Energy Analysis
Dec. 14 2022

https://app.covetool.com/project/92735/report/?baseline=true 1/14
12/14/22, 3:59 PM Report

ANALYSIS SUMMARY

Location

Giza, El Omraniya, Giza Governorate, Egypt


Climate Zone

ASHRAE Climate Zone 2

80
Walk Score®
Very Walkable

Building Type

176
Overall Energy
Education

The current model is done using ASHRAE


2019 - IECC 2021 Equivalent energy code
assumptions. The current design is better
than the national average and can be
significantly improved by higher
performance of envelope, HVAC and
more. The building load is driven by
Equipment and Cooling.

https://app.covetool.com/project/92735/report/?baseline=true 2/14
12/14/22, 3:59 PM Report

BENCHMARKS
WHERE DO WE NEED TO BE?

Energy

416
National Average
83
2030 Target
55 Daylight
% 10 Glare
%

EUI is expressed as energy per square meter per Spatial Daylight Autonomy (sDA) describes the Annual Solar Exposure (ASE) refers to the
year. It is calculated by dividing the total energy percentage of floor area that receives at least 300 lux percentage of space that receives too much direct
consumed by the building in one year (measured in for at least 50% of the annual occupied hours. sunlight (1000 Lux or more for at least 250 occupied
kWh) by the total floor area of the building. The hours per year), which can cause glare or increased
most common unit for EUI is kWh/m²/year. cooling loads.
% of Educations

Measured Energy Use of Educations

https://app.covetool.com/project/92735/report/?baseline=true 3/14
12/14/22, 3:59 PM Report

ENERGY ANALYSIS

https://app.covetool.com/project/92735/report/?baseline=true 4/14
12/14/22, 3:59 PM Report

Water Use

Total Water Use (L/yr) LEED Points - WEc1-c2 Credit Indoor WUI (L/m²/yr) Stormwater Managed Onsite % Irrigation WUI (L/m²/yr)

58185.4 5 606.1 10 0

Education 58185 L/yr Indoor Reduction 37 % Education 606.1 L/m²/yr Total Runoff 8120 L/yr Total 0 L/yr
Cooling 0 L/yr Outdoor Reduction 0% Irrigation
Tower Water Use
Outdoor 0 L/yr
WU

https://app.covetool.com/project/92735/report/?baseline=true 5/14
12/14/22, 3:59 PM Report

2030 PALETTE
The strategies below are applicable to your building and location

Double Roof Earth Sheltering East/West Shading Form For Cooling Form For Heating Side Daylighting Controls

Building Facade Cool Roof Cross Ventilation Daylight from Multiple Sides Direct Gain: Glazing Side Daylighting

Solar Greenhouse Stack Ventilation Thermal Storage Wall Top Daylighting Top Daylighting Controls Green Roof

Indirect Gain: Sunspace Shading Devices

https://app.covetool.com/project/92735/report/?baseline=true 6/14
12/14/22, 3:59 PM Report

CLIMATE ANALYSIS
RELATIVE TEMPERATURE & HUMIDITY

This graph shows the outdoor comfort in Giza using the yearly range of temperatures and
humidities.

https://app.covetool.com/project/92735/report/?baseline=true 7/14
12/14/22, 3:59 PM Report

CLIMATE ANALYSIS
RADIATION BY SKY SEGMENT

This graph maps the radiation onto a sky dome to show the intensity of the direction and
intensity of solar radiation on a yearly basis around the cardinal points for Giza.

https://app.covetool.com/project/92735/report/?baseline=true 8/14
12/14/22, 3:59 PM Report

CLIMATE ANALYSIS
ADAPTIVE COMFORT

Adaptive Comfort chart showing the time of day and time of year with the greatest human comfort
for your location.

https://app.covetool.com/project/92735/report/?baseline=true 9/14
12/14/22, 3:59 PM Report

CLIMATE ANALYSIS
RADIATION BENEFIT

https://app.covetool.com/project/92735/report/?baseline=true 10/14
12/14/22, 3:59 PM Report

CLIMATE ANALYSIS
PSYCHROMETRIC CHART
10.10 % COMFORT - NO PASSIVE STRATEGIES

Impact of Design Strategies


% of additional comfort - higher is better

10.90 % EVAPORATIVE COOLING

7.12 % THERMAL MASS + NIGHT VENTILATION

6.96 % OCCUPANT USE OF FANS

37.31 % INTERNAL HEAT GAIN

2.60 % DESICCANT DEHUMIDIFICATION

8.63 % DEHUMIDIFICATION

This chart shows the relationship between dry bulb, humidity ratio, and enthalpy. The polygons
overlaid on the chart represent different strategies to increase comfort. Based on ASHRAE 55-
2013 under standard conditions.

https://app.covetool.com/project/92735/report/?baseline=true 11/14
12/14/22, 3:59 PM Report

https://app.covetool.com/project/92735/report/?baseline=true 12/14
12/14/22, 3:59 PM Report

CLIMATE ANALYSIS
WIND

The diagrams show the wind direction and intensity coming to the site. The number of hours
are reflected by the size of the rose, and the intensity is expressed in colors as shown in the
legend.