You are on page 1of 2

Technical V-guide selector

specification
Housing material:

3: 22-40 mm

4: 22-40 mm
1: 5-22 mm

2: 5-22 mm
short rod

short rod
Aluminium

long rod

long rod
V-guide
Dimensions:
61 x 77 x 61 mm (h X w X d)
Weight: 300 g/unit
Battery type:

maximum
O (mm)
2 x LR03 (AAA) 1.5V per unit

1300
1300
1300
1300
1300
1800
1800
1800
700
900
900
900
900
900
900
Operating time:
20 hrs continuous operation
Measuring distance:
50mm - 6000 mm

User's

Pulley datum diameter


Measuring accuracy:
Better than 0.5 mm or
0.2 degrees
Pulley diameter range: From
75 mm and larger (standard)
Pulley belt groove width:
6 mm - 40 mm (standard)
Manual
Laser class 2;
Output power: <1mW
ACOEM AB Laser wavelength: 600-650 nm

minimum
O (mm)

140
140
300
300
300
Östergårdsgatan 9

75
75
85
85
80
85
80
90
90
90
Box 7
SE-431 21 Mölndal

SPC, C/22, CX/X22


Sweden
Tel: +46 31 706 28 00

B/17, BX/X17
Z/10, ZX/X10

A/13, AX/X13
Belt profile
Fax: +46 31 706 28 50

25, 8V/25N
E-mail: info@fixturlaser.se

5V/15N
3V/9N
P-0172 FL PAT 2016 rev B

Web: www.fixturlaser.com

D/32
E/40
SPZ

SPB
SPA
Y/6

20
8
Pulley groove
width (mm)

12,7

16,3
9,7
10

13
15

17
20
22
25
32
40
6
8
9

600 - 650
Pulley Alignment Alignment process Safety
The P.A.T. uses two laser trans- Position both units with the When the units are mounted, The P.A.T. uses laser diodes with
mitters for projecting of laser spring action probes resting in turn on the lasers. Each laser a power output of less than 1.0
lines on the opposite laser unit. the same grove on both pulleys generates a line on the opposite mW. The laser classification is
By adjusting the pulleys so that and the units are facing each unit. When correctly aligned the Class 2, which is considered
the laserline coincides with the other as shown below. lines coincide with the reference safe for its intended use with
reference line on the oppo- marks on the labels on both only minor precautions re-
site laser unit, the pulleys are units. quired. These are:
aligned. If the belt transmission is mis-
aligned, start by correcting the
angular error.
Never stare directly into
Mounting of the the laser light source.
P.A.T. units. Never direct the laser into
Each unit is mounted on the anyone else’s eyes.
pulley as shown in the diagram
below. NOTE! The magnet,
Your system complies with the
which hold the unit to the
requirements in:
pulley, are very strong. Do not
• SS-EN-60825-1-1994
pinch your fingers! Ensure that the probes has set- • British Standards BS
tled correctly in the groove by 4803Parts 1 to 3
pushing the units a few millim- • Deutsche Industrie Norm
eters along the groove. DIN JEC 76 (CO) 6
• USA FDA Standard 21 CFR,
Ch 1,
Part 1040.10 and 1040.11

It is important that the pul-


leys are mounted correctly on
the shafts and that the shafts
are straight before starting the
alignment process. Wobbling or
warped pulleys affect the align-
ment quality severly.