You are on page 1of 28

VL555 Translator Details

Data Log
Recorder Interval ManagerLabel ModuleLabel RegisterLabel
Factory Information Factory 1 FAC1 DeviceType
Factory Information Factory 1 FAC1 Compliance
Factory Information Factory 1 FAC1 Options
Factory Information Factory 1 FAC1 Revision
Factory Information Factory 1 FAC1 SerialNum
Factory Information Factory 1 FAC1 ION Version
Factory Information Factory 1 FAC1 Template
Factory Information Factory 1 FAC1 Modbus FW Version
Factory Information Factory 1 FAC1 Service Number
Factory Information Factory 1 CB Market
Factory Information Factory 1 COM21 FW Version
Factory Information Factory 1 COM21 Serial Number
Factory Information Factory 1 COMbox status
Factory Information Factory 1 Current Rating
Factory Information Factory 1 Instantaneous rating
Factory Information Factory 1 Number of Poles
Factory Information Factory 1 Sensor Rating
Factory Information Factory 1 Trip Unit Serial Number
Factory Information Factory 1 Type of trip unit

Clocks Clock CL1 Local Time

Clocks Clock CL1 Universal Time


Demand Demand I Avg Demand
Maximums Max current I average mx
Maximums Max current I gnd fault mx
Maximums Max current I mx
Maximums Max current I neutral mx
Maximums Max current I unbal mx
Maximums Max Demand I Demand mx
COM21-ETU Comm
Counters error counter COM21-ETU Comm error counter
Breaker operations Breaker operations caused by a
Counters caused by a trip trip
Number of short circuit
Counters trips Number of short circuit trips
Number of overload
Counters trips Number of overload trips
Number of ground fault
Counters trips Number of ground fault trips
Modbus Comm error
Counters counter Modbus Comm error counter
Counters Operating hours Operating hours
Digital Outputs Breaker Status Breaker Position
Digital Outputs Breaker Status Breaker Status
Digital Outputs Breaker Status Breaker status Closed
Digital Outputs Breaker Status Breaker status Not ready
Digital Outputs Breaker Status Breaker status Opened
Digital Outputs Breaker Status Breaker status Tripped
Digital Outputs Breaker Status Ground fault trip status
Digital Outputs Breaker Status Instantaneous trip status
Digital Outputs Breaker Status Long Time Trip Status
Digital Outputs Breaker Status MODBUS Write Protection
Digital Outputs Breaker Status Overload warning
Digital Outputs Breaker Status Short time trip status
Digital Outputs Breaker Status Thermal Trip Status
Digital Outputs Breaker Status Trip Current

Digital Outputs Breaker Status Trip Log 1 Time


Digital Outputs Breaker Status Trip Log 1 Reason

Digital Outputs Breaker Status Trip Log 2 Time


Digital Outputs Breaker Status Trip Log 2 Reason

Digital Outputs Breaker Status Trip Log 3 Time


Digital Outputs Breaker Status Trip Log 3 Reason

Digital Outputs Breaker Status Trip Log 4 Time


Digital Outputs Breaker Status Trip Log 4 Reason

Digital Outputs Breaker Status Trip Log 5 Time


Digital Outputs Breaker Status Trip Log 5 Reason
Digital Outputs Breaker Status Trip Phase Number
Digital Outputs Breaker Status Trip status
Digital Outputs Breaker Status Trip unit mode
Digital Outputs Breaker Status Trip unit status
Digital Outputs Breaker Status Write Protect
Digital Outputs Breaker Status ZSI output status
Digital Outputs Breaker Status ZSI input status
Digital Outputs Warnings Trip Unit Ground Fault
Digital Outputs Warnings Trip Unit Overload
Digital Outputs Warnings Trip Unit Overload Neutral
Digital Outputs ZSI module Gnd fault enabled
Labels Alarm Labels Trip unit

Setpoints Ground Fault Setpoint Ground Fault Type


Communications Communications Baud Rate
Communications Communications Parity
Communications Communications Unit ID
Diagnostics Diagnostics COM21 is OK
COM21-ETU Communication is
Diagnostics Diagnostics OK
Diagnostics Diagnostics COM21 Label
Power Meter Values Power Meter Values I Neutral
Power Meter Values Power Meter Values I Gnd
Power Meter Values Power Meter Values Ia
Power Meter Values Power Meter Values I avg
Power Meter Values Power Meter Values Ib
Power Meter Values Power Meter Values Ic
Power Meter Values Power Meter Values I unbal
Power Meter Values Power Meter Values Max current a,b,c
Power Meter Values Power Meter Values Max current phase number
Power Meter Values Power Meter Values Volts mode
Protective/Extended
Settings Protective Settings Continuous Current Rating
Protective/Extended
Settings Protective Settings Time lag class tR A
Protective/Extended
Settings Protective Settings Thermal memory A
Protective/Extended
Settings Protective Settings Delay time tsd (S-trip) A
Protective/Extended
Settings Protective Settings I^2t curve for S A
Protective/Extended
Settings Protective Settings Delay time tg1A
Protective/Extended
Settings Protective Settings I^2t curve for G A
Protective/Extended
Settings Protective Settings I-trip li (instantaneous) A
Protective/Extended S-trip lsd (delayed short circuit
Settings Protective Settings trip) A
Protective/Extended
Settings Protective Settings Ground fault lg1A
Resets Breaker Open Breaker Open
Resets Breaker Close Breaker Close
Resets Clear Trip Counters Clear Trip Counters
Resets MnMx Rset MnMx Rset
Resets Sync Time Stamp Sync Time Stamp
Resets Reset trips Reset trips
Clear last trip in the trip
Resets unit Clear last trip in the trip unit

Resets Clear all Trip Counters Clear all Trip Counters


Resets ZSI Enable ZSI Enable
Set ZSI output (timeout
Resets 30sec) Set ZSI output (timeout 30sec)
Resets Reset ZSI output Reset ZSI output
ModbusA RequestTy
Name ddr Format pe IONHandle Mask
FAC1 DeviceType 405250 UINT16 R 4864 0xFFF0
4865
4866
4867
4868
30510
4989
FAC1 Modbus FW Version 405249 ASCII R 4935
4933
Circuit Breaker Market 405087 U16-21 R 4943 0xFF00
COM21 FW Version 405272 ASCII R 4960
COM21 serial number 405261 ASCII R 4956
COMbox status 405167 U16-21 R 4944 0xFF00
Current Rating 405082 U16-21 R 4958
Instantaneous rating 405086 U16-21 R 4945
Number of Poles 405085 U16-21 R 4952 0xFF00
Sensor Rating 405081 U16-21 R 4954
Trip Unit Serial Number 405241 ASCII R 4942
Type of trip unit 405083 U16-21 R 4957
DateTime3_SIEME
CL1 Local Time 405163 NSBCD_UTC RW 23421
DateTime3_SIEME
CL1 Universal Time 405163 NSBCD_LOCAL RW 23420
I Avg Demand 405016 U16-21 R 22659
I average mx 405018 U16-21 R 22757
I gnd fault mx 405020 U16-21 R 22756
I mx 405021 U16-21 R 22751
I neutral mx 405019 U16-21 R 22755
I Unbalance mx % 405017 U16-21 R 22758 0x00FF
I Demand mx 405022 U16-21 R 137363457

COM21-ETU Comm error counter 405069 U16-21 R 141558017

Breaker operations caused by a trip 405065 U16-21 R 23251


Number of short circuit trips 405061 U16-21 R 23256

Number of over current trips 405063 U16-21 R 23257

Number of ground fault trips 405064 U16-21 R 23258

Modbus Comm error counter 405068 U16-21 R 141557761


Operating hours 405066 U32-4321 R 23253
Breaker Position 405001 U16-21 R 65547 0x0003
Breaker Status 405001 U16-21 R 31542 0x000C
Breaker status Closed 405001 MaskedBool R 31559 0x0008
Breaker status Not ready 405001 MaskedBool R 31557 0x0000
Breaker status Opened 405001 MaskedBool R 31558 0x0004
Breaker status Tripped 405001 MaskedBool R 31560 0x000C
Ground fault trip status 405013 MaskedBool R 32131 0x0008
Instantaneous trip status 405013 MaskedBool R 32129 0x0002
Long Time Trip Status 405013 MaskedBool R 65548 0x0001
MODBUS Write enable 405167 U16-21 R 31549 0x00FF
Over current warning 405001 MaskedBool R 31546 0x0080
Short time trip status 405013 MaskedBool R 32130 0x0004
Thermal Trip Status 405013 MaskedBool R 65549 0x0080
Trip Current 405009 U16-21 R 31525
DateTime3_SIEME
Trip Log 1 Time 405101 NSBCD_LOCAL R 32100
Trip Log 1 Reason 405105 U16-21 R 32101
DateTime3_SIEME
Trip Log 2 Time 405107 NSBCD_LOCAL R 32102
Trip Log 2 Reason 405111 U16-21 R 32103
DateTime3_SIEME
Trip Log 3 Time 405113 NSBCD_LOCAL R 32104
Trip Log 3 Reason 405117 U16-21 R 32105
DateTime3_SIEME
Trip Log 4 Time 405119 NSBCD_LOCAL R 32106
Trip Log 4 Reason 405123 U16-21 R 32107
DateTime3_SIEME
Trip Log 5 Time 405125 NSBCD_LOCAL R 32108
Trip Log 5 Reason 405129 U16-21 R 32109
Trip Phase Number 405010 U16-21 R 32116 0xFF00
Trip status 405001 U16-21 R 31551 0x7000
Trip unit mode 405001 U16-21 R 31550 0x0800
Trip unit status 405010 U16-21 R 65537 0x00FF
Write Protect 405001 U16-21 R 65542 0x0400
ZSI output status 405011 MaskedBool R 24630 0x1000
ZSI input status 405011 MaskedBool R 24631 0x2000
Trip Unit Ground Fault 405008 MaskedBool R 65555 0x0040
Trip Unit Overload 405008 MaskedBool R 65551 0x0001
Trip Unit Overload Neutral 405008 MaskedBool R 65552 0x0002
ZSI gnd fault enable 405083 U16-21 R 24633 0x0001
14000

Ground Fault Type 405054 MaskedBool R 146800641 0x0100


Baud Rate 405162 U16-21 RW 31111 0xFF00
Parity 405162 U16-21 RW 31112 0x00FF
Unit ID 405161 U16-21 RW 29191 0xFF00
COM21 is OK 405023 U16-21 R 23592 0xFF00

COM21-ETU Communication is OK 405023 U16-21 R 23595 0x00FF


COM21 Label 405201 ASCII RW 65546
I Neutral 405006 U16-21 R 22566
I ground Fault 405007 U16-21 R 24143
Ia 405002 U16-21 R 22536
I avg 405015 U16-21 R 22539
Ib 405003 U16-21 R 22537
Ic 405004 U16-21 R 22538
I Unbalance % 405017 U16-21 R 22565 0xFF00
Max current a,b,c 405005 U16-21 R 22563
Max current phase number 405014 U16-21 R 22562 0xFF00
30720

Continuous Current Rating 405041 U16-21 R 65544

Time lag class tR PSA 405042 U16-21 R 29688

Thermal memory PSA 405051 MaskedBool R 29692 0x0001

Delay time tsd PSA 405045 U16-21 R 29697

Short Time Delay Mode 405046 MaskedBool R 29698 0x0100

Delay time tg1 PSA 405048 U16-21 R 29703

Ground Fault Delay Mode 405046 MaskedBool R 29708 0x0001

I-trip li (instantaneous) PSA 405043 U16-21 R 29694


S-trip lsd (delayed short circuit trip)
PSA 405044 U16-21 R 29696

Ground fault lg1 PSA 405047 U16-21 R 29702


26807
26808
Clear Trip Counters 405141 U16-21 W 176160769
MnMx Rset 405141 U16-21 W 176161025
Sync Time Stamp 405141 U16-21 W 176161281
Reset trips 405141 U16-21 W 176161537

Clear last trip in the trip unit 405142 U16-21 W 176161793

Clear all Trip Counters 405142 U16-21 W 176162049


ZSI Enable 405143 U16-21 RW 176162305

Set ZSI output (timeout 30sec) 405143 U16-21 W 176164097


Reset ZSI output 405143 U16-21 W 176164353
EnumNa NumberOfR
Scale Multiplier me egisters
16

256
5
8
256

256

8
0.125

0.25
12

128

TripReason

TripReason

TripReason

TripReason

TripReason
256
256

256
256

32

256

256

0.1
1
1
1
1

1
1
VL586 Translator Details
Data Log
Recorder Interval ManagerLabel ModuleLabel RegisterLabel
Factory Information Factory 1 FAC1 DeviceType
Factory Information Factory 1 FAC1 Compliance
Factory Information Factory 1 FAC1 Options
Factory Information Factory 1 FAC1 Revision
Factory Information Factory 1 FAC1 SerialNum
Factory Information Factory 1 FAC1 ION Version
Factory Information Factory 1 FAC1 Template
Factory Information Factory 1 FAC1 Modbus FW Version
Factory Information Factory 1 FAC1 Service Number
Factory Information Factory 1 CB Market
Factory Information Factory 1 COM21 FW Version
Factory Information Factory 1 COM21 Serial Number
Factory Information Factory 1 COMbox status
Factory Information Factory 1 Current Rating
Factory Information Factory 1 Instantaneous rating
Factory Information Factory 1 Number of Poles
Factory Information Factory 1 Sensor Rating
Factory Information Factory 1 Trip Unit Serial Number
Factory Information Factory 1 Type of trip unit
Clocks Clock CL1 Local Time
Clocks Clock CL1 Universal Time
Demand Demand I Avg Demand
Maximums Max current I average mx
Maximums Max current I gnd fault mx
Maximums Max current I mx
Maximums Max current I neutral mx
Maximums Max current I unbal mx
Maximums Max Demand I Demand mx
COM21-ETU Comm COM21-ETU Comm error
Counters error counter counter
Breaker operations Breaker operations caused by a
Counters caused by a trip trip
Number of short circuit
Counters trips Number of short circuit trips
Number of overload
Counters trips Number of overload trips
Number of ground fault
Counters trips Number of ground fault trips
Modbus Comm error
Counters counter Modbus Comm error counter
Counters Operating hours Operating hours
Digital Outputs Breaker Status Breaker Position
Digital Outputs Breaker Status Breaker Status
Digital Outputs Breaker Status Breaker status Closed
Digital Outputs Breaker Status Breaker status Not ready
Digital Outputs Breaker Status Breaker status Opened
Digital Outputs Breaker Status Breaker status Tripped
Digital Outputs Breaker Status Ground fault trip status
Digital Outputs Breaker Status Instantaneous trip status
Digital Outputs Breaker Status Long Time Trip Status
Digital Outputs Breaker Status MODBUS Write Protection
Digital Outputs Breaker Status Overload warning
Digital Outputs Breaker Status Short time trip status
Digital Outputs Breaker Status Thermal Trip Status
Digital Outputs Breaker Status Trip Current
Digital Outputs Breaker Status Trip Log 1 Time
Digital Outputs Breaker Status Trip Log 1 Reason
Digital Outputs Breaker Status Trip Log 2 Time
Digital Outputs Breaker Status Trip Log 2 Reason
Digital Outputs Breaker Status Trip Log 3 Time
Digital Outputs Breaker Status Trip Log 3 Reason
Digital Outputs Breaker Status Trip Log 4 Time
Digital Outputs Breaker Status Trip Log 4 Reason
Digital Outputs Breaker Status Trip Log 5 Time
Digital Outputs Breaker Status Trip Log 5 Reason
Digital Outputs Breaker Status Trip Phase Number
Digital Outputs Breaker Status Trip status
Digital Outputs Breaker Status Trip unit mode
Digital Outputs Breaker Status Trip unit status
Digital Outputs Breaker Status Write Protect
Digital Outputs Breaker Status ZSI output status
Digital Outputs Breaker Status ZSI input status
Digital Outputs Warnings Neutral overload
Digital Outputs Warnings Neutral pre-alarm
Digital Outputs Warnings Overload Status
Digital Outputs Warnings Phase A overload
Digital Outputs Warnings Phase A pre-alarm
Digital Outputs Warnings Phase B overload
Digital Outputs Warnings Phase B pre-alarm
Digital Outputs Warnings Phase C overload
Digital Outputs Warnings Phase C pre-alarm
Digital Outputs Warnings Prealarm Status
Digital Outputs Warnings Trip Unit Ground Fault
Digital Outputs Warnings Trip Unit Overload
Digital Outputs Warnings Trip Unit Overload Neutral
Digital Outputs ZSI module Gnd fault enabled

Setpoints Ground Fault Setpoint Ground Fault Alarm Delay

Setpoints Ground Fault Setpoint Ground Fault Alarm Setpoint

Setpoints Ground Fault Setpoint Ground Fault Type

Setpoints Ground Fault Setpoint Ground Fault Alarm Enable


Communications Communications Baud Rate
Communications Communications Parity
Communications Communications Unit ID
Diagnostics Diagnostics COM21
COM21-ETUis OKCommunication is
Diagnostics Diagnostics OK
Diagnostics Diagnostics COM21 Label
Power Meter Values Power Meter Values I Neutral
Power Meter Values Power Meter Values I Gnd
Power Meter Values Power Meter Values Ia
Power Meter Values Power Meter Values I avg
Power Meter Values Power Meter Values Ib
Power Meter Values Power Meter Values Ic
Power Meter Values Power Meter Values I unbal
Power Meter Values Power Meter Values Max current a,b,c
Power Meter Values Power Meter Values Max current phase number
Power Meter Values Power Meter Values Volts mode
Labels Alarm Labels Trip unit
Protective/Extended
Settings EP Over I pre-alarm EP Over I pre-alarm
Protective/Extended
Settings EP Over I pre-alarm EP Over I pre-alarm enable
Protective/Extended
Settings Protective Settings Continuous Current Rating
Protective/Extended
Settings Protective Settings Instantaneous Enable
Protective/Extended
Settings Protective Settings Delay time tg1A
Protective/Extended
Settings Protective Settings Delay time tsd (S-trip) A
Protective/Extended
Settings Protective Settings Ground fault lg1A
Protective/Extended
Settings Protective Settings I-trip li (instantaneous) A
Protective/Extended
Settings Protective Settings I^2t curve for G A
Protective/Extended
Settings Protective Settings I^2t curve for S A
Protective/Extended S-trip lsd (delayed short circuit
Settings Protective Settings trip) A
Protective/Extended
Settings Protective Settings S-trip lsd enable A
Protective/Extended
Settings Protective Settings Thermal memory A
Protective/Extended
Settings Protective Settings Time lag class tR A
Resets Breaker Open Breaker Open
Resets Breaker Close Breaker Close
Resets Clear Trip Counters Clear Trip Counters
Resets MnMx Rset MnMx Rset
Resets Sync Time Stamp Sync Time Stamp
Resets Reset trips Reset trips
Clear last trip in the trip
Resets unit Clear last trip in the trip unit

Resets Clear all Trip Counters Clear all Trip Counters


Resets ZSI Enable ZSI Enable
Set ZSI output (timeout
Resets 30sec) Set ZSI output (timeout 30sec)
Resets Reset ZSI output Reset ZSI output
Modbus RequestT
Name Addr Format ype IONHandle Mask Scale
FAC1 DeviceType 405250 UINT16 R 4864 0xFFF0 16
4865
4866
4867
4868
30510
4989
FAC1 Modbus FW Version 405249 ASCII R 4935
4933
Circuit Breaker Market 405087 U16-21 R 4943 0xFF00 256
COM21 FW Version 405272 ASCII R 4960
COM21 serial number 405261 ASCII R 4956
COMbox status 405167 U16-21 R 4944 0xFF00 256
Current Rating 405082 U16-21 R 4958
Instantaneous rating 405086 U16-21 R 4945
Number of Poles 405085 U16-21 R 4952 0xFF00 256
Sensor Rating 405081 U16-21 R 4954
Trip Unit Serial Number 405241 ASCII R 4942
Type of trip unit 405083 U16-21 R 4957
CL1 Local Time 405163 DateTime3RW 23421
CL1 Universal Time 405163 DateTime3RW 23420
I Avg Demand 405016 U16-21 R 22659
I average mx 405018 U16-21 R 22757
I gnd fault mx 405020 U16-21 R 22756
I mx 405021 U16-21 R 22751
I neutral mx 405019 U16-21 R 22755
I Unbalance mx % 405017 U16-21 R 22758 0x00FF
I Demand mx 405022 U16-21 R 137363457

COM21-ETU Comm error coun 405069 U16-21 R 141558017

Breaker operations caused by a 405065 U16-21 R 23251

Number of short circuit trips 405061 U16-21 R 23256


Number of over current trips 405063 U16-21 R 23257

Number of ground fault trips 405064 U16-21 R 23258

Modbus Comm error counter 405068 U16-21 R 141557761


Operating hours 405066 U32-4321 R 23253
Breaker Position 405001 U16-21 R 65547 0x0003
Breaker Status 405001 U16-21 R 31542 0x000C
Breaker status Closed 405001 MaskedBooR 31559 0x0008
Breaker status Not ready 405001 MaskedBooR 31557 0x0000
Breaker status Opened 405001 MaskedBooR 31558 0x0004
Breaker status Tripped 405001 MaskedBooR 31560 0x000C 12
Ground fault trip status 405013 MaskedBooR 32131 0x0008
Instantaneous trip status 405013 MaskedBooR 32129 0x0002
Long Time Trip Status 405013 MaskedBooR 65548 0x0001
MODBUS Write enable 405167 U16-21 R 31549 0x00FF
Over current warning 405001 MaskedBooR 31546 0x0080 128
Short time trip status 405013 MaskedBooR 32130 0x0004
Thermal Trip Status 405013 MaskedBooR 65549 0x0080
Trip Current 405009 U16-21 R 31525
Trip Log 1 Time 405101 DateTime3R 32100
Trip Log 1 Reason 405105 U16-21 R 32101
Trip Log 2 Time 405107 DateTime3R 32102
Trip Log 2 Reason 405111 U16-21 R 32103
Trip Log 3 Time 405113 DateTime3R 32104
Trip Log 3 Reason 405117 U16-21 R 32105
Trip Log 4 Time 405119 DateTime3R 32106
Trip Log 4 Reason 405123 U16-21 R 32107
Trip Log 5 Time 405125 DateTime3R 32108
Trip Log 5 Reason 405129 U16-21 R 32109
Trip Phase Number 405010 U16-21 R 32116 0xFF00 256
Trip status 405001 U16-21 R 31551 0x7000
Trip unit mode 405001 U16-21 R 31550 0x0800
Trip unit status 405010 U16-21 R 65537 0x00FF
Write Protect 405001 U16-21 R 65542 0x0400
ZSI output status 405011 MaskedBooR 24630 0x1000
ZSI input status 405011 MaskedBooR 24631 0x2000
Neutral overload 405012 U16-21 R 32141 0x0400 1024
Neutral pre-alarm 405012 U16-21 R 32137 0x00FF
Overload Status 405012 U16-21 R 65540 0xFF00 256
Phase A overload 405012 U16-21 R 32138 0x0100 256
Phase A pre-alarm 405012 U16-21 R 32134 0x00FF
Phase B overload 405012 U16-21 R 32139 0x0200 512
Phase B pre-alarm 405012 U16-21 R 32135 0x00FF
Phase C overload 405012 U16-21 R 32140 0x0300 768
Phase C pre-alarm 405012 U16-21 R 32136 0x00FF
Pre-alarm Status 405012 U16-21 R 65541 0x00FF
Trip Unit Ground Fault 405008 MaskedBooR 65555 0x0040
Trip Unit Overload 405008 MaskedBooR 65551 0x0001
Trip Unit Overload Neutral 405008 MaskedBooR 65552 0x0002
ZSI gnd fault enable 405083 U16-21 R 24633 0x0001

Ground Fault Alarm Delay 405057 U16-21 RW 28989

Ground Fault Alarm Setpoint 405056 U16-21 RW 28965

Ground Fault Type 405054 MaskedBooRW 146800641 0x0100

Ground Fault Alarm Enable 405055 MaskedBooRW 146800642 0x0001


Baud Rate 405162 U16-21 RW 31111 0xFF00 256
Parity 405162 U16-21 RW 31112 0x00FF
Unit ID 405161 U16-21 RW 29191 0xFF00 256
COM21 is OK 405023 U16-21 R 23592 0xFF00 256
COM21-ETU Communication i 405023 U16-21 R 23595 0x00FF
COM21 Label 405201 ASCII RW 65546
I Neutral 405006 U16-21 R 22566
I ground Fault 405007 U16-21 R 24143
Ia 405002 U16-21 R 22536
I avg 405015 U16-21 R 22539
Ib 405003 U16-21 R 22537
Ic 405004 U16-21 R 22538
I Unbalance % 405017 U16-21 R 22565 0xFF00 256
Max current a,b,c 405005 U16-21 R 22563
Max current phase number 405014 U16-21 R 22562 0xFF00 256
30720
14000

Pre-alarm for over current 405053 U16-21 RW 16784

Pre-alarm over i enable 405052 MaskedBooRW 32318 0x0100

Continuous Current Rating 405041 U16-21 RW 65544

Instantaneous Enable 405055 MaskedBooRW 65545 0x0100

Delay time tg1 PSA 405048 U16-21 RW 29703

Delay time tsd PSA 405045 U16-21 RW 29697


Ground fault lg1 PSA 405047 U16-21 RW 29702

I-trip li (instantaneous) PSA 405043 U16-21 RW 29694

Ground Fault Delay Mode 405046 MaskedBooRW 29708 0x0001

Short Time Delay Mode 405046 MaskedBooRW 29698 0x0100

S-trip lsd (delayed short circui 405044 U16-21 RW 29696

S-trip lsd enable A 405052 MaskedBooRW 29699 0x0001

Thermal memory PSA 405051 MaskedBooRW 29692 0x0001

Time lag class tR PSA 405042 U16-21 RW 29688


26807
26808
Clear Trip Counters 405141 U16-21 W 176160769
MnMx Rset 405141 U16-21 W 176161025
Sync Time Stamp 405141 U16-21 W 176161281
Reset trips 405141 U16-21 W 176161537

Clear last trip in the trip unit 405142 U16-21 W 176161793

Clear all Trip Counters 405142 U16-21 W 176162049


ZSI Enable 405143 U16-21 RW 176162305

Set ZSI output (timeout 30sec) 405143 U16-21 W 176164097


Reset ZSI output 405143 U16-21 W 176164353
Multipli NumberOfReg
er EnumName isters

5
8

8
0.125

0.25

TripReason

TripReason

TripReason

TripReason

TripReason
32
1
1
1
1

1
1