You are on page 1of 6

Wiring diagram for overfill control system kit

Wiring diagram for analog and relay connections

Technical Specifications

DISPLAY AND CONTROL UNIT PROBE


Protection Rate: IP 67 Aluminium isolating head: 2”
Power consumption (display + probe) <30 Va. Isolation rate: IP 65
Standard Electric supply: 230/115 Vac Other optional connecting thread: 1”,11/4” and 11/2”
Optional versions: 48/24 Vcc - 18/48 Vcc Standard probe: flexible (Nylon)
Temperature range of function: 0º a 50ºC Max temperature in flexible standard probe: 50ºC
Electromagnetic compatibility: EN 61000-6-2, EN Optional Inox (rigid): stainless steel AISI-316
61000-6-3
Security Norms: EN 61010-1 Max temperature with stainless steel Probe: 125ºC
Material: PC-ABS
Measures (mm): 96 x 43 x 100 (DIN 43700)
Certifications: CE, UR, CSA

This manufacture definition is subject to change accordingly to specific installation needs.

60
Natural polyamide tube pack
Transparent polyamide flexible tube.
25, 50 and 100 meters.
Indivisible pack.

Reference : PAC6825NAT

CHARACTERISTICS
▪ Flexible pipe.
▪ Mechanical resistance: High
▪ Thermal properties: From -40ºC to + 100ºC.
▪ Chemical agents: Great resistance.
▪ Vacuum resistance: Up to 760 mmHg.
▪ Insulator: Electrical and thermal.
▪ Water absorption: Little.
▪ Gas permeability: Low.
▪ Vibration absorption.
APPLICATIONS
▪ Pneumatics.
▪ Hydraulics.
▪ Gas.
▪ Fluids
▪ Oils
▪ Lubricants
▪ Gasoline
▪ Brake circuits, ...
STANDARDS: DIN 74324
TOLERANCE:
▪ Ø ext. ± 0.05.
▪ Thickness ± 0.05.
▪ Double laser control of dimensions.
DECLARATION OF CONFORMITY

INPRO Research and Development, SL Pol.


Industrial El Malvar
C / Invierno 4.6
28500 Arganda del Rey (Madrid) - Spain

Declare under our sole responsibility that the device “LEVEL GAUGE” for oil,
Type: INPRO EDM-40
Manufacturing date: 2021
meets all the essential requirements with the following directives:
• Directive 2014/30/EU of the European Parliament and of the Council of 26 February 2014 on
electromagnetic compatibility.
• Directive 2014/35/EU of the European Parliament and of the Council of 26 February 2014 on
low voltage devices (LVD).
• Royal Decree 219/2013 Restrictions of Hazardous Substances ROHS.
The company is not liable for any accident caused by:
• Failure to follow the instructions contained in the documentation prepared by INPRO
Research and Development, SL
• Changes made to the machine without the prior approval of INPRO Research and
Development, SL
• Damage caused by maintenance and / or repairs by unauthorized personnel by INPRO
Research and Development, SL

The devices have been constructed with the following standards:


EN 12.514-1; UNE-EN 61010-1: 2011, UNE-EN 61010-031: 2004, EN 61293: 1994, EN 61326 to 1.2:
2006, EN 61000-6- 2: 2005, EN 61000-6-4: 2007, EN -ISO-9001:2015.

Quality manager
Signed in Arganda del Rey

You might also like