Professional Documents
Culture Documents
SERVICE BULLETIN
**CONF ALL
INSPECTION REPORT
SERVICE BULLETIN No.: A320−53−1299
A/C MSN: 4061
RETURN TO:
FLIGHT CYCLES: 20308 AIRBUS
FLIGHT HOURS: 43272:41 CUSTOMER SERVICE ENGINEERING
DOORS − FUSELAGE − CWB − WINDOWS
FINDINGS: YES (REPLACE PART) NO ACTION 1 ROND POINT MAURICE BELLONTE
DATE OF INSPECTION: 7-Jul-2021 31707 BLAGNAC CEDEX
FRANCE
PLACE OF INSPECTION: SHJ FAX +33 (0)5 61 93 36 14
E−mail: inspection.results@airbus.com
INSPECTOR: W.Dagmawi
AMBIENT TEMPERATURE: 27 °C
COT WITH 480 kHz CALCULATE
COT WITH 60 kHz REPLACE
480=...[MS/m], IF 60 >20 MS/m DIFFERENCE NO ACTION
ITEM PART NUMBER ZONE/LOCATION 60 [MS/m] PART
OR 34.5% IACS = 480 − 60
REFER TO INSPECTION FLOWCHART
1 D535−70206−200−00 FR70, Z310 (REFER TO FIG A−GBAAA) 33 % IACS
19 D534−77176−200−00 FR59 TO FR60, STGR41RH, Z150 (REFER TO FIG A−GCAAA) N/A
20 D535−85131−200−01 FR79, STGR7LH TO RH, Z310 (REFER TO FIG A−GDAAA) 31 % IACS
21 D535−85264−210−00 FR80, UPPER, Z310 (REFER TO FIG A−GEAAA) 33 % IACS
22 D535−85264−212−00 FR80, MIDDLE, Z310 (REFER TO FIG A−GEAAA) 33.2 % IACS
23 D535−85264−214−00 FR80, LOWER, Z310 (REFER TO FIG A−GEAAA) 33.3 % IACS