Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of
small objects
This content has been downloaded from IOPscience. Please scroll down to see the full text.
(http://iopscience.iop.org/0031-9120/40/5/008)
View the table of contents for this issue, or go to the journal homepage for more
Download details:
IP Address: 137.99.26.43
This content was downloaded on 04/01/2014 at 15:34
Abstract
A little-known method of measuring the volume of small objects based on
Archimedes’ principle is described, which involves suspending an object in a
water-filled container placed on electronic scales. The suspension technique
is a variation on the hydrostatic weighing technique used for measuring
volume. The suspension method was compared with two other traditional
water displacement methods of measuring volume, i.e. placing an object in a
measuring cylinder and recording the rise in the water level and immersing
the object in a water-filled container with an overflow spout to record the
volume of overflow. The accuracy and precision of the three methods was
compared using ten accurately machined PVC cylinders ranging in volume
from 1.5 to 15.7 ml. The mean difference between the actual and measured
volumes was 3.3 ± 7.3%, −1.6 ± 7.2% and 0.03 ± 0.45%, for the level,
overflow and suspension methods respectively. Each measurement was
repeated twice to obtain the reproducibility of the three displacement
techniques. The reproducibility was −1.7 ± 8.5%, 0.09 ± 3% and
−0.04 ± 0.43% for the level, overflow and suspension techniques
respectively. The results show that the suspension technique is more
accurate and precise than the traditional water displacement methods and is
more accurate than measuring volume using Vernier calliper measurements.
education circles (i.e. in schools and universities). of a well-known make of electronic balance.
water
Figure 2. Schematic diagram of the suspension, level and overflow methods of measuring volume.
when the object is suspended in the fluid and V is exactly the same as if there were 110 g of water in
the unknown volume. the beaker and no suspended object.
At first sight this technique may seem to
present some difficulties. For example, some Materials and methods
questions that might be asked are: How can
The three volume-measuring techniques are
an object simply be suspended in water and the
summarized in figure 2. Ten accurately machined
change in weight translated directly into a volume? PVC cylinders ranging in volume between 1.5 and
How does the density affect the measurement? 15.7 ml were obtained (table 1). All cylinders
What about the variation in pressure around the were nominally 20 mm in diameter and 5, 10,
object? What about surface tension? 15, 20, 25, 30, 35, 40, 45, 50 mm respectively.
From a physics point of view, the analysis Vernier callipers accurate to ±0.02 mm were
of the situation is quite simple. We have an used to measure the cylinder dimensions more
object suspended in water that is stationary. If an precisely. The cylinder dimensions, volumes
object is stationary then we know that the forces and absolute and percentage errors are shown
on the object are balanced. In the case of an in table 1. A standard method was used to
object suspended in water at the end of a line, the calculate the error in calculating the volume from
downward force due to gravity (g) is balanced by the Vernier measurements (Kirkup 1994). The
the upward buoyancy (b) and tension (t) of the line volumes calculated from the Vernier dimensions
(figure 1). If the forces were not balanced then the were taken as the ‘gold standard’.
object would move. Therefore a stationary object A hole, approximately 0.35 mm in diameter,
suspended in water is equivalent to a volume of was drilled into the end of each PVC cylinder. A
water of exactly the same size and shape at the piece of 0.22 mm diameter monofilament fishing
same position as the object. We can take any line approximately 40 cm long was inserted into
arbitrary surface within a static volume of fluid each hole and attached with Super Glue Gel. A
and the surface integral of the force will be zero, felt-tipped ink pen was used to place a mark on
i.e. the forces are balanced. the line 5 mm above the surface of each cylinder.
As an example, consider a 10 cm3 object Each cylinder with line attached was
suspended in a beaker containing 100 ml of water. immersed to this point. A 150 ml polythene
When placed on the balance, the beaker of water beaker, approximately 55 mm in diameter, was
with the suspended object will weigh 110 g— filled with about 110 ml of water. This was enough
to allow suspension of the longest PVC cylinder. after placement of each PVC cylinder in the water.
The water temperature was measured with a Fluke The measuring cylinder was emptied and refilled
(www.fluke.com) electronic thermometer with an before inserting each PVC cylinder.
80PK-1 immersion probe. The stated accuracy A third method was used to measure the
and resolution of the thermometer are ±[0.2% + volume of each PVC cylinder, which involved
0.3 ◦ C] and 0.1 ◦ C respectively. Temperature placing the cylinders in a metal container with
measurements were made at various times during a downward-pointing spout. The container was
the course of the experiments. The water filled with water so that the level was just above
temperature was 23 ± 0.5 ◦ C. the bottom of the spout. Two minutes were
The beaker of water was placed on the allowed for the water to overflow through the spout
pan of a Mettler AE260 Analytical balance and drop down to the base level. A cylinder
(www.mt.com). This balance has a full-scale was then dropped into the container and the
range of 200 g and a precision of 1 mg. However, overflow water collected in a 60 ml polythene
the object on the balance can be ‘tared’ off so that cup. The cup was weighed using the same Mettler
the reading is set to zero. In this case, the balance balance described above. The container was
can read up to 60 g with a precision of 0.1 mg refilled between each volume measurement and
if the tared weight is less than 140 g (so that the the polythene cup emptied and dried. The volume
total weight does not exceed 200 g). Each PVC of each PVC cylinder was calculated by dividing
cylinder was suspended beneath the surface of the the weight of water collected by the density of
water and the weight recorded after a few seconds water at 23 ◦ C.
of stabilization. The volume of each cylinder was The precision of this method of measuring
calculated by dividing the measured weight by volume was assessed by measuring the average
the density of water at 23 ◦ C, which is given as volume of each drop. This technique cannot be
0.997 569 g ml−1 in the Handbook of Chemistry more precise than the volume of the individual
and Physics (1971). Each volume measurement drops. A total of ten drops were collected in the
was performed twice to determine reproducibility plastic cup and then weighed. This was repeated.
by the method of Bland and Altman (1986).
The volume of each cylinder was also
measured using a plastic 50 ml measuring
Bland–Altman analysis
cylinder with an internal diameter of 2.3 cm Bland–Altman analysis is the best way to compare
and a measuring accuracy of ±0.5 ml. The two techniques of measuring the same quantity.
position of the meniscus was recorded before and For example, we might have a new method of
after placement of each object in the measuring measuring a quantity and want to compare it to an
cylinder. Although the graduations on the cylinder existing method considered to be a gold standard.
were 1 ml apart, the level of the meniscus was A method often used is to plot a scattergram and
estimated to the nearest 0.1 ml. The volume was calculate the correlation coefficient. The closer
taken as the difference in the volume before and the correlation coefficient is to unity, the better the
Table 4. Reproducibility of the three methods of measuring volume. r 2 is the correlation coefficient.
Method Absolute error (ml) % error r2
Level 0.01 ± 0.2 −1.7 ± 8.5 0.9997
Overflow −0.02 ± 0.18 0.09 ± 3.0 0.9994
Suspension −0.007 ± 0.03 −0.04 ± 0.43 0.9998
(a) (a)
18 18
16 16
level level
volume difference (ml)
measured volume (ml)
14 overflow 14 overflow
down thrust down thrust
12 12
10 10
8 8
6 6
4 4
2 2
0 0
0 2 4 6 8 10 12 14 16 18 0 2 4 6 8 10 12 14 16 18
actual volume (ml) mean volume (ml)
(b) (b)
0.6 0.6
level (l)
level (l) o overflow (o) l
volume difference (ml)
–0.2 –0.2
–0.4 –0.4
–0.6 –0.6
0 2 4 6 8 10 12 14 16 18 20 0 2 4 6 8 10 12 14 16 18 20
mean volume (ml) mean volume (ml)
Figure 3. (a) Scatter plot of measured volume Figure 4. (a) Scatter plot of repeat measurements of
versus actual volume for the suspension, level and the level, overflow and suspension volumes.
overflow techniques. The line of identity is shown. (b) Bland–Altman plot of the data.
(b) Bland–Altman plots of the data showing the level
of agreement between measured and actual volumes.
The ‘error bars’ on the right-hand side indicate the
accuracy (middle bar) and precision (top and bottom In this case the volume of the cage would have to
bars) of the three techniques. 95% of the data are
expected to fall within ±1.96m. be measured accurately, for example by using the
suspension method described in this article.
A number of factors affect the overall
be possible. If a line cannot be attached, then accuracy of the technique, for example absorbed
some kind of stage or cage could be constructed to air bubbles, line surface tension, air currents, water
support the object beneath the surface of the water. absorption by the object, surface evaporation of