S.N.

Chainage Bridge name Bridge span Foundation type

1 151+140 Chandra Canal 15 m Pile Foundation

2 156+300 Babhana Bridge 12m Open Foundation

3 157+160 Badhua bridge 12m Open Foundation


4 158+860 Murkutwa Khola 12m Open Foundation
5 174+800 Tarkhan- 1 12m Open Foundation

6 182+330 Chapin -1 12m Open Foundation


7 188+170 Patharwa -2 12m Open Foundation
Remarks

Bridge deck level is 1.85 m above the existing bridge deck level. Also
Hulaki highway crosses near the bridge. So, Deck level of new bridge
should be decreased to existing bridge deck level.

Existing bridge is at high elevation. So, it needs proper sheet piling


work during excavation of foundation
Existing bridge is at high elevation. So, it needs proper sheet piling
work during excavation of foundation
It is safe in open foundation
It is safe in open foundation
Canal is passed through the bridge, So diversion of water should be
done during foundation excavation.
It is safe in open foundation