A-750 Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144.6
A-790 Documentation/Records . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144.6

131
ARTICLE 7
MAGNETIC PARTICLE EXAMINATION

T-710 SCOPE T-721 Written Procedure Requirements


When specified by the referencing Code Section, the T-721.1 Requirements. Magnetic particle examina-
magnetic particle examination techniques described in tion shall be performed in accordance with a written
this Article shall be used. In general, this Article is in procedure, which shall, as a minimum, contain the
conformance with SE-709, Standard Guide for Magnetic requirements listed in Table T-721. The written proce-
Particle Examination. This document provides details dure shall establish a single value, or range of values,
to be considered in the procedures used. for each requirement.
When this Article is specified by a referencing Code
Section, the magnetic particle method described in this T-721.2 Procedure Qualification. When procedure
Article shall be used together with Article 1, General qualification is specified, a change of a requirement in
Requirements. Definition of terms used in this Article Table T-721 identified as an essential variable from
are in Mandatory Appendix II. the specified value, or range of values, shall require
requalification of the written procedure. A change of
a requirement identified as a nonessential variable from
the specified value, or range of values, does not require
requalification of the written procedure. All changes
of essential or nonessential variables from the value,
T-720 GENERAL or range of values, specified by the written procedure
shall require revision of, or an addendum to, the written
The magnetic particle examination method may be procedure.
applied to detect cracks and other discontinuities on
or near the surfaces of ferromagnetic materials. The
sensitivity is greatest for surface discontinuities and
diminishes rapidly with increasing depth of subsurface T-730 EQUIPMENT
discontinuities below the surface. Typical types of
A suitable and appropriate means for producing the
discontinuities that can be detected by this method are
necessary magnetic flux in the part shall be employed,
cracks, laps, seams, cold shuts, and laminations. using one or more of the techniques listed in and
In principle, this method involves magnetizing an described in T-750.
area to be examined, and applying ferromagnetic parti-
cles (the examination’s medium) to the surface. The
particles will form patterns on the surface where cracks
T-731 Examination Medium
and other discontinuities cause distortions in the normal
magnetic field. These patterns are usually characteristic The finely divided ferromagnetic particles used for
of the type of discontinuity that is detected. the examination shall meet the following requirements.
Whichever technique is used to produce the magnetic (a) Particle Types. The particles shall be treated
flux in the part, maximum sensitivity will be to linear to impart color (fluorescent pigments, nonfluorescent
discontinuities oriented perpendicular to the lines of pigments, or both) in order to make them highly visible
flux. For optimum effectiveness in detecting all types (contrasting) against the background of the surface
of discontinuities, each area is to be examined at least being examined.
twice, with the lines of flux during one examination (b) Particles. Dry and wet particles, including wet
approximately perpendicular to the lines of flux during particle suspension vehicles, and particle concentration
the other. shall be in accordance with SE-709.

132
T-731 ARTICLE 7 — MAGNETIC PARTICLE EXAMINATION T-751

TABLE T-721
REQUIREMENTS OF A MAGNETIC PARTICLE EXAMINATION PROCEDURE
Essential Nonessential
Requirement Variable Variable

Magnetizing Technique X
Magnetizing current type or amperage outside range specified by this
Article or as previously qualified X
Surface preparation X
Magnetic particles (fluorescent/visible, color, particle size, wet/dry) X
Method of particle application X
Method of excess particle removal X
Minimum light intensity X
Coating thickness greater than that qualified X
Performance demonstration, when required X
Examination part surface temperature outside of the
temperature range recommended by the manufacturer of the
particles or as previously qualified X
Shape or size of the examination object X
Equipment of the same type X
Temperature (within those specified by manufacturer
or as previously qualified) X
Demagnetizing technique X
Post examination cleaning technique X
Personnel qualification requirements X

(c) Temperature Limitations. Particles shall be used (c) Cleaning may be accomplished using detergents,
within the temperature range limitations set by the organic solvents, descaling solutions, paint removers,
manufacturer of the particles. Alternatively, particles vapor degreasing, sand or grit blasting, or ultrasonic
may be used outside the particle manufacturer’s recom- cleaning methods.
mendations providing the procedure is qualified in (d) If nonmagnetic coatings are left on the part in
accordance with Article 1, T-150 at the proposed temper- the area being examined, it shall be demonstrated
ature. that indications can be detected through the existing
maximum coating thickness applied. When AC yoke
technique is used, the demonstration shall be in accord-
ance with Mandatory Appendix I of this Article.
T-740 MISCELLANEOUS
REQUIREMENTS T-741.2 Surface Contrast Enhancement. When
nonmagnetic coatings are applied temporarily to un-
T-741 Surface Conditioning coated surfaces only in amounts sufficient to enhance
T-741.1 Preparation particle contrast, it shall be demonstrated that indications
(a) Satisfactory results are usually obtained when can be detected through the enhancement coating.
the surfaces are in the as-welded, as-rolled, as-cast, or NOTE: Refer to T-150(a) for guidance for the demonstration required
as-forged conditions. However, surface preparation by in T-741.1(d) and T-741.2.
grinding or machining may be necessary where surface
irregularities could mask indications due to discontinu-
ities. T-750 TECHNIQUE
(b) Prior to magnetic particle examination, the surface T-751 Techniques
to be examined and all adjacent areas within at least
1 in. (25 mm) shall be dry and free of all dirt, One or more of the following five magnetization
grease, lint, scale, welding flux and spatter, oil, or techniques shall be used:
other extraneous matter that could interfere with the (a) prod technique;
examination. (b) longitudinal magnetization technique;

133
T-751 2001 SECTION V T-753.3

(c) circular magnetization technique; examined in sections not to exceed 18 in. (457 mm),
(d) yoke technique; and 18 in. (457 mm) shall be used for the part L in
(e) multidirectional magnetization technique. calculating the required field strength. For noncylindrical
parts, D shall be the maximum cross-sectional diagonal.
(a) Parts With L /D Ratios Equal to or Greater Than
T-752 Prod Technique 4. The magnetizing current shall be within ±10% of
T-752.1 Magnetizing Procedure. For the prod tech- the ampere-turns’ value determined as follows:
nique, magnetization is accomplished by portable prod
type electrical contacts pressed against the surface in 35,000
Ampere-turns p
the area to be examined. To avoid arcing, a remote (L / D) + 2
control switch, which may be built into the prod handles,
shall be provided to permit the current to be appliedafter For example, a part 10 in. (254 mm) long ⴛ 2 in.
the prods have been properly positioned. (51 mm) diameter has an L /D ratio of 5. Therefore,
T-752.2 Magnetizing Current. Direct or rectified
35,000
magnetizing current shall be used. The current shall p 5000 ampere-turns
(L/D + 2)
be 100 (minimum) amp /in. (3.9 amp/mm) to 125
(maximum) amp /in. (4.9 amp/mm) of prod spacing for
(b) Parts With L /D Ratios Less Than 4 but Not
sections 3⁄4 in. (19 mm) thick or greater. For sections
Less Than 2. The magnetizing ampere-turns shall be
less than 3⁄4 in. (19 mm) thick, the current shall be 90
within ±10% of the ampere-turns’ value determined as
amp /in. (3.5 amp / mm) to 110 amp /in. (4.3 amp / mm) of
follows:
prod spacing.
T-752.3 Prod Spacing. Prod spacing shall not exceed 45,000
Ampere-turns p
8 in. (203 mm). Shorter spacing may be used to L /D
accommodate the geometric limitations of the area
being examined or to increase the sensitivity, but prod (c) Parts With L /D Ratios Less Than 2. Coil magneti-
spacings of less than 3 in. (76 mm) are usually not zation technique cannot be used.
practical due to banding of the particles around the (d) If the area to be magnetized extends beyond 9
prods. The prod tips shall be kept clean and dressed. in. (229 mm) on either side of the coil’s center, field
If the open circuit voltage of the magnetizing current adequacy shall be demonstrated using a magnetic field
source is greater than 25 V, lead, steel, or aluminum indicator or artificial flaw shims per T-764.
(rather than copper) tipped prods are recommended to (e) For large parts due to size and shape, the mag-
avoid copper deposits on the part being examined. netizing current shall be 1200 ampere-turns to 4500
ampere-turns. The field adequacy shall be demonstrated
using artificial flaw shims or a pie-shaped magnetic
T-753 Longitudinal Magnetization Technique field indicator in accordance with T-764. A Hall-Effect
T-753.1 Magnetizing Procedure. For this technique, probe gaussmeter shall not be used with encircling coil
magnetization is accomplished by passing current magnetization techniques.
through a multi-turn fixed coil (or cables) that is
T-753.3 Magnetizing Current. The current required
wrapped around the part or section of the part to be
to obtain the necessary magnetizing field strength shall
examined. This produces a longitudinal magnetic field
be determined by dividing the ampere-turns obtained
parallel to the axis of the coil.
in steps (a) or (b) above by the number of turns in
If a fixed, prewound coil is used, the part shall be
the coil as follows:
placed near the side of the coil during inspection. This
is of special importance when the coil opening is more ampere-turns
than 10 times the cross-sectional area of the part. Amperes (meter reading) p
turns
T-753.2 Magnetic Field Strength. Direct or rectified
current shall be used to magnetize parts examined by For example, if a 5-turn coil is used and the ampere-
this technique. The required field strength shall be turns required are 5000, use
calculated based on the length L and the diameter D
of the part in accordance with (a) and (b), or as 5000
p 1000 amperes (±10%)
established in (d) and (e), below. Long parts shall be 5

134
T-754 ARTICLE 7 — MAGNETIC PARTICLE EXAMINATION T-756.2

T-754 Circular Magnetization Technique an inside wall of the part, the current levels, as given
in T-754.1(b)(1) shall apply, except that the diameter
T-754.1 Direct Contact Technique
used for current calculations shall be the sum of the
(a) Magnetizing Procedure. For this technique, mag-
diameter of the central conductor and twice the wall
netization is accomplished by passing current through
thickness. The distance along the part circumference
the part to be examined. This produces a circular
(exterior) that is effectively magnetized shall be taken
magnetic field that is approximately perpendicular to
as four times the diameter of the central conductor, as
the direction of current flow in the part.
illustrated in Fig. T-754.2.2. The entire circumference
(b) Magnetizing Current. Direct or rectified (half-
shall be inspected by rotating the part on the conductor,
wave rectified or full-wave rectified) magnetizing cur-
allowing for approximately a 10% magnetic field
rent shall be used.
overlap.
(1) The current shall be 300 amp /in. (12 A /mm)
to 800 amp /in. (31 A /mm) of outer diameter.
(2) Parts with geometric shapes other than round T-755 Yoke Technique
with the greatest cross-sectional diagonal in a plane at T-755.1 Application. This method shall only be
right angles to the current flow shall determine the applied to detect discontinuities that are open to the
inches to be used in (b)(1) above. surface of the part.
(3) If the current levels required for (b)(1) cannot
be obtained, the maximum current obtainable shall be T-755.2 Magnetizing Procedure. For this technique,
used and the field adequacy shall be demonstrated in alternating or direct current electromagnetic yokes, or
accordance with T-764. permanent magnet yokes, shall be used.
NOTE: For greater materials 1⁄4 in. (6 mm) or less in thickness,
T-754.2 Central Conductor Technique alternating current yokes are superior to direct or permanent magnet
(a) Magnetizing Procedure. For this technique, a yokes of equal lifting power for the detection of surface discontinuities.
central conductor is used to examine the internal surfaces
of cylindrically or ring-shaped parts. The central conduc- T-756 Multidirectional Magnetization
tor technique may also be used for examining the Technique
outside surfaces of these shapes. Where large diameter
cylinders are to be examined, the conductor shall be T-756.1 Magnetizing Procedure. For this technique,
positioned close to the internal surface of the cylinder. magnetization is accomplished by high amperage power
When the conductor is not centered, the circumference packs operating as many as three circuits that are
of the cylinder shall be examined in increments. Field energized one at a time in rapid succession. The effect
strength measurements in accordance with T-764 shall of these rapidly alternating magnetizing currents is to
be used, to determine the extent of the arc that may produce an overall magnetization of the part in multiple
be examined for each conductor position or the rules directions. Circular or longitudinal magnetic fields may
in (c) below may be followed. Bars or cables, passed be generated in any combination using the various
through the bore of a cylinder, may be used to induce techniques described in T-753 and T-754.
circular magnetization. T-756.2 Magnetic Field Strength. Only three phase,
(b) Magnetizing Current. The field strength required full-wave rectified current shall be used to magnetize
shall be equal to that determined in T-754.1(b) for a the part. The initial magnetizing current requirements
single-turn central conductor. The magnetic field will for each circuit shall be established using the previously
increase in proportion to the number of times the central described guidelines (see T-753 and T-754). The ade-
conductor cable passes through a hollow part. For quacy of the magnetic field shall be demonstrated using
example, if 6000 amperes are required to examine a artificial flaw shims or a pie-shaped magnetic particle
part using a single pass central conductor, then 3000 field indicator in accordance with T-764. A Hall-Effect
amperes are required when 2 passes of the through- probe gaussmeter shall not be used to measure field
cable are used, and 1200 amperes are required if 5 adequacy for the multidirectional magnetization tech-
passes are used (see Fig. T-754.2.1). When the central nique. An adequate field shall be obtained in at least
conductor technique is used, magnetic field adequacy two nearly perpendicular directions, and the field intensi-
shall be verified using a magnetic particle field indicator ties shall be balanced so that a strong field in one
in accordance with T-764. direction does not overwhelm the field in the other
(c) Offset Central Conductor. When the conductor direction. For areas where adequate field strengths
passing through the inside of the part is placed against cannot be demonstrated, additional magnetic particle

135
T-756.2 2001 SECTION V T-763

FIG. T-754.2.1 SINGLE-PASS AND TWO-PASS CENTRAL CONDUCTOR TECHNIQUE

Central conductor least three different current output levels encompassing


Effective
region 4d the usable range.
(c) Tolerance. The unit’s meter reading shall not
deviate by more than ±10% of full scale, relative to
the actual current value as shown by the test meter.
d
T-761.2 Light Meters. Light meters, both visible
and fluorescent (black) light meters, shall be calibrated
at least once a year or whenever the meter has been
repaired. If meters have not been in use for one year
or more, calibration shall be done before being used.

T-762 Lifting Power of Yokes


FIG. T-754.2.2 THE EFFECTIVE REGION OF
EXAMINATION WHEN USING AN OFFSET CENTRAL (a) Prior to use, the magnetizing power of electro-
CONDUCTOR magnetic yokes shall have been checked within the
past year. The magnetizing power of permanent mag-
netic yokes shall be checked daily prior to use. The
magnetizing power of all yokes shall be checked when-
ever the yoke has been damaged or repaired.
techniques shall be used to obtain the required two-
directional coverage. (b) Each alternating current electromagnetic yoke
shall have a lifting power of at least 10 lb (4.5 kg)
at the maximum pole spacing that will be used.
T-760 CALIBRATION (c) Each direct current or permanent magnetic yoke
shall have a lifting power of at least 40 lb (18.1 kg)
T-761 Frequency of Calibration at the maximum pole spacing that will be used.
T-761.1 Magnetizing Equipment (d) Each weight shall be weighed with a scale from a
(a) Frequency. Magnetizing equipment with an am- reputable manufacturer and stenciled with the applicable
meter shall be calibrated at least once a year, or nominal weight prior to first use. A weight need only
whenever the equipment has been subjected to major be verified again if damaged in a manner that could
electric repair, periodic overhaul, or damage. If equip- have caused potential loss of material.
ment has not been in use for a year or more, calibration
shall be done prior to first use.
T-763 Gaussmeters
(b) Procedure. The accuracy of the unit’s meter shall
be verified annually by equipment traceable to a national Hall-Effect probe gaussmeters used to verify mag-
standard. Comparative readings shall be taken for at netizing field strength in accordance with T-754 shall

136
T-763 ARTICLE 7 — MAGNETIC PARTICLE EXAMINATION T-764.1.2

FIG. T-764.1.1 PIE-SHAPED MAGNETIC PARTICLE


FIELD INDICATOR

be calibrated at least once a year or whenever the


equipment has been subjected to a major repair, periodic
overhaul, or damage. If equipment has not been in use
for a year or more, calibration shall be done prior to
first use.

T-764 Magnetic Field Adequacy and FIG. T-764.1.2 ARTIFICIAL FLAW SHIMS
Direction
T-764.1 Magnetic Field Adequacy. The applied
magnetic field shall have sufficient strength to produce
satisfactory indications, but shall not be so strong that clearly defined line (or lines) of magnetic particles
it causes masking of relevant indications by nonrelevant form(s) across the copper face of the indicator when
accumulations of magnetic particles. Factors that influ- the magnetic particles are applied simultaneously with
ence the required field strength include the size, shape, the magnetizing force. When a clearly defined line of
and material permeability of the part; the technique of particles is not formed, the magnetizing technique shall
magnetization; coatings; the method of particle applica- be changed as needed. Pie-type indicators are best used
tion; and the type and location of discontinuities to be with dry particle procedures.
detected. When it is necessary to verify the adequacy
T-764.1.2 Artificial Flaw Shims. The shim, shown
of magnetic field strength, it shall be verified by using
in Fig. T-764.1.2, shall be attached to the surface to
one or more of the following three methods.
be examined, such that the artificial flaw side of the
T-764.1.1 Pie-Shaped Magnetic Particle Field shim is toward the inspected surface. A suitable field
Indicator. The indicator, shown in Fig. T-764.1.1, shall strength is indicated when a clearly defined line (or
be positioned on the surface to be examined, such that lines) of magnetic particles, representing the 30% depth
the copper-plated side is away from the inspected flaw, appear(s) on the shim face when magnetic particles
surface. A suitable field strength is indicated when a are applied simultaneously with the magnetizing force.

137
T-764.1.2 2001 SECTION V T-766

When a clearly defined line of particles is not formed, T-765.1 Concentration. Take a 100-mL portion of
the magnetizing technique shall be changed as needed. the suspension from the hose or nozzle, demagnetize
Shim-type indicators are best used with wet particle and allow it to settle for approximately 60 min with
procedures. petroleum distillate suspensions or 30 min with water-
based suspensions before reading. The volume settling
T-764.1.3 Hall-Effect Tangential-Field Probe. A out at the bottom of the tube is indicative of the
gaussmeter and Hall-Effect tangential-field probe shall particle concentration in the bath.
be used for measuring the peak value of a tangential
field. The probe shall be positioned on the surface to T-765.2 Settling Volumes. For fluorescent particles,
be examined, such that the maximum field strength is the required settling volume is from 0.1 to 0.4 mL in
determined. A suitable field strength is indicated when a 100-mL bath sample and from 1.2 to 2.4 mL per
the measured field is within the range of 30 G to 60 100 mL of vehicle for nonfluorescent particles unless
G (2.4 kAm−1 to 4.8 kAm−1) while the magnetizing otherwise specified by the particle manufacturer. Con-
force is being applied. See Article 7, Nonmandatory centration checks shall be made at least every eight
Appendix A. hours.

T-764.2 Magnetic Field Direction. The direction of T-765.3 Contamination. Both fluorescent and non-
magnetization shall be determined by particle indications fluorescent suspensions shall be checked periodically
obtained using an indicator or shims as shown in Fig. for contaminants such as dirt, scale, oil, lint, loose
T-764.1.1 or Fig. T-764.1.2. When a clearly defined fluorescent pigment, water (in the case of oil suspen-
line of particles is not formed in the desired direction, sions), and particle agglomerates which can adversely
the magnetizing technique shall be changed as needed. affect the performance of the magnetic particle examina-
tion process. The test for contamination shall be per-
T-764.2.1 For multidirectional magnetization tech- formed at least once per week.
niques, the orientation of the lines of flux shall be in (a) Carrier Contamination. For fluorescent baths, the
at least two nearly perpendicular directions. When liquid directly above the precipitate should be examined
clearly defined lines of particles are not formed in at least with black light. The liquid will have a little fluores-
two nearly perpendicular directions, the magnetizing cence. Its color can be compared with a freshly made-
technique shall be changed as needed. up sample using the same materials or with an unused
sample from the original bath that was retained for
T-764.3 Determination of the adequacy and direction this purpose. If the “used” sample is noticeably more
of magnetizing fields using magnetic field indicators or fluorescent than the comparison standard, the bath shall
artificial flaw shims are only permitted when specifically be replaced.
referenced by the magnetizing techniques in T-753.2(d), (b) Particle Contamination. The graduated portion
T-753.2(e), T-754.1(b)(3), T-754.2(a), T-754.2(b), and of the tube shall be examined under black light if the
T-756.2. bath is fluorescent and under visible light (for both
fluorescent and nonfluorescent particles) for striations
or bands, differences in color or appearance. Bands or
striations may indicate contamination. If the total volume
T-765 Wet Particle Concentration and of the contaminates, including bands or striations ex-
Contamination ceeds 30% of the volume magnetic particles, or if
Wet Horizontal Units shall have the bath concentra- the liquid is noticeably fluorescent, the bath shall be
tion and bath contamination determined by measuring replaced.
its settling volume. This is accomplished through the
use of an ASTM Test Method D 96 pear-shaped
centrifuge tube with a 1-mL stem (0.05-mL divisions)
T-766 System Performance of Horizontal
for fluorescent particle suspensions or a 1.5-mL stem
Units
(0.1-mL divisions) for nonfluorescent suspensions. Be-
fore sampling, the suspension should be run through The Ketos (Betz) ring specimen (see Fig. T-766.1)
the recirculating system for at least 30 min to ensure shall be used in evaluating and comparing the overall
thorough mixing of all particles which could have performance and sensitivity of both dry and wet, fluo-
settled on the sump screen and along the sides or rescent and nonfluorescent magnetic particle techniques
bottom of the tank. using a central conductor magnetization technique.

138
T-766 ARTICLE 7 — MAGNETIC PARTICLE EXAMINATION T-766

3/ in. (1.91 cm)


4
Typ.
125
1 2
3
4
5
11/4 in. 6 5 in.
(3.18 cm) (12.70
7 cm)
8
12 9
D 11 10

7/ in.
8
(2.22 cm)

Hole 1 2 3 4 5 6 7 8 9 10 11 12

Diameter 0.07 0.07 0.07 0.07 0.07 0.07 0.07 0.07 0.07 0.07 0.07 0.07
[Note (1)] (0.18 (0.18 (0.18 (0.18 (0.18 (0.18 (0.18 (0.18 (0.18 (0.18 (0.18 (0.18
cm) cm) cm) cm) cm) cm) cm) cm) cm) cm) cm) cm)

“D” 0.07 0.14 0.21 0.28 0.35 0.42 0.49 0.56 0.63 0.70 0.77 0.84
[Note (2)] (0.18 (0.36 (0.53 (0.71 (0.90 (1.08 (1.26 (1.44 (1.62 (1.80 (1.98 (2.16
cm) cm) cm) cm) cm) cm) cm) cm) cm) cm) cm) cm

NOTES:
(1) All hole diameters are ±0.005 in. (±0.01 cm.) Hole numbers 8 through 12 are optional.
(2) Tolerance on the D distance is ±0.005 in. (±0.01 cm).
GENERAL NOTES:
(a) All dimensions are ±0.03 in. (±0.08) or as noted in Notes (1) and (2).
(b) All dimensions are in inches, except as noted.
(c) Material is ANSI 01 tool steel from annealed round stock.
(d) The ring may be heat treated as follows: Heat to 1400°F to 1450°F (760°C to 790°C). Hold at this temperature for one hour. Cool
to a minimum rate of 40°F/h (22°C/h) to below 1000°F (540°C). Furnace or air cool to room temperature. Finish the ring to RMS
25 and protect from corrosion.

FIG. T-766.1 KETOS (BETZ) TEST RING

(a) Ketos (Betz) Test Ring Material. The tool steel 11⁄4 in. (25 to 31 mm) diameter hole located in the
(Ketos) ring should be machined from AISI 01 material ring center. The conductor should have a length greater
in accordance with Fig. T-766.1. Either the machined than 16 in. (400 mm). The currents used shall be 1400,
ring or the steel blank should be annealed at 1650°F 2500, and 3400 amps. The minimum number of holes
(900°C), cooled 50°F (28°C) per hour to 1000°F (540°C) shown shall be three, five, and six, respectively. The
and then air cooled to ambient temperature to give ring edge should be examined with either black light
comparable results using similar rings that have had or visible light, depending on the type of particles
the same treatment. Material and heat treatment are involved. This test shall be run at the three amperages
important variables. Experience indicates controlling if the unit will be used at these or higher amperages.
the softness of the ring by hardness (90 to 95 HRB) The amperage values stated shall not be exceeded in
alone is insufficient. the test. If the test does not reveal the required number
(b) Using the Test Ring. The test ring (see Fig. T- of holes, the equipment shall be taken out of service
766.1), is circularly magnetized with full-wave rectified and the cause of the loss of sensitivity determined and
AC passing through a central conductor with a 1 to corrected. This test shall be run at least once per week.

139
T-770 2001 SECTION V T-777.2

T-770 EXAMINATION (b) The amperage required with three-phase, full-


wave rectified current shall be verified by measuring
T-771 Preliminary Examination
the average current.
Before the magnetic particle examination is con- (c) The amperage required with single-phase (half-
ducted, a check of the examination surface shall be wave rectified) current shall be verified by measuring
conducted to locate any discontinuity surface openings the average current output during the conducting half
which may not attract and hold magnetic particles cycle only.
because of their width. (d) When measuring half-wave rectified current with
a direct current test meter, readings shall be multiplied
by two.
T-772 Direction of Magnetization
At least two separate examinations shall be performed
on each area. During the second examination, the lines T-776 Excess Particle Removal
of magnetic flux shall be approximately perpendicular
Accumulations of excess dry particles in examinations
to those used during the first examination. A different
shall be removed with a light air stream from a bulb
technique for magnetization may be used for the second
or syringe or other source of low pressure dry air. The
examination.
examination current or power shall be maintained while
removing the excess particles.
T-773 Method of Examination
The ferromagnetic particles used in an examination
T-777 Interpretation
medium can be either wet or dry, and may be either
fluorescent or nonfluorescent. Examination(s) shall be The interpretation shall identify if an indication as
done by the continuous method. false, nonrelevant, or relevant. False and nonrelevant
(a) Dry Particles. The magnetizing current shall re- indications shall be proven as false or nonrelevant.
main on while the examination medium is being applied Interpretation shall be carried out to identify the loca-
and while any excess of the examination medium is tions of indications and the character of the indication.
removed.
(b) Wet Particles. The magnetizing current shall be T-777.1 Visible (Color Contrast) Magnetic Parti-
turned on after the particles have been applied. Flow cles. Surface discontinuities are indicated by accumula-
of particles shall stop with the application of current. tions of magnetic particles which should contrast with
Wet particles applied from aerosol spray cans may be the examination surface. The color of the magnetic
applied before and/or after magnetizing current is ap- particles shall be sufficiently different than the color
plied. Wet particles may be applied during the applica- of the examination surface. A minimum light intensity
tion of magnetizing current if they are not applied of 100 fc (1000 Lx) is required on the surface to be
directly to the examination area and are allowed to examined to ensure adequate sensitivity during the
flow over the examination area or are applied directly examination and evaluation of indications. The light
to the examination area with low velocities insufficient source, technique used, and light level verification is
to remove accumulated particles. required to be demonstrated one time, documented, and
maintained on file.

T-774 Examination Coverage T-777.2 Fluorescent Magnetic Particles. With fluo-


rescent magnetic particles, the process is essentially
All examinations shall be conducted with sufficient the same as in T-777.1, with the exception that the
field overlap to ensure 100% coverage at the required examination is performed using an ultraviolet light,
sensitivity (T-764). called black light. The examination shall be performed
as follows:
(a) It shall be performed in a darkened area.
T-775 Rectified Current
(b) The examiner shall be in the darkened area for
(a) Whenever direct current is required rectified cur- at least 5 min prior to performing the examination to
rent may be used. The rectified current for magnetization enable their eyes to adapt to dark viewing. If the
shall be either three-phase (full-wave rectified) current, examiner wears glasses or lenses, they shall not be
or single phase (half-wave rectified) current. photosensitive.

140
T-777.2 ARTICLE 7 — MANDATORY APPENDICES T-794

(c) The black light shall be allowed to warm up for arrangement and connections, magnetizing current for
a minimum of 5 min prior to use or measurement of each circuit, and the areas of examination where ade-
the intensity of the ultraviolet light emitted. Reflectors quate field strengths are obtained. Parts with repetitive
and filters should be checked and cleaned daily when geometries, but different dimensions, may be examined
in use. Cracked or broken filters shall be replaced using a single sketch provided that the magnetic field
immediately. strength is adequate when demonstrated in accordance
(d) The black light intensity shall be measured with with T-755.2.
a black light meter. A minimum of 1000 ␮W /cm2 on
the surface to be examined is required. The black light
intensity shall be verified at least once every 8 hr, T-792 Recording of Indications
whenever the work station is changed, or whenever
the bulb is changed. T-792.1 Nonrejectable Indications. Nonrejectable
indications shall be recorded as specified by the referenc-
ing Code Section.
T-778 Demagnetization
T-792.2 Rejectable Indications. Rejectable indica-
When residual magnetism in the part could interfere tions shall be recorded. As a minimum, the type of
with subsequent processing or usage, the part shall indications (linear or rounded), location and extent
be demagnetized any time after completion of the (length or diameter or aligned) shall be recorded.
examination.

T-780 EVALUATION T-793 Examination Records

(a) All indications shall be evaluated in terms of the For each examination, the following information shall
acceptance standards of the referencing Code Section. be recorded:
(b) Discontinuities on or near the surface are indi- (a) procedure identification and revision;
cated by retention of the examination medium. However, (b) magnetic particle equipment and type of current;
localized surface irregularities due to machining marks (c) magnetic particles (visible or fluorescent, wet
or other surface conditions may produce false indica- or dry);
tions. (d) examination personnel identity and if required
(c) Broad areas of particle accumulation, which might by referencing Code Section, qualification level;
mask indications from discontinuities, are prohibited, (e) map or record of indications per T-792;
and such areas shall be cleaned and reexamined. (f) material and thickness;
(g) lighting equipment; and
(h) date and time examinations were performed.
T-790 DOCUMENTATION
T-791 Multidirectional Magnetization
Technique Sketch T-794 Performance Demonstration
A technique sketch shall be prepared for each different Performance demonstration, when required by the
geometry examined, showing the part geometry, cable referencing Code Section, shall be documented.

141
ARTICLE 7
MANDATORY APPENDICES

A03 APPENDIX I — MAGNETIC I-722 Personnel Qualification


PARTICLE EXAMINATION USING Personnel qualification requirements shall be in ac-
THE AC YOKE TECHNIQUE ON cordance with the referencing Code Section.
FERRITIC MATERIALS COATED
WITH NONMAGNETIC COATINGS
I-723 Procedure/Technique Demonstration
I-710 SCOPE
The procedure/technique shall be demonstrated to
This Appendix provides the Magnetic Particle exami- the satisfaction of the Inspector in accordance with the
nation methodology and equipment requirements appli- requirements of the referencing Code Section.
cable for performing Magnetic Particle examination on
ferritic materials with nonmagnetic coatings.
I-730 EQUIPMENT
I-730.1 The magnetizing equipment shall be in ac-
cordance with Article 7.
I-720 GENERAL
I-730.2 When the dry powder technique is used, a
Requirements of Article 7 apply unless modified by powder blower shall be utilized for powder application.
this Appendix. Hand squeezed particle applicators shall not be used
when the dry powder technique is utilized.
I-730.3 Magnetic particles shall contrast with the
I-721 Written Procedure Requirements component background.
I-721.1 Requirements. Magnetic Particle examina- I-730.4 Nonconductive materials such as plastic shim
tion shall be performed in accordance with a written stock may be used to simulate nonconductive nonmag-
procedure which shall, as a minimum, contain the netic coatings for procedure and personnel qualification.
requirements listed in Tables T-721 and I-721. The
written procedure shall establish a single value, or
range of values, for each requirement. I-740 MISCELLANEOUS
REQUIREMENTS
I-721.2 Procedure Qualification/Technique Valida-
I-741 Coating Thickness Measurement
tion. When procedure qualification is specified, a change
of a requirement in Table T-721 or I-721 identified as The procedure demonstration and performance of
an essential variable from the specfied value, or range examinations shall be preceded by measurement of the
of values, shall require requalification of the written coating thickness in the areas to be examined. If the
procedure and validation of the technique. A change coating is nonconductive, an eddy current technique or
of a requirement identified as an nonessential variable magnetic technique may be used to measure the coating
from the specified value, or range of values, does not thickness. The magnetic technique shall be in accordance
require requalification of the written procedure. All with ASTM D 1186, Standard Test Methods for Nonde-
changes of essential or nonessential variables from the structive Measurement of Dry Film Thickness of Non-
value, or range of values, specified by the written magnetic Coatings Applied to a Ferrous Base. When
procedure shall require revision of, or an addendum coatings are conductive and nonmagnetic, a coating
to, the written procedure. thickness technique shall be used in accordance with

142
I-741 ARTICLE 7 — MANDATORY APPENDICES I-751

TABLE I-721
REQUIREMENTS OF AC YOKE TECHNIQUE ON COATED FERRITIC COMPONENT
Essential Nonessential
Requirement Variable Variable

Identification of surface configurations to be examined, including


coating materials, maximum qualified coating thickness, and
product forms (e.g., base material or welded surface) X
Surface condition requirements and preparation methods X
Manufacturer and model of AC yoke X
Manufacturer and type of magnetic particles X
Minimum and maximum pole separation X
Identification of the steps in performing the examination X
Minimum lighting intensity and AC yoke lifting power requirements
(as measured in accordance with Technique Qualification (I-721.2) X
Methods of identifying flaw indications and discriminating between flaw
indications and false or nonrelevant indications (e.g., magnetic
writing or particles held by surface irregularities) X
Instructions for identification and confirmation of suspected flaw indications X
Method of measuring coating thickeness X
Recording criteria X
Personnel qualification requirements unique to this technique X
Reference to the procedure qualification records X

D 1186. Coating measurement equipment shall be used (2) All the requirements of paragraphs (b) through
in accordance with the equipment manufacturer’s in- (g) are met for the alternate material.
structions. Coating thickness measurements shall be (b) Examine the uncoated specimen in the most
taken at the intersections of a 2 in. (51 mm) maximum unfavorable orientation expected during the performance
grid pattern over the area of examination and at least of the production examination.
one-half the maximum yoke leg separation beyond the (c) Document the measured yoke maximum lifting
examination area. The thickness shall be the mean of power, illumination levels, and the results.
three separate readings within 1⁄4 in. (6 mm) of each (d) Measure the maximum coating thickness on the
intersection. item to be examined in accordance with the requirements
of I-741.
(e) Coat the specimen with the same type of coating,
I-750 TECHNIQUE conductive or nonconductive, to the maximum thickness
measured on the production item to be examined.
I-751 Technique Qualification
Alternately, nonconductive shim stock may be used to
(a) A qualification specimen is required. The speci- simulate nonconductive coatings.
men shall be of similar geometry or weld profile and (f) Examine the coated specimen in the most unfavor-
contain at least one surface crack no longer than the able orientation expected during the performance of
maximum flaw size allowed in the applicable acceptance the production examination. Document the measured
criteria. The material used for the specimen shall be yoke maximum lifting power, illumination level, and
the same specification and heat treatment as the coated examination results.
ferromagnetic material to be examined. As an alternative (g) Compare the length of the indication resulting
to the material requirement, other materials and heat from the longest flaw no longer than the maximum
treatments may be qualified provided: flaw size allowed by the applicable acceptance criteria,
(1) The measured yoke maximum lifting force on before and after coating. The coating thickness is
the material to be examined is equal to or greater than qualified when the length of the indication on the
the maximum lifting force on the qualification specimen coated surface is at least 50% of the length of the
material. Both values shall be determined with the same corresponding indication prior to coating.
or comparable equipment and shall be documented as (h) Requalification of the procedure is required for
required in paragraph (c). a decrease in either the AC yoke lifting power or the

143
I-751 2001 SECTION V II-720

illumination level, or for an increase in the coating I-780 EVALUATION


thickness.
If an indication greater than 50% of the maximum
allowable flaw size is detected, the coating in the area
of the indication shall be removed and the examination
I-760 CALIBRATION repeated.
I-761 Yoke Maximum Lifting Force
The maximum lifting force of the AC yoke shall be
I-790 DOCUMENTATION
determined at the actual leg separation to be used in
the examination. This may be accomplished by holding I-791 Examination Record
the yoke with a 10 lb ferromagnetic weight between
For each examination, the information required in
the legs of the yoke and adding additional weights,
the records section of T-793 and the following informa-
calibrated on a postage or other scale, until the ferromag-
tion shall be recorded:
netic weight is released. The lifting power of the yoke
(a) identification of the procedure/technique
shall be the combined weight of the ferromagnetic
(b) identification of the personnel performing and
material and the added weights, before the ferromagnetic
witnessing the qualification
weight was released. Other methods may be used such
(c) description and drawings or sketches of the quali-
as a load cell.
fication specimen, including coating thickness measure-
ments and flaw dimensions
I-762 Light Intensity Measurement (d) equipment and materials used
(e) illumination level and yoke lifting power
The black light or white light intensity (as appropriate)
on the surface of the component shall be no less (f) qualification results, including maximum coating
than that used in the qualification test. An appropriate thickness and flaws detected.
calibrated black light and/or white light meter shall be
used for the tests. Minimum white light or black light I-792 Performance Demonstration
intensities shall meet the requirements of T-777.1 or
T-777.2 as applicable. Performance demonstration, when required by the
referencing Code Section, shall be documented.
I-762.1 White Light. The white light intensity shall
be measured at the inspection surface. The white light
intensity for the examination shall be no less than what APPENDIX II — GLOSSARY OF
was used in the qualification. TERMS FOR
I-762.2 Black Light. The black light intensity shall MAGNETIC PARTICLE
be measured at the distance from the black light in EXAMINATION
the procedure qualification and at the same distance
II-710 SCOPE
on the examination specimen. The black light intensity
shall be no less than that used to qualify the procedure. This Mandatory Appendix is used for the purpose
In addition, the maximum white light intensity shall of establishing standard terms and definition of terms
be measured as background light on the inspection which appear in Article 7, Magnetic Particle Exami-
surface. The background white light for the examination nation.
shall be no greater than what was used in the qualifi-
cation.
II-720 GENERAL REQUIREMENTS
(a) The Standard Terminology for Nondestructive
I-770 EXAMINATION
Examinations (ASTM E 1316) has been adopted by
(a) Surfaces to be examined, and all adjacent areas the Committee as SE-1316.
within at least 1 in. (25 mm), shall be free of all dirt, (b) SE-1316 Section 7 provides the definitions of
grease, lint, scale, welding flux and spatter, oil, and terms listed in II-730(a).
loose, blistered, flaking, or peeling coating. (c) For general terms, such as Indication, Flaw,
(b) Examine the coated item in accordance with the Discontinuity, Evaluation, etc., refer to Article 1, Man-
qualified procedure. datory Appendix I.

144
II-720 ARTICLE 7 — MANDATORY APPENDICES II-730

(d) Paragraph II-730(b) provides a list of terms and the number of flux lines crossing a unit area taken at
definitions, which are in addition to SE-1316 and are right angles to the direction of the lines.
Code specific. rectified magnetic current — by means of a device
called a rectifier, which permits current to flow in one
direction only, alternating current can be converted to
A03 II-730 REQUIREMENTS unidirectional current. This differs from direct current
in that the current value varies from a steady level.
(a) The following SE-1316 terms are used in conjunc- This variation may be extreme, as in the case of the
tion with this Article: ampere turns, black light, central half-wave rectified single phase AC, or slight, as in
conductor, circular magnetization, demagnetization, dry the case of three-phase rectified AC.
powder, full-wave direct current, half-wave current, half-wave rectified current AC — when a single-
longitudinal magnetization, magnetic field, magnetic phase alternating current is rectified in the simplest
field strength, magnetic particle examination, magnetic manner, the reverse of the cycle is blocked out entirely.
particle field indicator, magnetic particles, multidirec- The result is a pulsating unidirectional current with
tional magnetization, permanent magnet, prods, sensitiv- intervals when no current at all is flowing. This is
ity, suspension, yoke. often referred to as “half-wave” or pulsating direct
(b) The following Code terms are used in conjunction current.
with this Article: full-wave rectified current — when the reverse half
black light intensity — a quantitative expression of of the cycle is turned around to flow in the same
ultraviolet irradiance direction as the forward half. The result is full-wave
magnetic flux — the concept that the magnetic field rectified current. Three-phase alternating current when
is flowing along the lines of force suggests that these full-wave rectified is unidirectional with very little
lines are therefore “flux” lines, and they are called pulsation; only a ripple of varying voltage distinguishes
magnetic flux. The strength of the field is defined by it from straight DC single-phase.

144.1
01 ARTICLE 7 — APPENDIX III
A03
MAGNETIC FLUX LEAKAGE (MFL) EXAMINATION

III-710 SCOPE the manufacturer’s specifications prior to use. The refer-


ence specimen for plate shall consist of a plate that
This Appendix describes the Magnetic Flux Leakage
is made from a material of the same nomial thickness,
(MFL) examination method equipment requirements
product form, and composition as the component to
applicable for performing MFL examinations on coated
be examined. The plate specimen shall have notches,
and uncoated ferromagnetic materials from one surface.
or other discontinuities machined into the bottom of
MFL is used in the examination of tube and piping
the plate, as shown in Fig. III-722.1.1. The reference
to find unwelded areas of longitudinal weld joints. It
specimen for pipe or tubing shall consist of a pipe or
is also used as a post construction examination method
tube that is made from a material of the same nominal
to evaluate the condition of plate materials, such as
pipe or tube sizes, product form, and composition as
storage tank floors, and piping for corrosion or other
the component to be examined. The pipe or tube
forms of degradation. Other imperfections that may be
specimen shall have notch discontinuities machined into
detected are cracks, seams, incomplete fusion, incom-
the inside and outside surfaces as shown in Fig. III-
plete penetration, dents, laps, and nonmetallic inclu-
722.1.2. The depths and widths of the artificial disconti-
sions, etc.
nuities should be similar to the sizes and physical
characteristics of discontinuities to be detected. If non-
III-711 References magnetic coatings or temporary coverings will be pres-
ent during the examination, the reference specimen
When the Magnetic Flux Leakage method of Article shall be coated or covered with the nonmagnetic coatings
7, Appendix III is specified by a referencing Code or covers representative of the maximum thickness that
Section, the MFL method shall be used together with will be encountered during the examination.
Article 1, General Requirements.
III-722.2 System Verification and Function
Checks. The manufacturer’s verification procedure shall
III-720 GENERAL be conducted initially to ensure that the system is
functioning as designed. The functional check shall be
III-721 Personnel Qualification Requirements made by scanning the reference plate over the range
The user of this Appendix shall be responsible for of scanning speeds to be utilized during the examination.
documented training, qualification, and certification of Equipment settings shall be documented.
personnel performing MFL examination. Personnel per- III-722.3 Performance Confirmation. A functional
forming supplemental examinations, such as ultrasonic check shall be conducted at the beginning and end of
(UT) examinations, shall be qualified in accordance each examination, every eight hours, or when equipment
with the referencing Code Section. has malfunctioned and been repaired. If it is determined
that the equipment is not functioning properly, needed
III-722 Equipment Qualification Requirements adjustments shall be made and all areas examined since
the last performance check shall be reexamined.
The equipment operation shall be demonstrated by
successfully completing the unit verification and func-
tion tests outlined as follows. III-723 Written Procedure Requirements
III-722.1 Reference Specimen. All MFL examina- III-723.1 Requirements. Magnetic Flux Leakage ex-
tions shall have a reference plate or pipe section to amination shall be performed in accordance with a
ensure the equipment is performing in accordance with written procedure that shall, as a minimum, contain

144.2
III-723.1 ARTICLE 7 — MANDATORY APPENDICES III-740.2

Plate Hole Number Step Size Diameter Diameter Diameter Diameter Diameter
Thickness Number of Steps D1 D2 D3 D4 D5
.25 (6) 1 3 .032 (0.8) .47 (12) .32 (8) .12 (3)
2 4 .032 (0.8) .62 (16) .47 (12) .32 (8) .12 (3)

.31 (8) 1 4 .032 (0.8) .62 (16) .47 (12) .32 (8) .16 (4)
2 5 .032 (0.8) .78 (20) .62 (16) .47 (12) .32 (8) .16 (4)

.38 (10) 1 4 .039 (1) .78 (20) .59 (15) .39 (10) .2 (5)
2 5 .039 (1) .96 (24.5) .78 (20) .59 (15) .39 (10) .2 (5)

D1
30 (762)
D2
6 (152) 12 (305)

9 (229) D3 Step
Holes 1 2
Typical 3-Step Pit
18 (457)
Hole %Loss
1 40%
2 50%

GENERAL NOTE: Dimensions of references are in in. (mm).

FIG. III-722.1.1 REFERENCE PLATE DIMENSIONS A03

the requirements listed in Table III-723. The written III-730 EQUIPMENT


procedure shall establish a single value, or range of
The equipment shall consist of magnets, sensor or
values, for each requirement.
sensor array, and related electronic circuitry. A reference
The procedure shall address, as a minimum, the
indicator, such as a ruled scale or linear array of
identification of imperfections, reference materials used
illuminated light emitting diodes, should be used to
to set up equipment, location and mapping of imperfec-
provide a means for identifying the approximate lateral
tions, and the extent of coverage. The procedure shall
position of indications. The equipment may be designed
address the field strength of the magnets, the functioning
for manual scanning or may be motor driven. Software
of the sensors and the operation of the signal-processing
may be incorporated to assist in detection and character-
unit. Other examination methods that will be used to
ization of discontinuities.
supplement the MFL examination shall be identified
in the procedure.
III-723.2 Procedure Qualification. When procedure III-740 REQUIREMENTS
qualification is specified, a change of a requirement in
III-740.1 The surface shall be cleaned of all loose
Table III-723, identified as an essential variable from
scale and debris that could interfere with the examination
the specified value, or range of values, shall require
and movement of the scanner. The surface should be
requalification of the written procedure. A change in
sufficiently flat to minimize excessive changes in lift-
a requirement identified as a nonessential variable from
off and vibration. Alternate techniques will be required
the specified value, or range of values, does not require
to handle variables exceeding those specified in the
requalification of the written procedure. All changes
procedure.
of essential or nonessential variables from the value,
or range of values, specified by the written procedure III-740.2 Cleaning may be accomplished using high-
shall require revision of or an addendum to the written pressure water blast or by sandblasting. If the material
procedure. is coated and the coating is not removed, it shall be

144.3
III-740.2 2001 SECTION V III-770.1

Typical Block Dimensions Specific Notch Dimensions


Minimum length L 8 in. or 8T, whichever Length L – 1 in. (25 mm) maximum
is greater Depth D – 10% T with tolerance
Full circumference (+10% – 20%) of depth
Width – 0.010 in. (0.25 mm) maximum
Location – not closer than 3T from any
block edge or other notch in axial direction
Minimum 90 deg from adjacent notch(es)

FIG. III-722.1.2 REFERENCE PIPE OR TUBE DIMENSIONS

demonstrated that the MFL equipment can detect the


specified imperfections through the maximum thickness
TABLE III-723 of the temporary sheet or coating.
REQUIREMENTS OF AN MFL EXAMINATION
PROCEDURE III-740.3 If a temporary sheet or coating is applied
Non-
between the scanner and plate to provide a smooth
Essential Essential surface, for example, on a heavily pitted surface, it
Requirement Variable Variable shall be demonstrated that the equipment can find the
specified imperfections through the maximum thickness
Equipment manufacturer/model X
Sensor type: manufacturer and model X
of the temporary sheet or coating.
Scanning speed/speed range X
Overlap X
Lift-off X
Material examined X III-760 CALIBRATION
Material thickness range and dimensions X
Reference specimen and X The MFL equipment shall be recalibrated annually
calibration materials and whenever the equipment is subjected to major
Software X damage following required repairs. If equipment has
Evaluation of indications X not been in use for a year or more, calibration shall
Surface conditioning X
be done prior to first use.
Coating/sheet thickness X
Performance demonstration requirements, X
when required
Scanning technique (remote X
control/manual) III-770 EXAMINATION
Scanning equipment/fixtures X
Personnel qualification requirements X
III-770.1 Areas to be examined shall be scanned in
accordance with a written procedure. Each pass of the

144.4
III-770.1 ARTICLE 7 — NONMANDATORY APPENDIX III-790

sensing unit shall be overlapped in accordance with III-790 DOCUMENTATION


the written procedure.
A report of the examination shall contain the follow-
III-770.2 The unit shall be scanned manually or by ing information:
a motor driven system. Other examination methods (a) plate material specification, nominal wall thick-
may be used to provide coverage in areas not accessible ness, pipe diameter, as applicable;
to MFL examinations, in accordance with the written (b) description, such as drawing/sketches, document-
procedure. Typical examples of inaccessible areas in ing areas examined, and/or areas inaccessible;
storage tanks are lap welds and corner welds adjacent (c) identification of the procedure used for the exami-
to the shell or other obstructions, such as roof columns nation;
and sumps. (d) system detection sensitivity (minimum size of
III-770.3 Imperfections detected with MFL exceeding imperfections detectable);
the acceptance standard signal shall be confirmed by (e) location, depth, and type of all imperfections that
supplemental examination(s) or be rejected. Supplemen- meet or exceed the reporting criteria;
tal examination shall be performed in accordance with (f) examination personnel identity, and, when re-
written procedures. quired by referencing Code Section, qualification level;
(g) model and serial number of equipment utilized
III-770.4 Where detection of linear imperfections is for the examination, including supplemental equipment;
required, an additional scan shall be performed in (h) date and time of examination;
a direction approximately perpendicular to the initial (i) date and time of performance verification
scanning direction. checks and;
(j) supplemental methods utilized and reference to
associated reports.
III-780 EVALUATION
All indications shall be evaluated in accordance with
the referencing Code Section.

144.5
ARTICLE 7
NONMANDATORY APPENDIX

APPENDIX A — MEASUREMENT A-750 PROCEDURE A03


OF TANGENTIAL FIELD STRENGTH Care shall be exercised when measuring the tangential
WITH GAUSSMETERS applied field strengths specified in T-764.1.3. The plane
A-710 SCOPE of the probe must be perpendicular to the surface of
the part at the location of measurement to within 5
This Nonmandatory Appendix is used for the purpose deg. This may be difficult to accomplish by hand
of establishing procedures and equipment specifications orientation. A jig or fixture may be used to ensure
for measuring the tangential applied magnetic field this orientation is achieved and maintained.
strength. The direction and magnitude of the tangential field
on the part surface can be determined by placing the
Hall-Effect tangential field probe on the part surface
A-720 GENERAL REQUIREMENTS in the area of interest. The direction of the field can
be determined during the application of the magnetizing
Personnel qualification requirements shall be in ac- field by rotating the tangential field probe while in
cordance with Article 1. contact with the part until the highest field reading is
Gaussmeters and related equipment shall be calibrated obtained on the Gaussmeter. The orientation of the
in accordance with T-763 of Article 7. probe, when the highest field is obtained, will indicate
Definitions: standard terminology for magnetic parti- the field direction at that point. Gaussmeters cannot be
cle examinations is presented in SE-1316. used to determine the adequacy of magnetizing fields
for multidirectional and coil magnetization techniques.
Once adequate field strength has been demonstrated
A-730 EQUIPMENT with artificial flaw shims, Gaussmeter readings may be
used at the location of shim attachment on identical
Gaussmeter having the capability of being set to parts or similar configurations to verify field intensity
read peak values of field intensity. The frequency and direction.
response of the gaussmeter shall be at least 0 Hz to
300 Hz.
The Hall-Effect tangential field probe should be no A-790 DOCUMENTATION/RECORDS
larger than 0.2 in. (5 mm) by 0.2 in. (5 mm) and
should have a maximum center location 0.2 in. (5 mm) Documentation should include the following:
from the part surface. Probe leads shall be shielded or (a) equipment model and probe description;
twisted to prevent reading errors due to voltage induced (b) sketch or drawing showing where measurements
during the large field changes encountered during mag- are made; and
netic particle examinations. (c) field intensity and direction of measurement.