You are on page 1of 2

FIG.

80 BJ
1
9. Display systempressure / frame inclinometer 10. Rod indicator LED's 11. Power - comunication indicator

12. UPS off

13. Start / Stop


16. Driveclamp close / open
15. Drivebox up / down
17. PTO pressure / flow control

14. Mode selection 18. Flow / speed control

19. Serial drive 23. Pressure control


24. Max pressure indicator LED

20. Drive up / down


22. PTO A / B
21. Casingclamp close / open 25. Position indicator LED's

1:3,33 31. 24V


26. GME-500 connection
27. Optional communications 30. Umbilical communication to Manta
28. Analog / digital
29. GeoBUS

2
1. Main power switch

8. 24 V OUT check

2. 400VAC - 50Hz / 440VAC - 60Hz in 7. 24 V OUT - 2x


32A fused
minimum 25kVA generator 3. Power IN check

4. Phase IN check

5. Power OUT 6. Power OUT check

# Description Article no.


1 Manta control box deck 0080502021A
2 Manta power box deck 0080502020

THIS DRAWING IS PROPERTY OF GEOMIL EQUIPMENT BV ( GME ). ANY DISCLOSURE, TRANSFER, USE AND/OR REPRODUCTION OF THIS DRAWING, OR THE DESIGN HEREIN, WITHOUT EXPRESS WRITTEN CONSENT FROM GME IS PROHIBITED. ALL RIGHTS RESERVED.
FIG. 80 BJ

1. Main power switch 5. Power output


Thermal-magnetic circuit-breakers output power 400 / 440 VAC 50-60Hz out
enable (black) 400 / 440 VAC 50-60Hz activated on Manta system 6. Power out check
disable (red) 400 / 440 VAC 50-60Hz deactated on Manta system
light off no / incorrect power output
2. Power input light on 400 / 440 VAC 50-60Hz out
supply voltage 400 / 440 VAC 50-60Hz
7. Power output to control box deck
supply fuse 32A
supply source minimum 25kVA output power 24V ~ max 5A

3. Power in check 8. Power out check


light off no / incorrect power supply light off no / incorrect power output
light on 400 / 440 VAC 50-60Hz detected light on 24 V out

4. Phase in check
light off no / incorrect phase
light on Correct phase sequence

9. Display Reset of frame inlination (Set zero degree)


pressure display of system pressure in bar Motor off
inclination display of x - y frame inclination in degree Simultaneously hold for 3 seconds Drivebox up
Casing clamp close
10a. Top sensor Drive clamp close
LED on casing detected at topsensor
LED off no casing detected at topsensor

10b. Bottom sensor


LED on CPT rod detected at bottom sensor
LED on Casingclamp detected in close position
LED off no CPT rod detected at bottom sensor

11. Power - communication indicator


LED off no connection between deckbox - Manta
LED blinking no 400 / 440 VAC 50-60Hz detected on Manta
LED on active connection between deckbox - Manta

12. UPS
push button suspended black
button unabled UPS on
button enabled Switch off UPS in 2 seconds

13. Start / Stop


push button latching transparent with light
button unabled switch motor off
button enabled switch motor on
light off unabled motor - motor not running
light blinking enabled motor - motor not running
light on enabled motor - motor running OK

14. Mode selection 17. PTO P / Q setting


selection switch 3 positions 60° maintained selection switch 3 positions 60° maintained
CPT enable CPT - fine adjustmend of Flow / Speed control P enable PTO constant pressure control
Manual enable manual - full adjustment of Flow / Speed control Q enable PTO constant flow control
PLT (option) enable Plateload test (option)
22. PTO A / B se tting
15. Drivebox
selection switch 3 positions 60° maintained
selection switch 3 positions 60° maintained
A enable PTO port A
neutral stop drivebox action B enable PTO port B
drivebox up move drivebox up - Flow / Speed control
drivebox down move drivebox down - Flow / Speed control

16. Driveclamp
selection switch 3 positions spring returned
driveclamp close close driveclamp - pressure control
driveclamp open open driveclamp - pressure control

19. Serial drive


push button latching transparent with light
button unabled activate serial drive
button enabled activate parallel drive
light off parallel drive enabled
light on serial drive enabled

20. Drive
selection switch 3 positions 60° maintained
neutral stop drive action
drive up drive up - Flow / Speed control
drive down drive down - Flow / Speed control

21. Casingclamp Function indicator LED


selection switch 3 positions spring returned LED on most recent enabled function
LED off unknown
casingclamp close close casingclamp - pressure control
casingclamp open open casingclamp - pressure control

THIS DRAWING IS PROPERTY OF GEOMIL EQUIPMENT BV ( GME ). ANY DISCLOSURE, TRANSFER, USE AND/OR REPRODUCTION OF THIS DRAWING, OR THE DESIGN HEREIN, WITHOUT EXPRESS WRITTEN CONSENT FROM GME IS PROHIBITED. ALL RIGHTS RESERVED.