VCT-20/100/200/250/2000 New Style Control Board P/N 7000739 (4070142)

Fault Codes

Fault Code Fault Code Description Resolution


“Err 1” flashes on the display Internal Control Board error Replace Control Board
“Err 2” flashes on the display Internal Control Board error Replace Control Board
“Err 3” flashes on the display The programming dip switches Adjust the dip switches on the control board
on the universal control board to properly match the toaster’s Mfg # as per
P/N 7000739 (4070142) are not document P/N 1011052. If the dip switches
adjusted properly. The dip were adjusted properly but the error
switches must be adjusted to continues, then replace the control board.
match the toaster’s Mfg # on the
specification label. Refer to
document P/N 1011052 for
specific settings. If the dip
switches were adjusted correctly
then the control board has
failed.
“Err 4” flashes on the display The platen thermocouple is Test the platen thermocouple for shorts to
shorted to chassis ground or the chassis ground. Replace platen
control board has failed. thermocouple if it is found to be shorted to
chassis ground. If the platen thermocouple
is not shorted to ground then replace control
board. Refer to service manual for detailed
troubleshooting
“Err 5” flashes on the display The platen thermocouple is Test platen thermocouple for continuity
disconnected, loose, or open or then re-connect. Replace if no continuity.
the platen relay is shorted closed Replace platen relay if shorted closed.
Refer to service manual for detailed
troubleshooting
“Err 6” flashes on the display Internal Control Board error Replace Control Board
“Err 7” flashes on the display Internal Control Board error Replace Control Board
“Err 8” flashes on the display Internal Control Board error Replace Control Board
“Err 9 or PH” flashes on the display The programming dip switches First ensure that the dip switches on the
on the universal control board control board are adjusted properly to
P/N 7000739 (4070142) are not match the toaster’s Mfg # as per document
adjusted properly. The dip P/N 1011052. If the dip switches were
switches must be adjusted to adjusted properly then perform the
match the toaster’s Mfg # on the following:
specification label. Refer to VCT-100/200/250: Inspect the front, rear
document P/N 1011052 for safety switches and its wiring for
specific settings. If the dip engagement & continuity. VCT-20/2000:
switches were adjusted Inspect the top safety switch and its wiring
correctly, then the AC Isolator for engagement & continuity. Replace if
Board is not receiving 200-250 faulty. Also inspect the 4 wire harness for
VAC, or is not continuity. Refer to service manual for
receiving/regulating the 5 VDC, detailed troubleshooting.
or has failed.
“Err 10” flashes on the display Internal Control Board error Replace Control Board
“CHEC” The electrical compartment Inspect the top cooling fan for operation and
ambient temperature is above for proper airflow direction. Replace fan if it
140 F (60 C) due to poor airflow receives 200-250 VAC but does not rotate.
or the control board has failed. Refer to service manual for detailed
troubleshooting