You are on page 1of 1

Outdoor Dual-band Combiner

CM-AE2-ODx, CM-AE2D-ODx (x= 1, 2, 3 or 4, Preconfigured DC-pass)


Band 1:790-862MHz Band 2:880-960MHz

 Co-siting purpose for feeder sharing


 Built with optional DC bypass, to be used with Tower Mounted Amplifiers and AISG
devices
 High isolation – minimizes interference
 High power handling and low loss – maximizes system performance
 Built-in lightning protection
 Available as a single unit or double units
Single unit photo for reference
Electrical Specifications
Pass Band Frequency Range (MHz)
Parameters / Specifications
790-862 880-960
Insertion Loss (dB) ≤0.4
Isolation between Ports (dB) ≥50
Return Loss (dB) ≥18
Maximum Input Power per Port (W) 200
Intermodulation Products (dBc) ≤-155@2x43dBm
Impedance (Ω) 50

Mechanical Specifications
Parameters Specifications
Dimensions, LxWxH (excluding connectors) Single Unit 188x176x68 / 7.4x6.9x2.7
(mm) / (in) Double Units 188x176x138 / 7.4x6.9x5.4
Single Unit 2.4 / 5.3
Weight (including connectors) (kg) / (lb)
Double Units 5.0 / 11.0
Color Light grey
RF Connectors 7/16 DIN-Female
Mounting Pole (clamps included for Ф35-125mm pole) or Wall Mounted
Operating Temperature Range (oC) -40 to +65
Operational Humidity (%) ≤95
Environmental Class IP66
Single Unit 350x250x130 / 13.8x9.8x5.1
Shipping Dimensions, LxWxH (mm) / (in)
Double Units 350x250x200 / 13.8x9.8x7.9
Single Unit 2.9 / 6.4
Shipping Weight (kg) / (Ib)
Double Units 6.0 / 13.2
Lightning Protection Comply with IEC 61000-4-5; 8kA, 8/20s

Ordering Information Block Diagram


Port 3
Single unit Model Double units
DC Bypass Optional
Number Model Number
CM-AE2-OD1 CM-AE2D-OD1 No DC Bypass
DC/AISG Bypass

DC/AISG Bypass

CM-AE2-OD2 CM-AE2D-OD2 DC Bypass @790-862


CM-AE2-OD3 CM-AE2D-OD3 DC Bypass @880-960
CM-AE2-OD4 CM-AE2D-OD4 Full DC Bypass

Port 1 Port 2
790-862 880-960

© Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering. Page 1 of 1
Specifications may differ depending on region and customers’ requirements.
DS-Control: 3-0-2 / 0815