Shutdown SIS
Previous Screen
i04926839
Illustration 1 g03099577
(1) ARD combustion head
(2) ARD Nozzle Heater Wire
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sis... 2.2.2022 г.
D6T TRACK-TYPE TRACTOR XL, XW, LGP, Differential Steering MEL00001-UP... Page 2 of 2
Illustration 2 g03099598
Measuring the current flow
(1) ARD combustion head
(2) ARD Nozzle Heater Wire
(3) Clamp-on ammeter
2. Connect the clamp on 225-8266 Ammeter Tool Gp (3) around the ARD nozzle heater wire (2) on the
ARD combustion head (1). Make sure that the jaws of the ammeter are away from the metal part of
electrical connector . Refer to Systems Operation/Testing and Adjusting, "Charging System - Test"
for information about the ammeter.
3. Establish communication between Caterpillar Electronic Technician and the ECM. Refer to
Troubleshooting, "Electronic Service Tools" for the proper procedure.
4. Start the engine. Activate the "ARD Nozzle Heater Circuit Test" under the "Diagnostic Tests" menu
in Cat ET. The circuit test will run for 3 minutes and can be stopped at any time.
6. Disable the circuit test. Stop the engine. Remove the clamp-on ammeter.