The document provides fault codes, descriptions, and resolutions for errors that may occur on a VCT toaster control board. Fault codes range from "Err 1" to "Err 10" and "CHEC" or "PH", with issues including internal control board errors, improper dip switch settings, thermocouple faults, safety switch faults, and excessive compartment temperature. Resolutions include replacing or testing components like the control board, thermocouples, relays, switches, and fan. Adjusting dip switches or inspecting wire harnesses may also resolve some issues.
The document provides fault codes, descriptions, and resolutions for errors that may occur on a VCT toaster control board. Fault codes range from "Err 1" to "Err 10" and "CHEC" or "PH", with issues including internal control board errors, improper dip switch settings, thermocouple faults, safety switch faults, and excessive compartment temperature. Resolutions include replacing or testing components like the control board, thermocouples, relays, switches, and fan. Adjusting dip switches or inspecting wire harnesses may also resolve some issues.
The document provides fault codes, descriptions, and resolutions for errors that may occur on a VCT toaster control board. Fault codes range from "Err 1" to "Err 10" and "CHEC" or "PH", with issues including internal control board errors, improper dip switch settings, thermocouple faults, safety switch faults, and excessive compartment temperature. Resolutions include replacing or testing components like the control board, thermocouples, relays, switches, and fan. Adjusting dip switches or inspecting wire harnesses may also resolve some issues.
VCT-20/100/200/250/2000 New Style Control Board P/N 7000739 (4070142)
Fault Codes
Fault Code Fault Code Description Resolution
“Err 1” flashes on the display Internal Control Board error Replace Control Board “Err 2” flashes on the display Internal Control Board error Replace Control Board “Err 3” flashes on the display The programming dip switches Adjust the dip switches on the control board on the universal control board to properly match the toaster’s Mfg # as per P/N 7000739 (4070142) are not document P/N 1011052. If the dip switches adjusted properly. The dip were adjusted properly but the error switches must be adjusted to continues, then replace the control board. match the toaster’s Mfg # on the specification label. Refer to document P/N 1011052 for specific settings. If the dip switches were adjusted correctly then the control board has failed. “Err 4” flashes on the display The platen thermocouple is Test the platen thermocouple for shorts to shorted to chassis ground or the chassis ground. Replace platen control board has failed. thermocouple if it is found to be shorted to chassis ground. If the platen thermocouple is not shorted to ground then replace control board. Refer to service manual for detailed troubleshooting “Err 5” flashes on the display The platen thermocouple is Test platen thermocouple for continuity disconnected, loose, or open or then re-connect. Replace if no continuity. the platen relay is shorted closed Replace platen relay if shorted closed. Refer to service manual for detailed troubleshooting “Err 6” flashes on the display Internal Control Board error Replace Control Board “Err 7” flashes on the display Internal Control Board error Replace Control Board “Err 8” flashes on the display Internal Control Board error Replace Control Board “Err 9 or PH” flashes on the display The programming dip switches First ensure that the dip switches on the on the universal control board control board are adjusted properly to P/N 7000739 (4070142) are not match the toaster’s Mfg # as per document adjusted properly. The dip P/N 1011052. If the dip switches were switches must be adjusted to adjusted properly then perform the match the toaster’s Mfg # on the following: specification label. Refer to VCT-100/200/250: Inspect the front, rear document P/N 1011052 for safety switches and its wiring for specific settings. If the dip engagement & continuity. VCT-20/2000: switches were adjusted Inspect the top safety switch and its wiring correctly, then the AC Isolator for engagement & continuity. Replace if Board is not receiving 200-250 faulty. Also inspect the 4 wire harness for VAC, or is not continuity. Refer to service manual for receiving/regulating the 5 VDC, detailed troubleshooting. or has failed. “Err 10” flashes on the display Internal Control Board error Replace Control Board “CHEC” The electrical compartment Inspect the top cooling fan for operation and ambient temperature is above for proper airflow direction. Replace fan if it 140 F (60 C) due to poor airflow receives 200-250 VAC but does not rotate. or the control board has failed. Refer to service manual for detailed troubleshooting