DX-627/1227
6/12 CHANNEL DMX DIMMER PACK
Lite-Puter
ISO 9001 CERTIFIED www.liteputer.com.tw
CONTENTS:
Safety Introduction................................................................................................2
Chapter 1 Introduction of DX-627/DX-1227 .......................................................3
1-1 Feature ......................................................................................................................3
1-2 Specification............................................................................................................3
x
1-3 Operation Panel Function Introducing .............................................................4
.m
1-4 Output Rear Panel Introducing ...........................................................................5
1-5 Wiring Diagram ......................................................................................................6
Chapter 2 Operation ..............................................................................................7
m
2-1 Standard DMX 512 Signal ..................................................................................7
o
2-2 DMX Start Address Setting .................................................................................7
2-3 Channel Output Status Preview .........................................................................8
.c
2-4 Output Testing ........................................................................................................8
za
2-5 Dimming / Switching Setting .............................................................................8
2-6 Warn-Up Setting (0…6%)...................................................................................9
2-7 Output Limit Setting .............................................................................................9
do
2-8 Internal Temperature ...........................................................................................10
2-9 DMX Status & DMX Address ..........................................................................10
en
sm
lo
ar
.c
w
w
w
1 Lite-Puter
DX-627/1227 [EUM-B]
ISO 9001 CERTIFIED www.liteputer.com.tw
Safety Introduction
x
.m
Please refer to the data we suggest to ensure the normal total working hours of
DX-627/ DX-1227:
m
1. If DX-627/ DX-1227 is installed in a rack, please make sure the rack is airy.
o
Otherwise the machine will become over-heat and result in the
.c
mis-function.
za
2. DX-627/ DX-1227 The max output of each channel is 20A:For testing (Do
not over 30 minutes.)
do
3. DX-627/DX-1227 The max output of each channel is ≦16A:For several
hours use. (Theaters, stages)
en
building.)
lo
Working Environment:
ar
2. If the machine is installed in a rack, then the temperature inside the rack
must be under 45°C.
w
2 Lite-Puter
DX-627/1227 [EUM-B]
ISO 9001 CERTIFIED www.liteputer.com.tw
x
1-1 Feature
.m
Automatic frequency sensor can detect power frequency
m
(45Hz~63Hz) in different areas and stabilizes the dimming output.
The thermo-controlled fan will be activated automatically when the
o
temperature is over 45℃.
.c
The intelligent thermo-protection will cease the output when the
temperature is over 85℃ and restart output below 65℃.
za
Each channel can be set as dimming or non-dimming.
Self-testing function to test without a console.
do
Dimmer level and internal temperature monitor.
Warm up function to protect the loads. (Warm up setting 0%~6%)
en
1-2 Specification
lo
ar
Signal Connector XLR 5-pin( Male x1, Female x1), 6p4c phone jack
(x2)
w
3 Lite-Puter
DX-627/1227 [EUM-B]
ISO 9001 CERTIFIED www.liteputer.com.tw
x
.m
1 2 3 4 5 6 7 8 9 10
m
(1) DMX IN (Phone jack). (6) ▼ BUTTON.
(2) N.F.B (1-3CH). (7) FUNCTION BUTTON.
o
(3) CHANNEL BUTTON (1-3CH). (8) ENTER BUTTON.
.c
(4) LED DISPLAY (9) CHANNEL BUTTON (4-6CH).
za
(5) ▲ BUTTON. (10) N.F.B (4-6CH).
do
en
sm
lo
ar
.c
1 2 3 4 5 6 7 8 9 10
w
4 Lite-Puter
DX-627/1227 [EUM-B]
ISO 9001 CERTIFIED www.liteputer.com.tw
x
.m
m
11 12 13 14
o
(11) DMX IN(XLR-5 pin) (13) Output terminal board
.c
(12) DMX IN(RJ11, phone jack) (14) Power input terminal board
za
do
en
sm
lo
ar
.c
11 12 13 14
(11) DMX IN(XLR-5 pin) (13) Output terminal board
w
(12) DMX IN (RJ11, phone jack) (14) Power input terminal board
w
w
5 Lite-Puter
DX-627/1227 [EUM-B]
ISO 9001 CERTIFIED www.liteputer.com.tw
3 PHASES 4 WIRES E
N N
THE BEST WIRING DIAGRAM R V1
x
S V2
.m
T V3
m
SINGLE PHASES E
2 WIRES N N
o
V V1
V2
.c
V
V3
za
do
en
sm
lo
ar
.c
w
w
w
6 Lite-Puter
DX-627/1227 [EUM-B]
ISO 9001 CERTIFIED www.liteputer.com.tw
Chapter 2 Operation
x
.m
m
This point flashing when receiving
o
.c
2-2 DMX Start Address Setting
za
STEP-1 Hold【ENTER】,press【▼】or【▲】 to find the start address.
【ENTER】+【▲】: move 1 number forward.
do
【ENTER】+【▼】: move 1 number backward.
Up to 512 Channel
en
sm
lo
7 Lite-Puter
DX-627/1227 [EUM-B]
ISO 9001 CERTIFIED www.liteputer.com.tw
x
.m
STEP-2 Press【▼】or【▲】to preview.
m
Channel 4= 100% Full
o
.c
2-4 Output Testing
za
STEP-1 Press channel button for full load output.
do
STEP-2 Press channel button again for turn off output.
en
(dimming)
(switching)
8 Lite-Puter
DX-627/1227 [EUM-B]
ISO 9001 CERTIFIED www.liteputer.com.tw
Channel 1= Switching
x
.m
2-6 Warn-Up Setting (0…6%)
o m
STEP-1 Press【FUNC】button until the LCD displays as below
.c
STEP-2 Press【▼】or【▲】to adjust.
za
do
All channels are set on 6% for warm
en
sm
9 Lite-Puter
DX-627/1227 [EUM-B]
ISO 9001 CERTIFIED www.liteputer.com.tw
x
( temperature of left side heat sink)
.m
m
( temperature of right side heat sink)
o
.c
The thermo-controlled fan will be activated automatically when
za
the temperature is over 45℃. The fan will be stopped when the
temperature is below 40℃
The intelligent thermo-protection will cease the output when
do
the temperature is over 85℃ and restart output below 65℃.
en
sm
lo
In the middle of any of setting, press【ENTER】, the machine can immediately return