IntelliSpace Portal

Pre-installation guide

Diagnose and collaborate anytime, Integrates to any PACS


anywhere IntelliSpace Portal features proven open
Philips IntelliSpace Portal offers flexibility interfaces for integration with Philips
to diagnose and collaborate virtually PACS and PACS from other vendors, and
anywhere. This thin-client application is updated continually through the server,
server solution allows simplified access providing desirable simplicity and scalability
for multimodality clinical review and analysis while reducing the need to acquire multiple
to support patient care. Industry-leading workstations by modality and specialty
rich clinical applications across specialties over the years.
are designed to help you realize the full
potential of your scanners to quickly The Philips IntelliSpace Portal provides
quantify and diagnose. clinicians access to advanced multimodality
viewing and clinical applications anywhere
Your access, your way the network reaches. Based on the Philips
IntelliSpace Portal provides proven Extended Brilliance Workspace, IntelliSpace
access to clinical functionality, workflow, Portal delivers multimodality images and
and collaboration tools at any location applications to clinicians inside and outside
connected to the enterprise through a the facility through proven thin-client
single applications server integrated with technology.
PACS. It’s an integrated clinical solution
that’s multispecialty, multimodality, and The IntelliSpace Portal Server handles the
multivendor. It gives radiologists the complex processing of multimodality data
tools to access, create, and disseminate and streams images to the client over the
actionable information throughout the facility network or remotely through
enterprise through a secure, real-time, a secure Virtual Private Network (VPN),
and collaborative platform, including Web reducing the processing power necessary
Collaborator medical networking tools. on the client side.
General networking information IntelliSpace Portal Client hardware IntelliSpace Portal Server
Most installations include a CT, MR, or NM requirements information*2
scanner and a workstation in addition to • Video card that supports Windows Dell™ T610 Server:
the IntelliSpace Portal Client-Server system, DirectX® 9.0c or higher (for Portal V1.0 only) • CPU: Two Intel® Six-Core @ 3.46 GHz
although it is possible to pair the scanners • Minimum screen size of 1280 x 10241 • RAM: 32 GB
with the Portal alone. The connection (recommended) or 1024 x 786 • Operating system: Windows Server 2008
between these systems is a simple TCP/IP • Minimum processor speed: 1.0 GHz 64-bit R2
network. (2.0 GHz recommended) • DVD-ROM drive
• Minimum memory: 512 MB of RAM • Network cards: 1 GB/s network adaptor
There are two modes of operation (1 GB of RAM recommended) • Rack mounting kit
for the IntelliSpace Portal • Network adapter: 1 GB/s recommended
• Internal operation. The clients are PCs • 500 MB free disk space on drive C:\ Note:
located inside the healthcare facility, on the • Three-button mouse with scroll wheel • The client’s antivirus program must allow
same network as the Portal. highly recommended the Portal to communicate through the
• Remote access. Client PCs are located • Video card should be dual monitor display firewall to function properly.
outside the clinical or hospital building. in order to utilize this feature
To allow remote access, the hospital or Testing clients’ minimum
clinic must have or set up a virtual private IntelliSpace Portal Client software requirements
network (VPN) secure connection to the requirements Each Portal system is supplied with a
Portal network. • Windows Installer V3.0 or later CD-ROM containing an executable file that
• Either Windows XP ® (SP2), Windows will test the client’s hardware and software
The IntelliSpace Portal Server requires an Vista®, or Windows 7® configurations for the minimum requirements.
existing network. Scanners from Philips • .Net ® framework 3.5 or higher
support network speeds of up to 1 GB/s. • Windows account administrative access Load the CD-ROM in the client’s CD-ROM
Ideal networks will provide 1 GB/s connections (for initial installation only; not necessary drive, and in the window that opens click
among scanners or Portal Server because for single user install) on “Perform Test.”
Portal is a bandwidth-dependent application.
The greater the network speed, the better Note:
the performance. Portal will perform • The client software will not be installed
optimally at 1 GB/s. if the minimum requirements are not met.
• .Net components will be installed or
Note: updated by the Client Software Installer.
• If you cannot ping the server across The included software tests clients’ PCs
the internal network, you will not for the minimum requirements.
be able to connect to the Portal.

1
Many laptops will support this larger matrix but only
if connected to an external monitor. The monitor should
be connected and the display matrix set to 1280 x 1024
before running the auto test.

Specifications subject to change without notice.


2

2
Responsibility:
Philips – software, LAN, NM, MR,
configuration, hardware or CT Scanner

Portal Server
PACS

EBW

Images from scanner

Images from server

Net

client client client

Responsibility:
Facility IT support – network, client software

client client

Before installation Installation considerations Connecting with authenticated


A Philips Service Engineer and Project • It is strongly recommended to locate the Windows users
Manager will meet with your facility’s Portal Server in an IT (server) room or • Authenticated Windows users may connect
installation coordinator to visit the site another clean and secure environment. to Portal without being asked for a user
prior to installation and verify site readiness. • To avoid dust problems, place the server name or password if the Portal server
Individual site layout and environmental on an elevated surface. Placing the server is part of the user’s domain and is trusted
specifications are included in the final directly on the floor causes DVD, RAM, by the Portal server domain.
installation drawings for each site. fans, and other components to collect dust • Portal permissions with Windows users
and dirt, causing failures. are set by Portal administrator.
Installing the Portal Client • The server requires a UPS with • For further details refer to
via Group Policy specifications of 1.5 kVA at 40% load IntelliSpace Portal Instructions for Use
• Portal offers the option to system for 10 to 15 minutes. (P/N 453567464511_C) available for
administrators to perform remote updates • Connect the servers to the facility network download from InCenter.
of all the Portal Clients installed on a using a network switch.
domain. For details refer to the Portal • Philips and your Facility IT support staff
Management Application Section have discrete areas of responsibility.
1.8 (available on the InCenter P/N
453567464541_B).

Note:
• Manual installations (either through web
or Client CD) may only be removed or
upgraded manually.

3
Roles and Responsibilities
During IntelliSpace Portal installation

Authority Responsibility
Philips Service Engineer • Server system installation (KB, mouse, monitor, LAN network)
• LAN configuration of the server
Facility IT Engineer • Client software installation
Note: The Service Engineer will train Facility IT on the Client software installation
• Client network and connection to server
Note: The Service Engineer will train Facility IT on the Server software installation

During IntelliSpace Portal maintenance


Authority Responsibility
Philips Service Engineer • Maintain server operating software (Windows 2008 server 64-bit edition)
• Maintain and upgrade server software
• LAN configuration of the server
• Maintain server hardware (per agreement with Dell)
Facility IT Engineer • Client software upgrade
• Maintain administrative settings: users, passwords, client permissions, client network,
and connection to server

Philips Service Engineers will install the Server installation takes approximately
Portal Server. 3 Coordination and teamwork two hours (excluding options and travel
with your Facility IT staff is required for time). Networking normally takes up to
connecting the server to the network. two additional hours. Network cabling
is unique to each site and must be planned
Your Facility IT staff is responsible for and coordinated separately prior to the
installing the Portal Client software pack, system delivery.
with assistance from Philips for the first
client. Facility IT staff will be responsible for Refer to the handbooks supplied with
configuring and installing subsequent clients. the equipment for full specifications
and operating conditions.
Any user with administrator rights for the
PC must be present to adjust client software
settings. Client installation will take from five
to ten minutes for each client PC.

3
Only Philips-certified Service Engineers, Co-Op
customers, and authorized distributors may install
this equipment. Installation and warranty targets
can only be met if certified engineers are used.

4
Frequently Asked Questions

Q: Can the client be installed on Windows


Vista systems?
A: IntelliSpace Portal will work properly
with Windows Vista and Windows 7
as long as other client prerequisites
are met.

Q: What is the power requirement


for the server?
A: It has redundant power supplies,
requiring two 110V inputs. AC cord
rating is 15 Amps @ 120VAC or
20 Amps @ 240VAC.
Q: What ports need to be configured Q: What is the meaning of the compression
Q: Is the Portal rack-mountable? to use the Portal remotely in the index (e.g. 80%)?
A: Yes, the Portal is rack-mountable and facility’s firewall? A: The compression index measures image
a conversion kit is included with the A: IntelliSpace Portal Version 4.x Server quality by comparison with the original.
system to enable you to mount the requires the following “server incoming” Since 100% means “lossless,” 80% means
system in either square- or round-hole hospital or clinic firewall exclusions: “near lossless.”
rack systems. • If TCP tunneling won’t be used,
then ports are: Q: What is the relation between image
Q: Can I use another hardware – 80/443 quality and the compression index?
manufacturer? – 755 A: 100% means 2:1 to 3:1, or lossless
A: No, in order to comply with regulatory – 758 compression
requirements and to assure optimum – 780 • 80% means 7:1 to 10:1
performance, IntelliSpace Portal is – 9100-9200 TCP • 40% means 12:1 to 20:1
delivered only as fully manufactured • If TCP tunneling will be used, For example, at 3:1 compression, typical
with both software and hardware then ports are: 512 KB CT images become 170 KB.
provided by Philips. – 80/443 At 20:1 the same image becomes 25 KB.
– 1080
Q: How does the remote Portal Client – 9150 Q: Why does the ratio change for a given
access the Portal Server? compression index?
A: The Portal requires a VPN (Virtual Q: Why do we use compression? A: The compression ratio depends on
Private Network) connection to allow A: We use compression to improve the content of the image. A “clean
the client to tunnel to the Portal. The system performance. image” with lots of air background will
VPN SW and HW are not supplied by compress much better (and therefore
Philips. The VPN secure connection is Q: How do we compress the images? have a larger ratio) than a low dose,
required because of the multiple ports A: We use JPEG for lossy compression and noisy image with little air in the
used by the Portal to respond to client JPEG-LS for lossless compression. background.
requests. Using the VPN allows for all
ports to be securely accessible.

5
Q: Is the effect of compression on Q: Why can’t I burn a CD/DVD?
performance always the same? A: You may not have sufficient user rights
A: The slower the network, the more granted within your IT network
beneficial compression will be to
performance. Q: How do I log on to a Portal Server using
a NAT Router?
A: The Portal supports a NAT IP through
a TCP tunnel. Check “Enable TCP
tunneling” in the Advance dialogue.
Users may change the compression
index as desired by selecting Q: Interacting with the images on screen
the highlighted icon in the picture seems to be slow even when the
at the right. connection between the client and the
server meets the recommended speed.
A: If the client computer uses an on-board
Intel ® Graphics Media accelerator
(GMA) graphics card, it is strongly
recommended to update the video
driver, which may significantly increase
the interaction frame rate.
Q: How do I know the Portal Client
and Server status? Q: What hardware is supported by Portal?
A: The “Portal Status” can be viewed A: Currently the Portal Server is
in the system tray after starting the only provided as a hardware and
program and logging on. Right-click software bundle on fully verified and
the Portal icon and select Status validated hardware configurations.
(see picture at the right showing the The production hardware currently
status on a client). supported is Dell T610.

Our recommendation is to have Q: Can we use different hardware and just


at least 500 MB memory free on the load the software?
client computer for the Portal. A: No. It is not possible to install the Portal
Server software on user-provided
hardware configurations. The Portal is
manufactured under strict regulatory
and quality principles and governed as
a medical device. The development and
configurations of the Portal are strictly
controlled.

6
Q: Should the IntelliSpace Portal be placed
in the facility’s domain?
A: It is recommended adding the Portal
to the facility domain.

Q: Can the server be set to use Dynamic


Host Configuration Protocols (DHCP)?
A: The Portal cannot operate in this
environment. It requires a static IP.

Q: Why does it require a static IP?


A: It must be static because the devices
require a static IP address to direct the
clinical image data. The server supports
name recognition.

Q: Who assigns IP addresses to the devices?


A: Your facility’s IT staff will need to
provide Philips with a set of IP addresses
in the network structure to use for the
Portal, Extended Brilliance Workspace,
and scanners. Q: If there is an update to the client Philips permits you to install only
software, will it be automatically available? security updates, which have the
Q: When are the IP addresses assigned? A: Not at this time. Users are sent “Recommended Customer Action”
A: The IP address of the Portal will be notification if there is an update to the as “Install Recommended solution.”
configured during the installation of client software, but the update must be For each of these approved security
the client software on client PCs. If an manually installed. Future plans call for updates, the vulnerability evaluation
incorrect IP address is entered during the ability to automatically update clients. report mentions the Knowledge
client installation or if the IP address of Base (KB) Article related to each
the Portal changes, it is possible to enter Q: Are Windows automatic updates active security update. You can download
a new or corrected IP address during on the Portal Server? the respective update referenced
client login. The Portal Client can access A: No. Philips tests all updates to assure by the unique Microsoft KB number
server by DNS or WINS name. the smooth operation of the server. from the Microsoft TechNet website
For a list of approved and validated or from an internal server or repository.
Q: Can the client software be automatically Microsoft security updates, refer to
downloaded to a first time user? the vulnerability evaluation report Q: Can the client be installed on an
A: Yes. Simply type in the IP addresses of available at: http://www.healthcare. Apple ® computer?
your Portal and add/install and this will philips.com/main/support/ A: Yes, but only on Apple Macintosh®
take you to the installer for your Portal. productsecurity/vulnerability_ systems using Intel CPUs and either
tables.wpd. running Windows XP under Mac OS
as a virtual machine, using Parallels
Desktop ®, or using Boot Camp ®
(a dual boot Mac or Windows XP
solution from Apple).

7
Philips Healthcare is part of
Royal Philips Electronics

How to reach us
www.philips.com/healthcare
healthcare@philips.com

Asia
+49 7031 463 2254

Europe, Middle East, Africa


+49 7031 463 2254

Latin America
+55 11 2125 0744

North America
+1 425 487 7000
800 285 5585 (toll free, US only)

Windows, Windows XP, Windows Vista, DirectX, and .Net are registered trademarks
of Microsoft Corporation in the United States and other countries.
Dell is a trademark of Dell Computer Corporation.
Intel is a trademark of Intel Corporation in the U.S. and/or other countries.
Parallels Desktop is a registered trademark of Parallels Holdings Ltd.

Please visit www.philips.com/intellispace

© 2011 Koninklijke Philips Electronics N.V.


All rights are reserved.

Philips Healthcare reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or
obligation and will not be liable for any consequences resulting from the use of this publication.

Printed in The Netherlands.


4522 962 70271 * MAR 2011