You are on page 1of 6
Roll No: G, PULLA REDDY ENGINEERING COLLEGE (Autonomous): KURNOOL FIRST SESSIONAL EXAMINATIONS - JANUARY 2020 B. TECH VIII - SEMESTER (CIVIL ENGINEERING) (Scheme ~ 2013) ADVANCED FOUNDATION ENGINEERING (AF! Date: 30-01-2020 FN (PE - 3) Time :2 hours Max Marks : 30 Note: 1) Question No. 1 is compulsory and must be answered first in sequence at one place only 2) Answer any Three questions from the remaining 1, a) What is Area ratio? (IM x 6= 6M) ») List out the soil samplers. c) When is the dilatancy correction applied in standard penetration test? 4) According to IS 1904-1978 specifies that all foundations should extend to a depth atleast __ below the natural ground surface. ¢) What is an allowable settlement? 1) Which type of footing is appropriate where the columns and walls are so close that individual footings would overlap or nearly touch each other? 2. a) Explain the standard penetration test and corrections to be applied for SPT. (4M) (CO1) b) A SPT was performed at a depth 15 m in a fine sand deposit with a unit weight of 16 KN/m’ with ‘water table upto ground level. The observed SPT values for every 15 cm depth are 15, 22, 20. Compute the corrected value of N. (4M) (COL) 3. a) Discuss the electrical resistivity method of geophysical exploration. (4M) (CO1) ) Determine the elastic settlement for a footing of 3.5 m x 2 m resting on a clayey soil. Take E, 450 kg/om?, j= 0.4 and footing carries a load of 2500 KN. Take Iw = 0.86 (Rigid). (4M) (CO3) 4, a) What are the types of shallow foundations? Explain briefly with neat sketches. (4M) (CO2) b) How to fix the depth and spacing of footings? (4M) (CO2) 5. a) What are the types of mat foundation? Explain them briefly. (4M) (CO3) ) The inner and outer diameters of a sampling tube are 70 mm and 72 mm respectively, and that of a cutting edge inner and outer diameters are 68 mm and 74 mm respectively. Determine the area ratio, inside clearance and outside clearance of the sampler. (4M (Con) 6. a) Describe the Pressuremeter test conducted in soil investigation. (4M) (CO1) ) Explain in detail about the foundations in sands and clays. (4M) (CO2) ROLLNOL G.PULLA REDDY ENGINEERING COLLEGE (AUTONOMOUS): KURNOOL FIRST SESSIONAL EXAMINATIONS ; JANUARY-2020 B.TECH VIII SEMESTER EXAMINATION DEPARTMENT OF CIVIL ENGINEERING ADAVNCED STRUCTRUAL DESIGN (ASD) (SCHEME-2013) Date: 27.01.2020 ‘Time: 2Hours Max. Marks: 30 NOTE: 1) Question No.1 is compulsory and it must be answered first in sequence at one place only 6a) 2) Answer any THREE questions from remaining 3) Any data if necessary may be assumed suitably 6x1=6 a. AS per IS 875-1987(par-I1) what is the magnitude of live load on stair case of public building likely to be over crowded. ». Write the formula for dead load of waist slab in case of star case on the horizontal plane, ¢. State the circumstances in which combined footing is used, 4. Combined footing is designed in such a manner that centre of gravity of footing should coincide with —-------- of combined loads of two columns ©; What is the general ratio used between base of cantilever retaining wall to the height of wall. £. What is shear key and explain Design a dog legged stair case for a building in which the vertical distance between floors is 3.6m. The stair case hall measures 2.5m X 5m. The live load may be taken as 3kN/m?,Use M20 grade concrete and Fe 415 grade steel. Use limit state method of design, 8M(CO1) Design a suitable open well type stair case for multistoried building having space for stair case 3.25m X_3.25m.Height between floors is 3m. The live load may be taken as 4 kN/m?. Use M20 grade concrete and Fe415 grade . Use limit state method of design, 8M(CO1) Design a rectangular combined footing for two columns 450mm X 450mm and 600mm X 600mm carrying 800kN and 1000kN respectively. The columns are located 4m apart, The SBC of soil 200kN /m?,Use M20 grade concrete and Fe415 grade steel, Use limit state method of design. 8M(CO2) Design a cantilever retaining wall to retain level earth back fill of 3m above basement level, The angle of repose of soil is 30”.The unit weight of soil is 16kN/m°.The coefficient of friction between soil and concrete is 0.6.The SBC of soil is 100kN/m? at a depth of 1m below the basement level Use M20 grade concrete and Fe415 grade steel. Use limit state method of design 8M(CO3) Explain in detail about the stability of retaining wall. 4M(CO3) Explain one way and two way shear failure criterias in combined footings, 4M(Co2) Roll No. - G,Pulla Reddy Engineering College (Autonomous): Kurnool First Sessional Examinations, January 2020 B.Tech VIII Semester Civil Engineering CE 409: Water Resources Engineering — III (W! RE3) (Scheme ~ 2013) Date: 28-01-2020 Time: 10A.M to 12 Noon Duration: 2 Hours Max. Marks: 30 Note: 1. Answer any ONE question. 2. Assume any missing data required suitably. 1. Design the surplus work of a tank forming part of a chain of tanks. The combined catchment area of the group of tanks is 25.89 km? and the area of the catchment intercepted by the upper tanks is 20.71 km. It is decided to store water in the tank to a level of +12.00 m above M.S.L. (Mean Sea Level) limiting the submersion of foreshore lands up to a level of +12.75 m above M.S.L. The general ground level at the proposed site of work is +11.00 m and the ground level below the proposed surplus slopes off till it reaches +10.00 m in about 6 m distance, The tank bund has a top width of 2 m at level +14.50 m with side slopes on either side. The tank bunds are designed for a saturation gradient of 4:1 with 1 m clear cover. Provision may be made to make Kutcha regulating arrangements to store water up to M.W.L. at times of necessity. The foundations are of hard gravel at a level of +9.5 m near the site of work. Draw to a suitable scale the following: i) Half plan at top and half plan at foundation level and i) Section across the Weir 0) (C01, C03, CO4) 2. Design a sluice taking off from a tank irrigating 200 hectares at 1000 duty. The tank bund through which the sluice taking off has a top width of 2 m with 2:1 side slopes. The top level of bank is +40.00 and the ground level at site is +34.50. Good hard soil for foundation is available at +33.50.The sill of the sluice at off take is +34.00. The maximum water level in the tank is +38.00. The full tank level is +37.00, Average low water level of the tank is +35.00. The details of the channel below the sluice are as under. Bed Level: +34.00 F.S.L. 34.50 Bed width :1.25m Side slopes 3 to 1 with top of bank at +35.50. Draw to a suitable scale the following: 4) Half plan at top and half plan at foundation level and i) Longitudinal Section G0) (CO1, C03, COS)

You might also like