JOWA SILVER STERILIZER

JOWA Ag-Sterilizer
TIMER

OPERATING INSTRUCTIONS AND


TECHNICAL MANUAL
Date: 2018-03-08 JOWA Ag-Sterilizer
Rev: E Silver Ion Sterilizer
Sign: BR Standard

Table of Contents

1.0 Introduction ............................................................................................ 2


1.1 General.............................................................................................................. 4
2.0 Technical Specification ......................................................................... 5
3.0 Disinfection of Water Onboard ............................................................. 6
3.1 Standard Installation ........................................................................................ 6
3.2 Optional extras.................................................................................................. 7
4.0 Installation.............................................................................................. 8
4.1 Mounting .......................................................................................................... 8
4.2 Piping Connections ........................................................................................... 8
4.3 Electrical Connections ...................................................................................... 9
4.4 Normal connections (flow diagram 31-0000-03-01 electrical 31-0100-02-02) 9
5.0 Operation.............................................................................................. 10
5.1 Start Up ........................................................................................................... 10
5.2 Operating the Menu System ........................................................................... 10
5.3 Operating Modes. ........................................................................................... 10
5.4 The Menu System Display Tree ................................................................. 12
5.4.1 Menu Tree Page Descriptions ................................................................. 13
5.5 Alarm List ....................................................................................................... 17
5.6 Replacement of the Electrode Unit ................................................................. 18
5.7 Maintenance.................................................................................................... 18
7.0 Spare Parts List ................................................................................... 21
8.0 Flow Diagram ....................................................................................... 22
9.0 Mechanical Drawings .......................................................................... 23
10.0 Electrical Drawings ............................................................................. 24
11.0 Approval Certificates ........................................................................... 25

K:\1-NYA K\1-JOWA PRODUKTER\AGS\Nya Ags\Manual 1/25


Date: 2018-03-08 JOWA Ag-Sterilizer
Rev: E Silver Ion Sterilizer
Sign: BR Standard

1.0 Introduction

There are many ways of sterilise water, both long term


and short term. In this manual we will try to explain how
our silver sterilising system works. The JOWA Ag-s is a
long term system used for storage tanks where the water
is kept for a period of time. After a contact time of 4 hours
the silver ions eliminate the bacteria and prevents re-
growth.

The JOWA Ag-S Silver Sterilizer is a well-known product in the shipping world.
Since its introduction 1970 several thousands of ships have had it installed
onboard. Sterilisation is achieved by dosing silver ions, so called oligodynamical
sterilisation into the medium. The silver ions are released by electrolysis from
two silver plates by connecting the special silver electrode unit to small current
(DC).

The Jowa Ag-S electrode unit consists of two high purity (99,99%) silver plates.
The medium passes through the centre of the electrode and between the two
silver plates. The released silver ions, following the current direction between
the plates, are forced by the media to flow out of the electrode chamber and
into the pipe system. By changing the current direction once every ten minutes
where by the anode and the cathode change place, silver ions will be released

K:\1-NYA K\1-JOWA PRODUKTER\AGS\Nya Ags\Manual 2/25


Date: 2018-03-08 JOWA Ag-Sterilizer
Rev: E Silver Ion Sterilizer
Sign: BR Standard

evenly from both plates over a period of time. The periodical change of the
current also keeps the plates clean eliminating the otherwise necessary regular
cleaning procedure.

Sterilizing drinking water using silver is a very old method and has been used
frequently in many parts of the world since antiquity. Before introduction of
penicillin the silver was used in many medical products and where proved to be
effective. Today silver are used to prevent salmonella in many onshore
installations.

The concentration can be either A: 0,04 mg/l or B: 0,10 mg/l silver depending
on the ruling maritime administration.

The dose level (A or B), operation mode (auto/manual) and system status
(run/stop) is indicated by the display on the front of the control panel. The pre-
set current load is automatically maintained by the electronic control panel. This
prevents incorrect dosing. An alarm is raised when the electrode is consumed
(current does not reach the pre-set value).

An audible/visible alarm can also be fitted in the main control room to indicate
any malfunction of the unit (e.g. low flow of water, exhaustion of the anodes).

The user should measure the silver ions concentration annually. Samples
should be taken from the outlet of the storage tank(s) and at the extremity of
the system.

Care must be exercised over the collection and storage of the samples and it is
strongly recommended that the advice of a competent laboratory is sought and
followed.

Normally such a laboratory will supply full instruction and sterilised bottles.

Alternatively the concentration may be checked on a regular basis using on


board testing equipment.

The Administration should be advised of any low concentrations.

K:\1-NYA K\1-JOWA PRODUKTER\AGS\Nya Ags\Manual 3/25


Date: 2018-03-08 JOWA Ag-Sterilizer
Rev: E Silver Ion Sterilizer
Sign: BR Standard

1.1 General

To obtain all the advantages from operating a JOWA Ag-Sterilizer ensure that
all users have adequate education for the equipment, ensure that the
installation is correct and ensure that the Ag-Sterilizer is maintained and
operated in accordance with the instructions in this manual. The correct
function of the equipment cannot be guaranteed if the user fails to follow these
instructions.

Before installation and start-up read this manual carefully.

Supplier and manufacturer: JOWA AB


Tulebo 865
S-428 34 Kållered , Göteborg
Sweden
Phone: +46-31 726 54 00
Fax: +46-31 795 45 40
Email: info@jowa.se
www.jowa.se

K:\1-NYA K\1-JOWA PRODUKTER\AGS\Nya Ags\Manual 4/25


Date: 2018-03-08 JOWA Ag-Sterilizer
Rev: E Silver Ion Sterilizer
Sign: BR Standard

2.0 Technical Specification

Type Value
3
Capacity: A: 0,04mg/L 0,5-15,0m /h
3
Capacity: B: 0,10mg/L 0,5-6,5m /h
Silver Dosage 0.04 & 0.10mg/L
Current Range 0-200mA
Electrode Specification JOWA Standard 2 x 2mm, 280g Ag
Life span at 0.04mg
3
7000m
Life span at 0.10mg
3
2800m
Voltage 115/230 VAC 50/60Hz
Power Consumption <30W
Alarm Relay output, normally open/closed
1A resistive max 230VAC
Dimensions Unit See Mechanical Drawings Chapter 9
Chamber Test Pressure 9 bar
Dimension inlet & outlet DN 15 Female Thread
Empty Weight 9,5kg
Chamber Material AISI 316L
Flow Transmitter (optional) Pulse Type, pulse/L adjustable
Operating Temperature 5-60 degrees Celsius
IP Class 54
Colour RAL 7035 (control cabinet)

K:\1-NYA K\1-JOWA PRODUKTER\AGS\Nya Ags\Manual 5/25


Date: 2018-03-08 JOWA Ag-Sterilizer
Rev: E Silver Ion Sterilizer
Sign: BR Standard

3.0 Disinfection of Water Onboard

3.1 Standard Installation

Read this section in Conjunction with drawing 31-0000-03-01, flow diagram.

• Flow switch FS01


• Valve V01
• Branch line

Fig 3.1

Standard Installation’ for the Ag-S system is a vessel with a water supply
system that incorporates bunkered water and water from production plants
(either reverse osmosis and evaporation plants)

The sterilizer is installed after the pressure vessel (hydrophore tank) in a branch
line from the main water supply line. Pressure for the sterilizer is provided by
the hydrophore pump.

The sterilizer unit doses silver into the branch line. This branch line is then
directed back to the ships storage tank where the silver dose can sterilizer the
entire ships fresh water supply. See fig 3.1

The silver concentration in this branch line from the Ag-s to the storage tank is
very high. When this water comes in contact with the “newly made water” in the
storage tank the concentration will be right.

The silver must be allowed a minimum 4 hours contact time with the water in
the fresh water storage tank to have full sterilizing effect.

K:\1-NYA K\1-JOWA PRODUKTER\AGS\Nya Ags\Manual 6/25


Date: 2018-03-08 JOWA Ag-Sterilizer
Rev: E Silver Ion Sterilizer
Sign: BR Standard

The valve V01 is controlled by the Ag-s and will open when the unit starts. The
water will then go through the silver chamber at the bottom and out at the top.
The flow switch FS01 will tell the system if there is a flow going through the
chamber (20 sec. Delayed).

The Ag-s unit can be controlled by remote signal. A signal from water maker
starts the Ag-s and a the Ag-s can send a signal to Water maker to stop if the
Ag-s unit stops.

The system is supplied with a timer mode to

• compensate for flow rates outside the sterilizers capacity when


bunkering water from shore
• compensate for losses of silver ions over time by periodically running
and “topping-up” the silver ion concentration.

3.2 Optional extras

The system is easily modified for non-standard special installations. JOWA AB


will give you support when you have special installation requirements.

The installation can incorporate a flow transmitter as an optional extra installed


in the water production plant line. The silver sterilizers microprocessor will
determine the correct dose of silver based on the flow signal from the
transmitter. NOTE! A flow transmitter is required if the unit is to be run in
AUTO MODE

As an extra protection a shut off valve V02 can be installed on the main pipe, to
stop the water flow from water maker. This is to avoid any non sterilised water
being produced. In this case there should also be a stop signal connected from
the Ag-s to the water maker.

K:\1-NYA K\1-JOWA PRODUKTER\AGS\Nya Ags\Manual 7/25


Date: 2018-03-08 JOWA Ag-Sterilizer
Rev: E Silver Ion Sterilizer
Sign: BR Standard

4.0 Installation

4.1 Mounting

The Jowa Ag-S sterilising unit consists of a standard cabinet with all the
electronics, a sterilising electrode chamber made in high grade electro-polished
stainless steel, one shut off valve, flow setting valve, flow switch and pressure
meter.

Additional parts (optional),

Shut off valve for bunker line


Shut off valve for production line (water maker).
Flow Transmitter for production line

All parts are mounted on a common polished stainless steel plate ready to be
installed on a bulkhead. (Flow switch FS01 and the valve V01 is loose supply.)

The unit has passed a work-shop test before delivery.

4.2 Piping Connections

The sterilising unit is to be connected to 15 mm pipes on the water inlet and on


the water outlet of the electrode chamber.

K:\1-NYA K\1-JOWA PRODUKTER\AGS\Nya Ags\Manual 8/25


Date: 2018-03-08 JOWA Ag-Sterilizer
Rev: E Silver Ion Sterilizer
Sign: BR Standard

4.3 Electrical Connections

The sterilizer is designed to be connected either to 115 or 230 VAC, 50/60 Hz.
Terminal

J1 Flat cable CPU <-> Interface board


J2 (1,2) Power supply input 115/230 VAC 50/60 Hz
J3 (1,2) Power supply input for valve
J4 (1,2) Relay output for solenoid valve
J5 (NO,C,NC) Spare. Not in use
J6 (1,2) Power supply input (for J7 if needed)
J7 (1,2) Run. signal
J8 (NC,C,NO) Relay output for external alarm "internal failure"
J9 (1,2) Electrode
J10 (1,2) Flow transmitter (pulse)
J11 (1,2) Flow switch
J12 (1,2) Spare. Not in use
J13 (1,2) Remote start

4.4 Normal connections (flow diagram 31-0000-03-01 electrical 31-0100-02-02)

1. Power input on terminal J2


2. Solenoid valve V01 on terminal J4
3. Run. Signal to water maker J6-J7. (Telling water maker that Ag-s is
running/stopping.)
4. External alarm J8
5. Electrode J9
6. Flow switch J11
7. Remote start from water maker J13

K:\1-NYA K\1-JOWA PRODUKTER\AGS\Nya Ags\Manual 9/25


Date: 2018-03-08 JOWA Ag-Sterilizer
Rev: E Silver Ion Sterilizer
Sign: BR Standard

5.0 Operation.

5.1 Start Up

• Open inlet and outlet valves. Check for leaks.


• Check that the green (LED) lamp "Power" is shining
• The manual flow is factory set to 2.0 m3/h and the silver dosage is set to
A(0.04mg/l). The flow is the flow of “new water” from water maker/bunker
ready to be sterilised. In case the user wants to change manual flow or silver
dosage he has to change the settings set in the Settings Menu.
• To start the sterilize press YES at the start page.
• Check that solenoid valve opens when the YES button is pressed.
• Adjust the flow by adjusting the flow setting valve (approx. 3­5 l/m).

Note! It is important that the set value corresponds to the actual flow from
water maker or bunker, so for safety, check the flow regularly.

5.2 Operating the Menu System

When the power is turned on, the application program of the Ag-S is started.
On the display the menu system is started. The menu system consists of a
number of screens – settings, silver consumption, JOWA contact information,
status and operation mode.

You navigate in the menu system by pressing the button – UP, DOWN, YES
and NO.

5.3 Operating Modes.

MANUAL MODE - the current is set according to manual flow parameter called
ManFlow and silver dosage parameter called Dose. ManFlow is set in m3/h and
Dose is set to A or B. A corresponds to a silver dosage of 0.04 mg/l and B
corresponds to 0.10 mg/l. The “ManFlow” is the main flow from water maker or
bunker. In this mode the Ag-s can be started from the water maker via a signal
to terminal J13 (remote start) in Ag-s control box (open contact = stop and
closed contact = start).

K:\1-NYA K\1-JOWA PRODUKTER\AGS\Nya Ags\Manual 10/25


Date: 2018-03-08 JOWA Ag-Sterilizer
Rev: E Silver Ion Sterilizer
Sign: BR Standard

AUTO MODE – the current is set according to the flow meter parameter called
FlowMet (litres/pulse). This parameter has to be set before the user can enable
the AUTO mode. Auto mode is controlled by a flow transmitter on water maker
line (flow transmitter optional supply).

Note: In auto mode the operator should press “yes” to start the sterilizer.

When started in auto mode the silver dose will be regulated by the pulses from
flow transmitter.

TIMER MODE –

The Ag-s can be run and paused by setting timers under the ‘settings’ menu in
manual mode

• First set the flow rate “ManFlow” in m3/h

Setting the run and pause timers, e.g. runtime is set to 30min & pausetime to 2
days, means the AG´s run for 30 min every second day

• The timer for run is “TimMa ()” and is set in minutes


Set the minutes and the timer appears in display as “TimMa(S)” [indicating that
timer is set]
Press “yes” again and the timer appears in display as “TimMa(SE)” [indicating
that timer is set and enabled]

• The timer for pause Is “TimLo ()” and is set in days


Set the number of days and the timer appears in display as “TimLo(E)”

• Return to the top menu and start the Ag-S. the display shows a count-
down in minutes indicating the value input for run time. After the timer
runs out the unit pauses according to the time set in “TimLo”

*Calculation example when the flow-rate for bunkering exceeds the AgS
capacity:

Say the amount bunkered is out of range of the Ag-S; i.e.>15m³/h.


In this case use timer mode to make-up the concentration

For example if you bunker 30m³ of water :


• you set “ManFlow” to 15m³/h (dose A)
• Then set run timer for 120 minutes. [30 /15 = 2hours]
• Set pause timer for say 1 day
• The Ag-S stops after the run time counts out and now the concentration
of silver ions in the storage tank is made-up to correct dose (for dose A)

K:\1-NYA K\1-JOWA PRODUKTER\AGS\Nya Ags\Manual 11/25


Date: 2018-03-08 JOWA Ag-Sterilizer
Rev: E Silver Ion Sterilizer
Sign: BR Standard

5.4 The Menu System Display Tree

In the menu system there are several screens telling the user about its status.
In case of an error there are a number of error messages that will pop up on the
LCD.

In the figure below you can see the different screens pages of the menu
system.

K:\1-NYA K\1-JOWA PRODUKTER\AGS\Nya Ags\Manual 12/25


Date: 2018-03-08 JOWA Ag-Sterilizer
Rev: E Silver Ion Sterilizer
Sign: BR Standard

5.4.1 Menu Tree Page Descriptions

Page 1 – Mode and Current Load Setting

YES for start/stop!


Dose: A: 0.04 mg/l B: 0.10 mg/l
Mode: MANUAL/AUTO [flow]
STOPPED

This is the first page displayed after start up.


To start please press the YES button and the fourth line will be replaced by:

...STARTED-MANUAL...

Or start by remote signal (J13)


...STARTED-REMOTE...

Option,
If started with the timer (short time) remaining time of the run. time will be
displayed.

HH:MM:SS

Next menu arrow up,


This is the page showing information about the status of the AG-Sterilizer. If
you browse among the other setting pages and press NO you will return to this
page.

Page 2 – Silver Consumption


Ag amount consumed
Ag g: X [X %]
Alarm at 80 %
Press YES to reset!

This page shows the amount of silver consumed. It also calculates the
percentage and the current alarm level. When YES is pressed you will be
transferred to a page where you can clear the silver consumption. If YES is
pressed at this page the silver consumption will be set to zero again.

Replaced electrode?
Reset counter
when replaced
YES=Ok NO=Cancel

K:\1-NYA K\1-JOWA PRODUKTER\AGS\Nya Ags\Manual 13/25


Date: 2018-03-08 JOWA Ag-Sterilizer
Rev: E Silver Ion Sterilizer
Sign: BR Standard

Page 3 – JOWA Information


JOWA AB
Gothenburg, Sweden
+46-31 726 54 00
www.jowa.se

Page 4 – Sub Menu for Settings

YES for Settings

Press YES to get to a sub menu where you can change settings.

Settings – Sub menu

To be able to change settings you have to press YES at each page. The current
value is displayed on the LCD. Next to this, the value which will be replaced by
your setting. The setting is performed by pressing the buttons UP/DOWN on
the overlay. To confirm the setting please press YES, and to cancel the
operation press NO.

Page 1 – Setting Page


>Mode: MANUAL/AUTO
Settings
Status
Language: ENG

The first row shows the actual operation mode (manual or auto). If the user tries
to change to AUTO mode and the flow meter parameter is not set, the user will
be transferred to the settings page for AUTO mode.

K:\1-NYA K\1-JOWA PRODUKTER\AGS\Nya Ags\Manual 14/25


Date: 2018-03-08 JOWA Ag-Sterilizer
Rev: E Silver Ion Sterilizer
Sign: BR Standard

Fig 5.0 Current Load Setting Diagram:

• Set the flow according to the performance of the water maker.


• The “flow set” will adjust the current to a value so that the amount of silver
(mg/l) released into the water is following the ruling authority.
• Select alternative:
Alternative A 0,04 mg/l (12 mA/m 3 /h. Select curve A in diagram) limit
0,5-15 m³/h.
3
Alternative B 0,10 mg/l (30 mA/m /h Select curve B in diagram) limit
0,5-6,5 m³/h.

K:\1-NYA K\1-JOWA PRODUKTER\AGS\Nya Ags\Manual 15/25


Date: 2018-03-08 JOWA Ag-Sterilizer
Rev: E Silver Ion Sterilizer
Sign: BR Standard

Page 2 – Settings Page for Manual Mode (See Fig 5.0, previous page)
>Dose: A
ManFlow:XX.X [m3/h]
TimMa(ES): XXX [m]
TimLo(E): XX [d]

Dose: A or B. A = 0.04 mg/l or B = 0.10 mg/l.


ManFlow (Manual Flow): 0.5 – 15.0 m3/h.
(Option)
TimMa: 1-… Number of minutes for the ”short time” timer (running time).
TimLo: The number of days between two different runs. The resolution for this
timer is 1 to 14 days.
e.g. runtime ( TimMa ) is set to 30min & pausetime ( TimLo ) to 2 days, means
the AG´s run for 30 min every second day

Page 3 – Settings Page for AUTO Mode


>Dose: A
FlowMet: XX.X [l/p]

Dose: A or B. A = 0.04 mg/l or B = 0.10 mg/l.


FlowMet (Flow Meter): The scale for the flow meter. Measured in litres per
pulse.

Page 4 – Status Information


Status
Signals: ABCDEFGH
Rev: X.X S: XXX-XXXX
Analog: I J

A = Flow Switch (IN) B = Pulse Input Flow Meter (IN)


C = Remote Start (IN) D = Current Direction (UT)
E = Alarm ON (UT) F = Control Sig. Alarm Relay (OUT)
G = Control Sign. run. Ind. (OUT) H = Solenoid valve V01 (OUT)
I = Current [mA] (IN - Analog) J = Control Signal Current Electrode Ag
(OUT - Analog), 0 – Maximum value of OCR-register
Rev = Revision Number of the Application Program
S = Serial number for the module.

K:\1-NYA K\1-JOWA PRODUKTER\AGS\Nya Ags\Manual 16/25


Date: 2018-03-08 JOWA Ag-Sterilizer
Rev: E Silver Ion Sterilizer
Sign: BR Standard

5.5 Alarm List

When running the AG-Sterilizer a number of errors can occur. The alarms are
specified below.

Silver Consumption
When 80 % of the silver has been consumed this alarm is generated. The red
LED on the overlay flashes, while the following message is displayed on the
LCD.

80% of Ag consumed
Order +46-31 7265400
Part # 30002-24209
Press YES to clear!

When YES is pressed the message disappears and the menu system returns to
the first page. If the user has not replaced the electrode and reset the counter
(see Page 2 – Silver Consumption), the program will give an alarm again at 85
%, 90 %, 95 % and so on. Finally the current becomes too low and another
error message will be generated (See below).

Flow Switch
If the flow switch signals is missing for 20 seconds this alarm is generated.
When the alarm occurs the current is set to zero, the solenoid valve is closed.
The common alarm is activated and the ALARM LED is lit. At the same time the
following message is displayed.

Flow failure
Check flow switch
and flow
Press YES to clear!

When the user has cleared the message the AG-Sterilizer is still turned off and
a new start signal has to be set before the AG-Sterilizer starts again.

Current Level
If the current level is too low for one minute this alarm is generated. This alarm
may have different causes. For example, the water may have too low
conductivity or the silver electrode is completely consumed and has to be
replaced. When the alarm occurs the current is set to zero, the solenoid valve is
closed, common alarm is activated and the ALARM LED is lit.

Current failure
Replace electrode or
too low conductivity
Press YES to clear!

K:\1-NYA K\1-JOWA PRODUKTER\AGS\Nya Ags\Manual 17/25


Date: 2018-03-08 JOWA Ag-Sterilizer
Rev: E Silver Ion Sterilizer
Sign: BR Standard

Low Flow
This alarm is generated when the total flow through the main pipe is below 0.5
m3/h in AUTO mode. The following message is shown and if the flow does not
exceed 0.5 m3/h for a minute the AG-Sterilizer is stopped.

Low flow limit


Check flow
Press YES to clear!

5.6 Replacement of the Electrode Unit

When the red (LED) lamp "Alarm" is shining and the alarm message ‘low
current’ is been shown the silver electrode must be replaced.

It is also important to know that the conductivity in the water can be too low to
be able to maintain the desired current (this will also generate this alarm).
Note: To avoid this you can install a JOWA re-hardening filter after water
maker. See flow diagram 31-0000-03-01

• Stop the flow by closing inlet and outlet valves


• Remove the electric plug from the electrode chamber
• Unscrew and lift out the electrode unit
• Check that the chamber is clean and free from foreign objects
• If necessary clean the chamber
• Put the new electrode unit in place an turn tight
• Put back the electric plug
• Open the inlet and outlet valves and check for leaks.
• Press "YES". The red (LED) lamp "Alarm" will cease to shine.
• Check that the green (LED) lamp "Power" is shining.
• Reset Silver Consumption and Counter, See Section 5.4.1

The sterilizer is now ready for operation.

5.7 Maintenance

Very little maintenance is required as high quality material is used. The


electrode chamber as well as the common base plate are made in polished
stainless steel and need no maintenance.

As the Jowa Ag-S Sterilizer uses pure silver in both of the electrodes and also
shifts the current direction once every ten minutes so there is no oxidation or
growth on the surface of the electrodes and no regular cleaning maintenance is
required.

K:\1-NYA K\1-JOWA PRODUKTER\AGS\Nya Ags\Manual 18/25


Date: 2018-03-08 JOWA Ag-Sterilizer
Rev: E Silver Ion Sterilizer
Sign: BR Standard

6.0 Trouble Shooting

Problem Cause Correction

Check the power


Green (LED) lamp "Power" No power to the sterilizer.
not shining The fuses defective
Replace fuses

Check the water flow from


water maker (must be over
Red (LED) lamp "Alarm" is 0,5 m³/h)
Low flow in the main pipe
shining and the following
< 0,5 m³/h
message is displayed: “Low Check the Flow transmitter
flow limit” (only in auto mode (signal can be checked in
Defective flow transmitter
and with flow transmitter) the Status page)

Press YES to clear!”

Replace electrode in the


chamber.
Red (LED) lamp "Alarm" is
shining and the following Low water flow in the
Check the Flow Switch
message is displayed “Flow chamber.
signal on the Status page.
failure, Check flow switch
and flow, Press YES to No water in the chamber.
Check the Flow Meter signal
clear!”
on the Status page.
Defective flow switch
Press YES to clear!”

The silver electrode are used


Red (LED) lamp "Alarm" is Replace silver electrode.
up.
shining and the following
Too low conductivity,
message is displayed: Use a filter to add minerals
The conductivity of the water
“Current failure, to the water.
is too low.
Press YES to clear!”

K:\1-NYA K\1-JOWA PRODUKTER\AGS\Nya Ags\Manual 19/25


Date: 2018-03-08 JOWA Ag-Sterilizer
Rev: E Silver Ion Sterilizer
Sign: BR Standard

Problem Cause Correction


Check signal from water
There is no signal from water
maker. (signal can be
The Ag-s cannot be started maker.
checked in the Status page)
remotely The signal are not connected
Check connection J13
to the right terminal
(closed contact should start
the Ag-s remotely)
R1 is burned on interface Defective silver electrode
Replace interface board and
board “short cut”
silver electrode
There is no pulses coming
Check pulses from
from flow transmitter
Ag-s is not recognising the transmitter. (signal can be
The pulses are not
pulses from flow transmitter. checked in the Status page)
selected/adjusted in the
See 5.3 Auto mode
menu

K:\1-NYA K\1-JOWA PRODUKTER\AGS\Nya Ags\Manual 20/25


Date: 2018-03-08 JOWA Ag-Sterilizer
Rev: E Silver Ion Sterilizer
Sign: BR Standard

7.0 Spare Parts List

Item no Description

30002-24209 *Silver electrode 2mm (std)

30008-00002 Flow switch DN10 3-4,5 l/min

32152-00016 Flow regulator DN15 2-8 L/min

33026-00002 Connection plug female

10108-00002 Pressure Gauge

19000-00087 CPU Card

30000-00085 Display Panel

30000-00086 Interface Card

94007-52010 Fuses 5x20 1AT

*Silver electrode is a consumable, consumption depends on runtime


and water volume to be treated.

Send your order for JOWA AG-S Spare Parts to

JOWA AB
Tulebo 865
S-428 34 KÅLLERED
SWEDEN
TEL:+46-31 726 54 00
info@jowa.se
FAX:+46-31 795 45 40
www.jowa.se
e-mail:

K:\1-NYA K\1-JOWA PRODUKTER\AGS\Nya Ags\Manual 21/25


Date: 2018-03-08 JOWA Ag-Sterilizer
Rev: E Silver Ion Sterilizer
Sign: BR Standard

8.0 Flow Diagram

K:\1-NYA K\1-JOWA PRODUKTER\AGS\Nya Ags\Manual 22/25


Date: 2005-02-16 JOWA Ag-Sterilizer
Rev: A Silver Ion Sterilizer
Sign: GS Standard

9.0 Mechanical Drawings

K:\1-NYA K\1-JOWA PRODUKTER\AGS\Nya Ags\Manual 23/25


6 5 4 3 2 1
430
1
2

D D
4

95
8

Outlet
3/8" Female
thread
547
460
430

6
C 7 C

3
A
5

38
59 7
130

460 8 1 Flow Switch DN10 Brass 0,149 kg 30008-00002


B B
7 2 Ball Valve DN15 Brass 0,182 kg 19001-15156
Inlet
6 1 Pressure Gauge 0-10 Bar Brass 0,429 kg 10108-00002
1/2" Female thread
20

5 1 Flow Regulator Brass 0,185 kg 32152-00016


4 1 Silver Electrode Assembly 0,175 kg 30002-24209
3 1 Ag-S Chamber AISI316L 0,618 kg 30-0090-01-01
2 1 Electrical Cabinet Ag-S S235 3,200 kg 31-0099-01-01
152

1 1 Ag-S Mounting Plate AISI316L 2,947 kg 30-0090-01-10


A (1:2) ITE QT DESCRIPTION MTRL MASS ID NUMBER
n10(x4) FILE NAME SIZE MODEL ID SCALE
31-0000-01-01 - Ag Sterilizer.iam A3 31-0000-01-01 1:4
DRAWN 2005-02-15 Greg
CHECK JOWA AB
TULEBO 865
15

A APPR.
Göteborg-SWEDEN
A
REV #1 080107 ES Teleph. +46 31 795 00 40
15 APPROVAL DRAWING
Dry Mass: approx 10kg
Service & Repair zone: 500mm around unit Ag-STERILIZER ID NO

JOWA SILVER STERILIZERS 31-0000-01-01


6 5 4 3 2 1
Date: 2005-02-16 JOWA Ag-Sterilizer
Rev: A Silver Ion Sterilizer
Sign: GS Standard

10.0 Electrical Drawings

K:\1-NYA K\1-JOWA PRODUKTER\AGS\Nya Ags\Manual 24/25


Ite m d e s . D e s ig n a tio n M a n u fa c tu r e Type JOW A N o: Sheet
E01 C O N TR O L P A N E L NP P 2 3 0 x3 0 0 x1 3 0 1 9 1 2 3 -3 7 3 0 1 01
A2 IN T E R F A C E B O A R D JO W A A g -s 3 0 0 0 0 -0 0 0 8 6 02
F 1 (A 2 ) FUSE C A R T R ID G E F . G L A S S 5 x2 0 T 1 A 2 5 0 V A C 9 4 0 0 7 -5 2 0 1 0 01
A3 C P U /D IS P L A Y B O A R D JO W A A g -s 1 9 0 0 0 -0 0 0 8 7 02
A 3 :1 D IS P L A Y JO W A A g -s 1 9 0 0 0 -0 0 0 8 5 01
S1 M A IN S W IT C H K R A U S & N A IM E R K F 1 6 T 2 0 3 /S -A 7 1 3 E 6 2 7 1 3 -1 0 0 1 6 02
X 1 , L 1 ,L 1 ,L 2 T E R M IN A L W E ID M U L L E R P D U 2 ,5 /4 9 9 1 2 9 -2 0 1 1 0 02
X 1 , 3 -5 T E R M IN A L W E ID M U L L E R P D U 2 ,5 /4 9 9 1 2 9 -2 0 1 1 0 02
X 1 , P E (5 p c ) T E R M IN A L W E ID M U L L E R P P E 2 ,5 /4 9 9 1 2 9 -2 0 1 2 4 02
Date: 2005-02-16 JOWA Ag-Sterilizer
Rev: A Silver Ion Sterilizer
Sign: GS Standard

11.0 Approval Certificates

K:\1-NYA K\1-JOWA PRODUKTER\AGS\Nya Ags\Manual 25/25