KEY PLAN:
1 6 14 25 34
MECCA
U
N
31 32 33 34 43
3.6M CLEARANCE
BELOW INCLINED
T4
SKIN 2.5M CLEARNACE BELOW
INCLINED SKIN
6 7
SKIN REFER TO
SKIN DRAWINGS
687 687
LIMIT OF CONCRETE
SLAB ABOVE
LIMIT OF A
CONCRETE SLAB
800
AI-W02
152
100 600
180
CV LIMIT OF
CONCRETE SLAB
AI-W01
100 1719
1323
SHOWER AI-W03
BATHROOM 2
450
100
AI-W01
2.5 M CLEAR HEIGHT 2.5 M CLEAR HEIGHT
11
℄
2400
2759
787-1 310
J 20 ℄ DROP CAP
2042
1100x1300x490
AI-W01 AI-W01
450
20
14 15
180
830
45
687 687
150
W.P.
W.P.
00
14
MECH MECH 01
SHAFT SHAFT AI-W02
800
787-13
150 R1
1610 0 DOUBLE BEDS
63
1700
AI-W01 AI-W03
LIMIT OF CONCRETE 200 WC
SLAB ABOVE 150 WALK-IN
2590 150
460 S/O
825 CLOSET 665
460S/O
AI-W01
2893
2740
4940 300
W.P.
AI-W02
100
AI-W04 35 35 LIMIT OF
8 CONCRETE SLAB
190 50
687 ABOVE
600 600 120
100
460
VALET AI-W03
30 BOX
R3
30
787-3 ℄ AI-W01
R3
30
600
400
AI-W03
550
OUTDOOR
790
AI-W02
150
180
175
860
1850 LOUNGE
250150
140
1300 S/O
60
CORE 7
W.P.
LIMIT OF CONCRETE
SLAB Q17017-0100D-PK4b(i)-c-TD-T4-AI-787-5OF15
150 1600 S/O 1513 2405 150 150 457
AI-W01 AI-W03
19 FALCON 400
150
787-7 01
GALLERY
787-9 LIMIT OF LEVEL +9.40 M (QNHD) = +0.00 M (ARCHITECTURAL)
CONCRETE SLAB
REFER TO SKIN R1595 REFER TO DRAWING
DETAILS MAXI BAR GENERAL NOTES:
Q17017-0100D-PK4b(i)-c-TD-T4-AI-687-16OF17
W.P.
.W P.
/SHOW KITCHEN
2363
All written dimensions shall have precedence over drawing scale. The
ELEVATOR ELEVATOR ELEVATOR
R11
Engineer shall be notified of any errors or dimensions requiring correction. All
F71 F72 F73 90 GUEST 40 dimensions are to grid line or face of wall finish unless otherwise noted.
9
W.C R 990 REFER TO SKIN 9
DETAILS 687 The Contractor shall provide all necessary blocking, framing, hangers or
DINING other support fixing for fixtures, equipment, cabinetwork or similar requiring
150
13
687 integrated stability. Similarly, all bonding methods for fixing are
W.P.
B 800 x 450 the responsibility of the Contractor. All wall and ceiling linings (including
200
GALLERY
0
Ø30
FALCON
surface finishes, applied coatings and treatments, substrates and framing)
2680
H
2325
150 DROP CAP OUTDOOR are to be non-combustible to meet local authority regulations or to meet the
195
380
150
120
3590
(1348)
100
830 1245 REFER TO DRAWING materials to the Engineer for approval prior to ordering or manufacturing. All
R1
0
25 125
1320
Q17017-0100D-PK4b(i)-c-TD-T4-AI-787-13OF15
36
19
AI-W01
construction shall comply with all current local building codes and regulations.
13090
0
410 All Drawings shall be read in conjunction with the project specifications and
ELEVATOR
(1348) 150
2487
SUITE BARBER R9
4 0
EQ
CORNER
110 1420
AI-W01
25
410
362
350
50
150
01
150
9 2108 150
B 600 x 600
787-11
475
150
100
150
687 150 150 130 1650 150
75 11
AI-W01
687
9355
01
LIBRARY 787-1 REVISION
1900 S/O
2850
2160
1900
2325
2650
10
1400 S/O ℄
150
465
150
687
OUTDOOR
237
250 11645
170
150
25
25 LIVING
AI-W01
AI-W01 687 AREA
1550
16
2324
06 787-2
410
787-10 08
75 23
787-16 121 1600 S/O 3260 2238 1038
150 945 150 687
150 AI-W03 150 150 AI-W03 150 150
150
B 800 x 450
150
C.V. MECH
380
150
SHAFT
195
G 1600 S/O
(627)
DROP CAP
EQ
AI-W01
1600 S/O PRIVATE
220
1030
1850 EQ. 1100x1600x450EQ.
200
01
STUDY
310 1115
1750 787-8
150
W.P.
3095
3095
1820
EQ
AI-W03
21 20 UP 22 24
687 687 EQ1 EQ1 EQ1 EQ1 687 687
550 (766) (766) (766) (766) 50
KATARA TOWERS AT LUSAIL
4500
50
(940)
EQ
AI-W03
11 LIMIT OF CONCRETE
CINEMA Lusail District, Doha
(627)
787-15
620
AI-W03 AI-W01 AI-W03 SLAB ABOVE
EQ
REFER TO SKIN AI-W01
300
150
150
W .P.
W.P.
DETAILS
40
100
CLIENT
1290
(940)
110
EQ
Katara Hospitality
530
530
166
AI-W01 AI-W02 AI-W02
150 WALK-IN
1170
1600 S/O
R3
CLOSET
1722
R3
1050
AI-W02 880 687 687
1
1365 Lusail City, PO Box 2977 Doha, Qatar
66
LIMIT OF 175 NICHE FOR DRESSING
CONCRETE SLAB
4
460
85
TABLE & JEWELERY BOX
85
W.P.
150
LIMIT OF CONCRETE
650
0
DRAWER LEAD
1300 S/O
100
SLAB
35
35
100
23 OUTDOOR CONSULTANT
615
AI-W01
01 770 R31
CORE 8
787-3 LOUNGE
4
166 66
647
VALET
45
460
R5555
787-16
AI-W03
R3
BOX
R1
150
200
50 AI-W02
LUGGAGE RACK
50
150
AI-W03
05 10 REFER TO SKIN
W.P.
SHOWER 787-11
1460
LIMIT OF
CONCRETE 500 16 17 CONSULTANTS
SLAB ABOVE AI-W03 687 687
100 11
SHAFT 2060 150 1942
W.C 787-4
4375
150
100
CONC PAD
180 19
CONC PAD
W.P.
W.P.
AI-W01 AI-W02
1455
787-2
787-3 1100x1300x490
100
F
01
2.5 M CLEAR HEIGHT 787-4 2.5 M CLEAR HEIGHT
600
100 3750
MASTER
1900
100
BATHROOM
600
LUSAIL HOTEL
2250
LIMIT OF
180
CV
830
1875
SAUNA SKIN REFER TO
[ PK4b(i)-c & PK4b(ii)-c ]
SKIN DRAWINGS
AI-W02
IGHT SUBMISSION
EAR HE ISSUED FOR CONSTRUCTION
2.5 M CL STAMP
OCTOBER 2020 PACKAGE PK4b(i)-c
LIMIT OF
CONCRETE SLAB PACKAGE TITLE
Marina-hotel 001 /
BUILDES WORKS PLAN REFER TO DRAWING A0 02.10.2020 NK CM 1:50
01 Q17017-0100D-PK4b(i)-c-TD-T4-AI-687-8OF17
PROJECT NO. PHASE BLDG. NO. DISCIPLINE SERIAL NO. PART
LUSAIL
REV. NO.
687 SCALE 1:50
Q17017-0100D FC T4 AI 687 1 OF 17 00
KEY PLAN:
1 6 14 25 34
MECCA
U
J N
43
T4
A
M8x30
M8
M8
M8
35
36 787-7
F-ST-58 787-7
03 F-PT-03 F-ST-58
787-4
120
295
3100 AFFL 3100 AFFL
35
787-3
1500
F-ST-58
F-TL-02
1785
F-ST-58
3220
3000
3100
2830 S/O
2830 S/O
S-FA-01
170
1500
S-AC-01
LEVEL +9.40 M (QNHD) = +0.00 M (ARCHITECTURAL)
S-FA-03
1020
850
S-WH-02 All written dimensions shall have precedence over drawing scale. The
S-WH-02
Engineer shall be notified of any errors or dimensions requiring correction. All
350
dimensions are to grid line or face of wall finish unless otherwise noted.
F-ST-58 F-ST-58 F-ST-58
The Contractor shall provide all necessary blocking, framing, hangers or
100
100
100
other support fixing for fixtures, equipment, cabinetwork or similar requiring
integrated stability. Similarly, all bonding methods for fixing are
the responsibility of the Contractor. All wall and ceiling linings (including
surface finishes, applied coatings and treatments, substrates and framing)
M8x30
M8
M8
M8
are to be non-combustible to meet local authority regulations or to meet the
equivalent standards of non-combustibility of adopted regulations in force.
The Contractor shall provide all necessary shop fabrication drawings to the
S-WH-01 S-FA-55 Engineer for checking prior to manufacture to ensure that design integrity is
S-FA-05 S-FA-51 maintained. The Contractor is to provide finished samples of all exposed
materials to the Engineer for approval prior to ordering or manufacturing. All
construction shall comply with all current local building codes and regulations.
50 ELEVATION 51 ELEVATION All Drawings shall be read in conjunction with the project specifications and
687 687 drawings related to all other disciplines.
SCALE 1:20 SCALE 1:20
REVISION
M8
F-TL-02
F-ST-58 F-ST-58
49 47 50 52
687 687 687 687
120
270
PROJECT
35
L E AR HEI 687
2.5 M C CLIENT
F-ST-58 F-ST-58
Katara Hospitality
Katara Hospitality Building, Marina District,
Lusail City, PO Box 2977 Doha, Qatar
3220
48
3100
3100
3100
687 LEAD
CONSULTANT
2795
2.5 M CLEA
1500
SUB -
S-AC-01 CONSULTANTS
1100
1060
51
687
580
S-WH-01
F-ST-58 F-ST-58
100
100
53
687
12
M8x30
M8
M8
M8
Marina-hotel 001 /
A0 02.10.2020 NK CM 1:20 LUSAIL
PROJECT NO. PHASE BLDG. NO. DISCIPLINE SERIAL NO. PART REV. NO.
Q17017-0100D FC T4 AI 687 15 OF 17 00
KEY PLAN:
1 6 14 25 34
MECCA
U
N
06 04 05 07 43
787-4 787-4 787-4 787-4
L
T4
09
295
295
295
295
A
787-4
10
10
30
LEGENDS & PARTICULAR NOTES:
10
10
30
180
10
180
180
30 30
180
180
180
F-ST-58 F-ST-58
BOOK MATCHED BOOK MATCHED
180
180
10 10 10
2250
2250
2250
180
180
180
1820
1800
1800
1800
1740
10
200 200 180
180
180
180
F-MR-16 F-MR-02 F-MR-02 F-MR-16
180
180
3100
3100
3100
01
787-4
180
180
MIRROR TV
F-MR-02
180
180
180
180
30
30
30
LEVEL +9.40 M (QNHD) = +0.00 M (ARCHITECTURAL)
10
10
10
10
S-FA-55 S-FA-55
S-FA-55 GENERAL NOTES:
700 700 700
S-FA-55
135
135
135
135
135
100 600 100 600 100 600 S-FA-55 100 600 All written dimensions shall have precedence over drawing scale. The
120 80
Engineer shall be notified of any errors or dimensions requiring correction. All
130
S-WH-51 F-ST-58 S-WH-51 F-ST-58 dimensions are to grid line or face of wall finish unless otherwise noted.
F-ST-58
270
270
270
BOOK MATCHED
BOOK MATCHED The Contractor shall provide all necessary blocking, framing, hangers or
RECESSED MINI
SPOT LIGHT other support fixing for fixtures, equipment, cabinetwork or similar requiring
RECESSED MINI integrated stability. Similarly, all bonding methods for fixing are
F-ST-58 EQ EQ SPOT LIGHT
F-ST-58 the responsibility of the Contractor. All wall and ceiling linings (including
750
02
F-ST-58 surface finishes, applied coatings and treatments, substrates and framing)
850
850
850
850
850
EQ BOOK MATCHED F-ST-58
370
370
370
787-4 (200) EQ
400 are to be non-combustible to meet local authority regulations or to meet the
F-ST-58 BOOK MATCHED
(200)
BOOK MATCHED
40 40 equivalent standards of non-combustibility of adopted regulations in force.
350 350
The Contractor shall provide all necessary shop fabrication drawings to the
F-WD-12 F-WD-12
TOWELTRAY TOWELTRAY
Engineer for checking prior to manufacture to ensure that design integrity is
(110)
110
110
110
EQ
100
100
100
100
100
F-ST-58 F-ST-58 construction shall comply with all current local building codes and regulations.
All Drawings shall be read in conjunction with the project specifications and
03 MASTER VANITY FRONT VIEW 04 VANITY SIDE SECTION 05 VANITY SIDE SECTION 06 VANITY SIDE SECTION 07 VANITY SIDE SECTION drawings related to all other disciplines.
04
787-4 SCALE 1:10 05 07 787-4 SCALE 1:10 787-4 SCALE 1:10 787-4 SCALE 1:10 787-4 SCALE 1:10
787-4 10 10 10
787-4 787-4
787-4 787-4 787-4
08
787-4
10
EQ1 EQ1 EQ1
30
100
REVISION
45
1940 30
120
120
CONCEALED LED
LIGHT DATE REV. APP. BY REVISION DETAILS
EQ EQ
(900) (900) 5 02.10.2020 00 JH APPROVED ISSUE
R1
180 200 200 200 180
F-MR-02 F-ST-58
700
20
600
600
600
400
45
45
40
90
F-GL-12
20
3
BACKLIT GLASS
(22.5) (22.5) (22.5)
EQ1 EQ1 EQ1
80
100
400 500 600 500 400 F-MR-05
45
06
100
787-4 2400
10 45 90 45 10 30 F-ST-58
EQ
01 BATHROOM VANITY TOP VIEW (180)
F-ST-58 S-WH-51 S-AC-15
787-4 SCALE 1:10 BOOK MATCHED ELEVATION
1020 80
F-ST-58 120
Katara Hospitality
350
700
LEAD
600
120
CONSULTANT
40 40
800
350
350
100
100
EQ EQ TIMBER BACKING SUB -
(200) 2000 (200) F-ST-58 CONSULTANTS
2400 180
F-TL-02
OR
F-ST-58 F-ST-58 100 20 F-ST-58
02 BATHROOM VANITY PLAN SECTION 10 10 F-ST-58
SKIRTING PROJECTION BOOK MATCHED BOOK MATCHED VAR.
F-ST-58 120
270
UNDER VANITY
787-4 SCALE 1:10 INDIRECT LIGHT (TO BE
645
S-AC-07
150
F-ST-58
80
F-ST-58
270
240
26
170
50 S-FA-68 F-ST-58
[ PK4b(i)-c & PK4b(ii)-c ]
0
R3
70
75
100 S-FA-07
100
100
100
1660
640
26
R30 SUBMISSION
ISSUED FOR CONSTRUCTION
370
370
S-FA-10
5
50 PACKAGE PK4b(i)-c
12
OCTOBER 2020
12
25
16
67
4
35
° PACKAGE TITLE
787-4
240
23
12
10 10
20
70
70
22.5 45 45 45 22.5
1920 S-FA-09 PK4b(i) 32ND FLOOR LEVEL- FALCON SUITE
(250)
EQ1
180 180 30
130 830 13
787-4 -c- FALCON SUITE DETAILS - BATHROOM DETAILS
70
F-TL-02
FORMAT FIRST ISSUE DATE DESIGNED BY CHECKED BY SCALE PLOT NO. / AREA
(ISSUE OF REV00)