You are on page 1of 25

PARAMETER LIST AND ERRORS

“TOUCHLINE” OVENS

SOFTWARE VERSION:
POWER: P1.60
USER: U6.22

NOTE: The firmware versions P1.60 – U6.20, P1.60 –


U6.21 e P1.60 – U6.22 shares the same parameter list

MODEL

ONE
Sheet n° 1/25
This document contains confidential information and is the property of ELECTROLUX PROFESSIONAL Vallenoncello,Italy without whose permission
it may not be copied,shown or handed to a third party or otherwise used and it is to be returned promptly upon request to the ELECTROLUX
PROFESSIONAL Vallenoncello,Italy which is responsible for the document.
TITLE
PARAMETER LIST AND ERRORS “TOUCHLINE” OVENS,
SOFTWARE VERSION 6.22 (USER INTERFACE)
MODEL NUMBER REV

ONE 41140000912 R.000

TITLE
PARAMETER LIST AND ERRORS “TOUCHLINE” OVENS, FIRMWARE VERSION 6.21 (USER INTERFACE)
Tipo:
U = User: User modifiable parameters (available in Make-It-Mine)
S = Service: Service only parameters LW 6 1/1 LW 10 1/1 LW 20 1/1 LW 10 2/1 LW 20 2/1 LW 6 2/1 RANGE
RTC = Clock: Real Time Clock parameters (will be unaffected by the parameters
default command)

measure
ELT GAS ELT GAS ELT GAS ELT GAS ELT GAS ELT GAS
Par N°

Default
Unit
Name Type Description Min Max
T K T K T K T K T K T K T K T K T K T K T K T K
1 SEC RTC Seconds - 0 59
2 MIN RTC Minutes - 0 59
3 HOUR RTC Hours - 0 23
4 DAY RTC Day - 1 31
5 MON RTC Month - 1 12
6 YEAR RTC Year - 0 99
Appliance type
0 = Electric
7 GAS S 1 = Gas
0 1 1 1 1 1 1 1 1 1 1 1 1 0 1

Motorized valve
0 = None
8 ENFL S 1 = Motorized
1 0 1

Temperature scale
0 = Celsius
9 FAHR S 1 = Fahrenheit
0 N1 N1 N1 N1 N1 N1 N1 N1 N1 N1 N1 N1 N1 N1 N1 N1 N1 N1 N1 N1 N1 N1 N1 N1 0 1

Displayed temperature adjustment


0 = Disabled
10 CORT S 1 0 1
1 = Enabled

Temporary modifiable programs


0 = Enabled
11 NMOD U 0 0 1
1 = Disabled

Oven cooks with door open


0 = Disabled
12 DSOD S 0 0 1
1 = Enabled

Lambda sensor
0 = Disabled
13 LAMB S 1 = Enabled 1 0 0 0 0 0 0 0 0 0 0 0 0 0 1

Core probe type


0 = None 1 1 1 1 1 1 1 1 1 1 1 1
14 PRB S 1 = Single-point 2 0 2
2 = Multi-point N12 N12 N12 N12 N12 N12 N12 N12 N12 N12 N12 N12

Foglio n° 2/25
This document contains confidential information and is the property of ELECTROLUX PROFESSIONAL Vallenoncello,Italy without whose permission it may not be copied,shown or handed to a third party or otherwise used
and it is to be returned promptly upon request to the ELECTROLUX PROFESSIONAL Vallenoncello,Italy which is responsible for the document.
TITLE
PARAMETER LIST AND ERRORS “TOUCHLINE” OVENS,
SOFTWARE VERSION 6.22 (USER INTERFACE)
MODEL NUMBER REV

ONE 41140000912 R.000


TITLE
PARAMETER LIST AND ERRORS “TOUCHLINE” OVENS, FIRMWARE VERSION 6.21 (USER INTERFACE)
Tipo:
U = User: User modifiable parameters (available in Make-It-Mine)
S = Service: Service only parameters LW 6 1/1 LW 10 1/1 LW 20 1/1 LW 10 2/1 LW 20 2/1 LW 6 2/1 RANGE
RTC = Clock: Real Time Clock parameters (will be unaffected by the parameters
default command)

measure
ELT GAS ELT GAS ELT GAS ELT GAS ELT GAS ELT GAS
Par N°

Default
Unit
Name Type Description Min Max
T K T K T K T K T K T K T K T K T K T K T K T K
Oven level
5 = Convection (level K)
15 APPL S 6 5 5 5 5 5 5 5 5 5 5 5 5 5 6
6 = Combi (level Touch)

Oven model
0 = 6 GN 1/1
1 = 10 GN 1/1
2 = 20 GN 1/1
16 APPM S 0 1 1 1 1 2 2 2 2 3 3 3 3 4 4 4 4 5 5 5 5 0 5
3 = 10 GN 2/1
4 = 20 GN 2/1
5 = 6 GN 2/1

Minimum boiler ON during steam 100°C cycle


17 STON S sec 5 1 250
Minimum boiler OFF during steam 100°C cycle
18 STOF S sec 20 1 250
Locking alarms
0 = No error
1 = Upper fan motor
19 ALFN S 2 = Lower fan motor 0 0 4
3 = Both fan motors
4 = Boiler level probes

Preheating temperature of the boiler °C 85 50 0 100


20 SPHB S
°F 185 122 32 212
Threshold for boiler descaling warning °C 115 130 130 130 130 130 130 0 150
21 SINC S
°F 239 266 266 266 266 266 266 32 302
Altitude above sea level
22 SEAL S meters 0 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 0 4000
Max humidity value to stop the boiler
23 HBYP S % 98 80 100
Max temperature for water injecton °C 220 0 300
24 THMA S (humidifying)
°F 428 32 572
Max temperature for water injecton (cooling) °C 180 0 300
25 TRMA S
°F 356 32 572
Min temperature for water injecton °C 30 0 300
26 TRMN S (humidifying)
°F 86 32 572
Max time with cavity temperature higher than
27 DUTM S TCMS min 6 1 900

Foglio n° 3/25
This document contains confidential information and is the property of ELECTROLUX PROFESSIONAL Vallenoncello,Italy without whose permission it may not be copied,shown or handed to a third party or otherwise used
and it is to be returned promptly upon request to the ELECTROLUX PROFESSIONAL Vallenoncello,Italy which is responsible for the document.
TITLE
PARAMETER LIST AND ERRORS “TOUCHLINE” OVENS,
SOFTWARE VERSION 6.22 (USER INTERFACE)
MODEL NUMBER REV

ONE 41140000912 R.000


TITLE
PARAMETER LIST AND ERRORS “TOUCHLINE” OVENS, FIRMWARE VERSION 6.21 (USER INTERFACE)
Tipo:
U = User: User modifiable parameters (available in Make-It-Mine)
S = Service: Service only parameters LW 6 1/1 LW 10 1/1 LW 20 1/1 LW 10 2/1 LW 20 2/1 LW 6 2/1 RANGE
RTC = Clock: Real Time Clock parameters (will be unaffected by the parameters
default command)

measure
ELT GAS ELT GAS ELT GAS ELT GAS ELT GAS ELT GAS
Par N°

Default
Unit
Name Type Description Min Max
T K T K T K T K T K T K T K T K T K T K T K T K
Cavity over-temperature alarm threshold °C 320 250 340
28 COT S (ETUC)
°F 608 482 644
Boiler over-temperature alarm threshold °C 125 140 140 140 140 140 140 90 200
29 BOT S (ETUB)
°F 257 284 284 284 284 284 284 194 392
Steam condenser ON threshold °C 90 93 93 83 93 93 50 300
30 HABP S
°F 194 199 199 181 199 199 122 572
OLD (internal use) °C 80 50 100
31 STBP S
°F 176 122 212
Automatic boiler draining timeout
32 DBON S h/4 1 0 999
Max boiler temperature for automatic drain °C 50 0 100
33 TCDB S N4 N4 N4 N4 N4 N4
°F 122 32 212
Cavity temperature offset °C 0,0 -10,0 10,0
34 OCA1 S
°F 0 -18 18
Electronic board cooling threshold °C 25 0 55
35 SBC S
°F 77 32 131
Boiler working time from last automatic drain
36 HBOL S h/4 0 0 32000
Convection cycle counter
37 HAIR S h/4 0 0 32000
Steam cycle counter
38 HSTM S h/4 0 0 32000
Combi cycle counter
39 HCMB S h/4 0 0 32000
EIA485 isolated port baudrate
0 = 1200 baud
1 = 2400 baud
2 = 4800 baud
40 BAUD S 3 = 9600 baud 3 0 6
4 = 19200 baud
5 = 38400 baud
6 = 57600 baud

EIA485 isolated port address


41 ADDR S 1 1 250

Foglio n° 4/25
This document contains confidential information and is the property of ELECTROLUX PROFESSIONAL Vallenoncello,Italy without whose permission it may not be copied,shown or handed to a third party or otherwise used
and it is to be returned promptly upon request to the ELECTROLUX PROFESSIONAL Vallenoncello,Italy which is responsible for the document.
TITLE
PARAMETER LIST AND ERRORS “TOUCHLINE” OVENS,
SOFTWARE VERSION 6.22 (USER INTERFACE)
MODEL NUMBER REV

ONE 41140000912 R.000


TITLE
PARAMETER LIST AND ERRORS “TOUCHLINE” OVENS, FIRMWARE VERSION 6.21 (USER INTERFACE)
Tipo:
U = User: User modifiable parameters (available in Make-It-Mine)
S = Service: Service only parameters LW 6 1/1 LW 10 1/1 LW 20 1/1 LW 10 2/1 LW 20 2/1 LW 6 2/1 RANGE
RTC = Clock: Real Time Clock parameters (will be unaffected by the parameters
default command)

measure
ELT GAS ELT GAS ELT GAS ELT GAS ELT GAS ELT GAS
Par N°

Default
Unit
Name Type Description Min Max
T K T K T K T K T K T K T K T K T K T K T K T K
HACCP mode
0 = Disabled
1 = Base
42 HCCP U 0 0 3
2 = Integrated
3 = Monitor

HACCP log time


43 TPRN S sec 60 0 250
Cavity heaters PWM: Start N3 N3 N3 N3 N3 N3 N3 N3 N3 N3 N3 N3

G20 40 40 40 40 40 40 30 30 30 30 30 30
G25 40 40 40 40 40 40 35 35 35 35 TBD TBD
44 STCA S G30 % 40 0 100
GPL
35 35 40 40 40 40 35 35 35 35 TBD TBD
G20 Australia AGA 40 40 40 40 40 40 35 35 35 35 40 40
G31 Australia AGA 40 40 40 40 40 40 30 30 30 30 TBD TBD
40 40 40 40 40 40 35 35 35 35 TBD TBD
Cavity heaters PWM: Reduced power N3 N3 N3 N3 N3 N3 N3 N3 N3 N3 N3 N3

G20 50 50 45 45 45 45 50 50 50 50 55 55
G25 40 40 40 40 40 40 50 50 50 50 TBD TBD
45 HACA S G30 % 40 0 100
GPL
35 35 30 30 30 30 50 50 50 50 TBD TBD
G20 Australia AGA 35 35 35 35 35 35 50 50 55 55 45 45
G31 Australia AGA 40 40 48 48 48 48 35 35 60 60 TBD TBD
38 38 58 58 58 58 52 52 52 52 TBD TBD
Cavity heaters PWM: Full power N3 N3 N3 N3 N3 N3 N3 N3 N3 N3 N3 N3

G20 100 100 90 90 90 90 85 85 85 85 100 100


G25 80 80 70 70 70 70 85 85 85 85 TBD TBD
46 FUCA S G30 % 80 0 100
GPL
45 45 50 50 50 50 95 95 95 95 TBD TBD
G20 Australia AGA 55 55 60 60 60 60 95 95 100 100 80 80
G31 Australia AGA 80 80 70 70 70 70 80 80 100 100 TBD TBD
60 60 90 90 90 90 82 82 82 82 TBD TBD

Foglio n° 5/25
This document contains confidential information and is the property of ELECTROLUX PROFESSIONAL Vallenoncello,Italy without whose permission it may not be copied,shown or handed to a third party or otherwise used
and it is to be returned promptly upon request to the ELECTROLUX PROFESSIONAL Vallenoncello,Italy which is responsible for the document.
TITLE
PARAMETER LIST AND ERRORS “TOUCHLINE” OVENS,
SOFTWARE VERSION 6.22 (USER INTERFACE)
MODEL NUMBER REV

ONE 41140000912 R.000


TITLE
PARAMETER LIST AND ERRORS “TOUCHLINE” OVENS, FIRMWARE VERSION 6.21 (USER INTERFACE)
Tipo:
U = User: User modifiable parameters (available in Make-It-Mine)
S = Service: Service only parameters LW 6 1/1 LW 10 1/1 LW 20 1/1 LW 10 2/1 LW 20 2/1 LW 6 2/1 RANGE
RTC = Clock: Real Time Clock parameters (will be unaffected by the parameters
default command)

measure
ELT GAS ELT GAS ELT GAS ELT GAS ELT GAS ELT GAS
Par N°

Default
Unit
Name Type Description Min Max
T K T K T K T K T K T K T K T K T K T K T K T K
Boiler heaters PWM: Start N3 N3 N3 N3 N3 N3

G20 40 45 45 45 35 40
G25 40 45 45 45 35 TBD
G30
47 STBO S % 40 35 40 40 40 35 TBD 0 100
GPL
G20 Australia AGA 40 40 40 40 35 45
G31 Australia AGA 40 45 45 45 35 TBD
40 40 40 40 35 TBD
Boiler heaters PWM: Reduced power N3 N3 N3 N3 N3 N3

G20 50 45 55 55 47 37
G25 40 30 35 35 47 TBD
G30
48 HABO S % 40 35 35 47 47 35 TBD 0 100
GPL
G20 Australia AGA 35 40 55 55 45 30
G31 Australia AGA 40 42 50 55 47 TBD
35 37 47 47 52 TBD
Boiler heaters PWM: Full power N3 N3 N3 N3 N3 N3

G20 90 65 85 85 88 65
G25 80 60 60 60 88 TBD
G30
49 FUBO S % 80 60 55 90 90 60 TBD 0 100
GPL
G20 Australia AGA 70 65 100 100 75 50
G31 Australia AGA 90 60 80 75 88 TBD
70 50 75 75 85 TBD

Detergent injection time T1 (phase A) (50) (50) (50) (50) (50) (50) (50) (50)
50 CLT1 S 100 ms 40 70 70 70 70 50 50 50 50 80 80 80 80 50 50 50 50 0 250
N13 N13 N13 N13 N13 N13 N13 N13
Detergent+water injection time T2 (phase A) (10) (10) (10) (10) (10) (10) (10) (10)
51 CLT2 S 100 ms 15 0 250
N13 N13 N13 N13 N13 N13 N13 N13
Rinse-aid injection time T3 (phase C)
52 CLT3 S 100 ms 30 60 60 60 60 40 40 40 40 70 70 70 70 40 40 40 40 0 250
Water injection time T4 (phase C)
53 CLT4 S 100 ms 15 0 250

Foglio n° 6/25
This document contains confidential information and is the property of ELECTROLUX PROFESSIONAL Vallenoncello,Italy without whose permission it may not be copied,shown or handed to a third party or otherwise used
and it is to be returned promptly upon request to the ELECTROLUX PROFESSIONAL Vallenoncello,Italy which is responsible for the document.
TITLE
PARAMETER LIST AND ERRORS “TOUCHLINE” OVENS,
SOFTWARE VERSION 6.22 (USER INTERFACE)
MODEL NUMBER REV

ONE 41140000912 R.000


TITLE
PARAMETER LIST AND ERRORS “TOUCHLINE” OVENS, FIRMWARE VERSION 6.21 (USER INTERFACE)
Tipo:
U = User: User modifiable parameters (available in Make-It-Mine)
S = Service: Service only parameters LW 6 1/1 LW 10 1/1 LW 20 1/1 LW 10 2/1 LW 20 2/1 LW 6 2/1 RANGE
RTC = Clock: Real Time Clock parameters (will be unaffected by the parameters
default command)

measure
ELT GAS ELT GAS ELT GAS ELT GAS ELT GAS ELT GAS
Par N°

Default
Unit
Name Type Description Min Max
T K T K T K T K T K T K T K T K T K T K T K T K
Humidifier ON time during low temperature
54 HUON S combi cycle 100 ms 5 0 250
Lambda probe dry calibration point 76,29
55 OLBD S -40 -200 100
μV
Peak power management system
0 = Disabled
56 PPM S 1 = Enabled
Disabled 0 1

Demo mode
0 = Disabled
1 = Not available
57 DEMO S 0 0 3
2 = Portable (for simulator)
3=Event mode (for Exhibition)

OLD (internal use)


58 TBON S sec 0 0 2400
Water filling delay during boiler draining
59 DTSB S sec 255 N5 N5 N5 N5 N5 N5 0 255
Boiler preheating with oven in stop
60 DSPS U Disabled 0 1
High temperature working threshhold °C 280 0 300
61 TCMS S
°F 536 32 572
°C 99 0 200
62 ECLN S (Predisposizione per utilizzi futuri)
°F 210 32 392
Forced cleaning cycle timeout after a cooking
in Program mode
63 FCLN U 0 = No force clean; min 0 -1200 1200
(Use only positive values).
Detergent and rinse-aid level sensors
0 = Disabled
64 ALIE S 1 = Enabled 0 0 1

Cavity Heaters duty cycle


0 = Disabled
65 HDUT S 1 = Enabled 0 0 1

Foglio n° 7/25
This document contains confidential information and is the property of ELECTROLUX PROFESSIONAL Vallenoncello,Italy without whose permission it may not be copied,shown or handed to a third party or otherwise used
and it is to be returned promptly upon request to the ELECTROLUX PROFESSIONAL Vallenoncello,Italy which is responsible for the document.
TITLE
PARAMETER LIST AND ERRORS “TOUCHLINE” OVENS,
SOFTWARE VERSION 6.22 (USER INTERFACE)
MODEL NUMBER REV

ONE 41140000912 R.000


TITLE
PARAMETER LIST AND ERRORS “TOUCHLINE” OVENS, FIRMWARE VERSION 6.21 (USER INTERFACE)
Tipo:
U = User: User modifiable parameters (available in Make-It-Mine)
S = Service: Service only parameters LW 6 1/1 LW 10 1/1 LW 20 1/1 LW 10 2/1 LW 20 2/1 LW 6 2/1 RANGE
RTC = Clock: Real Time Clock parameters (will be unaffected by the parameters
default command)

measure
ELT GAS ELT GAS ELT GAS ELT GAS ELT GAS ELT GAS
Par N°

Default
Unit
Name Type Description Min Max
T K T K T K T K T K T K T K T K T K T K T K T K
Cooking preheating
0 = Disabled
66 PREH U 1 = Enabled 1 0 1

67 PAUT S (Internal use) 1 0 1


68 PFAC S (Internal use) 1 0 1
69 MAN S (Internal use) 1 0 1
70 E2PP S (Internal use) 1 0 1
User password
0 = Disabled
71 PASS S 1 = Enabled 0 0 1

72 DCLO S (Internal use) 1 0 1


Real time clock
0 = Disabled
73 ERTC S 1 = Enabled 1 0 1

Force half power GAS ovens


(internal use)
74 ABLP S 0 = Disabled 0 0 1
1 = Enabled

Quenching system temperature sensor


0 = Disabled
75 ABTF S 1 = Enabled 1 0 1

Cavity motor startup speed


0 = As set
1 = Force full speed 2 2 2 2 2 2 2 2 2 2 2 2
76 FAN S 2 = Force half speed 1 N6 N6 N6 N6 N6 N6 0 2
N9 N9 N10 N10 N9 N9 N10 N10 N9 N9 N10 N10

Heaters delay when fan starts N7 N7 N7 N7 N7 N7


77 DHEA S sec 0 N8 N8 N8 N8 N8 N8 0 60
N8 N8 N8 N8 N8 N8

Foglio n° 8/25
This document contains confidential information and is the property of ELECTROLUX PROFESSIONAL Vallenoncello,Italy without whose permission it may not be copied,shown or handed to a third party or otherwise used
and it is to be returned promptly upon request to the ELECTROLUX PROFESSIONAL Vallenoncello,Italy which is responsible for the document.
TITLE
PARAMETER LIST AND ERRORS “TOUCHLINE” OVENS,
SOFTWARE VERSION 6.22 (USER INTERFACE)
MODEL NUMBER REV

ONE 41140000912 R.000


TITLE
PARAMETER LIST AND ERRORS “TOUCHLINE” OVENS, FIRMWARE VERSION 6.21 (USER INTERFACE)
Tipo:
U = User: User modifiable parameters (available in Make-It-Mine)
S = Service: Service only parameters LW 6 1/1 LW 10 1/1 LW 20 1/1 LW 10 2/1 LW 20 2/1 LW 6 2/1 RANGE
RTC = Clock: Real Time Clock parameters (will be unaffected by the parameters
default command)

measure
ELT GAS ELT GAS ELT GAS ELT GAS ELT GAS ELT GAS
Par N°

Default
Unit
Name Type Description Min Max
T K T K T K T K T K T K T K T K T K T K T K T K
AND condition for standard FSC risk
0 = Disabled
78 ANDL S 1 = Enabled 1 0 1

AND condition for high FSC risk


0 = Disabled
79 ANDH S 1 = Enabled 0 0 1

Probe temperature threshold in FSC °C 50.0 0.0 99.0


80 HPTH S
°F 122 32 210
Cavity temperature threshold in FSC °C 65.0 0.0 400.0
81 HCTH S
°F 149 32 752
F threshold in standard FSC risk
82 FL S F/10 10 0 999
Probe threshold in standard FSC risk °C 57 0 99
83 TCL S
°F 135 32 210
F threshold in high FSC risk
84 FH S F/10 50 0 999
Probe threshold in high FSC risk °C 75 0 99
85 TCH S
°F 167 32 210
Open door timeout in FSC
86 HDTO S sec 30 0 255
Low Temperature Cooking
0 = Disabled
87 LTC U 1 = Enabled 1 0 1

88 DTPR S (Internal use) 0 0 0


89 BROW S (Internal use) 0 0 0
Proofing program
0 = Disabled
90 PROF U 1 = Enabled 1 0 1

Foglio n° 9/25
This document contains confidential information and is the property of ELECTROLUX PROFESSIONAL Vallenoncello,Italy without whose permission it may not be copied,shown or handed to a third party or otherwise used
and it is to be returned promptly upon request to the ELECTROLUX PROFESSIONAL Vallenoncello,Italy which is responsible for the document.
TITLE
PARAMETER LIST AND ERRORS “TOUCHLINE” OVENS,
SOFTWARE VERSION 6.22 (USER INTERFACE)
MODEL NUMBER REV

ONE 41140000912 R.000


TITLE
PARAMETER LIST AND ERRORS “TOUCHLINE” OVENS, FIRMWARE VERSION 6.21 (USER INTERFACE)
Tipo:
U = User: User modifiable parameters (available in Make-It-Mine)
S = Service: Service only parameters LW 6 1/1 LW 10 1/1 LW 20 1/1 LW 10 2/1 LW 20 2/1 LW 6 2/1 RANGE
RTC = Clock: Real Time Clock parameters (will be unaffected by the parameters
default command)

measure
ELT GAS ELT GAS ELT GAS ELT GAS ELT GAS ELT GAS
Par N°

Default
Unit
Name Type Description Min Max
T K T K T K T K T K T K T K T K T K T K T K T K
Reheating program
0 = Disabled
91 REG U 1 = Enabled 1 0 1

Start cooking by closing door


0 = Disabled
92 ABSP U 1 = Enabled 0 0 1

Multiphase cooking
0 = Single phase
93 FASI U 1 = Multiphase 1 0 1

Delayed starting
0 = Enabled
94 STDL U 1 = Disabled 1 0 1

Programs save
0 = Disabled
95 PRSA U 1 = Enabled 1 0 1

Language
0 = English UK 1 = English US
2 = Italian 3 = German
4 = French 5 = Spanish
6 = Dutch 7 = Belgium Dutch
8 = Belgium French 9 = Swedish
10 = Danish 11 = Portuguese
12 = Greekì 13 = Finnish
14 = Norwegian 15 = Russian
16 = Estonian 17 = Hungarian
96 LANG U 18 = Turkish 19 = Polish 0 0 34
20 = Slovenian 21 = Croatian
22 = Romanian 23 = Czech
24 = Slovak 25 = Latvian
26 = Lithuanian 27 = Bulgarian
28 = Serbian 29 = Chinese (Simpl)
30 = Chinese (Trad) 31 = Japanese
32 = Korean 33 = Arabic
34 = Hebrew.40 = future use

Foglio n° 10/25
This document contains confidential information and is the property of ELECTROLUX PROFESSIONAL Vallenoncello,Italy without whose permission it may not be copied,shown or handed to a third party or otherwise used
and it is to be returned promptly upon request to the ELECTROLUX PROFESSIONAL Vallenoncello,Italy which is responsible for the document.
TITLE
PARAMETER LIST AND ERRORS “TOUCHLINE” OVENS,
SOFTWARE VERSION 6.22 (USER INTERFACE)
MODEL NUMBER REV

ONE 41140000912 R.000


TITLE
PARAMETER LIST AND ERRORS “TOUCHLINE” OVENS, FIRMWARE VERSION 6.21 (USER INTERFACE)
Tipo:
U = User: User modifiable parameters (available in Make-It-Mine)
S = Service: Service only parameters LW 6 1/1 LW 10 1/1 LW 20 1/1 LW 10 2/1 LW 20 2/1 LW 6 2/1 RANGE
RTC = Clock: Real Time Clock parameters (will be unaffected by the parameters
default command)

measure
ELT GAS ELT GAS ELT GAS ELT GAS ELT GAS ELT GAS
Par N°

Default
Unit
Name Type Description Min Max
T K T K T K T K T K T K T K T K T K T K T K T K
Data monitor window
0 = Disabled
97 DATM S 1 = Enabled 0 0 1

Info-bar into the manual environment drawer


0 = Disabled
98 IBAR U 1 = Enabled 1 0 1

Green features (Bit0*1+Bit2*2+Bit3*4)


Bit 0 = Skip rinse-aid
Bit 1 = Skip drying
99 GREE U Bit 2 = Reduce water consumption 0 0 7

Date format
0 = GG/MM/AAAA
100 DAFT U 0 0 2
1 = MM/GG/AAAA
2 = AAAA/MM/GG
Time format
101 TIMF U 0 0 1
0 = 24H 1 = AM/PM
102 TOUD S Touchpanel Debounce 15 5 25
Quenching system activation time at startup
103 IMPF S 100ms 200 0 0 0 0 0 0 0 0 0 0 0 0 0 255
Minimum duration of probe cooking
104 MPRB S sec 60 0 255
Default duration of manual humidification
105 DMHU S sec 30 10 120
Standby Timeout
106 STBY U min 30 0 240
0 =Disabled
Boiler temperature in proofing mode °C 97 0 130
107 SPHF S
°F 207 32 266

Foglio n° 11/25
This document contains confidential information and is the property of ELECTROLUX PROFESSIONAL Vallenoncello,Italy without whose permission it may not be copied,shown or handed to a third party or otherwise used
and it is to be returned promptly upon request to the ELECTROLUX PROFESSIONAL Vallenoncello,Italy which is responsible for the document.
TITLE
PARAMETER LIST AND ERRORS “TOUCHLINE” OVENS,
SOFTWARE VERSION 6.22 (USER INTERFACE)
MODEL NUMBER REV

ONE 41140000912 R.000


TITLE
PARAMETER LIST AND ERRORS “TOUCHLINE” OVENS, FIRMWARE VERSION 6.21 (USER INTERFACE)
Tipo:
U = User: User modifiable parameters (available in Make-It-Mine)
S = Service: Service only parameters LW 6 1/1 LW 10 1/1 LW 20 1/1 LW 10 2/1 LW 20 2/1 LW 6 2/1 RANGE
RTC = Clock: Real Time Clock parameters (will be unaffected by the parameters
default command)

measure
ELT GAS ELT GAS ELT GAS ELT GAS ELT GAS ELT GAS
Par N°

Default
Unit
Name Type Description Min Max
T K T K T K T K T K T K T K T K T K T K T K T K
Startup environment
0 = Standard
1 = Manual
2 = Automatic
108 FENV S 3 = Programs 0 0 5
4 = Cleaning
5 = Settings

Manual environment (user enabling)


0 = Disabled
109 MAN U 1 = Enabled 1 0 1

Automatic environment (user enabling)


0 = Disabled
110 AUTO U 1 = Enabled 1 0 0 0 0 0 0 0 0 0 0 0 0 0 1

Programs environment (user enabling)


0 = Disabled
111 PROG U 1 = Enabled 1 0 1

Cleaning environment (user enabling)


0 = Disabled
112 CLEA U 1 = Enabled 1 0 1

FSC feature
0 = Disabled
113 FSC U 1 = Enabled 1 0 0 0 0 0 0 0 0 0 0 0 0 0 1

Cooking duration in seconds


0 = Disabled
114 SECC U 1 = Enabled 1 0 1

EcoDelta feature
0 = Disabled
115 ECOD U 1 = Enabled 1 0 1

Foglio n° 12/25
This document contains confidential information and is the property of ELECTROLUX PROFESSIONAL Vallenoncello,Italy without whose permission it may not be copied,shown or handed to a third party or otherwise used
and it is to be returned promptly upon request to the ELECTROLUX PROFESSIONAL Vallenoncello,Italy which is responsible for the document.
TITLE
PARAMETER LIST AND ERRORS “TOUCHLINE” OVENS,
SOFTWARE VERSION 6.22 (USER INTERFACE)
MODEL NUMBER REV

ONE 41140000912 R.000


TITLE
PARAMETER LIST AND ERRORS “TOUCHLINE” OVENS, FIRMWARE VERSION 6.21 (USER INTERFACE)
Tipo:
U = User: User modifiable parameters (available in Make-It-Mine)
S = Service: Service only parameters LW 6 1/1 LW 10 1/1 LW 20 1/1 LW 10 2/1 LW 20 2/1 LW 6 2/1 RANGE
RTC = Clock: Real Time Clock parameters (will be unaffected by the parameters
default command)

measure
ELT GAS ELT GAS ELT GAS ELT GAS ELT GAS ELT GAS
Par N°

Default
Unit
Name Type Description Min Max
T K T K T K T K T K T K T K T K T K T K T K T K
Buzzer volume
0 = Loud
116 ECBU U 1 = Normal 0 0 1

Expert mode: show real temperature/humidity


0 = Disabled
117 EXPR U 1 = Enabled 0 0 1

Long text rolling mode


0 = Disabled
1 = Characters shift
118 ABRO S 2 = Pixel shift 2 0 3
3 = Frame shift

Number of pixel for text rolling


119 NRRO S 5 0 10
Extra duration of Tips
120 DTIP S sec 0 0 250

121 LC1 S (Internal use) sec 300 10 300


122 LC2 S (Internal use) sec 300 10 300
123 LC3 S (Internal use) min 5 0 250
124 LC4 S (Internal use) min 5 0 250
125 LC5 S (Internal use) 5 0 250
126 LC6 S (Internal use) 5 0 250
(Internal use)
127 LC7 S min 30 1 250
(Internal use)
128 LC8 S min 30 1 250
(Internal use)
129 LC9 S min 30 1 250
(Internal use)
130 LC10 S -10 -200 100
(Internal use)
131 LC11 S -90 -200 100

Foglio n° 13/25
This document contains confidential information and is the property of ELECTROLUX PROFESSIONAL Vallenoncello,Italy without whose permission it may not be copied,shown or handed to a third party or otherwise used
and it is to be returned promptly upon request to the ELECTROLUX PROFESSIONAL Vallenoncello,Italy which is responsible for the document.
TITLE
PARAMETER LIST AND ERRORS “TOUCHLINE” OVENS,
SOFTWARE VERSION 6.22 (USER INTERFACE)
MODEL NUMBER REV

ONE 41140000912 R.000


TITLE
PARAMETER LIST AND ERRORS “TOUCHLINE” OVENS, FIRMWARE VERSION 6.21 (USER INTERFACE)
Tipo:
U = User: User modifiable parameters (available in Make-It-Mine)
S = Service: Service only parameters LW 6 1/1 LW 10 1/1 LW 20 1/1 LW 10 2/1 LW 20 2/1 LW 6 2/1 RANGE
RTC = Clock: Real Time Clock parameters (will be unaffected by the parameters
default command)

measure
ELT GAS ELT GAS ELT GAS ELT GAS ELT GAS ELT GAS
Par N°

Default
Unit
Name Type Description Min Max
T K T K T K T K T K T K T K T K T K T K T K T K
Touchpanel sound
0 = Disabled
1 = Normal
132 BSND U 2 = Soft 1 0 2

Cleaning cycle default


0 = Extra strong
1 = Strong
133 CLND U 2 = Medium 2 0 3
3 = Soft

Timeout cavity lamp

134 MLMP U 0=disabled min 15 5 255

135 ZONE S (Internal use) 0 0 0


Display F in screensaver
0 = Disabled
136 DSPF U 1 = Enabled 0 0 1

Hold Convection Default cavity temp °C 70 25 250


137 HCTC U
°F 158 77 482
Hold Steam Default cavity temp °C 70 25 100
138 HSTC U
°F 158 77 212
Default delta probe temperature in Hold °C 5 0 100
139 HDTP U
°F 9 0 180
Force FSC risk set on start button
0 = Disabled
140 FFSC U 1 = Enabled 0 0 1

MultiTimer cooking
0 = Disabled
141 MTMR U 1 = Enabled 1 0 1

Foglio n° 14/25
This document contains confidential information and is the property of ELECTROLUX PROFESSIONAL Vallenoncello,Italy without whose permission it may not be copied,shown or handed to a third party or otherwise used
and it is to be returned promptly upon request to the ELECTROLUX PROFESSIONAL Vallenoncello,Italy which is responsible for the document.
TITLE
PARAMETER LIST AND ERRORS “TOUCHLINE” OVENS,
SOFTWARE VERSION 6.22 (USER INTERFACE)
MODEL NUMBER REV

ONE 41140000912 R.000


TITLE
PARAMETER LIST AND ERRORS “TOUCHLINE” OVENS, FIRMWARE VERSION 6.21 (USER INTERFACE)
Tipo:
U = User: User modifiable parameters (available in Make-It-Mine)
S = Service: Service only parameters LW 6 1/1 LW 10 1/1 LW 20 1/1 LW 10 2/1 LW 20 2/1 LW 6 2/1 RANGE
RTC = Clock: Real Time Clock parameters (will be unaffected by the parameters
default command)

measure
ELT GAS ELT GAS ELT GAS ELT GAS ELT GAS ELT GAS
Par N°

Default
Unit
Name Type Description Min Max
T K T K T K T K T K T K T K T K T K T K T K T K
Forced rinse after descaling pending (internal use)
0 = Disabled
142 FDES S 1 = Enabled 0 0 1

USB core probe detection


0 = Disabled
143 UPRB S 1 0 1
1 = Enabled

Min OFF time for quenching system


144 ABOF S sec 10 0 255
Min ON time for quenching system
145 ABON S sec 5 0 255
Manual environment (main enabling)
0 = Disabled
146 MMAN S 1 0 1
1 = Enabled

Automatic environment (main enabling)


0 = Disabled
147 MAUT S 1 0 0 0 0 0 0 0 0 0 0 0 0 0 1
1 = Enabled

Programs environment (main enabling)


0 = Disabled
148 MPRG S 1 0 1
1 = Enabled

Cleaning environment (main enabling)


0 = Disabled
149 MCLN S 1 0 1
1 = Enabled

Skip preheat button when programs are not


modifiable
150 SKPR U 0 = Disabled 1 0 1
1 = Enabled

Max ON time for boiler heaters


151 HDON S 0 = no max limit min 0 5 0 255
Min OFF time for boiler heaters
152 HDOF S sec 60 20 10 255
Multitimer: temperature restoring after door
153 MCRT U opening. 0= disabled; 1 = enabled 0 0 1
Multitimer: preset loading enable during a cooking
154 MTPL U program upload. 0= disabled ; 1= enabled 1 0 1
Multitimer: max duration of temperature restoring
155 MCDM S sec 300 0 28800

Foglio n° 15/25
This document contains confidential information and is the property of ELECTROLUX PROFESSIONAL Vallenoncello,Italy without whose permission it may not be copied,shown or handed to a third party or otherwise used
and it is to be returned promptly upon request to the ELECTROLUX PROFESSIONAL Vallenoncello,Italy which is responsible for the document.
TITLE
PARAMETER LIST AND ERRORS “TOUCHLINE” OVENS,
SOFTWARE VERSION 6.22 (USER INTERFACE)
MODEL NUMBER REV

ONE 41140000912 R.000


TITLE
PARAMETER LIST AND ERRORS “TOUCHLINE” OVENS, FIRMWARE VERSION 6.21 (USER INTERFACE)
Tipo:
U = User: User modifiable parameters (available in Make-It-Mine)
S = Service: Service only parameters LW 6 1/1 LW 10 1/1 LW 20 1/1 LW 10 2/1 LW 20 2/1 LW 6 2/1 RANGE
RTC = Clock: Real Time Clock parameters (will be unaffected by the parameters
default command)

measure
ELT GAS ELT GAS ELT GAS ELT GAS ELT GAS ELT GAS
Par N°

Default
Unit
Name Type Description Min Max
T K T K T K T K T K T K T K T K T K T K T K T K
Multitimer: multitimer program environment
156 PRMT U enabling. 0= disabled; 1= enabled 1 0 1
Multitimer : temporary modify enabling on cooking
157 NMMT U programs. 0=enabled; 1=disabled 0 0 1
Multitimer: program save enabling. 0=disabled;
158 SPMT U 1=enabled 1 0 1
Multitimer: program erase enabling. 0=disabled ;
159 DPMT U 1=enabled 1 0 1
Multitimer: temporary preset modify enabling.
160 NMPR U 0=enabled;1=disabled 0 0 1
Multitimer: preset saving enable. 0=disabled; 1=
161 SPPR U enabled 1 0 1
Multitimer: preset erasing enable.
162 DPPR U 0=disabled;1=enabled 1 0 1
Multitimer: Program environment enabling (main
163 MPMT S enabling). 0=disabled; 1= enabled 1 0 1
Boiler water level sensors. Sensibility index. 0= 19,61
164 IXLV S Custom; 1=standard; 2...5=reduced sensibility 1 0 5
mV
Boiler water level sensors: lower threshold
165 LVLL S 51 0 255
Boiler water level sensors:higher threshold
166 LVLH S 102 0 255
Multitimer: advanced functions enabling (programs,
167 MTAV U preset). 0= disabled;1=enabled 1 0 1
Multitimer: preheating skip enabling when program
modify is enabled (parameter NMMT). 0=disabled;
168 MSKP U 1 0 1
1= enabled

Multitimer cooking enabling. (main enagling). 0=


169 MMT S disabled; 1= enabled 1 0 1
Extra strong cleaning cycle counter
170 CLVI S 0 0 32000
Strong cleaning cycle counter
171 CLI S 0 0 32000
Medium cleaning cycle counter
172 CLM S 0 0 32000

Foglio n° 16/25
This document contains confidential information and is the property of ELECTROLUX PROFESSIONAL Vallenoncello,Italy without whose permission it may not be copied,shown or handed to a third party or otherwise used
and it is to be returned promptly upon request to the ELECTROLUX PROFESSIONAL Vallenoncello,Italy which is responsible for the document.
TITLE
PARAMETER LIST AND ERRORS “TOUCHLINE” OVENS,
SOFTWARE VERSION 6.22 (USER INTERFACE)
MODEL NUMBER REV

ONE 41140000912 R.000


TITLE
PARAMETER LIST AND ERRORS “TOUCHLINE” OVENS, FIRMWARE VERSION 6.21 (USER INTERFACE)
Tipo:
U = User: User modifiable parameters (available in Make-It-Mine)
S = Service: Service only parameters LW 6 1/1 LW 10 1/1 LW 20 1/1 LW 10 2/1 LW 20 2/1 LW 6 2/1 RANGE
RTC = Clock: Real Time Clock parameters (will be unaffected by the parameters
default command)

measure
ELT GAS ELT GAS ELT GAS ELT GAS ELT GAS ELT GAS
Par N°

Default
Unit
Name Type Description Min Max
T K T K T K T K T K T K T K T K T K T K T K T K
Soft cleaning cycle counter
173 CLS S 0 0 32000
Steam generator (boiler tank) hour counter
174 QHBL S (steam+combi) h/4 0 0 32000
Prewarning time of electronic component
overheating and consequently automatic appliance
175 MHTS S min 30 0 58
switch off

Automatic mode: Preset management (general


enabling) 0= Disable; 1=
176 APMF S 1 0 1
Enable

Automatic Mode: Preset deleting. 0=


177 APD U Disable; 1 = Enable 1 0 1
Automatic mode: factory preset deleting. 0=
178 APDF U Disable; 1= Enable 1 0 1
Automatic mode: Preset saving.
179 APS U O=Disable; 1= Enable 1 0 1
Automatic mode: Factory preset Overwrite 0=
180 APOF U Disable; 1= Enable 1 0 1
Automatic mode: Preset loading from USB(upload).
181 UAP U 0= Disable; 1= Enable 1 0 1
Automatic mode: Factory preset loading (upload).
182 UAPF U 0= Disable; 1= Enable 1 0 1
Automatic mode: Preset saving on USB (download).
183 DAP U 0= Disable; 1= Enable 1 0 1
Automatic Mode: Factory preset saving on USB
(Download). 0= Disable; 1=
184 DAPF U 1 0 1
Enable

Automatic Mode: Preset modify. 0= Disable;


185 APC U 1 0 1
Automatic mode: Factory preset modify. 0=
186 APCF U Disable; 1= enable 1 0 1
Automatic mode: Factory preset saving.
187 APSF U 0=Disable; 1= enable 1 0 1

Foglio n° 17/25
This document contains confidential information and is the property of ELECTROLUX PROFESSIONAL Vallenoncello,Italy without whose permission it may not be copied,shown or handed to a third party or otherwise used
and it is to be returned promptly upon request to the ELECTROLUX PROFESSIONAL Vallenoncello,Italy which is responsible for the document.
TITLE
PARAMETER LIST AND ERRORS “TOUCHLINE” OVENS,
SOFTWARE VERSION 6.22 (USER INTERFACE)
MODEL NUMBER REV

ONE 41140000912 R.000


TITLE
PARAMETER LIST AND ERRORS “TOUCHLINE” OVENS, FIRMWARE VERSION 6.21 (USER INTERFACE)
Tipo:
U = User: User modifiable parameters (available in Make-It-Mine)
S = Service: Service only parameters LW 6 1/1 LW 10 1/1 LW 20 1/1 LW 10 2/1 LW 20 2/1 LW 6 2/1 RANGE
RTC = Clock: Real Time Clock parameters (will be unaffected by the parameters
default command)

measure
ELT GAS ELT GAS ELT GAS ELT GAS ELT GAS ELT GAS
Par N°

Default
Unit
Name Type Description Min Max
T K T K T K T K T K T K T K T K T K T K T K T K
Automatic mode: Multitimer cooking enabling
(general enabling). 0= Disable; 1=
188 AMTF S 1 0 1
enable

Automatic mode: Multitimer cooking enabling .


189 AMT U 0= Disable; 1= enable 1 0 1
Program mode: advance functions management
190 FAPM S enabling (general enabling). 0= disable; 1= enable 1 0 1
Program mode: advance functions management
enabling (Categories and Recent)
191 ADPM U 1 0 1
0= disable; 1= enable

Error "EACF" management enabling. Voltage lost


192 MFEN S on auxiliary circuit. 0= disable; 1= enable 0 0 1
USB communication enabling (general enabling).
193 FCDC S 0= disable; 1= enable 0 0 1
USB communication enabling (temporary enabling)
194 CDC U 0= disable; 1= enable 0 0 1
Software update enabling from settings
environment. 0=
195 UUFW S 0 0 1
disable; 1= enable

SD functionality check enabling. 0=


196 ADSB S disable; 1= enabling 0 0 1
Automatic mode: Preset management
197 MPRS U 0= Disable; 1= Enable 1 0 1
Extend calculation for pastorization factor F
(General enable)
198 FEXF S 1 0 1
0= Disable 1= Enable

Extend calculation for pastorization factor F


199 EXF U 0= Disable 1= Enable 0 0 1
F insertion in the HACCP log
(General enable)
200 FHF S 0=Disable 1= Enable
1 0 1

F insertion in the HACCP log


201 HF U 0=Disable 1= Enable 0 0 1

Foglio n° 18/25
This document contains confidential information and is the property of ELECTROLUX PROFESSIONAL Vallenoncello,Italy without whose permission it may not be copied,shown or handed to a third party or otherwise used
and it is to be returned promptly upon request to the ELECTROLUX PROFESSIONAL Vallenoncello,Italy which is responsible for the document.
TITLE
PARAMETER LIST AND ERRORS “TOUCHLINE” OVENS,
SOFTWARE VERSION 6.22 (USER INTERFACE)
MODEL NUMBER REV

ONE 41140000912 R.000


TITLE
PARAMETER LIST AND ERRORS “TOUCHLINE” OVENS, FIRMWARE VERSION 6.21 (USER INTERFACE)
Tipo:
U = User: User modifiable parameters (available in Make-It-Mine)
S = Service: Service only parameters LW 6 1/1 LW 10 1/1 LW 20 1/1 LW 10 2/1 LW 20 2/1 LW 6 2/1 RANGE
RTC = Clock: Real Time Clock parameters (will be unaffected by the parameters
default command)

measure
ELT GAS ELT GAS ELT GAS ELT GAS ELT GAS ELT GAS
Par N°

Default
Unit
Name Type Description Min Max
T K T K T K T K T K T K T K T K T K T K T K T K
Min temperature difference between cavity set and °C 5 0 10
202 PDTC U meat probe set
°F 9 0 18
End cooking buzzer type
203 BZET S 0 0 4
Meat probe temperature visualization with time
204 ASPB U mode cooking type 0 0 1
(internal use)
205 ASCD s 0 0 0
Ordinary maintenance reminder for water
206 DAPH U/S threatment days 0 0 1000
(internal use)
207 THPT S 0 0 32000
Counter for how many times it has been answered
208 DOPH S "DONE" to the previous reminder 0 0 32000
Counter for how many times it has been answered
209 LAPH S "REMIND ME LATER" to the previous reminder 0 0 32000
(internal use)
210 MFCL S min 0 0 32000
Guided procedure for installation verify 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
211 FIWZ S 0=Disable 1=Enable 0 0 1
Reminder for water treatment system
ordinary maintenance. Max number of times
212 WTMB U it is possible to answer “REMIND ME 255 0 255
LATER”
0= no postpone admitted
Reminder for water treatment system
ordinary maintenance. Need of store
213 WTMP U password to set to zero (DONE button). 0 0 1
0 = Disabled; 1 = Enabled.
Reminder for water treatment system
214 WTMC S ordinary maintenance: postponing counter 0 0 255

Foglio n° 19/25
This document contains confidential information and is the property of ELECTROLUX PROFESSIONAL Vallenoncello,Italy without whose permission it may not be copied,shown or handed to a third party or otherwise used
and it is to be returned promptly upon request to the ELECTROLUX PROFESSIONAL Vallenoncello,Italy which is responsible for the document.
TITLE
PARAMETER LIST AND ERRORS “TOUCHLINE” OVENS,
SOFTWARE VERSION 6.20 (USER INTERFACE)
MODEL NUMBER REV

ONE 411400009 R.00

NOTE
NOTE N1 Set Fahrenheit (if requested)

NOTE N2 Set altitude above sea level before calibrating the 100°C steam temperature offset.

NOTE N3 Settings are for standard cylindrical micro-perforated metal burners.

NOTE N4 Set 90°C for "UK" models.

NOTE N5 Set 10 for "UK" models.

NOTE N6 Set to 2 (Force half) for "USA GAS 120V" models.

NOTE N7 Set to 20 for "USA GAS 120V" models.

NOTE N8 Set to 20 for "JAPAN GAS 100V" models.

NOTE N9 Set to 1 (Force full) for “USA ELT 208V, 240V and 480V” models.

NOTE N10 Set to 1 (Force full) for "USA GAS 120V" models.
NOTE N12 Set to 2 if the multipoint probe is present (USA lev. K)
NOTE N13 Set the value in brakets for models with additional cleaning system in the cavity fan area

Foglio n° 20/25
This document contains confidential information and is the property of ELECTROLUX PROFESSIONAL Vallenoncello,Italy without whose permission it
may not be copied,shown or handed to a third party or otherwise used and it is to be returned promptly upon request to the ELECTROLUX
PROFESSIONAL Vallenoncello,Italy which is responsible for the document.
TITLE
PARAMETER LIST AND ERRORS “TOUCHLINE” OVENS,
SOFTWARE VERSION 6.20 (USER INTERFACE)
MODEL NUMBER REV

ONE 411400009 R.00

PARAMETERS PROGRAMMING

ENTER IN PARAMETERS PROGRAMMING OF


THE UNIT
1: Press the top button on the left that
shows the current working environment.
2: It will be shown a drop down menu with
the list of available work environments .
3: Press the “Settings”
4: Press the down button to the right "
technical assistance . "
5: Enter the Service Password 1-1-2-3-5-8-1-3
and confirm with the " OK" button.
6: Select the item “Appliance parameters”.
7: You will see the list of machine
parameters including location , unique four-digit
identification code , description ( translated in
all languages ) and current value .
8: Scroll to the desired parameter.
9: To change the value of a parameter press
the corresponding row. It will be shown a pop-
up setting . Set the new value . Press " OK " to
store the new value , " CANCEL " to return
without saving.
10: To exit the parameter programming page,
press the button .

DEFAULT PARAMETERS PROGRAMMING

1: Enter in the Machine Parameters page .


2: Press the up arrow at the bottom center to
display the drawer .
3: Press the button " Default parameters " .
4: A confirmation popup appears.
Press " YES " to load the default parameters
,
" NO " to cancel the operation .

Foglio n° 21/25
This document contains confidential information and is the property of ELECTROLUX PROFESSIONAL Vallenoncello,Italy without whose permission it
may not be copied,shown or handed to a third party or otherwise used and it is to be returned promptly upon request to the ELECTROLUX
PROFESSIONAL Vallenoncello,Italy which is responsible for the document.
TITLE
PARAMETER LIST AND ERRORS “TOUCHLINE” OVENS,
SOFTWARE VERSION 6.20 (USER INTERFACE)
MODEL NUMBER REV

ONE 411400009 R.00

DATA MONITOR PAGE

DATA MONITOR PAGE ACCESS


NOTE: The Data Monitor page is available by
the means of enabling the parameter “97:
DATM”.

1: At any time you can view the Data Monitor


page by pressing the top button on the left that
shows the current working environment.
2: It will be shown a drop down menu with
the list of available work environments .
3: Press the " Data Monitor” for a few
seconds .
4: You will see a page that displays the
status of the internal variables of the oven
operation.
5: Press anywhere on the page to exit and
return to the previous display .

Foglio n° 22/25
This document contains confidential information and is the property of ELECTROLUX PROFESSIONAL Vallenoncello,Italy without whose permission it
may not be copied,shown or handed to a third party or otherwise used and it is to be returned promptly upon request to the ELECTROLUX
PROFESSIONAL Vallenoncello,Italy which is responsible for the document.
TITLE
PARAMETER LIST AND ERRORS “TOUCHLINE” OVENS,
SOFTWARE VERSION 6.20 (USER INTERFACE)
MODEL NUMBER REV

ONE 411400009 R.00

WARNINGS

WARNINGS WITH IMMEDIATE VISIBILITY

The warning icon appears and disappears


automatically to the appearance / disappearance of
the reported situation.

POP-UP WARNINGS

The warning popup appears automatically to the


appearance of the situation reported and remains on
the screen until you press the " OK" button.

WARNING CODE MEANING


Insufficient water pressure for automatic washing system .
EH2O Check the water supply . The oven will continue to clean.
Check the final cleaning result.
Problem to the vent valve .
EFLP The oven will continue to work anyway.
Check the cooking results .
Detected a problem with the oxygen sensor .
ELMB The oven will continue to work anyway.
Check the cooking results .
The optional USB food probe was disconnected . Cooking continues indefinitely .
UPRB
Reconnect the device to restore cooking with USB food probe.

ERROR LIST

Foglio n° 23/25
This document contains confidential information and is the property of ELECTROLUX PROFESSIONAL Vallenoncello,Italy without whose permission it
may not be copied,shown or handed to a third party or otherwise used and it is to be returned promptly upon request to the ELECTROLUX
PROFESSIONAL Vallenoncello,Italy which is responsible for the document.
TITLE
PARAMETER LIST AND ERRORS “TOUCHLINE” OVENS,
SOFTWARE VERSION 6.20 (USER INTERFACE)
MODEL NUMBER REV

ONE 411400009 R.00

The errors relate to reports of serious malfunction of


the machine.

The oven stops the execution of the ongoing cycles .


The error associated functions of the machine
detected are no longer available .

The error popup automatically appears to the


appearance of the situation reported and remains on
the screen until you press the " OK" button.

ERROR CODE MEANING


Cavity overtemperature
ETUC
Cool down the cavity before cooking .
Boiler overtemperature.
ETUB
Cool the boiler before cooking
Main power board over temperature. Check the cooling fan and the air circulation
ESCH
(example the bottom part of the control panel).
ECEL Cavity probe interrupted (it’s possible to use the oven only with steam cycle - 100°C)
EBOL Boiler probe interrupted (it’s possible to use the oven only with convection cycle)
Bypass probe interrupted . The oven will continue to work. The quenching system has
EBYP malfunction and uncertain water spray

NTC probe interrupted. Power board temperature sensor (on board). Replace the power
ENTC
board
Analogic / Digital converter locked. Check input signal of all temperature probes, food probe,
lambda sensor. Verify the oven is correctly set as level Touch or level K by the related
EAD1 .. EAD5(ECAD) parameter APPL.
Replace power board if the problem persist.
EPRB Meat probe interrupted (it’s possible to use only with cooking cycle with time set)
ERTC No communication with the internal clock.
ERAM Communication error with RAM
EPWM Communication error with the PWM system. Burner fan speed control. Replace power board.

Cavity safety thermostat trips. Overtemperature in the cavity (340°C/644°F). Reset the
ETC
thermostat by pushing the red button on it.

ERROR LIST (continues...)


ERROR CODE MEANING
Boiler safety thermostat trips. Overtemperature in the boiler (140°C/284°F). Reset the
ETB
thermostat by pushing the red button on it.
EFUP Thermic protection of the upper cavity motor.

Foglio n° 24/25
This document contains confidential information and is the property of ELECTROLUX PROFESSIONAL Vallenoncello,Italy without whose permission it
may not be copied,shown or handed to a third party or otherwise used and it is to be returned promptly upon request to the ELECTROLUX
PROFESSIONAL Vallenoncello,Italy which is responsible for the document.
TITLE
PARAMETER LIST AND ERRORS “TOUCHLINE” OVENS,
SOFTWARE VERSION 6.20 (USER INTERFACE)
MODEL NUMBER REV

ONE 411400009 R.00


There is an automatic reset of the protection but the user/service must to reset to 0 the
parameter nr.19 ALFN.
Thermic protection of the lower cavity motor.
EFDW There is an automatic reset of the protection but the user/service must to reset to 0 the
parameter nr.19 ALFN.
Water level probe error (probes in short circuit).

ESL If the boiler heating elements or burners are ON for a time over the value defined in
parameter TBON without a water charging phase, this error message is activated. To reset
it, parameter ALFN has to be reset to 0.
PVAL Error due to a wrong value in the parameter list (out of the range)
Default parameters procedure automatically done (example after a replacement of the user
touch).
PDEF
After the default procedure, turn OFF and ON the oven and the error disappears.
Communication error with the main power.
Verify that the green and orange led are blinking together with the oven on.
EPWR If the green led is blinking and the orange is off, the power board must be changed since it is
not responding.
If the orange led is blinking and the green one is off, the user interface must be changed.

Comunication error with the optional USB food probe


EUSB

GAS BURNERS LOCK ALARM

In case of a gas burner lock condition, a warning pop


up appears automatically. The on going cooking
cycle is then stopped, until the locking condition has
been restored to the operational condition of the
burner.

To put back in operation a locked burner, push the


button “RESET BURNERS”.

ERROR CODE MEANING


ECUP Upper cavity gas burner locked.
ECDW Lower cavity gas burner locked.
EBUP Upper boiler gas burner locked.
EBDW Lower boiler gas burner locked.

Foglio n° 25/25
This document contains confidential information and is the property of ELECTROLUX PROFESSIONAL Vallenoncello,Italy without whose permission it