Exit Button Connection V4
It’s easy, just connect the two point to P1 and GND for Door 1
3. Sensor’s Green wire to control panel’s P1 ( if for door 1, P2 is for Door 2 ….)
4. Sensor’s White wire to control panel’s GND
P1/P2/P3/P4 and Gnd are normally besides the reader connection terminals on control panel.
3. If use our infrared no touch button
the connection as below( Just use infrared exit’s 4 wires: +12V/GND/COM and NO, ignore other
wires ):
Infrared exit button’s NO to Control Panel’s PX(X=1, for 1 st door; X=2, for 2nd door … )
Infrared exit button’s COM to Control Panel’s GND( which besides P1/P2/P3/P4 ..。)
4. If use the touch exit button
Then:
Just use it’s two wires(NO and COM) , connect the two wires to P1 and GND for Door 1
NO and COM of exit button are the same color, No matter negative and
positive. Just one wire to P1, another wire to GND( if for door 1)