You are on page 1of 1

TEST CERTIFICATE

Test According to EN 779

Customer: M/S. Pr Pharma Engineers Private Limited

PO No: 886/1221/2020-21

Serial No: IC-011990 - IC-011995 Quantity : 06 No's.

PRODUCT: Manufacturer:
COMBINATION FILTER (Flange Type) AAF India Pvt Ltd
Filter Media: Over All Combination Filter Size : Fine Filter : 610 x 305 x 305 mm MOC :
Synthetic Media 610 x 305 x 355 mm Pre Filter: 540 x 235 x 40 mm Aluminium

Manufacturers Operating Data


Recommended Recommended
Initial Pressure Initial Pressure Temperature
Nominal Air Flow Rate : Final Pressure Final Pressure
drop (G4) : drop (M5) : Resistance:
drop(G4) : drop (M5) :
1000 CFM 65 Pa ± 10 % 250 Pa 75 Pa ± 10 % 450 Pa Ambient

Type Test Data


Test Air Flow :
Air Velocity: 500 FPM Air Temperature: 25°C
1000 CFM

Initial Initial Average Arrestance (G4) Average Efficiency (M5) @ 0.4µ Filter Class
Pressure drop Pressure drop
(G4) : (M5) :
90% 40 - 60 %
G4 & M5
65 Pa ± 10 % 75 Pa ± 10 %
Prepared By Approved By Test No: IC-011990 - IC-011995

RevansiddanaGouda C Umar Farooq.S


(Quality Officer (Quality Manager) Date: 24/2/2021

Note: These Combination filters are tested individually

AAF India Private Limited (CIN U29197KA2005PTC037575)


Plot no: 117 118,Bommasandra - Jigani link Road,
KIADB Industrial area, Karnataka India
Tel : 080-27839903 | info@aafindia.net