NOTE:
Refer to service manual Form U3633 (14U12A/U52A) for the other instructions.
Use needle Cat. 2045 size #14 for 14U64A and Cat. 2053 size #14 for 14U14B.
1. TO SET NEEDLE BAR AT CORRECT
HEIGHT Needle Bar Connecting
Fig. 1 I
With size No. 14 needle set in needle bar, and using
service gage set hight of needle bar by moving
needle bar up or down as required until correct
height is obtained, see Fig. 2.
Fig. 2
- --
.
2. LOOPERS (LEFT AND RIGHT)
Loosen left hand looper screw. Usung service gage, set the ,
left hand looper in position as shown in Fig. 3. Holder Screw
Firmly tighten left hand looper screw.
Fig. 3
2) To Time the Left Hand Looper
2nd U H Looper
Cam Set Screw
U H Looper Shaft Lever
4
and 6)
5.5mm
L/H Looper
Extreme Left
Use service gage when setting needle rise. The '"-?d
- *A
Position Fig.6
service gage is calibrated at 0.6mm intervals. Re-
move needle bar bushing (upper) cap and insert
service gage into the needle bar bushing (upper),
turn pulley toward you until the needle bar rises
six calibration (on the service gage) from its lowest
position. This position is the specified 3.6mm
needle rise. (Fig. 8)
Needle Bar
Bushing (upper)
r*
P
Fig. 8
3..
h
I r_ *. 4
Loosen left hand looper holder screw (Fig. 3) and
move looper holder forward or backward, as
required, so there is a 0-0.05mm clearance be-
i tween looper point and reverse side of needle
(Looper point at center of needle). (Fig. 9) Firmly
tighten left hand looper holder screw.
f
Loosen right hand looper shaft lever set screw
taking care not to move the right hand looper cam,
and set the looper shaft lever so that the center of
eye of the looper is located 3.lmm from the side
of needle and firmly tighten the set screw. ( F ~ ~ s .
4 and 10) I.2mm
R/H Looper
Turn the pulley toward you to bring the left and Highest Position
Fig. 10
right hand loopers to the position shown in Fig.
11 and adjust the right hand looper cam to provide
clearance shown in Fig. 11. Then tighten the nght
hand looper cam set screw.
U H Looper 0 - O.lmm
ig. 12
* 3. ADJUSTMENT OF NEEDLE GUARD
I Needle Guard Set Screw I
Loosen the needle guard set screw, adjust the clearance
between the needle and front and back needle guard as
shown in Fig. 13 and retighten needle guard set screw.
Fig. 13
Overedge seam width of this machine is set to 3.5mm for normal sewing conditions, however it can be
increased up to 5mm for overedging heavy weight fabrics as instructed below.
Before making the adjustment, be sure that the power line plug is disconnected from the wall receptacle.
Open the looper cover.
Turn the machine pulley toward you, lower the movable knife as far as it will go and set it in the non-
operating position as shown in figure below.
Remove the cylinder cover.
Push the movable knife holder to the As shown above, the movable knife
rn
Left end
of stationary
knife holder
ECTRIC CIRCUIT
RECEPTACLE
- := C
L
Phl
MOTOR