Technical Data Sheet: Water Systems

Reverse-Osmosis
Systems
for marine and land based
application

Hamworthy Serck Como GmbH design and manufacture Advantages:


reverse-osmosis (RO) units which are used for producing  Small and effective pre-filtration unit with automatic back
fresh water from sea water and well water. These plants are flushing filter and cartridges as polisher.

for marine (ship, offshore) and land based installation for  Easy retrofit because of modular installation, which is
producing process, technical or potable water. Several flexible to adapt on site.

applications for treatment of industrial water are possible  Valves are available with electric or pneumatic actuators.
on request.  All components are manufactured of corrosion resistant
material.

 Easy operation because of touch panel.


Description of plant and process
The sea water (feed) is pre-treated in our filtration unit,  Pre-commissioning has been done before delivery.

therefore nearly all particles smaller than 5µm will be  All units are pressure tested before delivery to the
removed. The high pressure pump will induce the needed customer.

operation pressure. The sea water flows through the


pressure vessels. Inside the vessels are membrane elements. Characteristics:
These elements let the water molecules pass through. Ions,  The permeate capacity of our standard RO-units is in the
bacteria, virus, etc. will be retained and discharged with the range of 50 -1000 t/d.
concentrate flow. Only small monovalent ions (Na+, Cl-) will  Residual salt content of permeate < 500 µS/cm for potable
pass, too, in a low percentage value. The number of water, or < 5 µS/cm for technical water (min. 2 stages).
membrane elements, operation pressure and rejection is  Full automatic operation and semi-automatic operation
dependant from requested water quality and quality of feed available.
water. Back pressure at concentrate and permeate piping
should be maximum 2 bar, feed pressure of 0.2 - 0.5 bar will
Options:
 Energy recovery unit to reduce power consumption of the
be enough for operation.

high pressure pump (capacity more than 250m³/d).

RO-Units are installed either very compact on a single base  Preheating unit to get a constant seawater temperature at
the inlet (e.g. heat exchanger, mixing with warm water)
frame or each module (pre-filtration, pumps, membrane
for constant permeate flow in cold water areas.
section) on an extra one, depending on request. They are
 Second stage for technical water (complete or branch
equipped with all necessary measuring equipment and
permeate flow).
valves for full automatic operation. The tank for flushing is
 Multi-media filter for pre-treatment available.
always included; the chemical cleaning system can be
delivered separately.
Reverse-Osmosis Systems Water Systems

Flow diagram for reverse-osmosis unit


Single stage

Permeate

M M

SEAWATER

Seawater High pressure


pump pump

Pre-filtration Membrane modules Concentrate


unit first stage

Hamworthy Serck Como GmbH


Pankower Str. 16 - 18
D-21502 Geesthacht, Germany
tel: ++49 4152-805-0 fax: ++49 4152-805-105
e-mail: geesthacht@hamworthy.com The manufacturers reserve the right to alter the
specification and data to incorporate improvements in design.
ref: HWS0069 0909

website: www.hamworthy.com Certified drawings will be issued on request.

Approval Certificate No. 202595 a subsidiary of Hamworthy plc © All details copyright Hamworthy plc.