You are on page 1of 1

PROJECT: Greene Street Shade Structure

SHEAR TAB CONNECTION CALC

FOLLOWING ARE THE LOADS TAKEN FOR THE ANALYSIS AND DESIGN OF SHEAR
TAB. THESE ARE THE WORSTCASE LOADS AS STATED BY GKD. HDR TO CONFIRM
THE LOADS TAKEN BY US.

WE DESIGNED TAB FOR LONGSLOT HOLE ALONG THE LENGTH OF MESH.

WE DESGNED WASHER WITH LONG SLOT HOLE ALONG THE LENGTH OF MESH

IF ANY EXPANSION OCCURS DUE TO VARIATION IN TEMPERATURE LONG SLOT


WILL ALLOW MESH TO EXPAND. PERMISSIBLE EXPANSION IS ¾”, HDR TO CONFIRM.

LOAD FZ WILL TRANSFER THRU FRICTION BETWEEN THE PLATES AS IN THE


DIRECTON OF FZ WE HAVE LONGSLOT.

FX WILL TRANSFER THRU BEARING ACTION. LOAD TRANSFER IS FROM BOLT TO


TAB.

FY LOAD IS CONSIDERED FOR THE BENDING OF SHEAR TAB WITH AN ECCENTRICTY


OF 1.75in

FZ WILL BE A TENSILE LOAD TO THE PRIMARY MEMBER, HDR TO CONFIRM.

CHECK ATTACHED CALC FOR FATIGUE CONSIDERATIONS

COEFFICIENT OF FRICTION FOLLOWED AS 0.2, (STAINLESS STEEL TO STAINLESS


STEEL)

NO SHEAR LAG LOADS ARE CONSIDERED AS HDR CONFIRMED IT.

You might also like