You are on page 1of 32

WARNING: THIS DOCUMENT, OR AN EMBODIMENT OF IT IN ANY MEDIA, DISCLOSES INFORMATION WHICH IS PROPRIETARY, IS THE PROPERTY OF

SIKORSKY AIRCRAFT CORPORATION AND/OR ITS SUBSIDIARIES, IS AN UNPUBLISHED WORK PROTECTED UNDER APPLICABLE COPYRIGHT LAWS, AND IS
DELIVERED ON THE EXPRESS CONDITION THAT IT IS NOT TO BE USED, DISCLOSED, REPRODUCED, IN WHOLE OR IN PART (INCLUDING REPRODUCTION
AS A DERIVATIVE WORK), OR USED FOR MANUFACTURE FOR ANYONE OTHER THAN SIKORSKY AIRCRAFT CORPORATION AND/OR ITS SUBSIDIARIES
WITHOUT ITS WRITTEN CONSENT, AND THAT NO RIGHT IS GRANTED TO DISCLOSE OR SO USE ANY INFORMATION CONTAINED HEREIN. ALL RIGHTS
RESERVED. ANY ACT IN VIOLATION OF APPLICABLE LAW MAY RESULT IN CIVIL AND CRIMINAL PENALTIES.
EXPORT WARNING: THESE COMMODITIES, TECHNICAL DATA OR SOFTWARE ARE SUBJECT TO THE EXPORT CONTROL OF EITHER THE INTERNATIONAL
TRAFFIC IN ARMS REGULATIONS (ITAR) OR THE EXPORT ADMINISTRATION REGULATIONS (EAR) AND CANNOT BE EXPORTED WITHOUT THE
AUTHORIZATION OF EITHER THE DEPARTMENT OF STATE OR THE DEPARTMENT OF COMMERCE PRIOR TO EXPORT. EXPORT INCLUDES DISCLOSURE
AND OR ACCESS TO COMMODITIES, TECHNICAL DATA OR SOFTWARE BY FOREIGN NATIONALS WHETHER LOCATED IN THE UNITED STATES OR ABROAD.
THIS REQUIREMENT APPLIES EQUALLY TO FOREIGN NATIONAL EMPLOYEES OF U.S. COMPANIES AND THEIR FOREIGN SUBSIDIARIES.

No. 92-085

Subject: DOORS – Perform a One-Time Modification to Prevent Chafing in the Ramp Control Panel

1. PLANNING INFORMATION

A. Purpose
This Customer Service Notice (CSN) provides instructions to modify the ramp control panel
to prevent chafing of the ramp control panel’s internal wire harnesses.

This modification secures the wire harnesses within the ramp control panel to avoid contact
with any element inside the panel such as rivets or panel walls.

B. Effectivity
S-92 helicopters delivered with ramp control panel, part number 92550-03801-101, having
the following serial numbers:
C001 to C006, C320-00007 to C320-00022, B320-00023 to B320-00177, B320-00179,
B320-00181 to B320-00188, B320-00190, B320-00191.

C. Components
Ramp Control Panel Part No. 92550-03801-101.

D. Description

The ramp control panel is removed and Aernnova Service Bulletin No. ANN-S92-006, dated
Dec 22, 2010 is reviewed and complied with. The ramp control panel is reinstalled.
Helicopter is returned to service.

April 28/11 Page 1 of 6 52-31-01


No. 92-085
DOORS – Perform a One-Time Modification to Prevent Chafing in the Ramp Control Panel

1. PLANNING INFORMATION (Continued)

E. Compliance

Sikorsky Aircraft recommends compliance with this CSN. The instructions outlined herein
are to be performed at the discretion of the operator. Review and comply with Aernnova
Service Bulletin No. ANN-S92-006, dated Dec 22, 2010.

F. Approval

The change affected by this document is classified as Minor, and is FAA approved in
accordance with the applicable requirements of United States Federal Aviation Regulations
14 CFR 29. This constitutes EASA approval under the terms of the current interim
procedures for working with the European Community on airworthiness certification and
continued airworthiness. The design data provided in this document is automatically
approved by EASA Decision No. 2004/04/CF, as amended by EASA Decision No. 2007/
001/C. Reference to the EASA Decisions mentioned above shall be made in the release
documents issued by the EASA 145 approved organization, releasing the relevant EU
registered helicopter or component to service.

G. Manpower (Estimated)

See Aernnova Service Bulletin No. ANN-S92-006, dated Dec 22, 2010.

H. Weight and Balance

See Aernnova Service Bulletin No. ANN-S92-006, dated Dec 22, 2010.

I. Electrical Load Data

See Aernnova Service Bulletin No. ANN-S92-006, dated Dec 22, 2010.

J. Software Load Data

Not applicable.

K. References

(1) Maintenance Manual, SA S92A-AMM-000, Chapter/Section 52-31-01-900-001/-002.

(2) Special Tools and Ground Support Equipment Manual, SA S92A-GSE-000.

L. Publications Affected

None.

M. Attachment

Aernnova Service Bulletin No. ANN-S92-006, dated Dec 22, 2010.

April 28/11 Page 2 52-31-01


No. 92-085
DOORS – Perform a One-Time Modification to Prevent Chafing in the Ramp Control Panel

2. MATERIAL INFORMATION

A. Basis for Material Data

Per helicopter.

B. Bill of Material

Instructions/
Part No. Qty Key Word Old Parts Disposition
92200-03070-011 1 Modification Kit (1)(3)

consisting of:

UNEX 1257 1 Polyamide Angle Mounting


Fitting
UNEX 2221 3 Polyamide Cable Tie
RAYCHEM TFE-R 1/4 1 Heat Shrinkable Sleeve

92200-03070-013 1 Modification Kit (2)(3)

consisting of:

UNEX 1256-9 1 Bracket


UNEX 2221 2 Polyamide Cable Tie
PEMSA 91022060 1 Spiral Tape
RAYCHEM TFE-R 1/4 1 Heat Shrinkable Sleeve

(1) To be used on ramp control panel serial numbers C001 to C006, C320-00007 to
C320-00022, B320-00023 to B320-00051, B320-00053 to B320-00060, B320-00063,
B320-00065, B320-00066, B320-00070 to B320-00079, B320-00080.

(2) To be used on ramp control panel serial numbers C001 to C006, C320-00007 to
C320-00022, B320-00023 to B320-00177, B320-00179, B320-00181 to B320-00188,
B320-00190, B320-00191.

(3) Modification kit is available to operators free of charge. Operators must pay for
shipping costs. For modification kit availability and lead time requirements contact
your Customer Service Representative at Helicopter Support, Inc. (HSI). Submit a
purchase order referencing this CSN number and helicopter serial number upon
which the modification kit(s) will be used. This will allow HSI and the operator to
track shipment and receipt of the modification kit(s). Orders will be accepted by
letter, telephone, facsimile (FAX), or HSI website: www.HSIUS.com. For prompt
shipment, reference address of each shipping destination. Direct your order to:

HELICOPTER SUPPORT INC.


124 Quarry Road
P.O. Box 11068
Trumbull, Connecticut 06611 U.S.A.
Attn: Customer Service
FAX: (203) 416-4291 Telephone: (203) 416-4000

April 28/11 Page 3 52-31-01


No. 92-085
DOORS – Perform a One-Time Modification to Prevent Chafing in the Ramp Control Panel

2. MATERIAL INFORMATION

HSI website: www.HSIUS.com

C. Consumable Material

See Aernnova Service Bulletin No. ANN-S92-006, dated Dec 22, 2010.

D. Tools Required

See Aernnova Service Bulletin No. ANN-S92-006, dated Dec 22, 2010.

3. ACCOMPLISHMENT INSTRUCTIONS

A. Prepare helicopter for maintenance as follows:

TO PREVENT ELECTRICAL SHOCK OF PERSONNEL, MAKE


WARNING
SURE TO DEENERGIZE ELECTRICAL POWER.

(1) Deenergize electrical and hydraulic power.

(2) Engage rotor brake.

B. Modify ramp control panel as follows:

(1) Remove ramp control panel. Refer to Maintenance Manual, SA S92A-AMM-000,


Chapter/Section 52-31-01-900-001.

(2) Review and comply with Aernnova Service Bulletin No. ANN-S92-006, dated Dec 22,
2010.

(3) Install ramp control panel. Refer to Maintenance Manual, SA S92A-AMM-000,


Chapter/Section 52-31-01-900-002.

(4) Examine components for security. Make sure area is clean and free of foreign
objects.

(5) Return helicopter to service.

April 28/11 Page 4 52-31-01


No. 92-085
DOORS – Perform a One-Time Modification to Prevent Chafing in the Ramp Control Panel

3. ACCOMPLISHMENT INSTRUCTIONS (Continued)

C. Record of Compliance Electronically

NOTE: • Record using one of the following compliance methods:


• Use section C. as a guide when completing the Record of Compliance
Electronically on Sikorsky360 website.
• Use section D. when completing the Record of Compliance Manually.

Make an appropriate logbook entry to show compliance with this CSN.

(1) Log onto WWW.Sikorsky360.com

(2) Click on E-Notifications.

NOTE: Please read the Export Control Statement before agreeing to the terms and
conditions.

(3) Agree to the Export Control Statement.

(4) Click on E-Notes Compliance.

(5) To perform the E-Notification Compliance, select Search by DOCUMENT NUMBER


tab and follow the steps 1 through 6 in Figure 1.

(6) Once search is complete, select COMPLY next to the helicopter that is in
compliance and follow step 7 through 11 in Figure 1.

D. Record of Compliance Manually

Make an appropriate logbook entry to show compliance with this CSN.

Upon compliance with this CSN, complete attached CUSTOMER SERVICE NOTICE
COMPLIANCE RECORD and return it to Sikorsky Aircraft Corporation.

April 28/11 Page 5 52-31-01


No. 92-085
DOORS – Perform a One-Time Modification to Prevent Chafing in the Ramp Control Panel

USE AS A GUIDE, INFORMATION WILL VARY

User Guide Add New Aircraft


E-Notifications E-Notes Search
Compliance

Search by DOCUMENT NUMBER Search by AIRCRAFT

E-Notification Type* Model* Document Number* Compliance Status*


SELECT ALL - CLEAR ALL CSN 92-001 SELECT ALL - CLEAR ALL
CSN 92-002
ASB/SB - Alert Service Bulletin / Service Bulletin CSN 92-003A Complied

1 SELECT DOC TYPE CSN - Customer Service Notice CSN 92-004B Not Applicable
CSN 92-005B
CSN 92-006
Open SELECT OPEN 5
CSN 92-007 Waiting Parts
CSN 92-008
CSN 92-009A
CSN 92-010
SELECT DOC NUMBER 4
2 SELECT MODEL S-92A CSN 92-011

Load List SELECT LOAD LIST 3


* Required
To search e-notification compliance by document number:

Select E-Notification Type(s) and Model(s) and click the “Load List” button, then
Select Document Nlumber(s) and Compliance Status(es) and click the “Search”
button.

HINT: Hold the CTRL button to select multiple items.

Clear
6 SELECT SEARCH Search

STEPS 1 THROUGH 6

E-Notifications - Compliance Submission

Type CSN
Document Number 92-063
AIR CONDITIONING - Compressor Pallet Assembly, Dual Compressor
Subject Version, Replacement of

Owner/Operator ANY Helicopters


Submitted By ANY User
Submission Date Feb 13, 2011
Authorized By * ENTER NAME HERE 7

Compliance Date * ENTER COMPLIANCE DATE 8


Compliance Status Select * SELECT DOC STATUS 9
920013
920014
920018
Serial Number 920022
920024
* SELECT SERIAL NUMBER 10
Select the aircraft that this compliance will apply to.
HINT: Hold the CTRL button to select multiple items.

Submit Cancel
11 SELECT SUBMIT

STEPS 7 THROUGH 11
TD2394

GUIDE FOR E-NOTIFICATION COMPLIANCE


FIGURE 1.

April 28/11 Page 6 52-31-01


EMAIL ADDRESS: GPSIKSASProductSafet@utc.com

ATTENTION: SAS PRODUCT SAFETY MANAGER


SIKORSKY AEROSPACE SERVICES

Upon COMPLIANCE with the attached CSN, Sikorsky requests your cooperation in
completing and returning this ENTIRE PAGE by MAIL, FAX, or scan & EMAIL.

No. 92-085

DOORS - Perform a One-Time Modification to Prevent Chafing in the

Ramp Control Panel


BUSINESS REPLY MAIL

MAILSTOP: S328A
SAS PRODUCT SAFETY MANAGER
SIKORSKY AEROSPACE SERVICES

Or scan and email to:


EMAIL ADDRESS: GPSIKSASProductSafet@utc.com
Service Bulletin Nº: ANN-S92-006
E.O Associated: S92-222631 & S92-221247
Rev /
Date: Dec/22/2010
Revision: /
Page: 1 of 24

SERVICE BULLETIN DATA

ATT RAMP CONTROL PANEL


REWORK

S.B. Nº: ANN-S92-006


E.O. associated: EO S92-222631Rev/ & S92-221247 Rev/
This document details the incorporation of a modification, which has been deemed necessary to
retrofit or rework to S92A ramp control panel P/N 92550-03801-101 already delivered to
SIKORSKY/OPERATORS.

1. PLANNING

A. REASON

In order to prevent wire chafing, the wire bundles will be retrofitted to avoid the contact
with any element in the control panel such as rivets or walls.

B. DESCRIPTION - TIME FOR ACCOMPLISHMENT

(1) DESCRIPTION

This service bulletin describes the procedure to perform the necessary modifications to
avoid the ramp control panel internal cables chafing, and so, malfunctions in the ramp
control panel. In case that evidences of cable chafing are encountered during the
accomplishment of this service bulletin, repair following the instructions also included
herein.

(2) TIME FOR ACCOMPLISHMENT

Implementation of this Service Bulletin at operator’s discretion

C. APPROVAL

The design change affected by this document is FAA approved in accordance with
applicable requirements of Federal Aviation Agency (FAA) regulation FAR29.

Aernnova Aerospace
THE INFORMATION CONTAINED HEREIN INCLUDES TRADE SECRETS OF AERNNOVA AEROSPACE AND IS PRIVILEGED,
CONFIDENTIAL AND PROTECTED UNDER COPYRIGHT LAWS. THIS INFORMATION MUST NOT BE COPIED OR USED IN ANY
WAY WHATSOEVER EXCEPT AS EXPRESSLY AUTRHORISED IN WRITING BY AERNNOVA AEROSPACE. THIS DOCUMENT MUST
BE RETURNED TO AERNNOVA AEROSPACE ON DEMAND.
Service Bulletin Nº: ANN-S92-006
E.O Associated: S92-222631 & S92-221247
Rev /
Date: Dec/22/2010
Revision: /
Page: 2 of 24

SERVICE BULLETIN DATA


D. ESTIMATED MANPOWER

Disassemble: 1 Hr.
Modification: 2 Hr.
Assemblage : 1 Hr
Testing: 1 Hr

E. TOOLING - COST AND AVAILABILITY

GENERAL PURPOSE OHMETER TO CHECK CONTINUITY


MEGOHMMETER CA6521 CHAUVIN ARNOUX OR EQUIVALENT CAPABLE
OF MEASURING MORE THAN 50 MΩ OF INSULATION RESISTANCE AT
500VDC. (See Section 3.- ACCOMPLISHMENT INSTRUCTIONS, Part B.
PROCEDURE, Repair)
EXTRACT-AND-INSERT-PIN TOOL. REFERENCES: RAYCHEM M81969/14-10
AND M81969/14-11. (See Section 3.- ACCOMPLISHMENT INSTRUCTIONS, Part
B. PROCEDURE, Repair).
PHILIPS SCREWDRIVER.
CABLE TIE GUN (UNEX 2200 or equivalent).

F. WEIGHT AND BALANCE

Change in basic weight: Negligible.


Change in basic moment: Negligible.

G. REFERENCES

“Maintenance Manual, SA S92A-AMM-000”


“Ground Support Equipment, SA S92-GSE-000”
Maintenance Engineering Analysis SAC-S92-MEA-RAS-0001- Issue 5, Dated April
2010.

H. AFFECTED PUBLICATIONS

Not applicable

Aernnova Aerospace Proprietary Information - Use or disclosure of this information is subject to the restriction on the title page
Service Bulletin Nº: ANN-S92-006
E.O Associated: S92-222631 & S92-221247
Rev /
Date: Dec/22/2010
Revision: /
Page: 3 of 24

SERVICE BULLETIN DATA


2.- MATERIAL

PART I
Ramp control panel S/N C001 to C006, C320-00007 to C320-00022, B320-00023 to
B320-00051, B320-00053 to B320-00060, B320-00063, B320-00065, B320-00066, B320-
00070 to B320-00077, B320-00079 and B320-00080.

KIT P/N 92200-03070-011


P/N DESCRIPTION QTY. NOTES
UNEX 1257 POLYAMIDE ANGLE MOUNTING FIXING 1 N/A
UNEX 2221 POLYAMIDE CABLE TIES 3 N/A
RAYCHEM TFE-R 1/4 HEAT SHRINKABLE SLEEVE 1 N/A

PART II

Ramp control panel S/N C001 TO C006, C320-00007 TO C320-00022, B320-00023 TO


B320-00177, B320-00179, B320-00181 TO 00188, B320-00190 AND B320-00191.

KIT P/N 92200-03070-013


P/N DESCRIPTION QTY. NOTES
UNEX 1256-9 BRACKET 1 N/A
UNEX 2221 POLYAMIDE CABLE TIE 2 N/A
PEMSA 91022060 SPIRAL TAPE 1 N/A
RAYCHEM TFE-R 1/4 HEAT SHRINKABLE SLEEVE 1 N/A

CONSUMABLES [1]
P/N DESC QTY NOTES
Low-Lint Cleaning Cloth A-A-59323 1 -
Alcohol Alcohol A/R -
WEICON EASY-MIX S
or
HYSOL EA9309.3NA BICOMPONENT EPOXY ADHESIVE A/R [2]
or
HYSOL EA 934NA

NOTES

[1] LOCAL PROCUREMENT, NOT SUPPLIED.

[2] EQUIVALENT FAST-CURING BICOMPONENT EPOXY ADHESIVE ALSO ACCEPTABLE.

A/R = As Required

Aernnova Aerospace Proprietary Information - Use or disclosure of this information is subject to the restriction on the title page
Service Bulletin Nº: ANN-S92-006
E.O Associated: S92-222631 & S92-221247
Rev /
Date: Dec/22/2010
Revision: /
Page: 4 of 24

SERVICE BULLETIN DATA


3.-ACCOMPLISHMENT INSTRUCTIONS

A. JOB SET-UP.

10. Make sure that the aircraft is safe for maintenance.

B. PROCEDURE.

Disassembly

20. Remove ramp control panel . AMM-000-52-31-01.

Ramp control panel cable inspection

30. Remove ramp control panel cover plate. See FIGURE1FIGURE1

40. Visually inspect the wires to search for damaged wires and proceed as follows:

1. If a minor damage is found in the sleeves of wiring proceed with Repair (step 50)
2. If a major damage is found (beyond the limits of the repair procedure shown in
section “Repair”), replace unit.
3. In case no damaged cables are found, continue with the modification (step 100).

Repair

50. Release one end of the damaged wire from the connectors end (not the switches end). Use
the pin extractor M81969/14-10 for J2 or J3 and M81969/14-11 for J1 connector. See
FIGURE1FIGURE2

60. Repair the wire by protecting the damaged zone using a heat shrinkable sleeve.

70. Reinstall the extracted pins in their corresponding locations. Gently pull the wire to make
sure that the pin was inserted properly. See FIGURE1FIGURE2

80. Using FLUKE 189 MULTIMETER check continuity between the following pins :

STEP PINS CHECK


1. Pin A connector J1 & Pin A connector J3 <2
2. Pin B connector J1 & Pin B connector J3 <2
3. Pin C connector J1 & Pin C connector J3 <2
4. Pin D connector J1 & Pin D connector J3 <2
5. Pin E connector J1 & Pin E connector J3 <2
6. Pin F connector J1 & Pin F connector J3 <2

Aernnova Aerospace Proprietary Information - Use or disclosure of this information is subject to the restriction on the title page
Service Bulletin Nº: ANN-S92-006
E.O Associated: S92-222631 & S92-221247
Rev /
Date: Dec/22/2010
Revision: /
Page: 5 of 24

SERVICE BULLETIN DATA


90. Check that the switches are positioned according to FIGURE1FIGURE1: crew ramp switch
(702) in the centre position, Cargo light switch in OFF position and Baggage light switch in
OFF position. Using megohmmeter CA6521 check insulation resistance above 50 MΩ
between the following pins (only blank cells).

Connector J1 Connector J2 Connector J3


A B C D E F A B C D E F G H K A B C D E F
Case of connector - - - - - - - - - - - - - - -
A - -
Connector J1

B - - -
C - - - -
D - - - - -
E - - - - - -
F - - - - - - -
Case of connector - - - - - - - - - - - -
A - - - - - - -
B - - - - - - - -
Connector J2

C - - - - - - - - -
D - - - - - - - - - -
E - - - - - - - - - - -
F - - - - - - - - - - - -
G - - - - - - - - - - - - -
H - - - - - - - - - - - - - - -
K - - - - - - - - - - - - - - -
Case of connector - - - - - - - - - - - - - - -
A - - - - - - - - - - - - - - - -
Connector J3

B - - - - - - - - - - - - - - - - -
C - - - - - - - - - - - - - - - - - -
D - - - - - - - - - - - - - - - - - - -
E - - - - - - - - - - - - - - - - - - - -

Modification

PART I KIT P/N 92200-03070-011

100. Install the angle mounting fixing UNEX 1257 at the closest screw of the connector J1 to the
cargo light switch. See FIGURE3.

PART II KIT P/N 92200-03070-013


110. (This step only for Ramp Control Panel S/N B320-00081 and on). Remove and discard all
three existing cable ties from the bundles that join the connectors J1, J2, J3 to the panel
switches.

Aernnova Aerospace Proprietary Information - Use or disclosure of this information is subject to the restriction on the title page
Service Bulletin Nº: ANN-S92-006
E.O Associated: S92-222631 & S92-221247
Rev /
Date: Dec/22/2010
Revision: /
Page: 6 of 24

SERVICE BULLETIN DATA


120. Cut a section of spiral tape as long as required in order to install it around the bundle of
cables that connects terminals J1 and J3 and wrap around the bundle of wires (ref. 5.90 in.
long). See FIGURE3 and PHOTO 1.

130. Cut a section of spiral tape as long as required in order to install it around the bundle of
cables that connects terminal J2 and panel switches and wrap around the bundle of wires.
(ref. 11.02 in. long). See FIGURE3 and PHOTO 1.

140. Cut a section of spiral tape as long as required in order to install it around the bundle of
cables that connects ramp control switches and cabin light switches and wrap around the
bundle of wires (ref 3.54 in. long). See FIGURE3 and PHOTO 1.

150. Clean the back wall using alcohol.

160. Bond the bracket to the back wall using the epoxy adhesive following the manufacturer’s
instructions before proceeding to next step. See PHOTO 2.

170. Clamp both bundle of cables previously protected with spiral tape to the bracket on the
back wall using cable tie. See FIGURE3 and PHOTO 3.

180. Using cable tie, clamp the bundle of cables that connects terminal J2 to panel switches at
the angle mounting fixing UNEX 1257 on connector J1. See FIGURE3.

190. Install the ramp control panel cover plate. See FIGURE3.

200. Using FLUKE 189 multimeter do the following checks. FIGURE 2

STEP PROCEDURE
7. Position Crew ramp switch (S702) in the centre position
8. Check that there is continuity between pins H and K of the connector J2
9. Check that there is not continuity between pins F and E of the connector J2
10. Check that there is not continuity between pins F and G of the connector J2
11. Position Crew ramp switch (S702) in the lower position (down)
12. Check that there is not continuity between pins H and K of the connector J2
13. Check that there is continuity between pins F and E of the connector J2
14. Check that there is not continuity between pins F and G of the connector J2
15. Position Crew ramp switch (S702) in the raise position (up)
16. Check that there is not continuity between pins H and K of the connector J2
17. Check that there is not continuity between pins F and E of the connector J2
18. Check that there is continuity between pins F and G of the connector J2
19. Position Cargo light switch (S700) in OFF position
20. Check that there is not continuity between pins A and B of the connector J2.
21. Position Cargo light switch (S700) in ON position

Aernnova Aerospace Proprietary Information - Use or disclosure of this information is subject to the restriction on the title page
Service Bulletin Nº: ANN-S92-006
E.O Associated: S92-222631 & S92-221247
Rev /
Date: Dec/22/2010
Revision: /
Page: 7 of 24

SERVICE BULLETIN DATA


22. Check that there is continuity between pins A and B of the connector J2.
23. Position Baggage light switch (S701) in OFF position
24. Check that there is not continuity between pins C and D of the connector J2.
25. Position Baggage light switch (S701) in ON position
26. Check that there is continuity between pins C and D of the connector J2

Re-identification

210. Mark number 6 on the nameplate in the first space of the field “mods”. If number 5 is
marked, cross out and mark number 6.

Assemblage and testing

220. Install ramp control panel . AMM-000-52-31-01.

230. Perform Ramp Control Panel test. AMM-000-52-31-00.

240. Perform Cargo light test. AMM-000-33-45-00.

250. Perform Baggage light test. AMM-000-33-31-00.

C. JOB CLOSE-OUT

260. Return the helicopter to normal condition.

Aernnova Aerospace Proprietary Information - Use or disclosure of this information is subject to the restriction on the title page
Service Bulletin Nº: ANN-S92-006
E.O Associated: S92-222631 & S92-221247
Rev /
Date: Dec/22/2010
Revision: /
Page: 8 of 24

SERVICE BULLETIN DATA


5.- WEICON WORLWIDE SUPPLIERS

For full list of Weicon worldwide partners, visit the website: http://www.weicon.com

COUNTRY WEICON Importer


Angola GNS -Grupo Nunes da Silva-Comércio
Geral e Prestacao de Servicos, Ltd
C.P. 6838
Rua Comandante Bula 93-95
Luanda
Telefon: 0024422 2 430720
Fax: 00244 22 2 432010
e-mail: rdasilva@netangola.com.
Australia Ross Brown Sales Pty. Ltd.
P.O. Box 6345 BHBC
21 Brookhollow Avenue
Baulkham Hills, NWS 2153
Telefon: 0061 2 9899 2744
Fax: 0061 2 9899 4233
e-mail: grahamrb@bigpond.com
Bahrain Technologia Middle East WLL
Bdg. W10 & P10, Road No. 12
East Aluminium Building
712 Salmabad
Phone: +973 177 85860
Fax: +973 177 85668
e-mail: techno@batelco.com.bh
Belgium NV Metalen Galler
Italielei 22
2000 Antwerpen
Tel. 0032 3 231 46 00
Fax 0032 3 231 22 33
e-mai: jos.temmerman@metalengaller.be
S.A. Staelens N.V.
Rue des Critchons 2 à 26
B-4032 Liège (Chênée)
Tel. 0032 / 4 365 18 94
Fax 0032 / 4 367 06 18
e-mail: info@staelens-belgium.be
James Walker Belgium N.V./S.A.
Parc Industriel
B-5100 Naninne
Tel: 0032 81401321
Fax: 0032 81401323
e-mail: sales.jwn@jameswalker.be
Brasil Leidinger Repres. e.Servicos Ltda.
R.Salem Bechara
259-1 °andar - Centro
Osasco – Sao Paulo 06018-180

Aernnova Aerospace Proprietary Information - Use or disclosure of this information is subject to the restriction on the title page
Service Bulletin Nº: ANN-S92-006
E.O Associated: S92-222631 & S92-221247
Rev /
Date: Dec/22/2010
Revision: /
Page: 9 of 24

SERVICE BULLETIN DATA


Tel. + Fax: 0055 11 36994432
e-mail: leidinger@leidinger.com.br
Bulgaria Dimas Plast Ltd.
Office 404, 63 Shipchenski prohod Blvd.,
1574 Sofia
Tel: 00359 2 9789004
Fax: 00359 2 9783171
e-mail: d.dimitrov@dimasplast.com
Canada WEICON Inc.
20 Steckle Place
Unit 20
Kitchener, Ontario N2E 2C3
Phone: +1 519 896 5252
Fax. +1 519 896 5254
e-mail: k.juengel@weicon.ca
Chile Eurotecnica Ltda.
Lincoyan 973
Concepcion
Tel. 0056 41 253275
Fax. 0056 41 253276
e-mail: ricardogrob@eurotecnica.cl
China Deutschem Limited
Room 907, Silvercord Tower 2
30 Canton Road, TST,
Hong Kong
Tel. +852 - 2861 8712
Fax. +852 - 3007 3463
e-mail: bill@deutschem.com
Capelabel Tech. Co., Ltd.
Floor 12, Jinxin Building
Dongsanhuanbei Road
Chaoyang District
Beijing 100027
Tel. +86 10 84492018
Fax. +86 10 84492019
e-mail: lu@capelabel.com.cn
Croatia Tehno - Flex d.o.o
Slavonska Avenija 3
10000 Zagreb
Kroatien
Tel. +385 91 4488 750
Fax +385 1 6406330
Cyprus A & G Gearbyte Technologies Ltd.
Achilleos 7A,
3016 Limassol
Tel. +357 99681429
Fax +357 25565941
e-mail: info@gearbyte.com
Czech WEICON Safarik s.r.o
Republic Modlanská 1886

Aernnova Aerospace Proprietary Information - Use or disclosure of this information is subject to the restriction on the title page
Service Bulletin Nº: ANN-S92-006
E.O Associated: S92-222631 & S92-221247
Rev /
Date: Dec/22/2010
Revision: /
Page: 10 of 24

SERVICE BULLETIN DATA


41501 Teplice
Tel. 00420 417 562 000
Fax:00420 417 535 410
e-mail: info@weicon.cz
Denmark DanLube
Tune Parkvej 5
4000 Roskilde
Tel. 0045 70 25 12 80
Fax. 0045 70 25 12 30
e-mail: pc@danlube.dk, salg@danlube.dk
Egypt Aman Trading Co.
4 Mohamed El-Mahdy Str.
from Hussein Kamal Str.
Bohoth - Dokki - Giza
Cairo
Telefon: 0020 23 7481066
Telefax: 0020 23 7481066
e-mail: abdel-ahad@aman-eg.com
Estonia AS Weldest
Laki 16
10621 Tallinn
ESTONIA
Tel. 00372 6563 147
Fax 00372 6563 145
Faroe Islands KJ-Hydraulik
P/F K. Johannesen Maskinverkstadur
P.O. Box 110
530 Kambsdalur (Fuglafjördur)
Foroyar (Faroe Islands)
Tel. 00298 407000
Fax. 00298 407001
e-mail: info@kj.fo
Finland OY Impomet AB
Akerlundinkatu 6
FIN-33100 Tampere
Telefon: 00358 3 2393 2000
Telefax: 00358 3 2393 2022
e-mail: jukka.floor@impomet.com
France LIDERING S.A.R.L.
Parc des Aqueducs, Lot E
Chemin du Favier RD 42
F-69230 Saint-Genis-Laval
Tel. 0033 / 4 72670267
Fax 0033 / 4 78560408
S.A.R.l. SAFY
27 rue des Arènes
BP 535
89105 SENS Cedex
Tel. 0033 38664 0900
Fax. 0033 3 8664 0464

Aernnova Aerospace Proprietary Information - Use or disclosure of this information is subject to the restriction on the title page
Service Bulletin Nº: ANN-S92-006
E.O Associated: S92-222631 & S92-221247
Rev /
Date: Dec/22/2010
Revision: /
Page: 11 of 24

SERVICE BULLETIN DATA


e-mail: safy.achats@orange.fr
Grece Technoseal Poulitsis Bros Co.
74, Chrisostomou Smyrnis Str.
12131 Peristeri Athens
Tel. 0030 / 2 10 571 23 13
Fax 0030 / 2 10 577 14 81
e-mail: technoseal@vodafone.net.gr
Nikolaidis Konstantinos
Monastiriou 80
54627 Thessaloniki
Tel. 0030 /2 310513280
Fax. 0030 / 2 310 513280
e-mail: info@filtercosmos.gr
Efodiastiki S.A.
49, Doganis Str.
GR-185 46 Piraeus
Tel. 0030 / 2 10 4637 120
Fax: 0030 / 2 10 4637 075
e-mail: efodia@hol.gr
(mit Schwester-Fa. D. Kontrafouris + Co.,
Piraeus)
Greenland KJ-Hydraulik
P/F K. Johannesen Maskinverkstadur
P.O. Box 110
530 Kambsdalur (Fuglafjördur)
Foroyar (Faroe Islands)
Tel. 00298 407000
Fax. 00298 407001
e-mail: info@kj.fo
Guadeloupe VMA SAS
Z. I.. De Jarry
Impasse Georges Claude
97122 Baie-Mahault
Guadeloupe
Phone: 00590 590 367 317
Fax.: 00590 590 267 819
e-mail: vma@vanadoo.fr
Hong Kong Deutschem Limited
Room 907, Silvercord Tower 2,
30 Canton Road, TST
Hong Kong
Phone: +852 2861 8712
Fax: +852 3007 3463
e-mail: bill@deutschem.com
Hungary Ultima BT.
Nyerges-Köz 5
H-1181 Budapest
Tel. 0036 1 4328820
Fax. 0036 1 4328821
e-mail: info@ultima.hu

Aernnova Aerospace Proprietary Information - Use or disclosure of this information is subject to the restriction on the title page
Service Bulletin Nº: ANN-S92-006
E.O Associated: S92-222631 & S92-221247
Rev /
Date: Dec/22/2010
Revision: /
Page: 12 of 24

SERVICE BULLETIN DATA


India Stanvac Chemicals (India) Ltd.
15-16 Old Sewa Nagar Market
P.O. Lodhi Road
New Delhi - 110003 India
Phone: 0091 112 4647252
Fax: 0091 112 4623826
e-mail: sales@stanvac.com
Indonesia PT Charisma Tatamitra Abadi
JL. Ampera Raya No. 7,
Graha Ampera Lt. 6 No. 17
Gunung Sahari
Jakarta Utara
Tel. 0062 / 21 6451729
Fax 0062 / 21 6453089
e-mail: charisma@cbn.net.id
Iran Kolazhgostar Company
Add: No.28, Mowj Tower, Daryae noor Ave.
Tehran
Tel: +98 21 8 8501270
Fax: +98 21 8 8501270
e-mail: info@kolazhgostar.com
Ireland Workshop Direct
Unit 4 Lakelands Enterprise Centre
Athlone, Co. Roscommon
Telefon: 00353 909 673232
Fax: 00353 909 673104
e-mail: info@workshopdirect.ie
Iceland Fossberg Ltd.
Dugguvogi 6
104 Reykjavik
Tel. 00354 / 5757600
Fax. 00354 /5757605
e-mail: fossberg@fossberg.is
Israel Lomer Engineering Projects Ltd.
Omer Industrial Park
84965 Omer
Tel: 00972 8 6482826
Fax: 00972 8 6482424
e-mail: lomer@netvision.net.il
Italy Rarimport s.r.l.
Via Greto di Cornigliano, 6 R
I-16152 Genova
Tel. 0039 010 6502217
Fax. 0039 010 6502235
e-mail: info@rarimport.com
Japan Esco Co. Ltd.
8-14, 3-chome
Stachibori Nishi-Ku
Osaka

Aernnova Aerospace Proprietary Information - Use or disclosure of this information is subject to the restriction on the title page
Service Bulletin Nº: ANN-S92-006
E.O Associated: S92-222631 & S92-221247
Rev /
Date: Dec/22/2010
Revision: /
Page: 13 of 24

SERVICE BULLETIN DATA


Tel. 0081 6 65326226
Fax.0081 6 65410929
e-mail: esco-customer02@esco-net.com
Jordan Ismail Awad Trading Company
Import/Export/Adhesives
1111 P.O. Box 110039
Al Huriye Street
11118 Amman
Tel. 00962-6-4203078
Fax. 00962-6-4203108
Kuwait National Services Gen. Trading & Cont. Co.
Flex Bldg. - 11th Flr. Off.1118
P.O. Box 29260
Kuwait-Bneid- Al-Gar
13153 Safat
Phone: +9652 2515655
Fax. +9652 2521131
e-mail: enquiry@nsgtcc.net
Latvia Ignera Sia
Skaistakalnes 1
1004 Riga
LATVIA
Contact: Vjaceslav Babahins
Telefon: +371 7805158
Telefax: +371 7805159
e-mail : vjaceslavs.babahins@ignera.lv
Lebanon Sogiva Liban
Engineering S.A.L.
B.P. 1782 Jdeideh El Metn
Al Fanar - Beyrouth
Telefon 1: 00961 3 759101
Telefon 2: 00961 1 873120
Telefax: 00961 1 894469
e-mail: sogiva@cyberia.net.lb
Lithuania UAB Ignera
Draugystes g.19
51230 Kaunas
LITHUANIA
Telefon: 00370 37 353515
Telefax: 00370 37 352908
E-Mail : ignera@ignera.lt
web: www.ignera.lt
Luxemburg Neuberg S.A. Luxembourg
E.I.S.-Verband
Rue Jacques Stas, 39
2549 Luxembourg-Gasperich
Tel. 00352 / 401 401
Fax 00352 / 402 120
e-mail: info@neuberg.lu

Aernnova Aerospace Proprietary Information - Use or disclosure of this information is subject to the restriction on the title page
Service Bulletin Nº: ANN-S92-006
E.O Associated: S92-222631 & S92-221247
Rev /
Date: Dec/22/2010
Revision: /
Page: 14 of 24

SERVICE BULLETIN DATA


Auto Parts Luxembourg
APL
70, rue de Cessange
1320 Luxembourg
Tel.: 00352-481-811
Fax: 00352-491-103
E-Mail: marcel.frast@apl.lu
Macedonia Profi Mont
ul. Pelisterska br. 4
1000 Skopje
Tel. 00389 2 3223 930
Fax. 00389 2 3223 289
vlatko.krstevski@gmail.com
Morocco D.L.N. Equipement s.a.
115, Rue Senhaja la Vilette Khalil 1
Casablanca
Telefon: 00212 22 60 27 71
Telefax: 00212 22 62 53 85
d.l.n.equipement@menara.ma
Nederlands Festec Trade
Industrial Supplies B.V.
Mandenmarkerstraat 78
NL-3194 DG Rotterdam Hoogvliet
Tel. 0031 10 298 20 20
Fax:0031 10 298 20 21
e-mail: trade@festec.nl
New Zealand Ross Brown Sales (NZ) Limited
4 William Pickering Dr.
Albany, Auckland
Telefon: 0064 9 415 4111
Telefax: 0064 9 415 4112
e-mail: rbz@ihug.co.nz
R.A. Johnstone & Co. Ltd.
P.O. Box 97948 S.A.M.C.
Wiri, Auckland
Telefon: 0064 9 261 0333
Telefax: 0064 9 261 0330
cameron@raj.co.nz
Nepal See India
Norway Nofitek A.S.
Postboks 6586 Hatlane
NO-6022 Alesund
Tel. 0047 / 70 19 94 40
Fax 0047 / 70 19 94 50
e-mail: harald.haabet@nofitek.no
Oman WEICON Middle East LLC.
P.O. Box 118216
Jebel Ali Industrial Area No. 3
Dubai

Aernnova Aerospace Proprietary Information - Use or disclosure of this information is subject to the restriction on the title page
Service Bulletin Nº: ANN-S92-006
E.O Associated: S92-222631 & S92-221247
Rev /
Date: Dec/22/2010
Revision: /
Page: 15 of 24

SERVICE BULLETIN DATA


Tel. 00971 4 8802505
Fax 00971 4 8802509
e-mail: t.lutz@weicon.ae
Peru Adtech & Service E.I.R.L.
Chalcuchimac 357 Urb.
Salamanca de Monterrico ATE
Lima
Tel. +51 1 4354076
Fax.+51 1 4344927
e-mail: jdelacruz@adtechservice.com
Philippines Euro Advance Solutions & Systems Ind.
No. 96 A Dona Soledad
Ave., Better Living
Bicutan, Paranaque City
Tel. 00821 9608 821 9490
Fax. 00821 9342 821 9183
e-mail: euro-advance@pacific..net.ph
FUMAN Industries, Inc.
P.Remedio St. Cabancalan
6014 Paranaque City, Cebu
Phone. 006332 346 4530
Fax. 006332 346 1583
Poland CT-CARD Krzysztof Salwin
Farysa 15B
01-971 Warszawa
Tel. 0048 22 835 05 05 104
Fax: 0048 22 834 53 55
e-mail: i.poniedzialek@ct-card.pl
Portugal Intermaco
Arruamento "E"
Zona Ind. Apartado 88
3850 Albergaria -a-Velha
Tel: 00351 234 520 110
Fax:00351 234 520 119
e-mail: intermaco@intermaco.pt
Qatar Qatari Industrial Equipment
Mr. Lester Morgan Fernandes
P.O. Box 9377
Doha
Phone: +974 4 600044
Fax: +974 4 600041
e-mail: qieasp@qatar.net.qa
Romania S.C. PARCON SRL
Str. Depozitelor 22
4300 Targu Mures
Tel.: 030 662 3942
Fax: 030 661 7368
e-mail: weicon@parcon.ro
Russia Unit Mark Pro
Marksistskaya Str. 34/10

Aernnova Aerospace Proprietary Information - Use or disclosure of this information is subject to the restriction on the title page
Service Bulletin Nº: ANN-S92-006
E.O Associated: S92-222631 & S92-221247
Rev /
Date: Dec/22/2010
Revision: /
Page: 16 of 24

SERVICE BULLETIN DATA


109147 Moscow
Tel.. 007 095 748 0907
Fax 007 095 748 0909
e-mail: na@unit.ru
Saudi Arabia Industrial Machinery Est.
Post Box 907, Support Industrial
Area, Street 118, Block No. 4
Plot No.13, Opposite Fire Station
Jubail
Tel. +9663 341 7737
Fax.+9663 341 6305
e-mail. Office@indme.com
Siria See Lebanon
Slovakia ALTIS Slovakia s.r.o.
Milan Spiriak
Langsfeldova 3
03601 Martin
Slowakische Republik
Tel.: 00421 / 43 00530
Fax. 00421 43 4220258
e-mail: info@weicon-sk.sk
Slovenia Regeneracija d.o.o.
Kamniska cesta 47
Sl-1217 Vodice
Slowenien
Tel: 00386 4 5317070
Fax: 00386 4 5317070
e-mail: franc.cadez@regeneracija.si
South Africa Zonke Engineering
Block 14 Pinewood Office Park
33 Riley Road
2191 Woodmead
Tel.: 0027 11 234 1770
Fax. 0027 11 234 1772
e-mail: ian@zonkekzn.co.za
Spain Lidering S.A.
Est. Avanzada
Pg.Ferrocarrils Catalans,106-108
08940 Cornella de Llobregat/Barc.
Telefon: 003493 480 44 00
Telefax: 003493 480 44 04
e-mail: tecnic@lidering.es
Sri Lanka See India
Sweden VISAB
Odengatan 21
576 31 Sävsjö
Tel. 0046 / 382 135 00
Fax 0046 / 382 138 98
e-mail: vis.ab@telia.com

Aernnova Aerospace Proprietary Information - Use or disclosure of this information is subject to the restriction on the title page
Service Bulletin Nº: ANN-S92-006
E.O Associated: S92-222631 & S92-221247
Rev /
Date: Dec/22/2010
Revision: /
Page: 17 of 24

SERVICE BULLETIN DATA


Switzerland Karl Ernst AG
Generalvertretungen
Foerrlibuckstr. 110
8005 Zuerich
Telefon: 0041 44 271 15 85
Telefax: 0041 44 272 55 47
e-mail: info@karlernstag.ch
Taiwan SUN TOWARD TECH ENTERPRISE Co., Ltd
Enterprise Co., Ltd.
1F., No. 261,
Sanjia E. St., Beitun District,
406 Taichung City, R.O.C.
Tel. +886 4 24366 111
Fax. +886 4 24365377
e-mail: tw@msa.hinet.net
Thailand C.M.P. Supplies Ltd., Part.
20/1 Soi Ramkhamheang 16,2nd Branch
Ramkhamheang Road, Huamak Bangkapi
10240 Bangkok
Tel. +66 02 3190950
Fax. +66 02 7186356
e-mail: cmpgroup@compthai.com
U.A.E. WEICON Middle East LLC.
P.O. Box 118216
Jebel Ali Industrial Area No. 3
Dubai
Tel. 00971 4 8802505
Fax 00971 4 8802509
e-mail: t.lutz@weicon.ae
Ucraina ALS Ltd.
uliza V. Yana 3/5
01033 Kiev
Tel. +38044 3313640
Fax. +38044 2891391
e-mail: l.bayda@meta.ua
UK G.B. Chemical Solutions Ltd.
Unit 3, Black Brook Way
Stainland Road,
Greetland, Halifax,
West Yorkshire HX4 8ED
Phone: 0044 1422 378888
Fax : 0044 1422 370177
E-Mail : gbchemicals@btopenworld.com
USA Gulf Marine & Industrial Supplies Inc.
401 Saint Joseph Street
New Orleans, LA 70130
Tel. 001 504 525 6252
Fax.001 504 525 4761
e-mail: service @gulfmarine.net

Aernnova Aerospace Proprietary Information - Use or disclosure of this information is subject to the restriction on the title page
Service Bulletin Nº: ANN-S92-006
E.O Associated: S92-222631 & S92-221247
Rev /
Date: Dec/22/2010
Revision: /
Page: 18 of 24

SERVICE BULLETIN DATA


Vietnam Tin Duc Co. Ltd.
35-37, Yersin P.Col, Quan 1
Ho Chi Minh
Tel. +84 8 9144302
Fax +84 8 9143483
e-mail tinduc1@vnn.vn

6.-FIGURES & PHOTOS

See following pages

Aernnova Aerospace Proprietary Information - Use or disclosure of this information is subject to the restriction on the title page
Service Bulletin Nº: ANN-S92-006
E.O Associated: S92-222631 & S92-221247
Rev /
Date: Dec/22/2010
Revision: /
Page: 19 of 24

SERVICE BULLETIN DATA

FIGURE1 – GENERAL VIEW

Aernnova Aerospace Proprietary Information - Use or disclosure of this information is subject to the restriction on the title page
Service Bulletin Nº: ANN-S92-006
E.O Associated: S92-222631 & S92-221247
Rev /
Date: Dec/22/2010
Revision: /
Page: 20 of 24

SERVICE BULLETIN DATA

FIGURE2 – WIRING DIAGRAM


Aernnova Aerospace Proprietary Information - Use or disclosure of this information is subject to the restriction on the title page
Service Bulletin Nº: ANN-S92-006
E.O Associated: S92-222631 & S92-221247
Rev /
Date: Dec/22/2010
Revision: /
Page: 21 of 24

SERVICE BULLETIN DATA

FIGURE3 – ANGLE MOUNT


Aernnova Aerospace Proprietary Information - Use or disclosure of this information is subject to the restriction on the title page
Service Bulletin Nº: ANN-S92-006
E.O Associated: S92-222631 & S92-221247
Rev /
Date: Dec/22/2010
Revision: /
Page: 22 of 24

SERVICE BULLETIN DATA

PHOTO 1 - SPIRAL TAPE

Aernnova Aerospace Proprietary Information - Use or disclosure of this information is subject to the restriction on the title page
Service Bulletin Nº: ANN-S92-006
E.O Associated: S92-222631 & S92-221247
Rev /
Date: Dec/22/2010
Revision: /
Page: 23 of 24

SERVICE BULLETIN DATA

PHOTO 2 – BRACKET BONDING

Aernnova Aerospace Proprietary Information - Use or disclosure of this information is subject to the restriction on the title page
Service Bulletin Nº: ANN-S92-006
E.O Associated: S92-222631 & S92-221247
Rev /
Date: Dec/22/2010
Revision: /
Page: 24 of 24

SERVICE BULLETIN DATA

PHOTO 3 – BRACKET CLAMP

Aernnova Aerospace Proprietary Information - Use or disclosure of this information is subject to the restriction on the title page

You might also like