You are on page 1of 1

LEGEND

SUBSTATION CONTROL PANEL SUBSTATION EQUIPMENT


PROFIBUS 90° BUS CONNECTOR WITH
DIAGNOSTIC PLUG

FIBRE PORT
CONTINUED ON
REF DRG 245-ECS-9001 ETHERNET PORT

TER01

NATOR
ACTIVE PROFIBUS DP TERMINATOR

VE
DP ACTI
TERMI
NUED

NUED
D003

D103
CONTI

CONTI
NOTES

1. REFER DRAWING 000-EST-0261 FOR PROFIBUS


CONNECTION DETAILS.

2. PROFIBUS NODE TABLES ARE NOT INTENDED TO


REFLECT THE PANEL ARRANGEMENT WITHIN THE
SWITCHBOARD OR MCC'S.

3. MAXIMUM NUMBER OF DOL DRIVES PER PROFIBUS


DP LOOP TO BE 20.
02A 02B 04
NTERFACE MODULE

NTERFACE MODULE

4. MAXIMUM NUMBER OF VSD DRIVES PER PROFIBUS


DP LOOP TO BE 10.
DPY COUPLER
D004

D104

RACK 03

245 SUBSTATION 480V MCC 245-MCC-9001


M 153-2

M 153-2

SPACE
I
I
I
I

EQUIPMENT NODE
NUMBER No,
2251

2271

245CPL9001-D301
245-MCC-9001 10
INCOMER
TER02 245CPL9001-D302
24VDC

NATOR
VE
REF DRG
245CPL9001-D401 1 245-PP-9011 10
DP ACTI
245-ECS-9012
TERMI
2 245-PP-9013 11

3 245-PP-9014 12
2391

4 245-PP-9019 13
24VDC REF DRG
245-ECS-9012 5 1.5kW SPARE 14

02A 02B 04 6 2.2kW SPARE 15


NTERFACE MODULE

NTERFACE MODULE

7 3kW SPARE 16
DPY COUPLER

8 5.5kW SPARE 17
RACK 04

M 153-2

M 153-2

SPACE

9 11kW SPARE 18
D005

D105

I
I
I
I

10 30kW SPARE 19
2291

2311

11

12
24VDC
REF DRG 13
245-ECS-9012
koch

14
marcus.

TER03 245CPL9001-D402 15
NATOR
VE

16
DP ACTI
27 PM

TERMI

17
52:
1:

18
16/10/2018

2411

19
24VDC REF DRG
245-ECS-9012 20
dgn
ng\ECS Control Sys & PCCs\245\245-ECS-9002.
na de Cobre CPC Scope\02. Drafti

CONTINUED ON
REF DRG 245-ECS-9003

oduced.
ns

y
n
CLIENT

lnotbe passed on i

t
MINA DE COBRE PANAMA

em ai
DRAWN M KOCH 16.10.18

d par
d.

ect
NGS

ylt

oj

om
y pr
ng r

ocess E & Ipt

r
WASHCSA DOWN/REFUELLING

he pr

hi

r
REFERENCE DRAW I

ovalf
l

o any t
nal
CHECKED
ects\C1443B Mi

K REDWOOD 16.10.18

awi
245-ECS-9021 245-CPL-9001 TERMINATION DIAGRAMS SHEET 1 MINERA PANAMA S.A
ONS

ort

gi
SUBSTATION CTRL PANEL 245-CPL-9001

en appr
s dr

i
thas been or
yf

m att
ABN 53 131 815 337
SI

DISCIPLINE

d.
Thi

el
REVI

245-ECS-9011 245-CPL-9001 SCHEMATIC DIAGRAMS SHEET 1 J TAN 16.10.18

t
CONNECTION DIAGRAM SHEET 2

lbe used sol

yl
ENGINEER

ng shal
y ofPr

t
or

t
QUALITY ENGINEERING SOLUTIONS

ocess E & Ipt


i
orwr
cf
GHT C

oni
PRINCIPAL
SCALE DRG. No. CLIENT PROJECT NUMBER

t
A DINGLEY 16.10.18 REV. No.

i
awi
0 ISSUED FOR CONSTRUCTION MK KR JT 16.10.18 245-EGA-9002 245-CPL-9001 GENERAL ARRANGEMENT

ch i
oper

houtpr
r
www.ProcessEI.com.au ENGINEER

ect
COPYRI
\Proj

orwhi

s dr
245-ECS-9002 1824 0

any el
N.T.S

tshal
he pr
Tel: +61 8 9344 6030 A1

Thi

t
REV DRN CHK ENG DATE REV DRN CHK ENG DATE DRAWING No. DESCRIPTION CLIENT

wi
DESCRIPTION DESCRIPTION

Pr
J:

f
t

You might also like