You are on page 1of 2

G-BH 1 N

Data sheet 2BH1 900


Side channel blower with IE3-motors

Performance curves

Vacuum operation Compressor operation

1400
50 Hz 50 Hz
1200 60 Hz 60 Hz
1 1
1000 2
2
Suction capacity V [m³/h]

800 3
1 1 4
600 4 2
3 2
400
3
200 34 4

0
500 400 300 200 100 000 100 200 300 400 500 600

Vacuum Total pressure difference p [mbar] Pressure


25,0
4
20,0 3 4 3
4
15,0 2 2 3
3
Power consumption P

4 1 1
10,0 2
at pump shaft [kW]

2
1 1
5,0

0,0
500 400 300 200 100 000 100 200 300 400 500 600

Vacuum Total pressure difference p [mbar] Pressure

140
4 3 4
120 4
3 3
100

80 2 4
3
Temperature rise T

60 2 2
of conveyed air [K]

1
40 1 2
20 1 1

0
500 400 300 200 100 000 100 200 300 400 500 600

Vacuum Total pressure difference p [mbar] Pressure

The performance curves are based on air at a temperature of 15 °C and an Every G-BH pump can be used both as vacuum pump and compressor in
atmospheric pressure of 1013 mbar with a tolerance of ± 10 %. The total continuous operation over the total performance curve range. The motors
pressure differences are valid for suction and ambient temperature up to are available as standard in protection category IP 55 and insulation class
25 °C. For other conditions please get in touch with us. F. The vacuum pumps / compressors are UL and CSA approved.

 Gardner Denver Deutschland GmbH Technical data sheet - Edition 01/2017


.
Selection and ordering data
Type
Max. differential Sound
Fre- Rated Efficiency Weight
pressure 2) pres.
No. quency 3) class 4) approx. Order No.
Voltage 1)
Current Power Vacuum Pressure Level
Hz V A kW mbar dB(A) kg
3~ 50/60 Hz, IP55, Insulation material class F, UL 1004 and CNA/CSA 22.2 No 68-09 (certificate number E225239)
50 190-210  30,8  8,6 -190 180 74 IE3
1 60 190-210  / 380-420  35,6  / 17,8  9,9 -150 140 79 IE3 180 2BH1900-1AK01
60 200  35,6  9,9 -150 140 79 NP
50 190-210  46,4  12,6 -290 280 74 IE3
2 60 190-210  / 380-420  52,8  / 26,4  14,5 -270 260 79 IE3 200 2BH1900-1AK11
60 200  52,8  14,5 -270 260 79 NP
50 190-210  63,1  17,3 -350 460 74 IE3
3 60 190-210  / 380-420  72,2  / 36,1  19,9 -380 410 79 IE3 210 2BH1900-1AK21
60 200  72,2  19,9 -380 410 79 NP
50 190-210  76,2  21,3 -350 500 74 IE3
4 60 190-210  / 380-420  87,4  / 43,7  24,5 -380 460 79 IE3 222 2BH1900-1AK31
60 200  87,4  24,5 -380 460 79 NP
3~ 50/60 Hz, IP55, Insulation material class F, UL 1004 and CNA/CSA 22.2 No 68-09 (certificate number E225239)
50 220-240  / 380-420  26,8  / 15,5  8,6 -190 180 74 IE3
1 60 220-240  / 440-480  31,0  / 15,5  9,9 -150 140 79 IE3 180 2BH1900-1AK06
60 230  / 460  31,0  / 15,5  9,9 -150 140 79 NP
50 220-240  / 380-420  40,3  / 23,3  12,6 -290 280 74 IE3
2 60 220-240  / 440-480  46,0  / 23,0  14,5 -270 260 79 IE3 200 2BH1900-1AK16
60 230  / 460  46,0  / 23,0  14,5 -270 260 79 NP
50 220-240  / 380-420  54,9  / 31,7  17,3 -350 460 74 IE3
3 60 220-240  / 380-420  62,8  / 31,4  19,9 -380 410 79 IE3 210 2BH1900-1AK26
60 230  / 460  62,8  / 31,4  19,9 -380 410 79 NP
50 220-240  / 380-420  66,3  / 38,3  21,3 -350 500 74 IE3
4 60 220-240  / 440-480  76,0  / 38,0  24,5 -380 460 79 IE3 222 2BH1900-1AK36
60 230  / 460  76,0  / 38,0  24,5 -380 460 79 NP
3~ 50/60 Hz, IP55, Insulation material class F, UL 1004 and CNA/CSA 22.2 No 68-09 (certificate number E225239)
50 500  12,4  8,6 -190 180 74 IE3
1 180 2BH1900-1AQ03
60 575  12,2  9,9 -150 140 79 NP
50 500  18,6  12,6 -290 280 74 IE3
2 200 2BH1900-1AQ13
60 575  18,4  14,5 -270 260 79 NP
50 500  25,4  17,3 -350 460 74 IE3
3 210 2BH1900-1AQ23
60 575  25,1  19,9 -380 410 79 NP
50 500  30,6  21,3 -350 500 74 IE3
4 222 2BH1900-1AQ33
60 575  30,4  24,5 -380 460 79 NP
3~ 50/60 Hz, IP55, Insulation material class F, UL 1004 and CNA/CSA 22.2 No 68-09 (certificate number E225239)
50 380-420  / 660-725  15,5  / 8,9  8,6 -190 180 74 IE3
1 60 440-480  15,5  9,9 -150 140 79 IE3 180 2BH1900-1AQ07
60 460  15,5  9,9 -150 140 79 NP
50 380-420  / 660-725  23,3  / 13,4  12,6 -290 280 74 IE3
2 60 440-480  23,0  14,5 -270 260 79 IE3 200 2BH1900-1AQ17
60 460  23,0  14,5 -270 260 79 NP
50 380-420  / 660-725  31,7  / 18,3  17,3 -350 460 74 IE3
3 60 440-480  31,4  19,9 -380 410 79 IE3 210 2BH1900-1AQ27
60 460  31,4  19,9 -380 410 79 NP
50 380-420  / 660-725  38,3  / 22,1  21,3 -350 500 74 IE3
4 60 440-480  38,0  24,5 -380 460 79 IE3 222 2BH1900-1AQ37
60 460  38,0  24,5 -380 460 79 NP

1) In case of frequency converter operation the standard motor insulation system is suitable for converter input voltages up to 500 V.

2) Relief valves available for limiting differential pressure.

3) Measuring surface sound pressure level acc. to EN ISO 3744, measured with an equivalent unit at a distance of 1 m. The pump is throttled to an average suction pressure, with
piping connected, but no relief valves fitted, tolerance ±3 dB (A).

4) The motors according to NEMA MG1-12. NP=NEMA Premium; NEMA Premium includes IE3.

All G-BH match the 2006/42/EC (machinery) and 2006/95/EC (low voltage) directives and the EN 60034 norm “Rotating electrical machines”.

Service factor (SF) and motor efficiency according NEMA MG1-12.


Voltage tolerances for three phase motors are +/-10%.
The frequency tolerance is +/- 2 % maximum.

Motor for alternate voltages


Voltage range
Efficiency
50 Hz 60Hz 4) 60 Hz 2BH1…-1. □ . □

3~

200 V 200 V YY / 230 V / 400 VY


• K 1
190-210 V 190-210 VYY220-240 V / 380-420VY

200 V / 230 V / 400 VY 230 V YY / 460 VY


• K 6
190-210 VYY220-240 V / 380-420VY 220-240 VYY / 440-480VY

475-525 V Y 550-600 V Y • Q 3

475-525 V 550-600 V • Q 5

400 V / 690 V Y 460 V • Q 7

Changes in particular of the quoted performance curve, data and weights may occur without prior notice. The data given does not constitute an obligation from our side to deliver as shown.

Elmo Rietschle is a brand of Gardner Denver Gardner Denver Deutschland GmbH Gardner Denver Schopfheim GmbH
Industriestraße 26 Roggenbachstraße 58
97616 Bad Neustadt - Germany 79650 Schopfheim - Germany
Tel.: +49 9771 6888-0 Tel.: +49 7622 392-0
Fax: +49 9771 6888-4000 Fax: +49 7622 392-300
Your Ultimate Source for Vacuum and Pressure www.gd-elmorietschle.com ▪ er.de@gardnerdenver.com

You might also like