You are on page 1of 11

SIMATIC WINCC OPEN ARCHITECTURE V3.

18

Visualiszation
made easy
From efficient plant to effective operational design:
Welcome to the optimized future with SIMATIC WinCC Open
Architecture V3.18 - with the integrated dashboard on the way to
unprecedented possibilities.
siemens.com/wincc-open-architecture
SIMATIC WinCC Open Architecture V3.18  Visualization made easy

VISUALIZATION MADE EASY

SIMATIC
WinCC Open Architecture V3.18

SIMATIC WinCC Open Architecture SIMATIC WinCC Open Architecture Highlights:

forms part of the SIMATIC product • Object orientation facilitates efficiency in engineering
and flexible system expansions
family and is designed for use in
• Possibility to create single server solutions
applications requiring a high degree • End 2 End Redundancy from PLC level to SCADA solution
of client-specific adaptability, large • Scalable up to networked redundant high-end systems

and/or complex applications and with more than 10 million tags and 2.048 servers
• View and control all servers via a central control center
projects that require specific system
• A wide range of operating systems or virtual environ-
functions. As a SIMATIC SCADA ments
system it is well-prepared to • Hot Standby Redundancy and Disaster Recovery-System

connect to SIEMENS PLCs and to guarantee highest reliability and availability


• The perfect match for globally spread solutions
handle huge amounts of data even
• Platform for customized solutions
on smaller hardware solutions. • Comprehensive range of drivers and connectivity:
SIMATIC S7, PROFISAFE/PROFINET, MQTT, OPC UA,
Modbus, IEC 60870-5-101/104, DNP3, IEC 61850, IEC
61400, Ethernet/IP, S-Bus, MindSphere Connector and
many more

Supported operating systems


• Windows 2019 Server
• Windows 2019 Server LTSC
• Windows 10 CB Version 20H2
• Windows 10 LTSC 2019
• Red Hat Enterprise Linux 8.2
• Oracle Linux
• SIEMENS Industrial OS 2.x
• Docker – Debian 10
• VMware ESXi 7
• vSphere HA Cluster

2 
Visualization made easy  SIMATIC WinCC Open Architecture V3.18

42°

Dashboard
New Version Dashboard
SIMATIC WinCC Open Architecture V3.18 This new function simplifies the creation of web
WinCC OA empowers you to follow your own dashboards. With it, it’s possible to parametrize
success story:  Until now it was most important to widgets anytime and anywhere during runtime. A
do things right – that means efficiency. wizard-guided process makes the widgets easily
adaptable to each user’s individual data visualiza-
The new trend however leads us to do the right
tion goals.
things instead – that means effectiveness. The
new product version V.3.18 opens up new ways to The dashboard is web-based and supports a large
do so. variety of widgets. Dynamic SVGs can also be
integrated. To sum up, it is possible to completely
With the web-based dashboard it is possible to
customize the dashboard and therfore create
parameterize widgets anytime and from
user-specific solutions.
anywhere, even during runtime. That easy adapt-
ability offers a simple way for users to visualize
their data. 

 3
SIMATIC WinCC Open Architecture V3.18  Visualization made easy

Modern Classic

OR

Neue Icon Themes


New Icon Themes Connector Points
As a new design-related feature, a new style set Known from graphical objects used in Power-
has been introduced which handles the implemen- point-Presentations, a useful new connector point
tation and one-click-switch of icon themes. function has been introduced to objects for
WinCC OA user interfaces.
Firstly, a new icon theme has been developed and
included within the new version. It is now possible to connect objects via connector
points. When the objects are moved, the
Secondly, it is now possible to integrate custom-
connections automatically find new paths. It
ized icon themes that fully conform to any
is also possible to connect different types of
corporate design requirements.
graphical objects.
Similar to other style sheet implementations, it is
possible to switch the themes during runtime.

Driver Enhancements
New drivers have been released to connect to
OMRON FINS as well as SINUMERIK powerline
devices.

SINUMERIK devices can also be added to a project


via OPC connection.

In addition, the S7+ Driver now supports TLS.


Coonector Points

New OPC UA security policies have been inte-


grated as well as OPC UA method support,
including WinCC OA alarm mapping to OPC UA
severities.

4 
Visualization made easy  SIMATIC WinCC Open Architecture V3.18

WinCC OA
Archiving Next
Tags Generation
Read / Write Archiver
Custom DB
API

Alarms
Read / Write

Configuration
Central Configuration
RDB

Next Generation
Archiver (NGA) Next Generation Archiver (NGA)
Enhancements
While the last version of WinCC OA already
enabled a connection to InfluxDB, the version 3.18
offers a broader range of supported databases. It
is now possible to connect to PostgreSQL as well Online Documentation is Available
as MS SQL database. Furthermore, data handling Until now, it was always necessary to download
has been optimized which leads to increased the WinCC OA software package in order to receive
performance and a higher flexibility in engi- documentation regarding features.
neering.
Starting with Version 3.18, an online version of the
On top of that, the NGA adds value to your solu- documentation will be available, offering a quick
tion by offering an open interface to connect to way to look up information no matter where you
customer implementations. The NGA can be used are. No installation is required to learn more about
in parallel with the existing value-based archiving WinCC OA. This online help will be available in
system, as well as Oracle database. It is even English as well as in German.
possible to combine these three archiving systems.

Documentation

Search ...

Online Documentation

 5
SIMATIC WinCC Open Architecture V3.18  Special Functions

SPECIAL FUNCTIONS

SIMATIC
WinCC Open Architecture V3.18

Object Orientation
• Referencing of symbols and objects
• Inheritance of structured data point types
• Object hierarchy
• Direct mapping of data point types to objects
• Flexible plant model - different views on the
datamodel realizable

Parallel Archiving
Primary Server System (PSS) Secondary Server System (SSS) The parallel archiving in different data bases has
been updated, based on the list of supported data
bases in NGA, and enables the storage of data into
Database in Database in
the local historical database and into the chosen
Oracle Cluster Oracle Cluster
second data base.The Next Generation Archiver

WinCC OA WinCC OA
can archive locally and centrally by itself. Both
Hot Standby Hot Standby
WinCC OA System WinCC OA WinCC OA System WinCC OA
archiving methods
active passive active passive
Server (A) Server (B) Server (C) Server (D)
(Oracle and NGA) are compatible with the Disaster
Recovery System, historical queries and archive
compressions.
Field device or other
connected systems like
User Interfaces
for example OPC UA

Security
• IIEC 62443-4-2 certification
Disaster Recovery
System • Blocking via IP-Blacklist
Redundancy • System stability due to intrinsic safety
• Hot Standby • Autonomic systems
• Disaster Recovery System (2x2 Redundancy) • Communication (Standard: SSL encryption,Op-
The aim of this feature is to extend the WinCC tion: Secure)
OA redundancy concept through a second Hot • New standard project with highest security
Standby System. Thus, the data loss and the idle setting SSL encryption of managers based on
time are kept as low as possible. specific certificates
• Automatic client switch-over • Encryption of panels, scripts and libraries
• Automatic recovery • Enhanced security developments for specific
• Automatic process image and history synchroni- drivers
zation • TLS gateway now supports encryption
• Automatic synchronization of project data
• Redundant networks (LAN)
• Redundant peripheral component support
• (SIMATIC S7)
• Split mode operation for updates and testing

6 
Special Functions  SIMATIC WinCC Open Architecture V3.18

Integration of Maps Enhanced Possibilities:


Full integration of state-of-the-art cartographic • Add curves via Drag & Drop
information into WinCC OA, including Open- • Trend configuration based on instantiation
StreetMap. Possible integration of Web Map • Copy to clip board functionality supported
Service (WMS) and Google Maps (requires sepa-
rate license from Google) and GIS solutions.
Harmonized Upgrade Services -
Software Support Center
Video Based on customer´s requirement and needs
Offers the easy possibility to integrate IP-cams, given by solution design it might be necessary to
IP-components which fulfill the ONVIF 2.0 stan- think about updates of the software. While
dard and complete video management systems granting a lifecycle management, this also
into WinCC OA. Due to the integration of SCADA includes plannable steps towards integrating new
and video management into one system, the trends and higher standards regarding security.
interfaces can be reduced. The costs for training,
Based on these thoughts WinCC OA offers agreed
maintenance and operation are also reduced to a
ways to provide updates reaching from smaller
minimum. To design a new video solution, you can
upgrades during one version to jumping to
use our basic package that already includes several
another version when available. It is up to decide
useful features. Finalize the planning by simply
when ordering the new version.
adding the number of needed cameras to your
project. The video feature is available for Linux, as
well as for mobile apps; required platforms are Reporting
minimum iOS 12.3 or Android 6.* • Web-based Reporting Interface (SOAP): Eclip-
se BIRT, Crystal Reports, SIMATIC Information
Server, Microsoft Excel, Several templates for
Trending 2.0
ECLIPSE BIRT and examples for SIMATIC Informa-
Trend widgets for integration into customized
tion Server
screensanda trend application (Var-Trend) as
• Online values, history
aready-to-use trend application. Supports:
• Compressed data, SQL, alarms
• Online and historical values • Diagnostics tools
• Value trend over time or value • Audit trail
• Time comparison trends
• Bar trends 2D and 3D
• Color and filling pattern for trend curves
• Display of invalid values, alarm range and/or
value range
• Multiple or shared scales, ruler, automatic
legend
• Time resolution in ms, switch during runtime
between
• local and UTC-time
• Zoom / Unzoom of trend areas Trending 2.0

* Will be available later in a patch

 7
SIMATIC WinCC Open Architecture V3.18  Technical Data

TECHNICAL DATA

SIMATIC
WinCC Open Architecture V3.18

Architecture Process Interfaces / Drivers


• Client-server-system • Event-driven or cyclic polling
• Functional separation into several processes • Several different drivers at the same time on
(managers) one server
• Event orientated process • Periphery time stamps
• Load distribution on several computers • TCP/IP: SIMATIC S7, SIMATIC S7 Plus, MQTT,
• Redundancy (Hot Standby) PROFINET/PROFISAFE, TLS Gateway, Modbus,
• Disaster Recovery System Ethernet/IP, BACnet,OMRON_Fins, SINUMERIK
• Multi-server - distributed systems up to 2048 Powerline
systems • OPC: DA, AE, HDA (Client & Server)
• Heterogeneous operating systems and versions • OPC UA: DA, AC, HA (Client & Server)
possible • Tele control / RTU: SSI, IEC 60870-5-101, -104,
• Multi-monitor operation DNP3, SINAUT, IEC 61850/61400
• Multi-login on one workstation • Over 25 drivers natively supported
• Multi-user system • Additional drivers on request or via C++ API
• Internal message compression
• Safety functions to increase reliability
Alarm System
(overloaddetection and regulation, query
• VDI 3699 / DIN 19235
restrictions)
• Freely definable alarm classes with 255 different
• Support of virtual environments and Docker
priorities and definition of alarm colors (blin-
container
king)
• Standard, discrete and multi-instance alarms
• Up to 255 analog alarm ranges
• Summary alarms
• Automatic filtering of alarms (handling of alarm-
floods)
• Panel hierarchy summary alarms
• Combined alarm- and event screen, alarm row
with definable column set and colors and advan-
ced sorting and filtering
• Storable configurations
Support of Docker Container
• Direct access to the associated process window
• Comments and attended values on alarms
• Split on warning areas and alarm areas
• Online change of alarm classes
• Showing Alarms in the trends

8 
Technical Data  SIMATIC WinCC Open Architecture V3.18

User Access
• Full user access security optional with
integration into Windows Active Directory
(Single Sign On)
• Various permission levels
• Command protocol (Audit trail)
• FDA 21 CFR Part 11 compliant
• Plugin mechanism for external authentication
systems like LDAP
• IEC 62443-4-2 compliant
• Improved integration of Active Directory
user management

Data Model
• Object oriented data model with freely definable Time Zone Handling
and easy configurable structure WinCC OA uses UTC time zone and allows to spre-
• Many standard objects included addistributed systems to different time zones. For
• Modeling of technological objects in any successful connection to the system the time has
hierarchy to be synchronized between the servers.
• User definable tree structure
• Several different properties definable on
Archiving
elements
Comprehensive archiving options
• Type-in-type (referencing)
• Next Generation Archiver (NGA)
• Inheritance
• Value archives as flat-file structure (HDB)
• Groups
• ORACLE archiving
• Generate different views on the data model
• Parallel archiving (Oracle, HDB, NGA)
• Data compression
Engineering Environment • Correction values
• Graphical editor • Laboratory values
• Project hierarchy editor (panel topology) • Web-based reporting interface (SOAP)
• Project editor • Reporting templates based on Eclipse BIRT and
• Database editor SIMATIC Information Server
• Control programming editor, Script Wizards •
• Mass data engineering and ASCII in / out
manager
• Integration of external version management
tools (CVS, SVN, …)
• Simple symbols, EWOs, style sheets, color
schemes (incl. Day/Night-Switch)
• Framework for engineering & application
user interfaces

 9
SIMATIC WinCC Open Architecture V3.18  Technical Data

Application Programming / Scripting


• Interpreter with C-syntax (“Control” language)
and multithreading support
• Object oriented aspects like classes
• Libraries and DLLs for customized extensions
of the scripting language
• Debugger / diagnostic tools
• Supports a lot of external interfaces, such as:
'database access, ADO, COM and XML,
XML Parser, XML-RPC-Interface, UART- and
Graphical User Interface TCP-access, WebSockets
• Drag & Drop • Complete access to attributes of graphical
• JavaScript objects
• Platform neutral application • Know-how protection (Panel- / script encryption)
• Zooming / Panning • Additional Businesslogic via C++ or C# API
• Cluttering / Decluttering • TIA Importer supporting TIA projects in Versions
• Root-, child- and embedded panel V14, V15, V16
• Multi-monitor operation
• True color / synchronous blinking
Internet / Intranet
• Up to 8 picture layers
• Desktop UI
• Online tool tips (multilingual)
• Mobile UI for iOS and Android
• Configurable panel topology
• Ultralight Client ULX UX (HTML5)
• GUI navigation objects
• Dashboard and mobile Dashboard
• Online switchable multi language support
• Webserver, web alarm screen, diagnostics and
• Switch of color sets and style sheets during
reporting
runtime
• Supports main security functions (HTTPS, SSL,
• Supports the widely used graphical objects
Kerberos encryption, etc.)
and widgets also with comprehensive
animation capabilities
• Support of external widgets Certified Standards
• Layout management “Responsive design“ • IEC 61443-4-1/61443-4-2
• Multitouch support: zooming, panning, • IEC 61508 (SIL3)
decluttering, safe two-hand operation and • IEC 61850/61400 Client (KEMA/DNV GL)
custom gestures • OPC UA
• Navigation through panel hierarchy • PROFINET/PROFISAFE (Client)
• Animations: panel transition, object animations, • BACnet (B-OWS)
animation groups

Objekt Libraries
• WinCC OA standard object library
• BACnet object library
• Library of Basic Processes (LBP)
• Build up your own libraries and reuse them

10 
ETM professional control GmbH Customer is responsible to prevent unautho-
A Siemens Company rized access to its plants, systems, machines
Marktstrasse 3 and networks. Systems, machines and compo-
nents should only be connected to the enter-
7000 Eisenstadt
prise network or the internet if and to the
Austria extent necessary and with appropriate security
Phone: +43-2682-741-0 measures (e.g. use of firewalls and network
www.etm.at segmentation) in place.
info@etm.at Additionally, Siemens’ guidance on appropriate
security measures should be taken into
Subject to changes 04/21 account. For more information about industrial
security, please visit http://www.siemens.com/
© ETM professional control GmbH
industrialsecurity.
Security information Siemens’ products and solutions undergo
Siemens provides products and solutions with continuous development to make them more
industrial security func- tions that support the secure. Siemens strongly recommends to apply
secure operation of plants, systems, machines product updates as soon as available and to
and networks. always use the latest product versions. Use of
product versions that are no longer sup- ported,
In order to protect plants, systems, machines and failure to apply latest updates may increase
and networks against cyber threats, it is customer’s exposure to cyber threats.
necessary to implement – and continuously
main- tain – a holistic, state-of-the-art indus- To stay informed about product updates,
trial security concept. Siemens’ products and subscribe to the Siemens Industrial Security RSS
solutions only form one element of such a Feed under http://www.siemens.com/industri-
concept. alsecurity.

You might also like