You are on page 1of 2
° CONG TY THU NGHIEM VA KIEM DINH QUOC TE INTERNATIONAL TESTING AND INSPECTION SERVICE COMPANY ITs Road No. 12, Dong Xuyen1Z, Rach Dua Ward, Vang Tau City Your Trusted Inspection Partner "Tel: (84)2543 897 868 ~ Pax: (84)284.3 833 679 Certificate No [ DY- O060/o4 TITS Customer P.O No: ‘Owner PYCMSR ‘Address : Sao Mai Ben Dinh, Thang Nhat ward, Vung Tau cit Tnspection procedure _| QTO1-ITIS/ Lifting equipments inspection/testing procedure Codes/st is Pa -4; AREER) “ASTM — E165; According to client's Date of inspection test: 25/01/2021 | Place: ITIS Workshop Reason for issuing the certificate: initial certificate O Re-certificate C1 After repair_Wlother This isto certify that the undersigned Inspector and Surveyor did attend the inspection of the equipment mentioned and report as follows References ; Numer | ephing [Tes tad Description of Gear | Serial No Dimension Symbes | load limit | Applied (kgs) | ches) MK 109-1-1 | Type: single wire rope sling. NRO? Dia and length otro 7émmx7,1 | 02. | 90300 | 140000 MK 109-1-2 | m ferrules secured bolt end soft eye uti cklist ‘The wire rope sling has been inspected as follow: | Type of inspestion Result Tte, Description Visual | MPU |” Before ‘Afier | Conclusion | Remark DPI load test_| load test T_| Marking 7D S| Na A S 5 2 | Leg rope and rope eyes Sah NAL pS S Ss 3 Dim of maiched legs 57 [SNA s Ss + Ferrule / Thimble eye S Ss s Ss S S| Others: Ss awa [os ss TMS Recommended for next examination/test: VisuaV/NDT: 07/2021 - __Lond test: 01/2022 We certify that the above particulars are correct, and that the examination and test was carried out by the competent person; found to have withstood the proof load with out deformation: found to be free from cracks, flaws or other defects: and that the above particulars are correct Inspector/Examiner Spy nti Dao Ghitn Lag “The above equipment has been tested and examined and is for normal use by a person who has been instructed, trained and where necessary is supervised in its proper use. Remark: $= Satisfaction - N/A Not Applicable - RR = Repairs required -R_ = Reject pera a eC a CONG TY THU NGHIEM VA KIEM DINH QUOC TE INTERNATIONAL T AND INSPECTION SERVICE COMPANY ‘Road No. 12, Dong Xuyen 1Z, Rach Dua Ward, Vang Tau City “Tels (84)2543 837 868 - Fax: (8432543833 679 IT:S —— 6 (Report Noy: WN 0bd.lelA TITS BAO CAO KIEM TRA THAM THAU DYE PENETRANT TESTING REPORT a Lo , ngay 28... théng..Od.nim flat... ‘Bon vi yeu cdu KT (Giient): PVC MSP Ngubi kim tra (Examiner): DUONG BUC NGHIA Quy trinn kiém tra (Examination procedure No.) 0\/ NDT.Po2-PT Dia diém kiém tra (Place of test): ITIS Workshop Gle PT dp 2 - PT Level 2 Tibu chudin danh gié: ASTM - £165 01 TUGNG KIEM TRA (OBJECT UNDER TEST) ‘Tén thiét bj (Name of equipment: (Chi tiét s6 (Mark No / Part Noy. | Nuvober of tested ‘Single Wire Rope Sling WLL 90,3 T MK 109-1-1 © 76 mm x 7,1 m ferrules secured bolt end softeye MK 109-1-2 es Vat ligu (Material base): Diéu kign bé mat (Surface Nhigt d6 mi trudng (Ambient Temperature): Aluminum Condition): Accept 30°C THONG TIN VE VAT TU KIEM TRA KY THUAT KIEM TRA (TESTING MATERIALS INFORMATION) (PT TECHNIQUE) } Thdi gian | wants | st | en | wean | fein tn a (Brand) (Batch No.) date (Owell Time) dang thdy dupe duti Anh séng L (min) I ‘thudng Ghat thd thdu (Penetrant) | NABAKEM NA WA 10 | ht hién (Developer) | NABAKEM |N/A WA 10 ern Ghat lim sach (Remover) | N4BAKEM | _NA NA 40 penetra} DANH GIA (EVALUATION) | 61 TUNG KIEM TRA MO TA KHUYET TAT anh gid (JOINT IDENTIFICATION) UINTERPRETATION OF DEFECT) (Evaluation) Ngay kiém tra Chi tit 36 Téng chiéu dai vite | boai | Chiéu dai (Day of examination) (10. Joint | (Tota length) (mm) | (Location) | (rye) | (Lengtny | Assert | Retest Fernule 7 1 1 e 2510/2021 NGUGI KIEM TRA PT Technician E- ~ Duong Dite Nght aN ag TO ea

You might also like