Professional Documents
Culture Documents
ED7000EL
Integrated Elevator Controller
Page #
Accessories .............................................................................. 07
A simple and cost effective integrated solution for elevators speed up to 1.5 m/s simple and duplex
applications with closed loop geared and gear less PM machines 40 floors full collective using low cost
conventional parallel wiring.
Wide operating
voltage range
323 to 528 Vac
Design for Conventional
high ambient parallel wiring
temperature 40-floors
full collective
mode
Flexible In-Built
programmable Dynamic
I/O Braking
connection Unit
Enhanced
Duples reliability with
conformal coating,
onboard protection against
group humidity
control and pollution
dust
Selectable
door control
mode
ED7000EL integrated
elevator inverter
Key Pad
LFT-LCD-IPT
Synchronous or
asynchronous motor
ED7000EL 03
ITEM SPECIFICATION
Maximum frequency 99 Hz
Carrier frequency 2–16 kHz, adjusted automatically based on the load features
● Sensorless vector control (SVC)
Motor control mode ● Closed-loop vector control (CLVC)
● Voltage/Frequency (V/F) control
● 1:100 (SVC)
Speed adjustment range ● 1:1000 (CLVC)
● 1:50 (V/F)
● ±0.5% (SVC)
Speed stability accuracy
● ±0.05% (CLVC)
BASIC TECHNICAL SPECIFICATIONS - ED7000EL
Overload 60s for 150% of the rated current, 1s for 200% of the rated current
Direct travel ride mode in which the leveling position can be adjusted
Distance control
flexibly
Acceleration/
N curves generated automatically
Deceleration curve
Shaft auto-tuning 32-bit data, recording the position in the shaft accurately
Real-time clock for time-based floor service, peak service and automatic
Real-time clock
password
Intelligent management Remote monitoring, user management, and group control adjustment
Security check of
Security check of peripheral devices, such as grounding and short
peripheral devices after
circuit, after power-on
power-on
24 x DI
Input specification: 24 V, 5 mA
Digital input (DI) 3 heavy-current detection input terminals of safety circuit and door lock
circuit
Input specification: 95−125 V
I/O FEATURE
6 relay outputs
Output terminal block
The terminals can be allocated with different functions.
Connecting the control system and the host computer, convenient for
Status monitor
querying/motoring the system state.
IP level IP20
Power distribution
TN, TT
system
Model No. Rated Power (KW) Rated Output Current (A) Braking Unit Min. Braking Resistance
ED7000EL 05
06
Regen. resistor
Safety
contactor
+ – PB K1 Braking
Three-phase R mechanism
CN5 U Motor
AC power
voice
S K2
supply V M
announcer
PRG UP SET
T
W
0V
B
A
24V
Encoder Switch Power
(P≥150W)
CN12 Shield
0V 24V
+24 VDC
Up leveling J12 PG card
X1
Door zone X2 LFT-PG-GL/G CN10
Down leveling X3 24V
CN1 24V
Safety circuit feedback X4
CN7 CN8
CONNECTION DIAGRAM
CN1
24V
+24 VDC MOD+
Car top Emergency MOD-
inspection electric operation COM
1 2 1 2
X9 Inspection signal
Up
Inspection 3 4 1 2
common Up X10 Inspection up CN2
3 4 1 2 1 2
1 2
Down
X11 Inspection down LFT-LCD-IPT
1 2
Down
5 6 5 6
Short shaft
safety switches Note:
The functions of I/O terminals of the
LFT-HALL-IPT controller are set in group F5. The wiring in
this figure uses the default setting.
Bottom
floor
24V
MOD+ CN1
MOD-
COM
LFT-LCD-IPT
ACCESSORIES A wide rage of optional cards accessories are available for users to integrate with
existing elevator system.
Hardware Configuration:
5Vdc Supply, female 15-way D-type connector
Function Configuration:
Weton SinCos EI58C9.25/ERN1387 encoder
SinCos Encoder Card with C, D signals. Fitted to main control board. For
Model No.: LPT-PG-GL Gearless PM Motor.
Quadrature incremental encoders (A+, A-, B+, B-
signals 5VHTL). Fitted to main control board. For
Geared motor.
Hardware Configuration:
12Vdc Supply, terminal block connector
Asynchronous Encoder Card Function Configuration:
Terminal Block For incremental encoder, single ended (A,B).
Model No.: LPT-PG-G Fitted to main control board. Fitted to main control
board. For Geared motor.
Hardware Configuration:
8 digital signal input terminals, 9 relay output
Car Top Board terminals, 1 analogue voltage signal input
Model No.: LFT-CAN-IPT terminal, 1 onboard Rs485 and CAN
communication port, 2 parallel interface
expansion port.
Hardware Configuration:
3.5” ultra-thin vertical dual colour LCD. Blue
background with white letter.
LCD Display Board Function Configuration:
Model No.: LFT-LCD-IPT Travel UP & Down button indicator output,
directional dot-matrix output, over-load indicator,
double button control, hall call button input, fire
emergency input, lock input
Hardware Configuration:
24 digital input terminals, 20 digital output
terminals.
Car Call Board Function Configuration:
Model No.: LFT-HALL-IPT 16 floor buttons and 8 functional delay, non-stop
mode, attendant mode, reversing direction,
independent mode, fireman mode, arrival gong
signal output.
ED7000EL 07
ELEVATOR CONTROL PANEL SOLUTION
Item Requirements
Ambient
-10°C to 50°C
temperature
Install the controller on the surface of an incombustible object, and ensure that there is
Heat dissipation sufficient space around for heat dissipation.
Install the controller vertically on the support using screws.
The controller must be installed inside a cabinet. The final system installing the
Protective Enclosure controller must have covers providing fire, electrical, and mechanical protection, and
satisfy the regional laws & regulations and related IEC requirements.
SAFETY MEASURES
Strong vibration
Vibration less than 0.6 g
Dust, oil Sunlight
ED7000EL 09
POWER TECH
Branch Office:
S.I.T.E Trade Center, Plot # D-59.SITE Karachi near Naseer Autos, ghani churangi, site Karachi.
Mob: +92 308 444 2072, +92 308 444 2073
Email: marketing.khi@inventpowertech.com, service.khi@inventpowertech.com