Professional Documents
Culture Documents
GENERAL
The alarm dialler will in the pre-recorded speech identify itself using a digit 1-9
(ID code) as set by the user.
For activation by wire there are two alarm inputs (A and B).
For activation by remote control this is Alarm A
The alarm dialler is powered from the AC mains (230V / 50Hz) or from 12V
DC (as alternatively can be used for backup).
During the alarm the AC output (relay) will be activated during a pre-set timing.
1
GREEN LED
RED LED
BUZZER
Short beeps OK
OPERATION CODES
A) Program mode
Press: * 5 *
The green LED will light up, and two shorts beeps are heard from the buzzer
(=OK).
2
B) To leave the program mode
Press: 0
The green LED will turn off, and two shorts beeps are heard from the buzzer
(=OK).
When in program mode and no button are pressed within 15 sec, the unit will
leave the program mode automatically.
1) Enter program mode by pressing * 5 * (green LED will light up, and two
shorts beeps are heard from the buzzer)
2) Press # (the green LED will start flashing)
3) Enter the telephone number max 17 digits. Using * will give a 3sec pause.
End by using #.
4) Set the alarm input that will activate the telephone number:
Press 1 when alarm input A should activate the alarm
Press 2 when alarm input B should activate the alarm
Press 3 when input A or B should activate the alarm
End by pressing #
5) Press the memory position 1-14 to store the number/alarm input, end by
pressing # (the green LED will stop flashing, and to be continuously on)
6) To program next number start from 2) above, alternatively ID speech
program (E2 below), Relay program (F2 below), or press 0 to leave the
program mode (green LED will turn off).
E) Selection of ID speech
1) Enter program mode by pressing: * 5 * (green LED will light up, and two
shorts beeps are heard from the buzzer)
2) Press: * (green LED will start flashing)
3) Press any digit 0-9 as ID (two short beeps will be heard as OK, and the green
LED will stop flashing to be continuously on). If no ID speech set ID=0
4) Press 0 to leave the program mode, alternatively program Telephone
numbers/Alarm input (C2 above), or Alarm relay (F2 below).
3
F) To program the alarm relay
1) Enter program mode by pressing: * 5 * (green LED will light up, and two
shorts beeps are heard from the buzzer)
2) Press: 1 (green LED will start flashing)
3) Set the alarm relay function 1-3:
Press 1 for relay activation when alarm A is activated
Press 2 for relay activation when alarm B is activated
Press 3 for relay activation when alarm A or B is activated
4) End by pressing #
5) Set how long the relay should be on (minutes) after activation:
Press 0-60 (If no activation press 0)
Press # (the green LED will be continuously on, and the buzzer will give two
short beeps)
6) Press 0 to leave the program mode, alternatively program Telephone
numbers/Alarm input (C2 above), or ID speech program (E2 above)
ACKNOWLEDGEMENT OF AN ALARM
A) On the keyboard
B) By telephone
BASIC RESET
A basic reset (total reset) that will erase any telephone numbers in the memory,
set the ID codes to 0, and set the relay activation when any alarm input is
present to 1 minute.
Disconnect the alarm transmitter from the power. Press and hold the buttons 4,5,
6 and connect the power. Continue to press the buttons until two beeps are heard
and the green lED will light up.
© Ondico AB 2002-03-04
C:\ DOKUMENT\PRODUKTINFO\OND-9005