Critical support reactions on most stressed anchor rod were obtained from Bottom Bracket Connection (BKT5) finite
element analysis attached in appendix A (Refer to MALL-TGAC-ML-GF-STR-CAL-00650)
Note: Software is used to check only the concrete edge breakout due to shear forces. Software design report is
attached for reference, refer to appendix B.
Software Input:
APPENDIX A
3
+%27720%5$&.(7&211(&7,21%.7
68332575($&7,216
Refer to attached Canopy Frame STAAD Support Reactions on page 20-22/22.
&DVH
Reaction along x-axis Rx1 3.84kN
Reaction along y-axis Ry1 8.60kN
Reaction along z-axis Rz1 19.17 kN
&DVH
Reaction along x-axis Rx2 3.81kN
Reaction along y-axis Ry2 12.10 kN
Reaction along z-axis Rz2 21.69 kN
:(/'&+(&.
Weld thickness tw 8.00mm
Weld throat size aw 0.707 tw 5.66 mm
Weld design strength pw 202.00MPa
Material factor γM 1.10
Weld depth dw 250.00mm
Weld breadth bw 150.00mm
Weld total unit length
Lw 2 dw bw 800.00 mm
pw aw Lw
Weld allowable load wwall 830.92 kN
γM
Uniform load due to axial load
fzw max Rz1 Rz2 21.69 kN
Uniform load due to vertical shear load fyw max Ry1 Ry2 12.10 kN
76
4
%$6(3/$7(&+(&.
67$$',QSXW
&DVH
Reaction along x-axis Rx1 3.84kN
Reaction along y-axis Ry1 8.60kN
Reaction along z-axis Rz1 19.17 kN
&DVH
Reaction along x-axis Rx2 3.81kN
Reaction along y-axis Ry2 12.10 kN
Reaction along z-axis Rz2 21.69 kN
$1&+25%2/7&+(&.
$QFKRU3URSHUWLHV
Diameter of Anchor do 16mm
2
π do 2
Effective cross sectional area of anchor Ase 0.75 150.80 mm
4
Compressive Strength fc 40.00 MPa
Tensile Strength
3ODWH3URSHUWLHV futa 700.00MPa
Design Strength py 275.00MPa
77
5 Page 1 of 4
Job Information
Engineer Checked Approved
Name: SGT
Date: 08-Julr-19
Primary 1 CASE 1
Primary 2 CASE 2
Plate Thickness
Prop Node A Node B Node C Node D Material
(mm) (mm) (mm) (mm)
1 12.00 12.00 12.00 12.00 STEEL
0 .0
5
m 0m
0.030
m
0.180 0.1
0 .0 6 6m
50 30m
0.0
m
0.1
66
m
0.346m
m
0.150
m
0.240
0.250m
0 .2
16
m
0.119m
Y
X
Z Load 1
STRUCTURAL MODEL
78
6 Page 2 of 4
19.17 kN
3.84 kN
Y
X Load 1
Z
8.60 kN
-12.10 kN
-3.81 kN
Y
X Load 2
Z
-21.69 kN
79
7 Page 3 of 4
Max Absolute
MPa
<= 0.019 STRESS CHECK:
3.25 Maximum stress = 51.70MPa
6.48 Design strength S275 = py = 275.00MPa
9.72 Materia factor = MF = 1.1
12.9 Permissible strength = py/MF = 250.00MPa
16.2 Max. stress < Per. strength, "Therefore OK!"
19.4
22.6
25.9
29.1
32.3
35.6
38.8
42
45.3
48.5
>= 51.7
Y
X Load 1
Z
Max Absolute
MPa
<= 0.009
2.75 STRESS CHECK:
5.5
8.24
Maximum stress = 43.90MPa
Design strength S275 = py = 275.00MPa
11
Materia factor = MF = 1.1
13.7
Permissible strength = py/MF = 250.00MPa
16.5
Max. stress < Per. strength, "Therefore OK!"
19.2
22
24.7
27.4
30.2
32.9
35.7
38.4
41.2
>= 43.9
Y
X Load 2
Z
80
8 Page 4 of 4
X = -0.19 kN
Y = -0.01 kN
Z = 0.31 kN
X = -0.20 kN
Y = 0.02 kN
Z = -0.45 kN
X = -0.98 kN
Y = 0.14 kN
Z = -6.35 kN
X = -2.47 kN
Y = 0.12 kN
Z = -12.68 kN
Y
X Load 1
Z
X = 0.33 kN
Y = -0.50 kN
Z = -2.26 kN
X = 0.02 kN
Y = -0.47 kN
Z = -1.56 kN
X = 1.18 kN
Y = 0.66 kN
Z = 4.14 kN
X = 2.28 kN
Y = 0.60 kN
Z = 8.95 kN
Y
X Load 2
Z
81
9
V Tb
Interaction Ratio R 0.36
Vsad Nsad
V
Bearing of bolt to concrete fp 3.59 MPa
Ab
Nominal bearing of concrete Fp 0.85 fc 34.00 MPa
82
10
APPENDIX B
11
Specifier's comments:
1 Input data
Anchor type and size: HIT-HY 200-R + HIT-V-R M16
Seismic/Filling set or any suitable annular gap filling solution
Effective embedment depth: hef,act = 114 mm (hef,limit = - mm)
Material: A4
Approval No.: ETA 12/0084
Issued I Valid: 07/08/2019 | -
Proof: SOFA design method + fib (07/2011) - after ETAG BOND testing
Stand-off installation: eb = 0 mm (no stand-off); t = 12 mm
Baseplate: lx x ly x t = 200 mm x 120 mm x 12 mm; (Recommended plate thickness: not calculated
Profile: no profile
Base material: cracked concrete, C40/50, fc,cyl = 40.00 N/mm2; h = 150 mm, Temp. short/long: 30/40 °C
Installation: hammer drilled hole, Installation condition: Dry
Reinforcement: No reinforcement or Reinforcement spacing >= 150 mm (any Ø) or >= 100 mm (Ø <= 10 mm)
with longitudinal edge reinforcement d >= 12 + close mesh (stirrups, hangers) s <=
R
- The anchor calculation is based on a rigid baseplate assumption.
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
12
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
13
Comments: Tension displacements are valid with half of the required installation torque moment for uncracked concrete! Shear displacements
are valid without friction between the concrete and the baseplate! The gap due to the drilled hole and clearance hole tolerances are not
included in this calculation!
The acceptable anchor displacements depend on the fastened construction and must be defined by the designer!
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
14
6 Warnings
• The anchor design methods in PROFIS Anchor require rigid baseplates per current regulations (ETAG 001/Annex C, EOTA TR029, etc.).
This means load re-distribution on the anchors due to elastic deformations of the baseplate are not considered - the baseplate is assumed to
be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Anchor calculates the minimum required
baseplate thickness with FEM to limit the stress of the baseplate based on the assumptions explained above. The proof if the rigid baseplate
assumption is valid is not carried out by PROFIS Anchor. Input data and results must be checked for agreement with the existing conditions
and for plausibility!
• The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to
be followed to ensure a proper installation.
• Drilled hole cleaning must be performed according to instructions for use (blow twice with oil-free compressed air (min. 6 bar), brush twice,
blow twice with oil-free compressed air (min. 6 bar)).
• Characteristic bond resistances depend on short- and long-term temperatures.
• Please contact Hilti to check feasibility of HIT-V rod supply.
• The design method fib (07/2011) assumes that no hole clearance between the anchors and the fixture is present. This can be achieved by
filling the gap with mortar of sufficient compressive strength (e.g. by using the HILTI Seismic/Filling set) or by other suitable means
• The compliance with current standards (e.g. EC3) is the responsibility of the user
• Checking the transfer of loads into the base material is required in accordance with fib (07/2011)!
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
15
7 Installation data
Baseplate, steel: - Anchor type and size: HIT-HY 200-R + HIT-V-R M16
Profile: no profile Installation torque: 0.080 kNm
Hole diameter in the fixture: df = 18 mm Hole diameter in the base material: 18 mm
Plate thickness (input): 12 mm Hole depth in the base material: 114 mm
Recommended plate thickness: not calculated Minimum thickness of the base material: 150 mm
Drilling method: Hammer drilled
Cleaning: Compressed air cleaning of the drilled hole according to
instructions for use is required
y
-50
100 100
60
90
x
30
60
1
30
50 150
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
16
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan