Professional Documents
Culture Documents
Feature Benefit
Perfect Reliable
– 100% factory tested
– Based on proven and tested filter concept
Maximum uptime
– Low failure rate
match for industrial
automation, Energy saving Lower operation costs
highly dynamic – High efficiency
applications and – Electrically matched to the individual – Low running expenses
safety installations VLT® frequency converters
Design Compact and aesthetic enclosure
– Innovative coil design – Smaller footprint
– Side-by-side mounting – Less wall space needed
– Optimised for mounting in panels
– Easy commissioning – Low commissioning costs
– Enclosure size and colour matches – Danfoss look and feel
drives.danfoss.com
Accessories Specifications
The following accessories are available: AHF 010 AHF 005
n IP21/NEMA 1 kit THiD* at:
– 40% load ~ 12% ~ 7%
n IP21/NEMA 1 kit with capacitor – 70% load ~ 11% ~ 6%
disconnect feature – 100% load < 10% < 5%
n Backplate for IP Efficiency* at 100% load >98.5%
20 enclosures True power factor* at:
– 40% load ~ 81% ~ 80%
– 70% load ~ 96% ~ 95%
– 100% load > 99% > 98%
Ambient temperature 45° C without derating
Harmonic
Calculation Software For enclosures rated IP20, back channel cooling
Cooling
With VLT® Motion Control Tool is built in.
MCT 31, you can determine whether
* Measured at balanced grid without pre-distortion
harmonics will have a detrimental Norms and recommendations Compliance
effect on an installation incorporating AHF 005 is compliant under all conditions
frequency converters. IEEE519 AHF 010 is compliant dependent on grid and
load conditions
IEC61000-3-2 (up to 16 A) AHF 005 and AHF 010
MCT 31 calculates system harmonic IEC61000-3-12 (between 16 and 75 A) AHF 005 and AHF 010
distortion. Then it estimates the IEC61000-3-4 (above 75 A) AHF 005 and AHF 010
benefits of implementing harmonic
mitigation, using filters available from Enclosures
Danfoss. Furthermore the software AHF current rating
provides quick indication of whether 380-415 V/ 380-415 V/ 440-480 V/ 600/ 500-690 V/ AHF
50 Hz 60 Hz 60 Hz 60 Hz 50 Hz enclo-
the installation complies with the most sure
AHF AHF AHF AHF AHF AHF AHF AHF AHF AHF
recognised harmonic norms and 005 010 005 010 005 010 005 010 005 010
recommendations. [A] [A] [A] [A] [A] [A] [A] [A] [A] [A] Type
10 10 10 10 10 10 – – – – X1
14 14 14 14 14 14
Download the MCT 31 software
22 22 22 22 19 19
free of charge at: 29 29 29 29 25 25 – – – – X2
www.danfoss.com 34 34 34 34 31 31 15 15 15 15
40 40 40 40 36 36 20 20 20 20 X3
55 55 55 55 48 48 24 24 24 24
66 66 66 66 60 60 29 29 29 29 X4
82 82 82 82 73 73 36 36 36 36
96 96 96 96 95 95 50 50 50 50 X5
133 133 133 133 118 118 58 58 58 58
77 77 77 77
171 171 171 171 154 154 87 87 87 87 X6
204 204 204 204 183 183 109 109 109 109
128 128 128 128
251 251 231 155 155
251 304 304 291 155 155
251 231 197 197 X7
304 325 325 355 197 197
381 381 380 240 240
304 291
325 296 296
325 355 240 240
381 480 480 436 366 366 X8
381 380 296 296
480 395 395
480 436
Dimensions
Enclosure type Height (*1) [mm] Width [mm] Depth [mm]
X1 347 190 206
X2 451 230 248
X3 605 378 242
X4 634 378 333
X5 747 418 333
X6 778 418 400
X7 900 468 450
X8 900 468 515
: Maximum dimension. The exact dimension depends on fan concept.
(*1)
For the exact dimensions, refer to the Design Guide Advanced Harmonic Filters.