Why is energy

efficiency important

There are a number of reasons why you should and often the most immediate way to reduce the
consider reducing your energy consumption... use of fossil fuels. There are huge opportunities
In turn, saving energy produces a better quality of for efficiency improvements in every sector of the
life. Reducing emissions translates into cleaner economy, be it power generation, transmission
air quality. Plus, it helps create a healthier planet, grids, data centres, industrial process cooling.
or at least helps sustain the resources we already
have. Frigel has taken up this challenge with the aim
of making a concrete contribution by designing
The most important step in moving away from a new generation of ECODRY: LDK, the most
high energy consumption and towards a better effective adiabatic coolers available today.
climate balance is to increase energy efficiency
rather than just saving it. The use of this new technology helps to
significantly reduce the consumption of electricity
Energy efficiency simply means using less in relation to the cooling capacity required.
energy to accomplish the same task, which is An extensive list of benefits makes LDK an
to eliminate wasted energy. While renewable unbeatable solution to the ecological challenges
energy technologies also help achieve these of the present and future.
goals, improving energy efficiency is the cheapest

1
9000 Better cooling
The Most Efficient
installations worldwide performance

Adiabatic Cooler Outstanding New standards


operating cost savings in terms of environment impact
Ecodry LDK at glance

XDK tower LDK MDK 3DK

Heavy Duty

Wide & Deep

New Standard

Existing
product

Up to 2,8 MW per unit in adiabatic mode Modular System Design - Wide and Deep

Up to 1,8 MW operating in dry mode per unit From Dry - Spray - Adiabatic to Hybrid
technology Power Process Data Ind. Beverage Plastic
Cooling center HVAC

2 3
Toward more efficient Dry Spray Adiabatic Hybrid
Heat Rejection
The natural choice over evaporative cooling towers

Cooling Tower ECODRY - LDK


Conditions Δt= 10 K
High water consumption Almost no water consumption
Uses water evaporation as cooling source Only uses water evaporation at peak ambient
throughout the year. Also dumps high volumes conditions. Otherwise, it works completely
of water to reduce salt concentration caused
by evaporation.
dry, reducing water consumptionup to 95%.
BENEFITS

Contaminated water to process Always clean water to process


Permanently contaminates water (physically, Close loop circuit and no stagnant water
chemically and biologically) with the pollution results in pre-treated water that will be kept Advanced software provides the Climatic conditions at the site
taken from the surroundings air. perfectly clean and uncontaminated. solution for your application
and optimizes it for required Yearly ambient temperature profile
operation in the plant. Expected process loads
Causes machine overheating Constant efficiency heat transfer
Permanent fouling and scaling dramatically Assures always constant heat transfer with no
decreases machine heat exchanger efficiencies. fouling or scaling of surfaces.

Requires permanent chemical treatment No ongoing chemical treatment


needed
ADVANTAGES
Requires specialized ongoing water treatment
with chemical additives, permanent filtration Process water only needs a chemical pre-
and automatic purging, resulting in high treatment and periodic monitoring. No Ecodry
consumption of additives. consumption or bleed-off of chemicals. + not good ++++ Very good Cooling tower Adiabatic
LDK
Open Closed
Expensive maintenance Low maintenance costs
Minimized water consumption + + ++ +++
Requires specialized ongoing water treatment Does not require any periodic maintenance
with chemical additives, permanent filtration for cleaning of heat exchanger surfaces. Energy Efficient Fan operation ++ ++ +++ ++++
and automatic purging, resulting in high Only a periodic monitoring of water quality is
consumption of additives. suggested.
No blowdown ++ +++
Reduced costs No areosol and or plumes + + ++++ ++++
Total savings may be estimated in 80 to 95%.
Clean water to process standard + + ++++ ++++
Stainless Steel 304 STD + + ++ ++++
Risk of bacterial diseases No risk of Legionella
It may be the source of dangerous bacterial System runs completely dry at least once a day, Investment costs ++ +++ ++ +++
diseases (Legionella) grown in the water and for several hours. Not enough time to develop
Low maintenance + + ++ ++++
spread by drift. any kind of organic growth.
Operating costs + + +++ ++++

4 5
Industrial fans Booster system

ECODRY LDK Designed for severe Duty and


corriosion resistant
high Direct spray cooling for extreme hot
ambient temperatures

the industrial choice Airflow And Noise Tested on laboraty


and verief on the field
Heat dissipated by evaporation
No scaling on coil surface
Unique fan blade design performed Areosol free operation
trought CFD analsyys Monitored by intelligent control system

Advanced motor technology (EC)


The highest efficiency solution
Zero maintenance
Integrated ModBus communication
0-10V signal
Safety switch on each fan

Single point power connection


Drive by wire
All motors factory wired
PLC integrated ModBus protocol
0-10V signal

V-Coil heat exchangers


Multiple tube configurations for closed
circuit operation
Self-draining for water systems in
freezing climates
Copper tubes with SS304 or 316 available
Alu magnesium (Almg 2.5) fins
Hydrofin, ideal for spray coolers

V-Coil heat exchangers Rugged construction CoolPad


Floating system of the array (and pipes!) Stainless steel 304L for increased Internationally patented adiabatic
which reduces mechanical and thermal corrosion resistance and life span chamber
stresses High corrosion class available as a Water drift preventive design
standard configuration Flame–retardant material
Exceptional cooling and humidification
rates
GreenGuard gold certified

6 7
LDK – achieves the customer Always maximum performance and
efficiency
Multiple logics based on customer
needs

needs by intelligent controls Benefits: Benefits:


Reduced water and energy consumption Best control based on customer
Achieves the best $/kW cooling possible, requirements
second by second All logics have been developed after a
deep computational analysis
Stand alone control Ready for cooling plant integration Features:
Cooling power driven by Ambient and Features:
Benefits: Benefits: Inlet/Outlet Temps., read second by Water saving mode control
Complete redundancy by machine Complete control of complex cooling second Power saving control mode
Fully integratable for existing systems systems thanks to 3PR 4.0

Features: Features:
0-10V control Main control panel for LDK, Pumping
Modbus RTU control Stations, Chillers and Free Cooling
Logic driven by integrated electronic based on logic, tested since ‘90
boards

Always connected Multiple coil configurations

Benefits: Features: Benefits: Features:


Modbus communication C = standard version for glycol and
Fully supervised by remote Suitable for all the plant configurations
MiND Frigel supervision pressurised systems
Online service operations to reduce Suitable for multiple needs
D = simplified self-draining
intervention time
S = full-self draining system (no glycol
even with Ambinet Temps. < 0°C (32°F)

8 9
The ultimate cooling
solutions
Water Saving Power Saving
Adiabatic system in hot season.
Outside air passes across the CoolPad.
Here the ultimate design of the
patented CoolPad gives the best
humidification and cooling air: the
efficiency boosts overall performance

DRY ADIABATIC BOOSTER


MODE MODE MODE
Dry operation in cold weather. The Only in extremely high weather
external air is conveyed directly to the conditions, when ADIABATIC MODE is
heat exchanger. not enough to keep the leaving water
CoolPad system is deactivated in
free air intake position. Air flow is
temperature within a predefined
setpoint, the booster mode is
choose for each step how much energy or water you can save
modulated according to temperature. automatically activated entering into
Energy savings and water savings are hybrid functionality
the results.

Dry Adiabatic Hybrid

10 11
Dry & Adiabatic CoolPad™
Cooling EFFICIENT – SUSTAINABLE AND PATENTED
The unique design gives it a high strenght and durability with exceptional cooling and
humidification rates.

Benefits Savings
Reduced maintenance
Greater efficiency
Long lasting performance Corrosion, scaling and bacteria concerns
are eliminated with the CoolPad system.
Recyclable at end of life
The ECODRY LDK series keeps the
Higienic rules compliant
reduced maintenance by the design with
Minimized operating costs best-in-class materials.

Performance and reliability Water consumption


An intelligent system keeps the Comparing the traditional evaporative
adiabatic chamber in humidified solutions, ECODRY LDK series and the
conditions for long periods, thanks to new CoolPad reduces or eliminates water
Frigel’s patented pulse cycle system consumption. Adiabatic mode is activated
that minimizes water consumption. only when required by ambient conditions.
CoolPad, managed by the Frigel Netgel
Algae and weather resistant
control package, maximize water
Prevents bacterial proliferation conservation and /or energy consumption
Scrubbable to extend service life thanks to advanced and friendly
Reinforced flame-retardant material proprietary control logic.
GreenGuard Gold certified*

How it works Engineering made easy


CoolPad is a modular pre-assempled
The finned pack heat exchangers can this property provides for a pre-cooling of package for easy on-site assembly.
dissipate the heat of the thermal process into the air entering the finned heat exchanger, With NetGel intelligent control
the ambient air by convection with a precise effectively increasing the heat transfer management, all fundmental functions
Dry temperature gradient derived from the capacity of the process. The adiabatic and settings are monitored constanly,
design of the machine (exchange surfaces chamber, placed before the finned heat thus providing a complete program of
and the air flow of the fans). The parameters exchanger, performs the work of humidifying yearly maintenance in advance.
involved are the temperatures of the fluid the air to obtain the desired pre-cooling.
and that of the dry bulb of the ambient air. The patented Frigel system is not only very
The ambient air is a mixture of gas and efficient in reaching humidification values
humidity and has an interesting physical close to saturation but is able to be very
property: by increasing the value of the reactive in humidity regulation and in the
humidity present in the environment, a ability to transfer only the amount of water
variation of the dry bulb temperature value necessary for pre-cooling without any
is obtained on the isenthalpic line A-B up to unnecessary waste. *
GreenGuard Gold means the chemical emissions from the materials
the limit of the saturation value. Actually, are extremely low. This means that CoolPad is an environmentally
friendly design and safe to use in any application.

12 13
Highlights

01 02 03 04
Proven Lowest Total Cost Clean Water Free Cooling
Performance of Ownership to Processes Opportunities

9000 Cooling tower TCO average


Breakdown
Close loop circuit guarantees constant
uncontaminated clean water to
The system may have the ability to
automatically replace, partially or totally,
Installations End of life process the thermal loads of existing “mechanical
refrigeration systems” operating as a
1% No surface fouling, constant efficiency
GLOBALLY drycooler during winter time.
of heat exchange with processes
Minimal ongoing chemical treatment
Capital
With more than 9000 systems installed and required
4%
running in all climate conditions and in a
vast range of process applications, Ecodry 95%
is, by far, the most proven Adiabatic Cooler
worldwide.

Water Savings Energy Savings Maintenance Cost Savings


Minimized Water Reduced Operating Chemicals and water treatment up to -95%
Footprint up to -95% Costs up to -40%
High humidification efficiency of Unbeatable efficiency with Minimal ongoing water treatment required
sprayed mist of water in the “adiabatic Electronically Commutated (EC) fans No risk of coil corrosion and scaling
chamber” as standard Extended life of humidifying pads thanks to water nebulization
Lower approach to WB of pre-cooled Reduced air pressure drops through Extended legs to avoid dust intake
air with less water usage thin pad design Maintenance-free fan motors
Proven performance in extreme Reduced power consumption and Easy access for cleaning of coils and adiabatic chamber
weather conditions, up to +50°C noise emissions with exhaust diffusers
(+120°F) Easy removal of panels during DRY
Intelligent Management System operation (winter)
adjusts the lowest water consumption Less pumping energy consumption
according to actual conditions thanks to low coil pressure losses

14 15
Highlights 07
Glycol FREE
Operation
05 06 100% reliability in extreme climate
Total Modularity, High density and conditions, down to -40°C (-40°F)

High Reliability compact design Unique Frigel self-draining design by


gravity
Easy to expand at any time to meet 45% less footprint requirement Complete set of sensors and anti-
growing needs from Dry - Spray - thanks best optimized air intake freezing software
Adiabatic to Hybrid configuration Maximized performance and Special manifolds ensuring fast and
Electrical redundancy with individual minimized footprint full draining
fan power plugs Reduced installation costs
Modular system design - wide range No air flow recirculation between
of options configurable units
Hygienic, safe operation 3 to 7 High Extra large heat exchanger surfaces
efficiency EC fan packages High level of static stability
Coils with copper or SS tubes Optimized dimensions
Multiple coil configurations for any
cooling demand
Safe protective coil system integrated
for any duty
Rigid structure, resistant to deflection

16 17
11
Highlights Free-Cooling Opportunities
CFD has become a powerful instrument in

08 the hands of design and R&D engineers.


With specific expertise in the fields of
Spray System fluid dynamics and heat transfer, CFD can
provide a strong acceleration to the design
Cooling solution tailored for your process. process of cooling systems and can help to
LDK- SC is a freeze-proof solution that guarantee high production efficiency. This
combines dry air cooling during the cooler is how Frigel has exploited the benefits
Heat exchanger optimization
months of the year with spray cooling during of CFD for the design of its LDK adiabatic
the warmer months. cooling system.
With the closed-loop system, intelligent
controls and rugged design, the LDK SC is an
efficient, flexible and sustainable approach
to process cooling.

10 Increased coil surface area automatically


Advanced Optimization optimizes heat transfer and replaces, partially
or totally, the thermal loads of packaged air-
The LDK Hybrid adiabatic cooling system cooled chillers.
can save up to 80% in energy costs annually Study of the effects of side by side units Study of optimized V shaped adiabatic cooler
This reasults in reduced energy consumption
by operating as a free-cooler during winter when compared to alternative dry cooling
time and mid-season. systems.

12
High Operational Frame
Reliability and Leak-Safety
Copper and
steel tube
LDK safety coil system carrying tubes do not
make contact with the casing, increasing
Aluminium
heat exchanger service life. Aluminium and
floating
plate Copper fins

18 19
Handrails, Ladders,
Configurability
Roof Top
Material Options LDK stands for:
Significantly reduced installation labor.
A complete set of arrangements are available for easy and safe service access when working at
heights.
Coil frame is always stainless steel
Value for the money is the key.
304L for superior corrosion protection
Frigel has long been the industry innovator
Copper tube coils are excellent for Safe Access for Service
in process cooling and LDK builds on this
most applications
past success and raises new standards.
SS 304 or 316L for corrosive Anti-slip fan decks
LDK is engineered to have low maintenance
environment or with deionized water Ladders and handrails in hot-dipped
in mind.
Fins are always Aluminum magnesium galvanized steel
The array of combination allows for making
( AlMg) to provide a superior quality Assembled on site by bolting only
the best choice for heat transfer, as well
for to coastal environments Crane to lifts and replace fans
for construction concerns.
HydroFin (Hydrophilic) coatings are
the right standard for spray systems
Extended Legs
due to amenity to wetting
E-Coat fins (C5) are suitable for very
2m up to 3 units side-by-side (13m
aggressive environments and high
long)
corrosion resistance
Steel structure made of hot-deeped
galvanized steel
Mechanical calculation report
available on request
Simplifies pitched installation for
“Self-Draining Configuration”
Coastal industrial site C5 Safe Access for Service

Roof top between units for easy


SS tubes Coastal enviroment C4 inspection and maintenance of pads
and sprays nozzles
CU tubes
CU tubes
E-coat fins
SS 304 tubes Industrial site C3
Blygold
AlMg Fins
Heresite CU tubes
AlMg coated AlMg Fins

Silent
Specific design help to further reduce the noise
emissions, up to -4dB per fan

20 21
Stay Operational Transport Install
with Service Fully assembled version (dry cooler)
delivered on low-body trucks
Factory wiring, plug &play control on
board
Pre-assembled with unmounted fan Trouble-free assembly of adiabatic
units for container deliveries pads
Handrails, ladders, rooftops and legs
are made for easy made for assembly
Ready for single crane lift off truck
into site position
The sturdy construction also ensures
helicopter lifts

The most imporant objective using an


adiabatic cooling system is, on top of
reliable functioning, its long lasting
operation.
It starts with the planning, selection and
construction of components.
Inspection and maintenance have never
been so simple and easy to perform as on
the ECODRY LDK.

The unique design of LDK takes into


account the rules of hygenic operation,
work safely at height and chemical
emissions. The Frigel Service includes cleaning,
Further, to minimize maintenance, all replacement parts and fans updating
parts are made in SS304L to make it highly to the latest energy-saving versions,
corrosion resistant when in contact with improving operating costs and reducing
water. the carbon footprint.

Maintenance and inspection are included Wide range of spare parts are available for
in a full range of professional service the entire life cycle.
packages, from commissioning, repairs
and troubleshooting to expansion.

22 23
Product range IndustrialChiller

MRS Air cooled chiller, small capacity up to 70 kW

Aquagel MRM Air cooled chiller, medium capacity up to 580 kW


MRT Air cooled chiller, medium capacity (air >52°C)
3HL Air cooled chiller, large capacity (45/52°C air)
GPV Modular pumping station for process with inverter
GPP Modular pumping station for process
GPR Modular pumping station for Ecodry recirculation
GPA Modular pumping station for chiller recirculation
GPE Simplified pumping station for Ecodry

ModularChiller

3FR + 3CR Modular chiller with remote air-cooled condenser


3FX Modular water-cooled chiller
3FA Modular air-cooled chiller, same sizes as 3FX
GPS Stainless steel tank from 1000 lt to 5000 lt
KTF Stainless steel filtering system

24 25