You are on page 1of 4

Discover combined multi-

modality breast viewing


Philips IntelliSpace Breast solution

“Multiple workstations have always been a major efficiency


blocker when analyzing multiple breast imaging modalities.” Key advantages

We often heard statements like this from imaging facilities. • Save space and time:
Because these observations matched Philips’ research initiatives, All studies available at a single workspot

we developed the IntelliSpace Breast solution. It’s a highly efficient • Quality of care:
solution that allows you to review multi-modality breast images Display complete patient history and
report data using BI-RADS ® standard
at a single workstation using a synchronized reporting standard.
Medical personnel value the seamless viewing processes. • Customize your solution:
Choose the most suitable
“Now I save time and space and improve the quality of care – configuration for you
with the IntelliSpace Breast solution from Philips.”

The print quality of this copy is not an accurate representation of the original.
Keep your seat and keep track
The IntelliSpace Breast solution allows you to stay seated while obtaining a complete overview
of images and reports from three different modalities. Combine the IntelliSpace Breast solution
with Philips digital mammography, ultrasound and MRI imaging systems and network solutions
like PACS and RIS. This way, Philips provides holistic service throughout every phase of the
women’s healthcare cycle.

US

Save space and time


MAMMO MRI
To date, radiologists have had to
collect mammography, ultrasound and
MRI images plus reports from multiple
systems in order to interpret their
findings. Now, with the vendor-neutral
“The IntelliSpace Breast solution allows me IntelliSpace Breast solution you can
to seamlessly view and analyze mammography, easily see the relationship between
“I’ve certainly got better things to do than ultrasound and MRI from different vendors at modalities in more detail, enhancing
walking from workstation to workstation.” one single workspot.” confidence in your interpretation.

One patient – one session


Patient A Evaluating the breast health of one
US 2010Patient A
Patient A
particular patient is so much easier
MAMMO 2008
MAMMO 2010

Patient A
Patient A Patient A MAMMO 2010 when you have immediate access to
MAMMO 2008 US 2010
all the data. With the IntelliSpace
Breast solution, the patient’s past
medical history is right at your finger-
“If I am dealing with one patient I don’t want “The IntelliSpace Breast solution automatically tips. Screening, diagnostic follow-up,
to have to look at different workspots for the opens all prior images and reports of all three staging examinations and treatment
complete history and the current exams.” modalities from one patient.” monitoring are all available to you.

Sometimes standard is best


The IntelliSpace Breast solution incorporates
Report Y BI-RADS® BI-RADS ® as a reporting standard. All the
REPORT
BI-RADS ® tools are available directly, easily
Report x Report Z
allowing you to create a complete BI-RADS ®
report. This way, your clinical counterparts
can find the key information quickly. The
BI-RADS ® entry is fully integrated into image
“Now I can consistently fill in my reports in viewing and analysis. Facilities appreciate the
“If a reporting standard exists why do a standardized review structure according simple result: Improved reporting improves
I have to deal with mixed reports?” to BI-RADS®.” the quality of care.

The print quality of this copy is not an accurate representation of the original.
“The integration of all
images and information
Customize your package
Whether you focus on mammography screening, on combined to assess the history of
mammography and ultrasound or on multi-modality viewing the patient is making our
with MRI, Philips’ IntelliSpace Breast solution is available in the
lives much easier. All the
software and hardware mix you prefer.
duplicate work we did with
Innovations in mammography viewing all the separate systems
The IntelliSpace Breast solution features unique, automatic breast
is now a thing of the past.
tissue alignment which optimizes the symmetry between left and
right breast tissue. You’ll also appreciate the user-preferred hanging Integration saves us a lot
protocols and the one-touch mammography keypad. of time. And it connects to
better care for the patient
Benefits in mammography and ultrasound viewing
To further assess your diagnosis you can add ultrasound images to by more accurately relating
your mammography exposures. View ultrasound images in 3D at findings from different
the color application monitor of the IntelliSpace Breast solution. In
modalities.”
this context you can also perform a 3D reconstruction of volume.
Furthermore, you can assess ultrasound in a volumetric 3D display. Dr. Gillian Newstead,
University of Chicago Hospital
Advances in multi-modality viewing
You’ll also benefit from numerous ultrasound and MRI viewing
features. Ultrasound and MRI studies are automatically displayed
in specific hanging protocols including multiplanar reconstructions,
maximum intensity projections and subtraction images over the
dynamic series. Another useful function is the digital breast diagram
which allows you to consistently indicate the location of lesions
across the various modalities. For every lesion you’ll find separate
BI-RADS ® information and designated key images in the breast
diagram. With MRI, the correlation between image position and
breast diagram is generated automatically.

The holistic path


With its care cycle approach to women’s health, Philips provides
systems for each stage of breast health care. We are your
consultative partner, offering you customized service contracts
and incorporating sustainability in our solutions.

The print quality of this copy is not an accurate representation of the original.
IntelliSpace Breast solution
Navigation monitor Mammography monitors
Color monitor for Two designated 5MP
patient administration mammography monitors

Application monitor
Color monitor with Multimodality Mammography keypad
Breast Application including Dedicated mammography workflow
priors and BI-RADS ® reporting keypad with one touch operation

Hardware

Operating system W2008 server 32 bits standard edition


Hard drives 4 x 1 TB Near-Line SAS (7.200 rpm) hard drive in RAID 5
Server
Processor 1 x X3430 (2.4 GHz, 8 MB L3, Turbo)
System  Memory configuration 4 GB 1333MHz UDIMM DDR3 memory (2 x 2 GB)

Operating system Windows 7 ultimate x64 to XP Pro x64


Hard drive # 1 300GB (15K rpm) SAS: No raid configuration
Client
Processor 1x W3530 (8 MB cache, 2.80 GHz, 4.80 GT/s QPI)
Memory configuration 6 GB 1333 MHz UDIMM DDR3 memory (3x 2 GB)

1 Navigation monitor 22" (resolution 1680 x 1050)


Monitors 1 Color application monitor 30" (resolution 2560 x 1600)
2 Mammography monitors 21.3" (resolution 2048 x 2560), 5MP monitors

Mammography keypad Philips mammography keypad, backlight buttons


Accessories
Media writer CD-DVD robot (optional) incl. DICOM viewer

Software
Mammography and ultrasound review (Multi-modality Breast Applications US)
Software package A 
MG/US visualization incl. priors, structured reporting according to BI-RADS ®
Mammography, ultrasound and MRI review (Multi-modality Breast Applications US & MRI)
Software package B
MG/US/MR visualization incl. priors, structured reporting according to BI-RADS ®

Upgradability
Upgrade A MammoDiagnost VU IntelliSpace Breast solution with software package A
Upgrade B MammoDiagnost VU IntelliSpace Breast solution with software package B

Please visit www.philips.com/mammography

© 2010 Koninklijke Philips Electronics N.V. Philips Healthcare is part of Royal Philips Electronics
All rights are reserved.
www.philips.com/healthcare
healthcare@philips.com
Philips Healthcare reserves the right to make changes in specifications and/
or to discontinue any product at any time without notice or obligation
and will not be liable for any consequences resulting from the use of this Printed in The Netherlands
publication. 4522 962 66241 * NOV 2010

The print quality of this copy is not an accurate representation of the original.

You might also like