7. ALL FLOOR DRAINS SHALL HAVE RODDING ACCESS AND SHALL CEILING CLEAN OUT
ACOUSTIC LAGGING OF DRAINAGE PIPING NOTE:
INCORPORATE HEAVY DUTY COVERS TO THE ARCHITECT'S
ACTUAL SIZE TO BE FIELD COFIRMED 600X600 DRAINAGE MANHOLE
ALL HORIZONTAL uPVC SOIL AND WASTE PIPES SHALL BE PROVIDED WITH ACOUSTIC LAGGING AS DETAILED BELOW : APPROVAL.
CLOTH, QUILTED TOGETHER IN A MATRIX OF 100mm DIAMOND STITCH PATTERN WHICH ENCAPSULATES THE GLASS FIBERS. THE
COMPOSITE MATERIAL SHALL BE FABRICATED TO INCLUDE A NOMINAL 152mm WIDE BARRIER OVERLAP TAB EXTENDING BEYOND
160Ø 1:100 BATH/SHOWER -50 mm
THE QUILTED FIBER GLASS TO FACILITATE A LEAK-TIGHT SEAL AROUND FIELD JOINTS. KITCHEN SINK (KS)/PANTRY -50 mm
THE DECOUPLING LAYER SHALL BE TYPE KFA BY 'KINETICS NOISE CONTROL INC.'OR EQUAL APPROVED. 200Ø 1:150 W.C. (WATER CLOSET) -110 mm
DRAIN PIPE 4
CONCRETE PROTECTION OF
3 PIPELINES UNDER BUILDINGS
N.T.S
N.T.S SLOPE SCHEDULE
(FOR ROAD CROSSING LESS THAN 1000mm)
700
60cm
30 CM ABOVE
SHOP DRAWING
20cm
GRANOLITHIC CEMENT
CONCRETE BENCHING.
1:6
20cm 60cm 20cm FALL
700
300 x 300 FRAME AND COVER
20
100mm Ø UPVC OUTLET Tel: +971 50 308 6171
MAIN FILL COMPACTED GRATING P. O. Box: 236341,
IN LAYERS OF NOT MORE Dubai, UAE.
CONC./CHB THAN 300MM
WALL 50ØVENT
20Ø AIR
CHAMBER 50ØSP STRUCTURAL CONSULTANT:
15ØCWL SELECTED FILL FREE FROM
DESIGN ENGINEERING CONSULTING
60
BUILDERS RUBBISH HAND CONCRETE GRADE 40
COMPACTED
FIN. WALL
Tel: +971 55 312 4812
20
CONCRETE GRADE 15
ANGLE
VALVE www.eng-str.com
TRENCH BOTTOM HAND TRIMMED
INLET SPUD
CONC./CHB
WALL
8
BEDDING OF PIPE LINES UNDER
N.T.SROADS PATHWAYS ETC 9
TYPICAL DETAIL OF GULLY TRAP 10
FIXING DETAIL OF MANHOLE INLET & OUTLETS PROJECT NAME & LOCATION:
N.T.S N.T.S
(MINIMUM DEPTH UNDER ROADS 1000mm)
50Ø VENT
URINAL
DRAWING BY Maheboob JOB NUMBER -
MIRROR BLOCK WORK
FLOOR DRAIN GRATING TILES
50Ø SAN BEDDING 15Ø CWS & HWS DROP FROM CHECKED BY Eng.Muthu SCALE NTS @ A1
TEE HIGH LEVEL CONCEALED
WATER PROOF MIRROR SHELF
IN WALL SUPPLY TO Eng.Waseem
APPROVED BY DATE 23/12/2022
WASH BASIN
SCREED 15Ø CWS DROP FROM
15Ø CWS & HWS DROP FROM HIGH LEVEL CONCEALED
WALL 50Ø SP HIGH LEVEL CONCEALED IN WALL SUPPLY TO WC DRAWING NAME:
FLANGE 300x300 UPVC IN WALL SUPPLY TO CISTERN & SPRAY
15Ø CWL SOAP DISH
PLATE WELDED TO 110Ø UPVC
FIN. WALL
PIPE
CP RIGID PIPES
BIDET
DRAINAGE GENERAL NOTES,
50Ø SP
FFL
COLLECTOR
UPVC ADAPTER
CP RIGID PIPES
CP RIGID PIPE WC SUPPORT
LEGENDS & DETAILS
CP ANGLE VALVES 50ØVENT
OPEN TYPE SEAT COVER
BOTTLE TRAP
DWG No. Rev No.
CP ANGLE VALVE
200mm MAX.
CLEVIS HANGER
THE BEAM [L] BEAM SIZE SIZE
KG. M. MM. MM. 2mm. THICK ZINC PIPE
1.00 45x30x6 8 COATED STEEL SHEET
INSULATION VAPOR BARRIER
600mm CLEAR OPENING UP TO 150 AT LEAST 30CM. LONG.
1.50 60x40x6 8 INSULATION
COVER BASE
1.00 60x40x6 10
150 TO 300 CLEVIS HANGER CLEVIS HANGER
A-SECTION 1.50 80x60x6 10
DETAILS OF THE PIPE SUPPORTS SINGLE HORIZONTAL RUNS SINGLE HORIZONTAL RUNS
300 TO 500
1.00 80x60x6 12 2 N.T.S
NO VAPOR BARRIER INSULATION WITH VAPOR BARRIER INSULATION
MANHOLE COVER 2/2 1.50 80x60x8 12
1 N.T.S 2000 1.00 150x100x12 16
CONCRETE
P-TRAP
SHOP DRAWING
INDICATIVE MANHOLE AND PLANTING BEDS
5
FT-1 FLOOR DRAIN (WITH ADJUSTABLE STRAINER)
TYPICAL FLOOR DRAINAGE CHANNEL N.T.S
3 4 N.T.S
N.T.S
SLAB Tel: +971 50 308 6171
45° BENDS P. O. Box: 236341,
Dubai, UAE.
80mm MIN
FLOOR TRAP
2000 mm
FLOOR SLAB
DRAWING BY Maheboob JOB NUMBER -
FLASHING SLEEVE
CHECKED BY Eng.Muthu SCALE NTS @ A1
CONDENSATE DRAIN TO FLOOR DRAIN GREASE TRAP TYPE - B ROOF VENT TERMINATION TYPICAL DETAIL
6 7 8
N.T.S TYPICAL CONNECTION DETAIL N.T.S TYPICAL DETAIL N.T.S
KEY PLAN
20cm
60cm
20cm
60cm
20cm
20cm
20cm 60cm 20cm
15cm CONCRETE
BASE
7cm 20cm 40cm 40cm 20cm 7cm
15cm CONCRETE 10cm CONCRETE
1.24m
BASE BLINDING
7cm 20cm 30cm 30cm 20cm 7cm
10cm CONCRETE
1.14m
BLINDING
60X60CM I.C. DETAILS UP TO 90CM DEPTH 80x80cm I.C. DETAILS UP TO 120cm DEPTH
1 2
N.T.S N.T.S 1000X1000CM I.C. DETAILS UP TO 150CM DEPTH
3 N.T.S
SHOP DRAWING
Tel: +971 50 308 6171
P. O. Box: 236341,
Dubai, UAE.
STRUCTURAL CONSULTANT:
1200X1200CM I.C. DETAILS UP TO 200CM DEPTH Ø1300 CM I.C. DETAILS ABOVE 200CM DEPTH DESIGN ENGINEERING CONSULTING
4 5 N.T.S
N.T.S
Tel: +971 55 312 4812
www.eng-str.com
MEP CONSULTANT:
DRAWING NAME:
6" UPVC Class 16 or eqrivatent should be used to connect
manhole to manholes DRAINAGE GENERAL DETAILS-3