You are on page 1of 5

Below have totally 5 type exit button, please follow

guide based on the product picture


1. If use the press to exit button

It’s easy, just connect the two point to P1 and GND for Door 1

P2 and GND for Door 2 …

No matter negative and positive.

2. If use the Motion Sensor exit


Motion Sensor’s 4 wire connection:

1. Sensor’s Brown wire to 12V


2. Sensor’s Yello wire to GND
The above two wires are to power on the sensor, when do install, the motion sensor is at door
place, so suggest connecting to door reader. Parallel connect to door reader’s red and black
wire to get power.

3. Sensor’s Green wire to control panel’s P1 ( if for door 1, P2 is for Door 2 ….)
4. Sensor’s White wire to control panel’s GND

P1/P2/P3/P4 and Gnd are normally besides the reader connection terminals on control panel.
3. If use our infrared no touch button

the connection as below( Just use infrared exit’s 4 wires: +12V/GND/COM and NO, ignore other
wires ):

Infrared exit button’s 12V to Control Panel’s 12V

Infrared exit button’s GND to Control Panel’s GND

Infrared exit button’s NO to Control Panel’s PX(X=1, for 1 st door; X=2, for 2nd door … )

Infrared exit button’s COM to Control Panel’s GND( which besides P1/P2/P3/P4 ..。)
4. If use the touch exit button

Insert the 5-Pin cable as below.

Then:

Find the P1 GND( or P2 GND, P3 GND, P4 GND) on the control panel.

1. The Yellow wire above( COM) to the GND of control panel


2. The Orange wire above( NO) to the P1(or P2 or P3 or P4) of control panel.

Below is for power on the exit button


3. The Red wire above(12V) to 12V of control panel
4. The black wire above(GND) to GND of control panel
Totally 4 wires connection
5. If use the below metal exit button

Just use it’s two wires(NO and COM) , connect the two wires to P1 and GND for Door 1

NO and COM of exit button are the same color, No matter negative and
positive. Just one wire to P1, another wire to GND( if for door 1)

P2 and GND for Door 2 …