No Network S8000
Issue:1
Defect : No Service / No network on model GT-S8000.; plugging in a Sim card the units doesn’t
receive any signal from the network; running calibration receive error “Check RF Cable”
Solution: Test* and eventually replace IC-Transcriver (TRT6285) U100; Code 1205-003297
Test*: Upgrade the units up to last release available, Check with an oscilloscope if the oscillator TCXO
(OSC100) works properly.
Misure: Check on pin 3 if there is a frequency of 19.2 Mhz even after the capacitor C142
Check on pin 4 is feeded (VCC) Vreg_Tcxo_2.8V
Check if the signal is present even on the pin 2 of the transceiver (RTR6285)
If the measure listed above are ok, check the feeding of Transceiver U100 /TRT6285
• VREG_RFRX1: 2.1V
• VREG_RFRX2: 2.7V
• VREG_MSMP: 2.6V