ELECTRICAL WORKS

9700

4500 1875 3325


9700
9700
NOTE AND LEGENDS
4500 1875 3325 9700
4500 1875 3325
4500 5200

CONNECTION FOR
CONNECTION FOR
EXHAUST FAN
BREAKER @ 60 AMPHERE

125

200
EXHAUST FAN

125

125
25
CUT OUT MAIN SCWITCH

125
CONNECTION FOR

25
AC-S/O AC-S/O
EXHAUST FAN
S1
CONNECTION FOR S1
EXHAUST FAN
DS JB
JB WALL MOUNTED DOUBLE
DS DS
S1 OUTLET @ 1200 mm HEIGHT
4500

4500

4500
4500

4500

4500
DS
DS DS DS

4500

4500
FROM FLOOR LEVEL
S1
S1
S
DS DS WALL MOUNTED DOUBLE
DS JB
9000

OUTLET @ 400 mm HEIGHT

9000
9000
DS S1

9000
AC-S/O FROM FLOOR LEVEL
25 S1
S1

11000

11000
11000
11000
DS
JB DS
WALL MOUNTED
S
4500

4500

4500

4500

4500

4500
S1 SINGLE SWITCH

4500

4500
ST-01
ST-01
ST-01
UP
UP JB ST-02
UP
S1 S1 SINGLE SWITCH
DS WALL OUTLET
DS
DS
S1 S1
2000

2000

2000
2000
S1
WALL MOUNTED

2000
CONNECTION FOR
EXTERNAL LIGHTS
DS DOUBLE SWITCH

CONNECTION TO CONNECTION FOR


1st FLR BREAKER EXTERNAL LIGHTS
CABLE CONNECTION TO WALL MOUNTED AIRCON (A/C) SWITCH
THE PENTHOUSE FLOOR AC-S/O AND OUTLET @ 1600mm HEIGHT FROM
4500 5200 4500 5200 BREAKER

5200
1000 4500 5200 FINISH LEVEL

E. GROUND FLOOR CEILING LIGHTS LAYOUT PLAN E. GROUND FLOOR CEILING AIRCON CONNECTION LAYOUT PLAN E. FIRST FLOOR CEILING LIGHTS LAYOUT PLAN DECORATIVE CEILING
SCALE: 1:100 MTRS E. GROUND FLOOR WALL MOUNTED OUTLET LAYOUT PLAN SCALE: 1:100 MTRS SCALE: 1:100 MTRS LIGHT SANDELER
SCALE: 1:100 MTRS

RECESS CEILING
DECOR LIGHTS

CEILING JUNCTION BOX CONNECTION


9700
FOR THE CEILING LIGHTS FIXTURES
9700 4500 5200
9700
4500 5200 9700
4500 5200 WALL JUNCTION BOX CONNECTION
4500 5200 @ 400mm HEIGHT FROM FLOOR LEV.
125

125

125
EXTERNAL DECOR

595
S1
LIGHTS AT CANOPY
S1 S1

AC-S/O

1700
JB

4500

4500
JB
DECOR CEILING
4500

4500

4500

4500

3480
ROUND LIGHTS

4500

4500
S1
S1 S1 AC-S/O
CEILING JUNCTION BOX CONNECTION

1700
JB FOR THE AIRCON (A/C) FIXTURES

9000
S1
9000

650
525
9000

9000

11000
11000

11000
JB
WIRE CABLE HEAVY DUTY

11000
FROM BREAKER CONNECTED

4500

4500
TO THE CEILING JUNCTION
4500

4500

S1
4500

4500
BOXES FOR AIRCON SWITCH

4500

4500
4350
S1
AC-S/O

AC-S/O
S1 JB ST-02
AND OUTLET.
ST-02
ST-02 JB
S1 CONNECTION FROM FIRST FLOOR
DOUBLE SWITCH TO EXTERNAL
LIGHTSREFER 1F CEILING LIGHTS
WIRE CABLES HEAVY
CONNECTION FROM GROUND
S1 S1 FLOOR DOUBLE SWITCH TO
LAYOUT PLAN DUTY CONNECTION
S1 EXTERNAL LIGHTS REFER GF FROM POINT TO POINT

2000

2000
650
500
CEILING LIGHTS LAYOUT PLAN
2000

2000

2000

2000

2000
4700

2000
WIRE CABLE HEAVY DUTY
FROM BREAKER CONNECTED

525
150 TO THE CEILING JUNCTION
650 4550 BOXES FOR CEILING LIGHTS
1000 4500 5200 1000 4500 5200 CONNECTION
1050 4500 5200 1650 2850 5200
10700
E. FIRST FLOOR WALL MOUNTED OUTLET LAYOUT PLAN WIRE CABLE HEAVY DUTY
SCALE: 1:100 MTRS E. FIRST FLOOR CEILING AIRCON CONNECTION LAYOUT PLAN E. GROUND FLOOR CEILING CONC LEDGE CANOPY EXTERNAL LIGHT PLAN
SCALE: 1:100 MTRS E. FIRST FLOOR CEILING CONC LEDGE CANOPY EXTERNAL LIGHT PLAN FROM THE BREAKER MAIN
SCALE: 1:100 MTRS SWITCH CONNECTED TO WALL
SCALE: 1:100 MTRS
JUNCTION BOXES FOR WALL
DOUBLE OUTLETS
CONNECTIONS

WIRE CABLE HEAVY DUTY


FROM THE JUNCTION BOX
5200 CONNECTED TO THE WALL
5200 5200 MOUNTED AIRCON SWITCH
1425 3875 1325
AND AIRCON OUTLETS
1425 1400 2475 1325 1425 1400 2475 1325
CONNECTION
EXHAUST FAN
WIRE CABLE HEAVY DUTY
FROM THE MAIN SWITCH
BREAKER TO BREAKERS
FOR CONNECTIONS
3025

AC-S/O
S1

3025
S1

3025
S1
4500

4500

JB
4500

DS

4500
4500

DS DS
WIRE CABLE HEAVY DUTY
6300
6875

AC-S/O FROM CEILING JUNCTION

6300
S1 S1

6300
CONNECTION FROM PENTHOUSE
FLOOR DOUBLE SWITCH TO BOXES CONNECTED TO WALL
EXTERNAL LIGHTS REFER S1
PENTHOUSE CEILING LIGHTS
MOUNTED SWITCHES FOR
DS S1 S1
THE CONNECTIONS
3275

LAYOUT PLAN JB
DS S1

3275
3275
1800
2375

2375

CONNECTION

1800
EXHAUST FAN
1800

DS DS
AC-S/O
CABLE CONNECTION FROM S1
FIRST FLOOR BREAKER TO CONNECTION FOR
PENTHOUSE FLOOR
BREAKER
EXTERNAL LIGHTS
NOTES:
2000 5200
1425 3875 1325 1425 3875 1325
ELECTRICAL INSTALLATION SHALL
BE ADJUSTED AND TO BE MODIFIED
E. PENTHOUSE FLOOR WALL E. PENTHOUSE FLOOR CEILING DURING CONSTRUCTION IF FOUND
E. PENTHOUSE FLOOR CEILING
E. PENTHOUSE FLOOR CEILING LIGHTS LAYOUT PLAN MOUNTED OUTLET LAYOUT PLAN AIRCON CONNECTION LAYOUT PLAN CONFLICT TO OTHER FIXTURES AS
CONCRETE LEDGE CANOPY EXTERNAL LIGHTS PLAN SCALE: 1:10 M
SCALE: 1:100 MTRS SCALE: 1:100M
SCALE: 1:100 M WELL THE INSTALLATION OF POINTS
AND LIGHTINGS & BOXES & OTHERS.

PROJECT TITLE : CLIENT: SHEET CONTENTS : DESIGNED BY : K2A_CE SHEET NO. 10


ENGR. KEMAL A. ANDALAN CHECKED BY : K2A_CE
ELECTRICAL MIRALAM U. TILLAH
REG. NO.
ELECTRICAL
TIN.
PLACE :
KEMAL A. ANDALAN

REG. NO. PRC # 0066139


ENGINEER
PTR.
PROPOSED 2 - STOREY HOUSE + PENTHOUSE OWNER
K2A ELECTRICAL CONNECTIONS AND LAYOUT PLAN, FOR GROUND
FLOOR, FIRST FLOOR, ROOF FLOOR AND PENTHOUSE FLOOR
CAD BY : K2A_CE
MEP R-0
PTR. DATE : DATE :
ZAMBOANGA CITY, PHILIPPINES ZAMBOANGA CITY, PHILIPPINES
DATE : 30/SEPT/2015 PROJECT NO. B050667
IAPOA NO. TIN. PLACE :