PUMPSENSE CS 7 1/1

CASE STUDIES – CS 7

Case studies in conditioning monitoring of pumps:

Pump type & Observations Symptoms & Likely cause &


details information from solution
spectra
Single-stage end Bearings failing Pump flow very low- Orifice found to be only
suction pumps every 6 weeks. Rotor operating near shutoff. 25mm. Replaced with
seen to shuttle Continual recirculation correct 75mm size and
(Pump 1500 axially. Flow tested. system has orifice problem solved.
lps@91m) marked 50mm
diameter.

Pump type & Observations Symptoms & Likely cause &


details information from solution
spectra
Two-stage pumps, High vibration, Spectra at full output On dismantling,
constant speed increasing with showed high non- casing wear ring
3000rpm output. synchronous (PTFE) inserts were
6.5mm/s rms at missing. On
1.361x.1x was only replacement
2mm/s vibration was only
1.8mm/s.