Professional Documents
Culture Documents
item UL CSA
location part No. description type make comment
No. certificate No. certificate No.
proximity switch E87056 1007121
1 pump 413347 NCB5-18GM40-N0-V1 Pepperl & Fuchs
gate valve (E139396) (LR96321-2)
proximity switch E87056 1007121
2 pump 413347 NCB5-18GM40-N0-V1 Pepperl & Fuchs
S-transfer tube drive (E139396) (LR96321-2)
connector f. C UL US
3 pump 516605 V1-W-N-25M-PUR Pepperl & Fuchs E231213 not required
proximity switch certificate
terminal box pump
4 pump 251116002 8146/2041 R. Stahl E177642 1309971
(i.s. blue)
430416 / cable glands
5 pump 8161 R. Stahl not available LR9948018
430411 on terminal box pump
electric wire 1185170
6 pump 504688 Ölflex-150 2x1 Lapp Kabel E63634
(i.s. blue) (LL 53776-6)
electric wire 1185170
7 pump 504687 Unitronic LiYCY A 5 AWG 27 Lapp Kabel E63634
(grey) (LL 53776-6)
1784452
8 pump 491365 conduit PMAFLEX PCLT-23B PMA AG E80294
(LL 88703-1)
1784452
9 pump 491364 conduit PMAFLEX PCLT-17B PMA AG E80294
(LL 88703-1)
W22 TRU METRIC IEC IE3
10 HPP 585769 E-motor 11,0 kW WEG E104590 1619832
NEMA PREMIUM
002262_C_000
11 HPP 586061 E-motor for oil-air-cooler NEC Motor, Baldor Baldor E46145
(022553)
Mobrey /
Squing II
12 HPP 287900004 oil level switch Emerson Process not available 040796_0_000
2120D 1A C 1|1 A L
Management GmbH
UL_CSA_Zertifikate.pdf
client: Thermtech AS UL-Certificates
proj. Thermtech Canada Rev.01
comm: 20361345/20361346 CSA-Certificates Date: 2013-Nov-05th
editor: T. Mueller
6233-01
00837_0
E186708 6233-01
all individual
E102079 0185753_0
Bühler components of
13 HPP 581200 oil temperature switch TSK-1 E70063 3105897
Technologies this device are
E166011 4823-02
certified
E242293 067165_0
5835-01
70200
valve: DKZA/UL-T-151-L3/NPT/BC C UL US
14 HPP 561449 Prop. ctrl. valve NG10 Atos S.p.a. E192514 not required
solenoid: OZAUL-T certificate
cable gland
15 HPP 585358 CMP-20s/16-A2F CMP Products not available 1211841
on hydr. valve
valve: DHA/UL-0631/2/NPT/A 24DC C UL US
16 HPP 561448 way valve NG6/24V Atos S.p.a. E192514 not required
solenoid: OAUL certificate
valve: DHA/UL-0711/NPT 24DC C UL US
17 HPP 585048 way valve NG6/24V Atos S.p.a. E192514 not required
solenoid: OAUL certificate
terminal box HPP
18 HPP 256824001 8146/1041 R. Stahl E177642 1309971
(non i.s. black)
electric wire 1185170
19 HPP 586151 Ölflex-150 Lapp Kabel E63634
(non-i.s. black) (LL 53776-6)
terminal box HPP
20 HPP 251116002 8146/2041 R. Stahl E177642 1309971
(i.s. blue)
electric wire 1185170
21 HPP 504688 Ölflex-150 2x1 Lapp Kabel E63634
(i.s. blue) (LL 53776-6)
electric wire 1185170
22 HPP 504687 Unitronic LiYCY A 5 AWG 27 Lapp Kabel E63634
(grey) (LL 53776-6)
1784452
23 HPP 491365 conduit PMAFLEX PCLT-23B PMA AG E80294
(LL 88703-1)
1784452
24 HPP 491364 conduit PMAFLEX PCLT-17B PMA AG E80294
(LL 88703-1)
430416 / cable glands
25 HPP 8161 R. Stahl not available LR9948018
430411 on terminal box HPP
UL_CSA_Zertifikate.pdf
client: Thermtech AS UL-Certificates
proj. Thermtech Canada Rev.01
comm: 20361345/20361346 CSA-Certificates Date: 2013-Nov-05th
editor: T. Mueller
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.html?utm_source=ulcom&utm_medium=web&utm_campaign=database
http://www.csagroup.org/ca/en/services/testing-and-certification/certified-product-listing
UL_CSA_Zertifikate.pdf
UL_CSA_Zertifikate.pdf
PMArt.-N 41347Pep rlpoximtyswitchULcertE87056
NRKH.E87056
Proximity Switches
Page Bottom
Proximity Switches
Controllers, Models IC-KP-, IC-KP1-, IC-KP2- followed by additional letters and/or numbers.
Multiple proximity switch system, Cat. No. PLVScan followed by P, T, R, followed by 08, 16, 24, 32, 40, 48, 56, 64, followed by characters.
Photo electric sensors, Cat. Nos. VL18-6-L/32/40b, -L/32/40b/73, -LS/32/40b, -LS/32/40b/73, VL18-54-M/32/40b/92, -MS/32/40b/92,
VS/VSE18-M/32/40b/92, -MS/32/40b/92, VS18/VSE18-L/32/40b/73, -LS/32/40b, -LS/32/40b/73, VT18H-M/32/40b/92, -MS/32/40b/92,
VT18L/32/40b, -L/32/40b/73, -LS/32/40b, -LS/32/40b/73, VT18-M/32/40b/92, -MS/32/40b/92.
Photoelectric sensing devices, Series CP18 Model No. CP18, followed by 54, 6, 8, A, D or none, followed by 80, 300 or none, followed by LS,
followed by 25, 40b, 59 or none, followed by *115 or 73c, followed by 142, 147, or none.
Proximity sensors, Model 972A or 973A followed by A, B or C, followed by 2, 3 or 4, followed by J, H or X, followed by M or P, followed by A or
B, followed by 3 or 7, followed by N, P or T, followed by L, with or without three digit number; Cat. No. SDS-C1 thru -C9 followed by -A or -B,
followed by HM-A8 followed by D or N.
Proximity switches, Cat. No. 40FY followed by 22, 24, 26 or 28, followed by -020 or -33, may be followed by H; Cat. No. 976 followed by A,
followed by A, followed by 2, 3 or 4, followed by H, followed by I, followed by A, followed by 3, followed by T, followed by LF5 or LF7; Cat. No.
993 followed by A, followed by A or B, followed by 12, 18 or 30, followed by A or B, followed by T, followed by B2, B5, B10, HA or J; Model C, IA,
HDM-H, DF12, DK12, M, MA14, MD14, MLV14, M5, MV5, ML5, M7, ML7, M71, ML71, ME7, MVE7, MLE7, MV71, M8, ML8, MV8, ML18, M9, MS32,
ML9, MV9, M40, MV40, MLV40, M41, MV41, MLV41, M100, MV100, ML100, GD18, GV18, GLV18, GL, GLE, FLT-D, LS610-DA, LS611-DA, RL28,
RLG28, LD28, LV28, M4.1, MV4.1, ML4.1, M4.2, MV4.2, ML4.2, M6, MV6, ML6, ST-H.1, ST-54.1, MV7, M12, MV12, MLV12, RL29, LD29, LT6,
LV29, VDM28, VDM70, SU, VDM100, WTS10, N, O, P, R, S or U followed by a number/letter combination; Cat. No. MHP followed by C1, C2, CG1,
CG2, D, DR, F, FG, FR, LR, P, R, TE, TLE, TR, TLR or WD, followed by 30, 31, 32 or 33, followed by L or Q, may be followed by numbers, may be
followed by D or LO; Cat. No. SDS followed by C2, followed by 1 thru 9, followed by MPH, followed by C1, C2, D, F, FR, P or R, followed by G;
Cat. No. SVP followed by 1, followed by C, D, P, R or T, followed by I or R, followed by D or L, followed by A, followed by C or Q, may be followed
by additional letters and/or numbers .
Model M, followed by L, D, V, followed by 17, may be followed by -8, -8-H, -8-HW, -8-HS, -8-HGU, -8-V, -6, -54, -LL-K, -54-G, -55, -55-G,
-LL-G, may be followed by -50, -100, -150, -450, or any numbers, may be followed by -RT, -IR, or blank, followed by one or more of the
following /33, /73, /82b, /115, 115xx, /115a, /115axx, /115b, /115bxx, /120, /126a, /127, /136, /137, /143, (where xx = letter/number
combination), /a 2 or 3 digit letter/number combination, may be followed by 2, 3, 4, 5, 6, or 7 digit letter/number combination, may be followed
by B.
Proximity switches for connection to Class 2 power supply only, Series M5, MA14, MD14, ML5, MV5, MV14, MLV14, O, U, ACX, ACY, INX
or INY followed by any number/Letter combination.
Proximity switches for connection to Class 2 power supply only, Series LD, LV, RL, RLG, RL28, RLG28, LV28, LD28, LT, M, MS, MV, ML,
MLV, GD, GV, GLV, GL, GLE, DK, DF, ST-54.1, ST-H.1, HDM-H, SU, LS610-DA, LS611-DA, FLT, VDM, WTS, ME7, MVE7, MLE7; may be followed
by any number; may be followed by -6, -6-G, -8, -8-H,-8-HW, -8-HS, -8-HGU, -8-V, -8-HV, -8-W, -54, -54-G, -55, -55-G, -P, -T, -R, -LL; may be
followed by any number and/or letter combination, or a number range consisting of two sets of numbers separated by a "-"; may be followed by
-AS-I, -E, -F, -IR, -L, -RT, -UV, -LAS, -3K, -P, -IBS, -EIP, -PN, -SSI, -EHB, -IO, -F1, -F2, -F3, -F4, -D, -LL-G, -LL-K, -R, -Z, -A, -S, -M, -MS, -S,
-B3B, -FFP, -PCB, -R1, -L1, -MD, -SD, or -V; followed by a number/letter combination, followed by Yxxxxxx.
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?nam... UL_CSA_Zertifikate.pdf
05.11.2013
NRKH.E87056 - Proximity Switches Seite 2 von 2
Cat. Nos. RL31, LV31, LD31, LA61, LD61, LK61, LV61, RL61, RLK61, GLK18, GA18 and GK18, followed by numbers or letters.
Cat. Nos. SLVA-4K plus, SLVA-8K, SC4-8, followed by 24, 115 or 230; Cat. Nos. SLA5, SLA20, SLA25, SLA40 may be followed by E or S, may be
followed by 35 or 92; Cat. No. SLP, followed by 10, 30 or 65, followed by numbers; Cat. No. VSL may be followed by A, followed by 24, 110, 220,
240; Cat. Nos. LS 5-TE LSS, 5S TE-LSE, LS 5S-TE LSS, LS 5S-TE, MV 40/43-TE, MLV 15, M15/MV15, MLV40, M40/MV40, RL23, RLK 23,
L24/LV24, RL25, RLK 25, L25/LK25, L25/LV25, RL 28, RL32, GLV 30, G30/GV30, DK10, DK20, ML4.1, SU 14, LT, LTK, RL91, RLK91, LT2000-2K,
GLV 30 followed by numbers and/or letters; Cat. No. VCS110.
Cat. Nos. RLK28, LK28, LA28, RLK29 followed by numbers and/or letters.
Cat Nos. ML7, ML8, ML71, MV7, MV71, M7, M71 followed by numbers and/or letters.
Cat. Nos. SBL-8-H, SBL-8-H-SL, SBL-8-H-SL-V, SBL-8-SL-V-Z followed by numbers and/or letters.
Cat. Nos. M, ML, MV followed by 4.1, 4.2 or 6, followed by numbers and/or letters.
Type 3RG7 followed by 40 or 42, followed by 0, 1, 2, followed by -0, -3 or -7, followed by A or G, followed by A or B, followed by two numbers.
Type 3RG7 followed by 64 or 65, followed by 0, 1, 2, followed by -0, -3, followed by A, B, C, G, H, followed by A, B, C, D, G, followed by two
numbers.
Proximity switch system, Cat. No. LGM or LGS followed by any number, may be followed by IO, RT, F1, F2 or 2 digit alpha numeric number,
may be followed by a 4 digit number, may be followed by "/", followed by any alpha numeric number combination.
Proximity switch, as-interface modules, Cat. No. VAA or VBA, followed by a combination of letters and/or numbers may be followed by G2,
G11, G12, G16, KE, KE1, KF, KF2, K2 or K3, may be followed by a combination of letters and /or numbers.
Proximity switches, class 2 interface modules, Cat. No. VAA or VBA, followed by a combination of letters and/or numbers followed by G4
may be followed by a combination of letters and /or numbers.
Proximity type, Smarteye Series, Cat. Nos. 911540, 911541, 911542, 912568, 912569, 912570, 912571, 912572, 912573, 912574.
Sensors, Models IPH-, MVH-, ISH-, IQH-, IUH-, IPH1-, ISH1-, IQH1-, IUH1-, IPT1-, IST1-, IQT1-, IUT1-, MVH1, IRH-, IVH-, MVT-, IPT-, IST-,
IUT-, IQT- followed by additional letters and/or numbers.
Proximity Switches, Laser Class 2, Optical Data Coupler, Models LS680-DA-EN/F2, LS680-DA-EN/F1, may be followed by /XX or /XXX
combination, where X = a letter/number combination.
© 2013 UL LLC
When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment
database for additional information regarding this product's certification.
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up
Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-
misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with
permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the
following format: "© 2013 UL LLC".
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?nam... UL_CSA_Zertifikate.pdf
05.11.2013
PMArt.-Nr.413 47 Pep erlproximtyswitchCSAcertE10 712
Certificate of Compliance
Certificate: 1007121 (LR 96321-2) Master Contract: 159754
T. Munteanu
Issued by: T. Munteanu, P.Eng.
PRODUCTS
CLASS 3211 83 - INDUSTRIAL CONTROL EQUIPMENT-Motor Controllers - Auxiliary
Devices-Certified to U.S. Standards
CLASS 3211 03 - INDUSTRIAL CONTROL EQUIPMENT - Motor Controllers - Auxiliary
Devices
Notes:
APPLICABLE REQUIREMENTS
CAN/CSA-C22.2 No. 0 - General Requirements - Canadian Electrical Code, Part II
CAN/CSA-C22.2 No. 14 -Industrial Control Equipment (Approved March 2006)
UL_CSA_Zertifikate.pdf
Certificate: 1007121 (LR 96321-2) Master Contract: 159754
MARKINGS
UL_CSA_Zertifikate.pdf
PMArt.-N 41347Pep rlpoximtyswitchULcertE139 6
OERX2.E139396
Equipment and Systems for Use in Hazardous Locations - Component
Page Bottom
See General Information for Equipment and Systems for Use in Hazardous Locations - Component
Associated apparatus nonhazardous locations.Model KM/EX isolation module providing intrinsically safe circuits for use in Class
I, Groups A, B, C and D ; Class II , Groups E, F and G ; and Class III hazardous locations.
Class I, Groups A, B, C and D; Class II, Groups E, F and G; Class III.Model CCRM resistive module, intrinsically safe for use in
hazardous locations.
Proximity sensors, intrinsically safe for use in hazardous locations, Model CJ followed by a number, followed by a hyphen and a
number and/or letter combination, followed by -1N, -N, -N0, -N1, -N2, -N4, -SN, -S1N, -YN, may be followed by -BHMS3, -BHMSP3,
-G, -V, -V1, -V3, -Z1D. Models NBB, NBN, NCB, NCN, NEB, NEN, NJ followed by a number, followed by a hyphen and a number
and/or letter combination, followed by -1N, -N, -N0, -N1, -N2, -N4, -SN, -S1N -YN, may be followed by BHMS3, -BHMSP3, -G, -V, -
V1, -V3, -Z1D. Model NJ followed by a number, may be followed by P, S, S1, followed by + and a number and/or letter
combination, followed by +1N, +N, +N0, +N1, +N2, +N4, +SN, +S1N, +YN, may be followed by -BHMS3, -BHMSP3, -G, -V, -V1, -
V3, -Z1D. Model RJ followed by a number, may be followed by a hyphen and a number and/or letter combination, followed by -1N, -
N, -N0, -N1, -N2, -N4, -SN, -S1N, -YN. Models SB, SC, SJ followed by a number, may be followed by a hyphen and a number
and/or letter combination, followed by -1N, -N, -N0, -N1, -N2, -N4, -SN, -S1N, -YN .
© 2013 UL LLC
When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL
Environment database for additional information regarding this product's certification.
The appearance of a company's name or product in this database does not in itself assure that products so identified have been
manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and
covered under UL's Follow-Up Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The
Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and
in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online
Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material
must include a copyright notice in the following format: "© 2013 UL LLC".
UL_CSA_Zertifikate.pdf
http://database.ul.com/...+Component&objid=1073770125&cfgid=1073741824&version=versionless&parent_id=1073770104&sequence=1[23.10.2013 10:59:49]
UL_CSA_Zertifikate.pdf
PMArt.-N 51605conectorp ximtyswichUL-certE231
CYJV2.E231213 - Cable Assemblies and Fittings for Industrial Control and Signal Distribution - Component
PM Art.-Nr. 516605 connector proximity switch UL-cert E231213
CYJV2.E231213
Cable Assemblies and Fittings for Industrial Control and Signal Distribution - Component
Page Bottom
Cable Assemblies and Fittings for Industrial Control and Signal Distribution - Component
See General Information for Cable Assemblies and Fittings for Industrial Control and Signal Distribution - Component
Cord assembly, Cat. No. V1, V11, V1S, V11S, V3, V3S, V15, V15S, V17, V17S, V19, V19S, V31 or V31S followed by -G, -W, -
GM or -WM, may be followed by V2A or V4A, may be followed by -E2, -E2/E3, -A2, -E8, -E8W, or -S or blank, followed by xxxxM,
where xx may be any color or xx may be any number, followed by -PUR or -PVC, may be followed by -UL, -U, -ABG, -0.75, -H/S, -
U/ABG, -U/0. 75, U75/ABG, -U/S, or -Amay be followed by -xx for customer specific order.
Cable assembly, extension cable, Cat. No. V1, V3, V11, V15, V17, V19 or V31 followed by -G, -W, -GM or -WM, may be
followed by V2A or V4A, may be followed by -E2, -E2/E3, -A2, -E8, -E8W, or -S or blank, followed by -xxxxM, where xx may be any
color or xx may be any number, followed by -PUR or -PVC, may be followed by -UL, -U,-ABG, -0.75, -H/S, -U/ABG, -U/0.75, -
U75/ABG, -U/S, or -A, may be followed by -V1, -V3, -V11, -V15, -V17, -V19 or -V31, followed by -G, -W, -GM or -WM, may be
followed by V2A or V4A, may be followed by -xx for customer specific order.
Micro-AC Series:
Micro DC Series:
Male receptacles with ½"-18NPT threads, Cat. Nos. 1/2" NPT-V1-G-S-zz, 909790, 1/2" NPT-V15-G-S-zz.
Female receptacles with ¼"-18NPT threads, Cat. Nos. 1/2" NPT-V1-G-zz, 1/2NPT-V1-G-S-zz.
MIN Series:
Male receptacles, size I, Cat. Nos. 900349, 902417, 900351, 1/2NPT-V93-G-S-zz, 1/2NPT-V93A-G-S-zz, 1/2NPT-V93A-W-S-zz,
1/2NPT-V93-W-S-zz, 909399, 1/2NPT-V94-G-S-zz, 909400, 902198, 184283, 185953, 1/2NPT-V95-G-S-zz, 1/2NPT-V95-G-S-zz-
22AWG, 1/2NPT-V95A-G-S-zz, V9-R-M-A, V9-R-M-S, PG11-V95-G-S-zz.
Male receptacles, size I with metric threadings, Cat. Nos. M16-V93-G-S-zz, M16-V94-G-S-zz, M16-V95-G-zz, M16-V95-G-S-
zz, 907526.
Female receptacles, size I with metric threadings, Cat. Nos. M16-V93-G-zz, M16-V94-G-zz, 907527.
Male receptacles, size I with PG threadings, Cat. Nos. 907747, 907290, 907677.
Female plugs, size I, Cat. Nos. V93-G-YEzz-STOOW, V93-W-YEzz-STOOW, MINI-3G-zz-SS, V94-G-YEzz-STOOW, V94-W-YEzz-
UL_CSA_Zertifikate.pdf
http://database.ul.com/...+Component&objid=1076286708&cfgid=1073741824&version=versionless&parent_id=1073747855&sequence=1[23.10.2013 11:10:47]
CYJV2.E231213 - Cable Assemblies and Fittings for Industrial Control and Signal Distribution - Component
Min Series, male plugs, size I, Models V93-G-SE, V93-G-SI, V94-G-SE, V94-G-SI, V95-G-SE, V95-G-SI.
© 2013 UL LLC
When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL
Environment database for additional information regarding this product's certification.
The appearance of a company's name or product in this database does not in itself assure that products so identified have been
manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and
covered under UL's Follow-Up Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The
Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and
in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online
Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material
must include a copyright notice in the following format: "© 2013 UL LLC".
UL_CSA_Zertifikate.pdf
http://database.ul.com/...+Component&objid=1076286708&cfgid=1073741824&version=versionless&parent_id=1073747855&sequence=1[23.10.2013 11:10:47]
PMArt.-N 251 602StahlTerminalboxpum8146ULcertE17642V1S
BGYM.E177642
Boxes, Junction and Pull for Use in Zone Classified Hazardous Locations
Page Bottom
Boxes, Junction and Pull for Use in Zone Classified Hazardous Locations
See General Information for Boxes, Junction and Pull for Use in Zone Classified Hazardous Locations
© 2012 UL LLC
When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment
database for additional information regarding this product's certification.
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up
Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of
the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent
to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2012 UL LLC".
UL_CSA_Zertifikate.pdf
BGYM7.E177642
Boxes, Junction and Pull for Use in Zone Classified Hazardous Locations Certified
for Canada
Page Bottom
Boxes, Junction and Pull for Use in Zone Classified Hazardous Locations Certified
for Canada
See General Information for Boxes, Junction and Pull for Use in Zone Classified Hazardous Locations Certified for Canada
© 2012 UL LLC
When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment database
for additional information regarding this product's certification.
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up
Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the
data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the
extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2012 UL LLC".
UL_CSA_Zertifikate.pdf
QBCR.E177642
Outlet Boxes for Use in Hazardous Locations
Page Bottom
See General Information for Outlet Boxes for Use in Hazardous Locations
© 2012 UL LLC
When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment database
for additional information regarding this product's certification.
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up
Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the
data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the
extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2012 UL LLC".
UL_CSA_Zertifikate.pdf
QBCR7.E177642
Outlet Boxes for Use in Hazardous Locations Certified for Canada
Page Bottom
See General Information for Outlet Boxes for Use in Hazardous Locations Certified for Canada
© 2012 UL LLC
When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment database
for additional information regarding this product's certification.
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up
Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the
data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the
extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2012 UL LLC".
UL_CSA_Zertifikate.pdf
PMArt.-N 251 602 StahlTerminalboxpum 8146CSAcert130971
PM Art.-Nr. 251116002 Stahl Terminal box pump 8146 CSA cert 1309971
Certificate of Compliance
Certificate: 75-GGE7 Master Contract: 7E7-,-
The products listed below are eligible to bear the CSA Mark shown
Issued by:
PRODUCTS
CLASS 3218 01
!"#
$% $&
,-E1B-7B-,BB @:7
UL_CSA_Zertifikate.pdf
Certificate: 75-GGE7 Master Contract: 7E7-,-
APPLICABLE REQUIREMENTS
= 2
$!
$B0 $2
2 $?@>$! 2
$$ >4!
$2&
=$>$!
2)--EG$ & $& (BB1B$ & $& (
$+
=1
8H
1)--EG-77$ 44 $ 2
$'4
@ !
4=$ 1I$ $>$! 1
8H
1)--EGE7B$ 44 $ 2
$'4
@ !
4=$ 1$ & 231
8H)7B07-B$ 44 $ 2
$ =4$
2
!+ +& 1
,-E1B-7B-,BB @:B
UL_CSA_Zertifikate.pdf
PMArt.-N 4301/43016cable-gandtype816 StahlCSA-certLR9480-26
UL_CSA_Zertifikate.pdf
UL_CSA_Zertifikate.pdf
UL_CSA_Zertifikate.pdf
UL_CSA_Zertifikate.pdf
PM Art.- Nr. 50468 Lap Oilfex-150 UL-cert E63634
8/$SSUREDWLRQ
IU86$
)LUPD
8,/$33*PE+6WXWWJDUW
UL_CSA_Zertifikate.pdf
UL_CSA_Zertifikate.pdf
PMArt.-N 50468 Lap Oilfex-150CSA-cert18570
Certificate of Compliance
Certificate: 1185170 (LL 53776-6) Master Contract: 154019
The products listed below are eligible to bear the CSA Mark shown
PRODUCTS
CLASS 5851 01 - WIRES - Appliance
UL_CSA_Zertifikate.pdf
Certificate: 1185170 (LL 53776-6) Master Contract: 154019
APPLICABLE REQUIREMENTS
UL_CSA_Zertifikate.pdf
PMArt.-Nr504687Lap KabelUnitro cLiYC SA-cert185170
Certificate of Compliance
Certificate: 1185170 (LL 53776-6) Master Contract: 154019
The products listed below are eligible to bear the CSA Mark shown
PRODUCTS
CLASS 5851 01 - WIRES - Appliance
UL_CSA_Zertifikate.pdf
Certificate: 1185170 (LL 53776-6) Master Contract: 154019
APPLICABLE REQUIREMENTS
UL_CSA_Zertifikate.pdf
PMArt.-Nr.504687Lap KabelUnitronicLiYCYUL-certE63 4
8/$SSUREDWLRQ
IU86$
)LUPD
8,/$33*PE+6WXWWJDUW
UL_CSA_Zertifikate.pdf
UL_CSA_Zertifikate.pdf
PMArt.-N 491365PMAconduitPCLT-23BUL-certE80294
YDRQ8.E80294 - Tubing, Mechanical Protection Certified for Canada - Component Seite 1 von 1
PM Art.-Nr. 491365 PMA conduit PCLT-23B UL-cert E80294
YDRQ8.E80294
Tubing, Mechanical Protection Certified for Canada - Component
Page Bottom
See General Information for Tubing, Mechanical Protection Certified for Canada - Component
Fittings, Type PMAFIX PRO designated "KNH" (Nickel Plated Brass and Plastic Threads), "KAH" (Nickel Plated Brass and Plastic Threads),
"KBH" (Nickel Plated Brass and Plastic Threads), "KIHG" (Plastic Threads), "KIS" (Nickel Plated Brass Threads), "KNZ PFLITSCH", and "KNZ
Jacob".
Type PMAFIX PRO designated "KNH" (Nickel Plated Brass and Plastic Threads), "KAH" (Nickel Plated Brass and Plastic Threads), "KBH" (Nickel
Plated Brass and Plastic Threads), "KIHG" (Plastic Threads), "KIS" (Nickel Plated Brass Threads), "KNZ PFLITSCH", and "KNZ Jacob".
Marking: Company name or tradenames "PMAFLEX", "EASIFLEX", "SMART-LINE", "PMA FLEXPLus", "EASIFIX", "ECOFIX", "ECONOMY", "PMAFIX",
"PMAGRIP& PMA FIXPLus", "PMAJACK", "PMAFLEX Pro", "PMAFIX PRO", product designation, temperature rating and the Recognized Component
© 2013 UL LLC
When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment
database for additional information regarding this product's certification.
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up
Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-
misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with
permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the
following format: "© 2013 UL LLC".
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?nam... UL_CSA_Zertifikate.pdf
06.11.2013
UL_CSA_Zertifikate.pdf
PMArt.-N 491365PMAconduitPCLT-23BCSA-cert178452
Certificate of Compliance
Certificate: 1784452 (LL88703-1) Master Contract: 181020
The products listed below are eligible to bear the CSA Mark shown
with adjacent indicators 'C' and 'US' for Canada and US or with
adjacent indicator 'US' for US only or without either indicator for
Canada only.
PRODUCTS
CLASS 1853 81 - TUBING - Flexible, Nonmetallic - Certified to US Standards
CLASS 1853 01 - TUBING - Flexible, Nonmetallic
!
"
#$% &&$' (
&')&*
&+,-.
UL_CSA_Zertifikate.pdf
Certificate: 1784452 (LL88703-1) Master Contract: 181020
/
!
''.' . ''7.#$9 &:;:
(*
UL_CSA_Zertifikate.pdf
PMArt.-N 491364PMAconduitPCLT-17BUL-certE80294
YDRQ8.E80294 - Tubing, Mechanical Protection Certified for Canada - Component Seite 1 von 1
YDRQ8.E80294
Tubing, Mechanical Protection Certified for Canada - Component
Page Bottom
See General Information for Tubing, Mechanical Protection Certified for Canada - Component
Fittings, Type PMAFIX PRO designated "KNH" (Nickel Plated Brass and Plastic Threads), "KAH" (Nickel Plated Brass and Plastic Threads),
"KBH" (Nickel Plated Brass and Plastic Threads), "KIHG" (Plastic Threads), "KIS" (Nickel Plated Brass Threads), "KNZ PFLITSCH", and "KNZ
Jacob".
Type PMAFIX PRO designated "KNH" (Nickel Plated Brass and Plastic Threads), "KAH" (Nickel Plated Brass and Plastic Threads), "KBH" (Nickel
Plated Brass and Plastic Threads), "KIHG" (Plastic Threads), "KIS" (Nickel Plated Brass Threads), "KNZ PFLITSCH", and "KNZ Jacob".
Marking: Company name or tradenames "PMAFLEX", "EASIFLEX", "SMART-LINE", "PMA FLEXPLus", "EASIFIX", "ECOFIX", "ECONOMY", "PMAFIX",
"PMAGRIP& PMA FIXPLus", "PMAJACK", "PMAFLEX Pro", "PMAFIX PRO", product designation, temperature rating and the Recognized Component
© 2013 UL LLC
When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment
database for additional information regarding this product's certification.
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up
Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-
misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with
permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the
following format: "© 2013 UL LLC".
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?nam... UL_CSA_Zertifikate.pdf
06.11.2013
UL_CSA_Zertifikate.pdf
PMArt.-N 491364PMAconduitPCLT-17BCSA-certifcae178452
Certificate of Compliance
Certificate: 1784452 (LL88703-1) Master Contract: 181020
The products listed below are eligible to bear the CSA Mark shown
with adjacent indicators 'C' and 'US' for Canada and US or with
adjacent indicator 'US' for US only or without either indicator for
Canada only.
PRODUCTS
CLASS 1853 81 - TUBING - Flexible, Nonmetallic - Certified to US Standards
CLASS 1853 01 - TUBING - Flexible, Nonmetallic
!
"
#$% &&$' (
&')&*
&+,-.
UL_CSA_Zertifikate.pdf
Certificate: 1784452 (LL88703-1) Master Contract: 181020
/
!
''.' . ''7.#$9 &:;:
(*
UL_CSA_Zertifikate.pdf
PMArt.-N 58769WEG lectriMotrs1kWUL-certifaeE10459
ZWKG.E104590 - Electric Motors Certified for Energy Efficiency PM Art.-Nr. 585769 WEG Electric Motors 11kW UL-certificate E104590
ZWKG.E104590
Electric Motors Certified for Energy Efficiency
Page Bottom
See General Information for Electric Motors Certified for Energy Efficiency
Verified for energy efficiency in accordance with 10CFR, Part 431, dated October 1999.
1.5 2 82.5
2 2 84
3 2 85.5
5 2 87.5
7.5 2 88.5
10 2 89.5
15 2 90.2
20 2 90.2
25 2 91
30 2 91
40 2 91.7
50 2 92.4
ET Series TEFC 60 2 93
75 2 93
100 2 93.6
125 2 94.5
150 2 94.5
200 2 95
1 4 82.5
1.5 4 84
2 4 85.5
3 4 87.5
5 4 87.5
7.5 4 89.5
10 4 90.2
15 4 91
UL_CSA_Zertifikate.pdf
http://database.ul.com/...y+Efficiency&objid=1075219759&cfgid=1073741824&version=versionless&parent_id=1073996576&sequence=1[23.10.2013 11:28:52]
ZWKG.E104590 - Electric Motors Certified for Energy Efficiency
20 4 91
25 4 92.4
30 4 92.4
40 4 93
60 4 93.6
75 4 94.1
100 4 94.5
125 4 94.5
150 4 95
200 4 95
1 6 80
1.5 6 85.5
2 6 86.5
3 6 87.5
5 6 87.5
7.5 6 89.5
10 6 89.5
15 6 91
20 6 91
25 6 91.7
40 6 93
50 6 93
60 6 93.6
75 6 93.6
100 6 94.1
125 6 94.1
150 6 95
200 6 95
2 2 84
3 2 84
5 2 85.5
7.5 2 87.5
10 2 88.5
15 2 89.5
20 2 90.2
DT Series ODP 25 2 91
30 2 92.4
40 2 92.4
50 2 93.6
UL_CSA_Zertifikate.pdf
http://database.ul.com/...y+Efficiency&objid=1075219759&cfgid=1073741824&version=versionless&parent_id=1073996576&sequence=1[23.10.2013 11:28:52]
ZWKG.E104590 - Electric Motors Certified for Energy Efficiency
60 2 94.1
75 2 94.1
100 2 94.1
125 2 94.1
150 2 94.5
200 2 94.5
1 4 82.5
1.5 4 84
2 4 84
3 4 86.5
5 4 87.5
7.5 4 88.5
10 4 89.5
DT Series ODP 15 4 91
20 4 91
25 4 91.7
30 4 92.4
40 4 93
50 4 93
60 4 93.6
75 4 94.1
100 4 94.1
125 4 94.5
150 4 95
200 4 95
(+) TEFC - Totally Enclosed Fan Cooled; ODP - Open Drip Proof
© 2013 UL LLC
When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL
Environment database for additional information regarding this product's certification.
The appearance of a company's name or product in this database does not in itself assure that products so identified have been
manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and
covered under UL's Follow-Up Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The
Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and
in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online
Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material
must include a copyright notice in the following format: "© 2013 UL LLC".
UL_CSA_Zertifikate.pdf
http://database.ul.com/...y+Efficiency&objid=1075219759&cfgid=1073741824&version=versionless&parent_id=1073996576&sequence=1[23.10.2013 11:28:52]
UL_CSA_Zertifikate.pdf
PMArt.-Nr 58 769WEG -Mot rUL-certE104590
WWW.UL.COM
1.877.ULHELPS / (1.877.854.3577)
File E104590
Project 97NK38080
REPORT
on
COMPONENT - MOTORS
UL_CSA_Zertifikate.pdf
File E104590 Vol. 1 Sec. 10 Page 1 Issued: 1997-12-18
and Report Revised: 2007-10-09
DESCRIPTION
PRODUCT COVERED:
RATINGS:
UL_CSA_Zertifikate.pdf
File E104590 Vol. 1 Sec. 10 Page 2 Issued: 1997-12-18
and Report Revised: 2007-10-09
UL_CSA_Zertifikate.pdf
File E104590 Vol. 1 Sec. 10 Page 2A Issued: 1997-12-18
and Report New: 2007-10-09
VII - Frequency/Voltage
UL_CSA_Zertifikate.pdf
File E104590 Vol. 1 Sec. 10 Page 3 Issued: 1997-12-18
and Report Revised: 2006-08-02
VIII - Standard
I - IEC
N - NEMA
IX - Feature 1
A – Run Capacitor
X - None
X - Feature 2
H – High Efficiency
L – AL3
N – NEMA premium efficiency
P - Premium efficiency
T - Top premium efficiency
X - No special features
XI - Output (Horsepower) Single or Dual
1 to 500 hp rating (examples 002 = 2 hp, 2.5 =
2-1/2 hp)
D07 - 1.0/1.6
D08 - 1.25/2.0
D09 - 1.6/2.0
D10 - 2.0/3.0
D11 - 2.5/4.0
D12 - 3.0/5.0
D13 - 4.0/6.3
D14 - 5.0/8.0
D15 - 6.3/10
D16 - 8/12.5
D17 - 10/16
D18 - 12.5/2.0
D19 - 16/25
D20 - 20/30
D21 - 25/40
D22 - 30/50
D23 - 40/63
D24 - 50/80
D25 - 63/100
D26 - 80/125
D27 - 100/160
D28 - 125/200
D29 - 160/250
DAM – 0.5/2.0
DBB – 15/60
DCH – 18.5/75
DDX – 6.25/25
DMC – 25/100
DNM – 1.25/5
V00 to V99 = Special horsepower
VAS – 10/40
VAT – 0.75/3.0
VBA – 3.75/15
VEV – 2.5/10
VKS – 1.75/7.5
VDN – 2.5/9kW
VDO – 3.3/13kW
VBU – 4.5/19kW
VAB – 7.5/30kW
VMJ – 6/24kW
VMK – 1.6/6kW
DPJ – 6.5/26kW
XII - Poles
02 - 2 pole
04 - 4 pole
06 - 6 pole
08 - 8 pole
BA - 4/2 pole
CA - 4/6 pole
DB – 8/4 pole
FC – 12/6 pole
UL_CSA_Zertifikate.pdf
File E104590 Vol. 1 Sec. 10 Page 4 Issued: 1997-12-18
and Report Revised: 2007-08-01
E - Special motor
O - Motor with special features
P - Standard motor
XV - End of Code
Z - Ending
1. This Report covers only the general construction features on the motors and
no evaluation of the performance characteristics has been made. Therefore,
the acceptability of these motors when operated under normal or abnormal
load conditions within an appliance or enclosure must be determined for each
use.
UL_CSA_Zertifikate.pdf
File E104590 Vol. 1 Sec. 10 Page 4A Issued: 1997-12-18
and Report New: 2003-09-29
2. The Recognition of the motors covered by this Report is based upon the
assurance of the manufacturer that the specific motor model number will
change if any significant construction variations are made. Because of this,
it is necessary that the complete motor model be included in the appliance
Report, along with the complete nameplate electrical ratings and significant
construction features that can be determined by inspection, without
disassembly of the motor.
UL_CSA_Zertifikate.pdf
File E104590 Vol. 1 Sec. 10 Page 5 Issued: 1997-12-18
and Report Revised: 2006-08-02
4. The motor mounting means, motor leads and lead terminations must be
evaluated for each end use.
UL_CSA_Zertifikate.pdf
File E104590 Vol. 1 Sec. 10 Page 6 Issued: 1997-12-18
and Report Revised: 2003-12-01
CONSTRUCTION DETAILS:
Definitions -
Marking - The marking includes the company name (or file number) and
complete electrical rating. This marking may be on a metal nameplate,
pressure sensitive label, permanent ink or die-stamping on the motor shell.
SPACINGS -
Minimum spacings, mm (in.)
Motor diameter
178 mm (7 in.) Motor diameter more than 178 mm
Potential or less a (7 in.) a
involved in Over surface and
volts Parts involved through air Over surface Through air
0-125 Commutator or collector rings 1.6 4.8b 3.2 b
(1/16) 3/16 (1/8)
126-250 Elsewhere in the motor 2.4c 6/4b,d 3.2b,d
(3/32) (1/4) (1/8)
251-660 Commutator or collector rings 1.6 4.8b 4.8b
(1/16) (3/16) (3/16)
Elsewhere in the motor 2.4 6.4b,d 6.4b,d
(3/32) (1/4) (1/4)
251-660 Commutator or collector rings and 6.4e 9.5 6.4
live parts of the brush rigging (1/4) (3/8) (1/4)
a This is the diameter, measured in the plane of the laminations, of the circle circumscribing
the stator frame, excluding lugs, fins, boxes, and the like, used solely for motor mounting,
cooling, assembly, or connection.
b Spacings of not less than 2.4 mm (3/32 in.) are acceptable throughout a universal motor.
c For a motor rated 1/3 horsepower (249 W output) or less, these spacings may not be less than
1.6 mm (1/16 in.).
d Film-coated wire is considered to be an uninsulated live part. However, a spacing of not less
than 2.4 mm (3/32 in.), over surface and through air between film-coated wire, rigidly
supported and held in place on a coil and a dead-metal part is acceptable.
e Through-air spacings involving a collector ring may be not less than 3.2 mm (1/8 in.).
f For subassemblies mounted on or inside a motor, spacings not less than 6.4 mm (1/4 in.) are
acceptable between live parts and dead metal parts within a subassembly, and between parts in
different subassemblies, or of the following types only:
UL_CSA_Zertifikate.pdf
File E104590 Vol. 1 Sec. 10 Page 7 Issued: 1997-12-18
and Report Revised: 2003-07-30
1. Complete Assembly - Painted cast iron frame or aluminum with cast iron
or aluminum end bells, size may vary. Base integral with motor frame
as shown. Motor provided with "C" and "D" flanges, with or without
mounting base.
UL_CSA_Zertifikate.pdf
File E104590 Vol. 1 Sec. 10 Page 8 Issued: 1997-12-18
and Report
UL_CSA_Zertifikate.pdf
File E104590 Vol. 1 Sec. 10 Page 9 Issued: 1997-12-18
and Report Revised: 2002-12-10
3. Complete Assembly - Painted cast iron or aluminum frame with cast iron
or aluminum end bells. Motor with "C" and "D" flanges, with or without
base.
UL_CSA_Zertifikate.pdf
File E104590 Vol. 1 Sec. 10 Page 10 Issued: 1997-12-18
and Report Revised: 2004-07-30
UL_CSA_Zertifikate.pdf
File E104590 Vol. 1 Sec. 10 Page 11 Issued: 1997-12-18
and Report
UL_CSA_Zertifikate.pdf
File E104590 Vol. 1 Sec. 10 Page 12 Issued: 1997-12-18
and Report Revised: 2002-12-10
1. End Bells - Painted cast iron or aluminum 1/8 in. thick minimum. Size
and shape may vary.
UL_CSA_Zertifikate.pdf
File E104590 Vol. 1 Sec. 10 Page 13 Issued: 1997-12-18
and Report Revised: 2003-10-09
UL_CSA_Zertifikate.pdf
PMArt.-N 58769WEG -MotrCSA-cert169832
Certificate of Compliance
Certificate: 1619832 Master Contract: 160062
Ezio Migliozi
Issued by: Ezio Migliozi
PRODUCTS
CLASS 4228 01 - MOTORS AND GENERATORS - For Hazardous Locations
CLASS 4228 81 - MOTORS AND GENERATORS - For Hazardous Locations - Certified to
US Standards
Class I, Div 2, Groups A, B, C and D; Class II, Div 2, Group F and G; Temp Code T4, T3, T3C, T2A, T2B or
T2D (Where applicable).
Induction Motors, squirrel cage, Type ET, Model 1UTEI or TE0I series and Model 1UTE? or TE0? Series,
continuous duty, three phase, enclosure TEFC; 500 hp max, 1000 V max, 50/60, 50 and 60 Hz; Class B, F and
H insulation; NEMA frames 56, 143T up to 587T and IEC 63 up to 355M/L**; S.F. 1.25 max *; 2-4-6-8 poles,
high efficiency motors (except two speed motors):
The motors covered under the scope above can be available as or with:
UL_CSA_Zertifikate.pdf
Certificate: 1619832 Master Contract: 160062
2. Multiple Voltages.
3. NEMA Premium Efficiency.
4. Inverter and/or Vector Duty, max. SF 1.0, maximum 40°C ambient, with Temperature Code as below:
4.1 T3 Temperature Code for Frames: 143/5T – 364/5T.
4.2 T2B Temperature Code for Frames: 404/5T and 586/7 (T3 Temperature Code for 220 HP max).
4.3 T2D Temperature Code for Frames: 445/7/9T – 504/5T.
5. T4 Temperature Code with max. SF 1.0, No Space Heater, no Inverter or Vector Duty, Maximum 40°C
ambient.
6. GroupG
6.1 Available with T4 Temperature Code, no space heater, no inverter, max. SF 1.0, maximum 40°C
ambient.
6.2 Available with T3C Temperature Code, no space heater, no inverter, max. SF 1.0, maximum 60°C
ambient.
7. Space Heater (except for 56 frame).
8. Optional up to 50°C ambient:
T3 Temperature Code for Frames: 143/5T - 213/5T and 324/6 – 364/5T, with Space Heaters, as Inverter
and Vector Duty.
9. Optional up to 60°C ambient:
9.1 T3 Temperature Code for Frames: 143/5 -213/5T, with Space Heaters, as Inverter and Vector Duty.
9.2 T2D Temperature Code for Frames: 254/6T - 364/5T, with Space Heaters, as Inverter and Vector
Duty.
9.3 T2A Temperature Code for Frames 404/5T and 586/7T, with Space Heaters, as Inverter and Vector
Duty (T3 Temperature Code for 220 HP max).
9.4 T2B Temperature Code for Frames: 444/5/7/9T – 504/5T, with Space Heaters, as Inverter and Vector
Duty.
9.5 T3C temperature Code, no Space Heaters, no Inverter or Vector Duty.
10. TEAO Construction (Minimum Airflow Nameplate mandatory).
11. Additional junction box available.
UL_CSA_Zertifikate.pdf
Certificate: 1619832 Master Contract: 160062
12. Aluminum frame and with removable feet (except for Model 1UTE? or TE0?).
13. * SF 1.25 up to 100HP, SF 1.15. for 125HP and above.
14. ** For detailed frames see document TB-1458.
APPLICABLE REQUIREMENTS
-CSA Standard C22.2 No. 0 - M1991- General Requirements - Canadian Electrical Code Part II.
-CAN/CSA-C22.2 No. 100-04 - Motors and Generators
-CAN/CSA-C22.2 No. 213-M1987 - Non-Incendive Electrical Equipment for Use in Class I, Div. 2 Hazardous
Locations.
-CAN/CSA C22.2 No. 145-M1986 - Motors and Generators for Use in Hazardous Locations (Guidance)
-NFPA 70 - US National Electric Code
-UL 674 4th Ed.- Electric Motors and Generators for Use in Division 1 Hazardous Locations (Guidance)
-UL 1604 3rd Ed – Electric Equipment for Use in Class I and II, Division 2 and Class III Hazardous Location
-UL 1004 – Motors and Generators
UL_CSA_Zertifikate.pdf
UL_CSA_Zertifikate.pdf
PMArt.-58601Baldore-motr il-arcolerUL-certE4615
NDMM2.E46145
Incomplete Rotating Machines and Rotating Machine Parts - Component
Page Bottom
See General Information for Incomplete Rotating Machines and Rotating Machine Parts - Component
Motor part, Specification Nos. 05, 06, 07, 17, 19, 33, 34, 35, 36, 37, 75, 76, 77 may be followed by one suffix letter A through
Z, followed by one to four-digits, Nos. 1 through 9999, may be followed by one suffix letter A through Z, followed by one to four-
digits, Nos. 1 through 9999, may be followed by a suffix letter A through Z and number 1 through 9.
Motor part, Specification Nos. 34, 35 and 36, with or without one suffix letter A through V; followed by a 1- to 4-digit, Nos. 1
through 9999, with or without one suffix letter W through Z; followed by a 1- to 4-digit, Nos. 1 through 9999 and with or without
suffix letter A through Z.
Motor part, Specification Nos. 09, 10, 39, 40, or 80-, followed by a one to four-digit number 1 through 9999, with or without one
prefix Letter A through V; followed by a one to four-digit number 1 through 999, with or without one prefix Letter W through Z; all
of which may be followed by a suffix Letter A through Z, followed by a number 1-9.
Motor, Part No. LN, followed by 1, followed by A, followed by 001, followed by W, followed by 001, and may be followed by an
additional two or three digit alphanumeric.
Marking: Company name, tradename "BALDOR" or "E46145", and frame or motor spec. designation and the Recognized Component
Mark on the product or smallest unit container in which the product is packaged.
Last Updated on 2012-06-05
© 2013 UL LLC
When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL
Environment database for additional information regarding this product's certification.
The appearance of a company's name or product in this database does not in itself assure that products so identified have been
manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and
covered under UL's Follow-Up Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The
Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and
in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online
Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material
must include a copyright notice in the following format: "© 2013 UL LLC".
UL_CSA_Zertifikate.pdf
http://database.ul.com/...+Component&objid=1081437164&cfgid=1073741824&version=versionless&parent_id=1079255438&sequence=1[23.10.2013 11:32:59]
PMArt.-N 58601Baldore-motr il-arcolerCSA-certifae026 C0
Certification Record
Three phase, squirrel cage induction motors, 600V max, 50/60Hz, as follows:
Max Max
Spec. No HP-NP HP-TP Frame Insl. Encl.
6 15 - 6200M A-F a-d
7 20 - 7500M A-F a-d
05 - 18 250 10 143T-447T A-H a-d
18 450 - 444-449T F,H a,b
33 - 42 75 10 42-364T A-H a-d
Enclosure designation: a = Open, b = Tefc, c = Tenv, d = Teao
Three phase, squirrel cage induction motors, 4160V max, 50/60Hz as follows:
UL_CSA_Zertifikate.pdf
35***S357 1 200 50/60 4 B Dp a
35***S368 1/3 200 50/60 4 B Tefc a
35***S369 1 200 50/60 4 B Tefc a
35***S464 1-1/2 230/460 60 6 F Tefc a
35***X510 3 208-230/ 60 4 B Open a
460
35***X566 1 208-230/ 60 8 B Opao a,b,c
460
35***Y482 1 208-230 60 8 B Opao a,b,c
35***Y501 1 575 60 8 B Opao a,b,c
35***Y631 1-1/4 203-230 60 6 - Open a,b
35****- 1-1/4 203-230 60 6 - Open a,b
Y631
35***Y703 1-1/4 208-230 60 6 H Teao a,b
35***Y704 1-1/4 575 60 6 H Teao a,b
35***Y705 1-1/4 460 60 6 H Teao a,b
36***239 1 575 60 8 B Tefc a
36***W141 1 460 60 8 B Tefc a
36***W781 1 200 60 8 B Tefc a
36***X201 3 575 60 4 F Tefc a,b
36****- 3 575 60 4 F Tefc a,b
X201
36***X229 3 208-230 60 4 F Tefc a
36***X238 3 460 60 4 F Tefc a
36***X686 5 380-415/ 50/60 4 B Open a
460
36***X720 5 208-230 60 4 B Open a
42***Y14 50 230/460 60 4 B Open a
Notes:
a. * is replaced by letter and numbers. These variations represent mechanical changes such as
colour, shaft dimensions, etc.
b. Accepted as a component for use in other CSA Certified equipment where the suitability of the
combination is determined by the CSA International.
c. Air over motor.
UL_CSA_Zertifikate.pdf
09, 33-39 CS-CR 15 5 42-256U a-d
33 - 35 Res. Sp. ph. 1/2 1/2 42-145 a-d
27 - 30 Rep. st. 10 - 56-256U a-d
Note: Enclosure designation, a = Open, b = Tefc, c = Tenv, d = Teao
UL_CSA_Zertifikate.pdf
2761 230
36***- 2 115/230 60 4 B Tefc a
3444
36***- 3 220 60 4 F Tefc a
X715
64***W013 1/4 110/220/ 50/60 4 F open a
115/230
Notes:
a. * is replaced by letter and numbers. These variations represent mechanical changes such as
colour, shaft dimensions, etc.
b. Accepted as a component for use in other CSA Certified equipment where the suitability of the
combination is determined by the Canadian Standard Association.
c. Air over motor.
DC motors as follows:
Notes:
1. The specification number has 3 suffix numbers coding mechanical variations followed by an
additional 4 suffix numbers to code winding and rotor details, the protector used and the
ventilation system.
2. Motors without terminal boxes are Certified as components only of other CSA Certified
equipment.
UL_CSA_Zertifikate.pdf
10-PSS-O 1/50 a,b
20-AB-O 1/25 a
20-ABP-O 1/25 a
20-BA-O 1/25 a,b
20-CB-O 1/25 a,b
20-DA-O 1/25 a,b
20-FTA-O 1/25 a,b
20-GNA-O 1/25 a,b
20-PSSH-O 1/25 a,b
20-PSS-O 1/25 a,b
30-AB-O 1/20 a
30-ABP-O 1/20 a
30-BA-O 1/20 a,b
30-CB-O 1/20 a,b
30-PSM-O 1/20 a,b
30-PSSH-O 1/20 a,b
74-AHP-O 1/4 a
74-AP-O 1/4 a
74-EB-O 1/4 a,b
74-JK-O 1/4 a,b
Notes:
a. Certified as components only of other Certified equipment where the suitability of the
combination is determined by the CSA International.
b. Gearmotor.
Notes:
1. * is replaced by letter and numbers. These variations represent mechanical changes such as
color, shaft dimensions, etc.
2. These motors are Certified as components for use only in other certified equipment where the
suitability of the combination is determined by CSA International.
UL_CSA_Zertifikate.pdf
Specification No 63: 75 KW Max. Continuous, 86 KW Max. Standby, 600 Vac, 1 Phase
50-60 Hz, 131 KVA Max. Continuous, 141 KVA Max. Standby,600 Vac, 50-60 Hz, 3
Phase. 2250 rpm max., OPFC Enclosure, Insulation Class B, F or H, 40°C Ambient
Max.
Motor Model 34****S129, TEAO, 1 ph, ½ hp, 115 V, 60 Hz, 6.2 A, 825 rpm, Class F, 40ºC
ambient maximum, thermally protected (automatic reset), frame 48Z.
Notes:
1. “*” may be replaced by “-“ or letters and numbers. These variations represent mechanical
changes such as flange type, shaft dimensions, conduit box, etc. Suffix letter (eg. G1, H4 etc.)
may follow. A letter character followed by a single numeric character indicates slight
variations that do not affect the mechanical layout drawing (i.e., paint color, lead lengths, etc.).
2. The above mentioned motors are Certified as components for use only in other Certified
equipment where the suitability of the combination is determined by CSA International.
Specification No. 34***X773**, 1.5hp, 115V, 60Hz, 14.3A, 3450rpm, 56YZ frame, SF 1.0,
Thermally Protected (Manual Reset), class F, 40 C ambient, TEFC, Duty 30 minutes. Note. 1.
*** May be replaced by “-”or letter and numbers. These variations represent mechanical
changes such as flange type, shaft dimensions, conduit box, etc. Suffix letter (eg. G1, H4 etc)
may follow. A letter character followed by a single numeric character and indicates slight
variations that do not affect the mechanical layout drawing (such as paint color, lead lengths,
etc.). 2. These motors are certified as components for use only in other certified equipment
where the suitability of the combination as determined by CSA International.
/sl
UL_CSA_Zertifikate.pdf
UL_CSA_Zertifikate.pdf
PMArt-Nr.28790 0 4 oil ev lswitch Mobrey/EmersonProces ManagementGmbH
Seite 1 von 1
PM Art-Nr. 287900004 oil level switch Mobrey / Emerson Process Management GmbH
Certification Record
• Squing 2 Vibrating Fork Point Level Switch; Input Rated 20 - 264Vac maximum, 2VA, 50/60Hz, 11
- 60Vdc maximum, 500mA max, Relay Contacts Rated 250Vac/30Vdc, 5Amps, Working Pressure
1668psi, Enclosure Type 4X, -40 to 80C ambient; Temperature Code for H version: -40 to 80C
ambient; Pollution Degree 4, Installation Category II.
• Rosemount 2120, 2130 Vibrating Fork Point Level Switch; Input Rated 20 - 264Vac
maximum, 2VA, 50/60Hz, 11- 60Vdc maximum, 500mA max, Relay Contacts Rated
250Vac/30Vdc, 5Amps, Working Pressure 1668psi, Enclosure Type 4X, -40 to 80C
ambient; Process Temperature for 2120 version: -40 to 150C; Process Temperature for
2130***M version: -40 to 180C; Process Temperature for 2130***E version: -70 to 260C;
Pollution Degree 4, Installation Category II, Single Seal.
• Two Wire Ultrasonic Level Transmitter, Models MSP4**R*-**C*, MSP4**N*-**C*,
Input Rated 12-40Vdc, 4-20mA, maximum, Relay Contacts Rated 2A, 30Vdc Resistive, 1A,
30Vdc Inductive, Working Pressure 15PSI, -40ºC to 70ºC Ambient; Pollution Degree 2,
Installation Category I. Enclosure :Metal Type 4X, IP66 or Plastic IP66, IP67.
Note: The "* "in the model number refers to suffix denoting options on the unit, refer to
nomenclature info.
• Two Wire Ultrasonic Level Transmitter, Rosemount 3101 and Rosemount 3102, Input
Rated 12-40Vdc, 4-20mA, maximum, Relay Contacts Rated 2A, 30Vdc Resistive, 1A,
30Vdc Inductive, Working Pressure 15PSI, -40ºC to 70ºC Ambient; Pollution Degree 2,
Installation Category I. Enclosure :Metal Type 4X, IP66 or Plastic IP66, IP67.
/pl
Copyright © 2013 CSA International. All rights reserved.
http://directories.csa-international.org/xml_transform.asp?xml=certxml%5C040796_0... UL_CSA_Zertifikate.pdf
07.11.2013
UL_CSA_Zertifikate.pdf
PMArt.-N 58120_0BuehlrInformation ULCSAcert
Informationen zur
UL/CSA – Zulassung
der verwendeten elektrischen Bauteile in
Niveauschaltern und / oder
Technologies GmbH
Temperaturschaltern.
Harkortstr. 29
40880 Ratingen
Elektrische Komponente UL – CSA – Bühler Typ
Registriernr. Registriernr
ECBT2 6233-01
1.1 Steckverb. 3 pol. + PE E186708 006837_0 M3
ECBT2 6233-01
1.2 Steckverb. 7 pol. + PE E102079 018753_0 C7
AVLV2 5835-01
4 Schaltlitze E242293 702000
Hinweis:
Unter folgender Internetadresse können Sie die angefügten UL – Zulassungen ebenfalls erhalten:
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/gfilenbr.html
ECBT2 6233-01
1.2 Connector 7 pol. + PE E102079 018753_0 C7
AVLV2 5835-01
4 Wiring Material E242293 702000
Clue:
Under follow internetadress, your are able to find the UL – authorization:
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/gfilenbr.html
UL_CSA_Zertifikate.pdf
PMArt.-Nr58120_1. BuehlrconectorCSA-cert068370
Certified Product Listing - 006837_0_000 | Certified Product Listing | CSA Group Seite 1 von 4
PM Art.- Nr. 581200_1.1 Buehler connector CSA-cert 006837 0 000
Quick Links
Certification Record
• "Quick-Change" plugs and connectors, Series 6 with suffixes, 32XXX, 600V, 30A max (10 AWG), 20A max (12
AWG); 15A max (14 AWG), 13A max (16 AWG) 2- to 4-poles, CSA Types 4, 4X, 6, 6P and IEC529 Type IP68
enclosure ratings.
• "Quick Change" Tee with "Mini Change" Cable Drop, Cat Nos TC40200A46MXXX,
TC30200A46MXXX, rated at 15A, 600V ac, and Cat Nos TC40200A45MXXX, and
TC30200A45MXXX, rated at 10A, 600V ac.
• "Mini-Change" male and female receptacles, Series 1 to 3 with suffixes, Series AP or DN or SD, watertight (may
couple with liquidtite conduit): Series 40XXX, 41XXX, 42XXX, 43XXX, 47XXX with Certified equipment wire leads
and male and female connectors, moulded on No 16 AWG, 18 AWG, Type TEW wiring material, Type ST or SO
flexible cord; 2-pole, 600V, 13A (16 AWG), 10A (18 AWG), Series 40700, 408XX; Series 1R2 followed by 11
suffixes; 3-pole, 600V, 10A (16 AWG), 7A (18 AWG), Series 40900, 410XX, Series 1R3 followed by 11 suffixes,
50971, 60900 (T-Connector); 4-pole, 600V, 8A (16 AWG), 7A (18 AWG), Series 41100, 412XX; Series 1R4 followed
http://www.csagroup.org/ca/en/services/testing-and-certification/certified-product-listing/c...UL_CSA_Zertifikate.pdf
08.11.2013
Certified Product Listing - 006837_0_000 | Certified Product Listing | CSA Group Seite 2 von 4
by 11 suffixes, AP-3-A-R01-WB1-M-XXX-S; 5-pole, 600V, 8A (16 AWG), 7A (18 AWG), Series 41300, 414XX;
Series 1R5 followed by 11 suffixes; moulded on No 16 AWG, Type, AWM, TEW or type SO flexible cord; 8A, 41100;
5-pole, 8A, 41300; 6-pole, 8A, 42600; 7-pole, 7A, 42800; Series 2R7 followed by 11 suffices; 8-pole, 7A, 43000;
9-pole, 7A, 47000; Series 3R9 followed by 11 suffixes;10-pole, 7A, 47200; Series 3R1 followed by 11 suffixes; 12-
pole, 7A, 47400; Series 3R2 followed by 11 suffixes.
• "Mini-Change" special-use connectors 3-pole Series 1R-40901 (male) and 1R-40902 (Female), rated 10A (14
AWG), 600V ac.
• "Mini-Change" connectors, Series 1 to 3 with 14 suffixes, Series AP or DN or SD, 41600, 417XX, Series 2R6
followed by 11 suffixes; 6-pole, 8A, 600V (16 AWG), 5A, 300V (18 AWG).
• "Mini-Change" connectors, Series 1 to 3 with suffixes, Series AP or DN or SD, 41100 and 41200, 4 pole, 3A, 300V
on No 22 AWG Types AWM, TEW leads or Certified flexible cord.
• "Mini-Change" connectors, Series 1 to 3 with suffixes, Series AP or DN or SD, 611WWXXYYZZ, (3 pole),
612WWXXYYZZ (4 pole), 613WWXXYYZZ (5 pole), rated 10A (No 16 AWG) 7A (No 18 AWG), 120V ac.
• "Mini-Change" attachable male and female connectors Series 1 to 3 with 14 suffixes, Cat Nos 1A3000, 1A3006 (3
poles), rated 13A (16/3 AWG), 600V; Cat Nos 1A4000, 1A4006, AP4A-MSE-FA and AP4A-FSI-FA, (4 poles),
rated 13A (16/4 AWG), 8A (18/4 AWG), 600V; Cat Nos 1A5000, BL-136534, BDNC-F01-AN-NAN-01, 1A5006, BL-
136535, BDNC-F01-CN-NAN-01(5 poles), rated 8A (18/5 AWG), 600V.
• "Mini-Change" male plugs Cat Nos 42669, 42684, 42695, 42697 and female connector, Cat No 42670, (6 pos),
rated 13A (2 poles), 600V.
• "Mini-Change" Tee connectors, Cat Nos APC3010, DN3010, SDS3010, 8A, 50V.
• "Mini-Change" Tee connectors, Cat No DN3020, rated 10A, 600V max.
• "Mini-Tee" connectors, Series 1 to 3 with 14 suffixes, Series AP or DN or SD, 334, 4-pole max, Series 1 to 3 with 14
suffixes, 445, 5-pole max, 8A, 600V (16 AWG).
• European "Micro-Change" connectors, plugs and receptacles, 3A, 300V max, Series 7 or 8 or 9 or B with 12
suffixes, 8XXXX on No 22 AWG; 1A, 300V max on No 26 AWG.
• "Micro-Change" connectors, male and female, Series 7 to 9 or B with suffixes, Series AP or DN or SD, rated 300V:
2-pole Series 70000 rated 8A (18 AWG), 5A (22 AWG); 3-pole, Series 70200 rated 7A (18 AWG), 5A (22 AWG);
4-pole, Series 70400 rated 5.6A (18 AWG), 4A (22 AWG); 5-pole, Series 70600, rated 4A (18, 22 AWG); 6-pole
Series 70800 rated 4A (18, 22 AWG); moulded onto Certified AWM, Series 70XXX, 1A, 300V ac max onto No 26
AWG, AWM.
• "Micro-Change" connectors, Series 7 to 9 or B with suffixes, Series AP or DN or SD, 803 with LED, rated 3A, 30V.
• Cat. No. 1200652055, Micro-change Cord Connectors, rated 4A max (2-poles, No 20 AWG), 250V.
• Cat. No. 1200652056, Micro-change Attachment Plug, rated 4A max (2-poles, No 20 AWG), 250V.
• "Micro-Change" connectors, Series 80800XP and 8R813XE, 8-pole, rated 1.5A, 300V on Nos 22-24 AWG.
• "Micro-Change" AC connectors, Series 7 to 9 or B with suffixes, Series AP or DN or SD, 7XXXX, 3A, 300V max, on
No 18 or 22 AWG; 1A, 300V max on No 26 AWG.
• "Micro-Change" DC connectors, Series 7 to 9 or B with suffixes, Series AP or DN or SD, 8XXXX, 3A, 24V max, on
No 22 AWG.
• "Micro-Change" "AC" and "DC" T-splitters, Series 7 to 9 or B with suffixes, Series AP or DN or SD, 80XXX and
81XXX on No 22/4 AWG, AWM, rated 3A, 300V; 1A, 300V max on No 26 AWG.
• "Micro-Change" DC connectors, Series AP or DN or SD, male and female, 3A, 300V dc, 3-pole, Series 7 to 9 or B
with suffixes, 80200; 4-pole, Series 7 to 9 or B with suffixes, 80400; moulded onto No 18 to 22 AWG, CSA Certified
flexible cord; 1A, 300V dc max on No 26 AWG.
• "Micro-Change" Series 12, Cat Nos 8A400, 8R4B00, 091204, 941.400103, 941.400104 (4 pos) and 8A500,
8R5B00, 091205, BL-136531, BDNC-F11-CN-NDN-01, BL-136532, BDNC-F11-AN-NDN-01, (5 pos), attachable
male and female connectors, rated 5A (18- 22 AWG), 300V.
• "Micro-Change" Y Connectors Series 7 to 9 or B with 14 suffixes, Series AP or DN or SD, 49300, 175A, 125V.
• Micro-change connectors, M12 Cable Assemblies without LEDs, rated 4A max (5-poles max, Nos 18,
22-24 AWG), 300V.
• Micro-change connectors, M12 Cable Assemblies with LEDs, rated 4A max (5-poles max, Nos 22-24
AWG), 30V. Alternate Cat Nos C04BEK00VYXXXM, C04BEN00VYXXXM, C04BEK00TYXXXM,
C04BEN00TYXXXM.
• Micro-change connectors, M12 Cable Assemblies with LEDs, rated 4A max (5-poles max, Nos 20
AWG), 30V.
• Micro-change connectors, M12 Cord Connectors without LEDs, rated 4A max (5-poles max, Nos 18,
22-24 AWG), 300V.
• Micro-change connectors, M12 Cable Assemblies and Cord Connectors without LEDs, rated 4A max
(5- poles max, Nos 18, 22-24 AWG), 300V.
• Micro-change connectors, M12 Cable Assemblies and Cord Connector Splitters without LEDs, rated
4A max (5- poles max, Nos 18, 22 AWG), 300V.
• Micro-change connectors, M12 Attachment Inlets, rated 4A max (5-poles max, Nos 18, 22 AWG),
300V.
• Micro-change connectors, M12 Appliance Inlets and Outlets, rated 4A max (5-poles max, Nos 18, 22
AWG), 300V.
• Micro-change connectors, M12 Appliance Inlets and Outlets, rated 4A max (5-poles max, Nos 18, 22
AWG), 30V.
• Micro-change connectors, M12 Appliance Inlets and Outlets, PC board mounted, rated 4A max
(5-poles max), 30V.
• Micro-change connectors, M12 Cable Assembly, Cat No. PT-4T-FSI-CB2-X-XXX-S, rated 4A max (4
poles, Nos. 22, 4AWG), 250V
http://www.csagroup.org/ca/en/services/testing-and-certification/certified-product-listing/c...UL_CSA_Zertifikate.pdf
08.11.2013
Certified Product Listing - 006837_0_000 | Certified Product Listing | CSA Group Seite 3 von 4
• Micro-change connectors, M12 In-Line Splitter, Cat No. S-4-TLS-CB2-M-XXX-S, rated 4A max (4
poles, Nos. 22, 3AWG), 250V
• "Nano-Change" connectors, Series 4 or 5, 14 suffixes, 45 with LED, rated 3A, 30V; without LED, rated 3A, 125V.
• Micro-change connectors, M12 Adaptor Ultra Lock / M12 Series 8WX030, rated 4A max (5-poles
max, Nos 18, 22 AWG), 300V. "X"= 2, 3, 4, 5 pole designation.
• "Nano-Change" Series 40, 44, 45, 50, 54, 55 rated 4A, 75V.
• Connector bodies, Series 3000, 3200, 440, incorporating 15A, 20A, 30A, 125V ac/250V ac NEMA configuration
receptacles.
• "Die Block" plugs, receptacle connectors and accessories, rated 25A, 600V ac, Cat Nos 22801 through 22807,
22901 through 22907, 43301 through 43306, and 43308; mounting shell, Cat No 50-0081; mounting/wiring box, Cat
No 65-0040.
• Multi-Port Interconnect System (MPIS), "Mini-Change" Series AP or DN or SD, 4XXMYZZ-WW; "MICRO-CHANGE",
Series B or V with 12 suffixes, Series AP or DN or SD, 7XXMYZZ-WW and 8XXMYZZ-WW, rated 2.6A max,
300/600V, where current ratings are determined by number of input poles and number of output connectors.
• Multi-Port Interconnect System (MPIS) "Nano-Change" Series BNB-D110-XXX.
• Special-use connectors, "control" connectors, Series 33200, 33500, 33800, 34100, 34400, 34700, 35000, 35300,
35600; "dual round" connectors, Series 23000, 23300, 48000, 25200, 25400; "die blocks", Series 22800, 22900,
43300; rated 600V max, 7 to 25A max, for use with Nos 16 to 12 AWG, Type SO, flexible cord, or individual
conductors.
• Moulded polyester locking type, weatherproof receptacles, 2-p, 3-w, and 3-p, 4-w, grounding type, with integral
selector switch, Cat Nos: 6700-WS, 20A; 6900-WS, 30A; 67W47-WS, 20A, 125V, L5-20R; 67W48-WS, 20A, 250V,
L6-20R; 67W49-WS, 20A, 277V, L7-20R; 67W75-WS, 20A, 250V, L15-20R, 3PH; 67W76-WS, 20A, 480V, L16-20R,
3PH; 67W81-WS, 20A, 120/208V, L21-20R, 3PH-Y; 67W82-WS, 20A, 277/480V, L22-20R, 3PH-Y; 67W83-WS,
20A, 347/600V, L23-20R, 3PH-Y; 69W47-WS, 30A, 125V, L5-30R; 69W48-WS, 30A, 250V, L6-30R; 69W49-WS,
30A, 277V, L7-30R; 69W74-WS, 30A, 125/250V, L14-30R; 69W75-WS, 30A, 250V, L15-30R, 3PH; 69W76-WS,
30A, 480V, L16-30R, 3PH; 69W77-WS, 30A, 600V, L17-30R, 3PH; 69W81-WS, 30A, 120/208V, L21-30R, 3PH-Y;
69W82-WS, 30A, 277/480V, L22-30R, 3PH-Y; 69W83-WS, 30A, 347/600V, L23-30R, 3PH-Y.
• S-use Industrial Type, Non-Locking, pin and sleeve, devices Cat Nos Y560B, Y560C, Y560P, Y560R, rated 60A,
277/480V ac.
• Two-outlet receptacles Series 6XWXXDPLX rated 20A max, 277V max.
• S-use, DIN 43650 moulded female connectors on Certified Nos 18 or 20 AWG, Types PUR or PVC cable, Series
E392, E492, rated 3A, 250V max and Series E452, E462, E472, rated 5A, 250V max.
• Attachable Cable Series D, E, F, G, H with Certified s-use female connectors Series E392, E452, E462, E472, E492
and Certified s-use "Mini-Change" or "Micro-Change" male plugs on opposite ends of Certified Nos 18 or 20 AWG,
Types PUR or PVC cable, rated 5A max, 250V max.
• Special-use receptacles, with locking screw; Types MPM 122 and MPM 182, 16A 250V ac 300V dc; Type MPM
192, 10A 24V dc.
• S-use, DIN 43650 attachable female connectors without circuits Series C03, C12, C18, C20, C40, C41, C81, rated
13A, 300V max; Series C19, C62, raed 10A, 250V max; Series C05, rated 8A, 250V max, for use with certified nos
16/3 or 16/4AWG, round flexible cord, AWM or Tew.
• S-use, DIN 43650 attachable female connectors with circuits Series S02, S11, S14, S18, S53, S54, S55, rated13A,
300V max; Series S19, S56, S62, rated 10A, 250V max; Series S05, rated 8A, 250V max, for use with Certified nos
16/3 or 16/4 AWG, round flexible cord, AWM or TEW.
• S-use, DIN 43650 plug bases Series B042, B043, B142, B143, B202, B212, B213, B222, B232, B233, B262, B263,
B283, rated 13A, 300V max; Series B292, B292020, B293, B293020, B392, B393, rated 10A, 250V max; Series
B152, B153, rated 8A, 250V max, for use with Certified Nos 16/3 or 16/4 AWG, flexible cord, AWM or TEW.
• DeviceNet Series Cordsets:
Cat Nos DN, DND, DNB, DNF, DNDF, DNE, DNDG, APC, APCD, SDS, or SDSD followed by 0, 1, 2, 3, 4, 6, 7, 8, or
9, followed by 0, 1, 2, 3, 6, 8, or 9, followed by A, SS, SS8, NB, or blank, followed by M, followed by any three digit
number 001 through 999, may be followed by Y, and Balluff Series, Cat Nos BDNR and BDNC (with suffixes
denoting construction options, rated at 3A, 300V; 4A, 250V; 8A, 300V).
• DeviceNet Series Receptacles:
Cat Nos DN, DND, DNB, DNE, DNDG, APC, APCD, SDS, SDSD, or PO followed by 5, 6, C or D, followed by 0, 1,
2, or 3, followed by 0, 1, 2, 3, 6, 8, 9, or M, followed by 0, 1, 2, 3, 4, 5, 6, 7, 8, or 9, followed by A, SS, SS8,NB, or
blank, followed by M, followed by any three digit number 001 through 999.
• Decivce Net. Mini-Change right angle connector 41131-FXXX, rated8A, 300V (power) and 1A, 12V (Signal)
• M12 Micro-Change, Female/Male Cord Connectors and Receptacles, rated 30Vac / 36Vdc, 2 A (8-Pole, No24 AWG)
• M12Micro-Change, Female/Male Cord Connectors and Receptacles, rated 30V ac/dc, 1.5 A (12-Pole, No 24 or 26 AWG)
Notes:
http://www.csagroup.org/ca/en/services/testing-and-certification/certified-product-listing/c...UL_CSA_Zertifikate.pdf
08.11.2013
Certified Product Listing - 006837_0_000 | Certified Product Listing | CSA Group Seite 4 von 4
• Pole-Mount Power Taps Cat Nos 76050-XX (where XX is the flexible cord length from 0.3m (1ft) to
15m (50ft)), rated 13A, 600V.
• Pole-Mount Power Taps Cat Nos 76050-XX (where XX is the flexible cord length above 15m (50ft) to
30m(99ft)), rated 10A, 600V.
• Pole-Mount Power Taps Cat Nos 76050-R, rated 13A, 600V.
Notes:
/jw
CSA Group Web Sites CSA Group Sites Information For... Legal About CSA Group
CSA Group Bayern GmbH CSA Communities Manufacturers Privacy CSA Group is an independent, not-for-profit member-
based association dedicated to advancing safety,
emitel CSA Registries Members Terms of Use sustainability and social good. We are an internationally-
accredited standards development and testing &
mi Technology Group OHS Portal Government / Service Agreement
certification organization. We also provide consumer
Regulators / AHJs
Orb Optronix Public Review Evidence of Insurance product evaluation and education & training services. Our
Retailers / Importers / broad range of knowledge and expertise includes:
Sira Companies Shop CSA Exporters industrial equipment, plumbing & construction, electro-
medical & healthcare, appliances & gas, alternative
energy, lighting and sustainability. The CSA mark appears
on billions of products around the world.
Copyright © 2013 CSA Group. All Rights Reserved. Contact Us Site Map Accessibility
http://www.csagroup.org/ca/en/services/testing-and-certification/certified-product-listing/c...UL_CSA_Zertifikate.pdf
08.11.2013
PMArt.-N 58120_1. BuehlrMP conectorULcertE186708
ECBT2.E186708 - Connectors for Use in Data, Signal, Control and Power Applicatio... Page 1 of 1
ECBT2.E186708
Connectors for Use in Data, Signal, Control and Power Applications - Component
Page Bottom
Connectors for Use in Data, Signal, Control and Power Applications - Component
See General Information for Connectors for Use in Data, Signal, Control and Power Applications - Component
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up
Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the
data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must
appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright ©
2009 Underwriters Laboratories Inc.®"
UL_CSA_Zertifikate.pdf
mhtml:file://C:\Dokumente und Einstellungen\zietz\Eigene Dateien\UL\UL Zertifikat... 16.06.2009
PMArt.-N 58120_1.2BuehlrHatingconectorCSA-cert0187530
Certified Product Listing - 018753_0_000 | Certified Product Listing | CSA Group Seite 1 von 3
PM Art.-Nr. 581200_1.2 Buehler Harting connector CSA-cert 018753 0 000
Quick Links
Certification Record
D-32339
Germany
• Types Staf, 50V, 10A, 40-poles max for No 18 to 14 AWG (screw or solder terminals).
• Type Han 10 EE, 600V, 16A, 10 poles for 20 to 12 AWG (crimp connections).
• Type Han 18 EE, 600V, 16A, 18 poles for 20-12 AWG (crimp connections).
• Type Han 32 EE, 600V, 16A, 32 poles for 20-12 AWG (crimp connections).
Notes:
1. The connectors are sold only to manufacturers for the assembly of Certified electrical equipment and are Certified
only for use in equipment where the acceptability of the combination is to be determined by CSA International.
2. The crimp connections are made with this submittor's hand or power operated crimping tools.
3. The receptacles are not for interrupting current.
4. The connectors may be acceptable at voltages greater than rated voltage when they are components of Certified
electrical equipment permitting small spacings or where adjacent poles are omitted or not used to provide correct
spacings.
5. Connectors for use with flat cables are rated 50V, 1A.
6. The connectors may be provided with protecting covers for cable connection, piggy back connections, accessories
etc.
7. The unassembled parts are sold only to manufacturers for the assembly of Certified electrical equipment and are
Certified only for use in equipment where the acceptability of the combination is to be determined by CSA
International.
8. Numbers may be added to the type numbers, indicating the number of poles.
Notes:
1. The connectors are sold only to manufacturers for the assembly of Certified electrical equipment and are
Certified only for use in equipment where the acceptability of the combination is to be determined by CSA
International or other NRTL.
2. The crimp connections are made with this submittor's hand or power operated crimping tools.
3. The receptacles are not for interrupting current.
http://www.csagroup.org/ca/en/services/testing-and-certification/certified-product-listing/c...UL_CSA_Zertifikate.pdf
08.11.2013
Certified Product Listing - 018753_0_000 | Certified Product Listing | CSA Group Seite 2 von 3
4. The connectors may be acceptable at voltages greater than rated voltage when they are components of Certified
electrical equipment permitting small spacings or where adjacent poles are omitted or not used to provide
correct spacings.
5. Connectors for use with flat cables are rated 50V, 1A.
6. The connectors may be provided with protecting covers for cable connection, piggy back connections,
accessories etc.
7. The unassembled parts are sold only to manufacturers for the assembly of Certified electrical equipment and are
Certified only for use in equipment where the acceptability of the combination is to be determined by CSA
International.
8. The crimp connections are made with this submittor's hand or power operated crimping tools.
9. The contact block assemblies are not for interrupting current.
10. Numbers may be added to the type numbers, indicating the number of poles.
TO THE REQUIREMENTS OF CSA C22.2 NO. 182.3 – M1987 (R2009):
• Type Han D, 600V ac, 10A, 128 poles max, for No 22 to No 14 AWG (crimp connections); 30V, 2A, 128 poles
max for No 30 to 20 AWG (wire wrap connections.
• Types Han DD, 600V 10A, 216 poles max for No 22 to 14 AWG (crimp connection).
• Types Han 8U, 50V, 10A, 8-poles for No 22 to 14 AWG (crimp connections).
• Type Han E, 600V ac, 16A, 48 poles max, for No 18 to 14 AWG (screw terminals), for No 16 AWG (solder
terminals), for No 20 to 12 AWG (crimp connections).
• Type Han E AV, 600V ac, 16A, 24 poles max, for No 18 to 10 AWG (screw terminals).
• Type Han D AV, 600V, 10A, 40 or 64 poles, for No. 18 to 10 AWG (screw terminals).
• Type Han 6 HsB, 600V ac, 35A, 6 poles, for No 18 to 10 AWG (screw terminals).
• Type Han A, 600V ac, 10A, 32 poles max, for No 18 to 14 AWG (screw terminals), for No 20-12 AWG (crimp
connections).
• Type R15, 600V ac, 10A, 7 poles, for No 22 to 14 AWG (crimp connection).
• Type Han Es, 600V ac, 16A, 48 poles max, for No 22 to 14 AWG (screwless type terminals).
• Type Han HvE, 600V ac, 16A, 32 poles max, for No 18 to 14 AWG (screw terminals), for No 16 AWG (solder
terminals), for No 20 to 12 AWG (crimp connections).
• Type Han HvEs, 600V ac, 16A, 20 poles max, for No 22 to 14 AWG (screwless type terminals).
• Type Han K 8/24, 600V 16A, for No 20 to 12 AWG (crimp connection) and 300V 10A 24-poles, for No 22 to
14 AWG (crimp connection).
• Type Han K 4/8, 600V 80A, 4-poles for No 16 to 4 AWG (screw terminals) and 600V 16A, 8-poles, for No 20-
12 AWG (screw terminals.
• Type Han Distributor, Han Vv20-1, Han Vv20-2, 600V, 16A, 20 poles max., for No. 18 to 10 AWG (screw
terminals);
• Type Han 12 HsC, 600V, 40A, 12 poles for No. 13 to 8 AWG (crimp connections) and 300V, 10A, 2 poles for
No. 25 to 13 AWG (crimp connections);
• Type Han K4/0, 600V, 80A, 4 poles for No. 5 AWG (screw terminals);
• Type Han K4/2, 600V, 80A, 4 poles for No. 5 AWG (screw terminals) and 300V, 16A, 2 poles for No. 13
AWG (screw terminals);
• Type Han K6/12, 600V, 40A, 6 poles for No. 13 to 7 AWG (screw terminals) and 300V, 10A, 12 poles for No.
20 to 13 AWG (screw terminals;
• Type Han K6/36, 600V, 40A, 6 poles for No. 13 to 9 AWG (crimp connections) and 300V, 10A, 36 poles for
No. 25 to 13 AWG (crimp connections);
• Type Han 4A, 300V, 10A, 4 poles for No. 14 AWG (screw terminals).
• Type Han K6/6, 600V, 100A, 6 poles for No. 5 to 2 AWG (screw terminals) and 600V, 15A, 6 poles for No. 24
to 12 AWG (screw terminals);
• Type Han DD module, 600V, 12A, 12 poles for No. 26 to 14 AWG (crimp connections);
• Type Han E module, 600V, 16A, 6 poles for No. 20 to 12 AWG (crimp connections);
• Type Han C module, 600V, 32A, 3 poles for No. 16 to 10 AWG (crimp connections);
• Type Han Q5/0, 600V, 16A, 5 poles for No. 20 to 14 AWG (crimp connections);
• Type Han 46 EE, 600V, 16A, 46 poles max for No. 20 to 12 AWG (crimp connections);
• Type Han 24 ES AV, 600V, 12A, 24 poles max for No. 26 to 14 AWG (screwless type terminals).
• Type Han Q4/2, (power contact) 600V 35A, poles max for 16 to 10 AWG (crimp connections).
• Type Han Q4/2, (signal contact) 250V 10A, 2 poles max for 26 to 14 AWG (crimp connections).
• Type Han Q7/0, 600V 10A, 7 poles max for 26 to 14 AWG (crimp connections).
• Accessories: Han Multikontalet module and Han Pneumatik modules.
Notes:
1. Certified as a component for use only where the suitability of the final combination is determined by CSA Group or
another NRTL.
http://www.csagroup.org/ca/en/services/testing-and-certification/certified-product-listing/c...UL_CSA_Zertifikate.pdf
08.11.2013
Certified Product Listing - 018753_0_000 | Certified Product Listing | CSA Group Seite 3 von 3
2. The crimp connections are to be made with this submitter’s hand or power operated crimping-tools.
4. Numbers may be added to the type numbers, indicating the number of poles.
/lb
CSA Group Web Sites CSA Group Sites Information For... Legal About CSA Group
CSA Group Bayern GmbH CSA Communities Manufacturers Privacy CSA Group is an independent, not-for-profit member-
based association dedicated to advancing safety,
emitel CSA Registries Members Terms of Use sustainability and social good. We are an internationally-
accredited standards development and testing &
mi Technology Group OHS Portal Government / Service Agreement
certification organization. We also provide consumer
Regulators / AHJs
Orb Optronix Public Review Evidence of Insurance product evaluation and education & training services. Our
Retailers / Importers / broad range of knowledge and expertise includes:
Sira Companies Shop CSA Exporters industrial equipment, plumbing & construction, electro-
medical & healthcare, appliances & gas, alternative
energy, lighting and sustainability. The CSA mark appears
on billions of products around the world.
Copyright © 2013 CSA Group. All Rights Reserved. Contact Us Site Map Accessibility
http://www.csagroup.org/ca/en/services/testing-and-certification/certified-product-listing/c...UL_CSA_Zertifikate.pdf
08.11.2013
PMArt.-N 58120_1.2BuehlrHatingconectorC-UL ScertE10279
ECBT8.E102079 - Connectors for Use in Data, Signal, Control and Power Applicati... Seite 1 von 2
ECBT8.E102079
Connectors for Use in Data, Signal, Control and Power Applications Certified for
Canada - Component
Page Bottom
Connectors for Use in Data, Signal, Control and Power Applications Certified for
Canada - Component
See General Information for Connectors for Use in Data, Signal, Control and Power Applications Certified for Canada - Component
Component Accessory, Optional Strain Relief for IDC connectors, Model(s) Series Har-Flex Cat. No. 1529, followed by three digits,
followed by 0503000.
Component Connector, Model(s) Series 09 45 : Connectors: 09 45 115 1520, 09 45 115 1522, 09 45 100 1520, 09 45 125 1520, 09 45 400
1520, 09 45 145 1520, 09 45 145 1520XL, 09 45 195 1520, 09 45 151 1525, 09 45 151 1520, 09 45 151 1520XL, 09 45 500 1520, 09 35 227
0421, 09 35 227 0401, 09 45 115 1720, 09 45 100 1720, 09 45 125 1720
Series 10G: Connectors: 09 45 151 1560, 09 45 151 1120, 09 45 151 1561, 09 45 151 1121, 09 35 225 0401, 09 35 225 0402, 09 35 225 0403,
09 35 226 0401, 09 35 226 0402, 09 35 226 0403, 09 35 225 0421, 09 35 226 0421, 09 15 300 0431, 09 45 145 1560, 09 45 195 1560, 09 45
145 1560 023, 09 45 125 1560, 09 45 115 1560, 09 35 226 0401 031, 0935 226 0402 031 and 09 45 100 1560.
Series D-SUB SMT, Cat. No. 0955, followed by 1, 2, 3 or 4, followed by 15, 29, 55 or 69, followed by 3, 6 or 7, followed by 6 or 8, followed by
11, 12, 21 or 22, followed by 741
Series Har-Flex Cat. No. 15, followed by 11, 12, 15, 21, 22, 25 or 29, followed by three digits, followed by 2, 5 or 6, followed by 5 or 6, followed
by two digits, may be followed by three digits.
Series HARAX M12-L, Cat. Nos. 21032711505, 21032712505, 21032721505 and 21032722505
Component Connector Accessories (housings), Model(s) 09 45 545 0027, 09 45 545 0028, 09 45 545 0029, 09 45 545 0033, 09 45 545
0030, 09 45 545 0031 and 09 45 545 0032
Component Connector Plastic Hoods - Series har-mik, Model(s) 60130140146110, 60130140146351, 60130260146110, 60130260146351,
60130360146110, 60130360146351
Component Panel feed through, Model(s) 09 45 545 1560, 09 45 245 1560, 09 45 245 1590, 09 35 225 0311, 09 35 225 0312, 09 35 225
0331, 09 45 200 1560, 09 45 215 1560, 09 45 215 1561, 09 45 215 1562 and 09 45 225 1560
Connectors, Model(s) 0918506* thru 0918564*, 16 04 170 5104 000, 16 04 170 5106 000, 16 11 170 5202 000, 16 11 170 5205 000, 16 11
170 5206 000, 16 11 170 5207 000, 16 21 170 1301 000, 16 22 170 1301 000, 16310xx1201000 [%], 16320xx1101000 [%], D-SUB Combo
8W8 (Part No. 09694009009765), Har-bus HM Power, Series Han 3A, Series Har-bus HM, Series Har-link
Series DIN powers, "Type F/FC ,Type 2F/FC, Type FM, Type H and Type MH", Model(s) 0906*
VarPol headers and connectors, "Series Socket strips", Model(s) 16330961201000, 16340961101000
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?nam... UL_CSA_Zertifikate.pdf
07.11.2013
ECBT8.E102079 - Connectors for Use in Data, Signal, Control and Power Applicati... Seite 2 von 2
Marking: Company name or trademark , , model designation and the Recognized Component Mark for Canada, on the
device or carton.
Last Updated on 2013-10-04
© 2013 UL LLC
When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment
database for additional information regarding this product's certification.
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up
Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-
misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with
permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the
following format: "© 2013 UL LLC".
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?nam... UL_CSA_Zertifikate.pdf
07.11.2013
PMArt.-N 58120_2BuehlrOKIRedswitchUL-certE7063
NRNT2.E70063
Switches, Industrial Control - Component
Page Bottom
Magnetically operated reed switches Model(s) ORD-324*, ORD-324H*, ORD211*, ORD221*, ORD2210*, ORD2211*, ORD2212*, ORD2221*,
ORD225*, ORD228VL*, ORD229*, ORD234*, ORD234M*, ORD325*, ORD728*, ORD9215*, ORD9215M*, ORD9216*, ORD9217*, ORT233*,
ORT551*
Reed switches intended for use in office appliances, business and EDP equipment Model(s) ORD213, ORD214, ORD218, ORD219,
ORD2210V, ORD2217, ORD2217V, ORD2218, ORD311, ORD312
Marking: Company name or tradename "OKI" and catalog designation on the product or on the smallest unit container in which the product is
packaged.
Last Updated on 2012-12-26
© 2013 UL LLC
When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment
database for additional information regarding this product's certification.
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up
Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-
misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with
permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the
following format: "© 2013 UL LLC".
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?nam... UL_CSA_Zertifikate.pdf
07.11.2013
PMArt.-Nr.58120 _3BuehlerLimtorthermalprotectorC-UL-UScertE16 01
YFZW8.E166011 - Thermal Motor Protectors and Protectors for Hermetic and Semi... Seite 1 von 1
YFZW8.E166011
Thermal Motor Protectors and Protectors for Hermetic and Semi-hermetic
Compressors Certified for Canada - Component
Page Bottom
See General Information for Thermal Motor Protectors and Protectors for Hermetic and Semi-hermetic Compressors Certified for Canada -
Component
Protectors, Type P followed by 0, 5 or 8, followed by 1, 2, 3, 4, 5, 9 or blank, followed by 40C thru 150C, followed by "production code number".
Type Q followed by 0, 5, 8, followed by 1, 2, 3, 4, 5, 9 or blank, followed by letter A to Z, followed by 40C thru 150C, followed by "production
code number"; Type Y followed by 0, 5 or 8, followed by 1, 2, 3, 4, 5, 9 or blank, followed by letter A to Z, followed by 40C through 150C,
followed by three alpha-numeric characters, followed by "production code number".
Marking: Company name, catalog number and the Recognized Component Mark for Canada .
Last Updated on 2008-11-14
© 2013 UL LLC
When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment
database for additional information regarding this product's certification.
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up
Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-
misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with
permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the
following format: "© 2013 UL LLC".
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?nam... UL_CSA_Zertifikate.pdf
07.11.2013
PMArt.-N 58120_3Buehlrtemalprotec rCSA-cert067150
Certified Product Listing - 067165_0_000 | Certified Product Listing | CSA Group Seite 1 von 2
PM Art.-Nr. 581200_3 Buehler thermal protector CSA-cert 067165 0 000
Quick Links
Certification Record
Appliance Controls
• Thermostat, Type 03, with Suffixes AON or BON (may be followed by suffix "S" to denote shorter case), Type 54N,
125/250V ac, 15/8A (non-ind), 125V ac, 13.5A (ind), max temperature 150C, 100,000 operations.
• Thermostat, Type 03EN, may be followed by four digits, rated 125/250V ac, 15/8A (non-ind), 125V ac, 13.5A
(ind), max temperature 150C, 100,000 operations, cond temp 10 percent; 125/250Vac, 6/3A (non-ind), 250,000
operations, max cal temp 100 ºC, cond temp 10 percent. Type 03EP, rated 250V ac, 0.1A (resistive), 30V dc, 0.1A,
(100,000 operations), max cal temp 150C.
• Manual-reset thermostat, Types 05, 05N, 05EN, 24, 24N, with suffixes 0001 to 9999, 125/250V ac, 15/10A (N.I.),
max temperature 150C, (6,000 operations).
• Thermostat, Types 09N, 10N, 11N, 11EN, 50N, 50EN, with or without 3 or 4 digit suffix, rated 125/250V ac, 15/10A
(non-ind), (100,000 operations), max temperature 150C, and 200C for Types 09N and 10N. Cond. temperature for
Types 09N and 10N, 220C, for Type 11N and 50N, 165C.
• Thermostat, Type 22N, may be followed by three or four digits, rated 125/250V ac, 15/10A (ind. or non-ind.),
(100,000 operations), 125V ac, 10A (ind or non-ind), (200,000 operations) max cal temp 200C, cond temp 220C.
Type MH3, 120/250V ac, 3/2A, (non-inductive, 100,000 operations).
• Thermostat, Type 52N, rated 125/250V, 60Hz, 15/10A (resistive or inductive), 100,000 operations, max cal temp
200C (refer Note 3).
• Thermostat Types 50S, 50ES, 11S and 11ES rated 125/250V, 60Hz, 6/3A max calibration temp 150C, 100,000
operations.
• Thermostat, manual reset, Type 05EP, rated 250V ac, 0.1A (resistive), 30V dc, 0.1A, max calibration temperature
150°C, 6000 operations (1000 with load and 5000 without load).
Notes:
1. Subject controls are Certified as component of other Certified equipment where the suitability of the combination is
to be evaluated by CSA International.
2. Series 03's suffix numbers are added to denote material and types of cap, types of terminals, and types of brackets.
3. Types "52N" and "54N" are preceeded by A or B, and 3 digits (indicating temp) and followed by other suffixes.
/af
CSA Group Web Sites CSA Group Sites Information For... Legal About CSA Group
CSA Group Bayern GmbH CSA Communities Manufacturers Privacy
http://www.csagroup.org/ca/en/services/testing-and-certification/certified-product-listing/c...UL_CSA_Zertifikate.pdf
08.11.2013
Certified Product Listing - 067165_0_000 | Certified Product Listing | CSA Group Seite 2 von 2
Copyright © 2013 CSA Group. All Rights Reserved. Contact Us Site Map Accessibility
http://www.csagroup.org/ca/en/services/testing-and-certification/certified-product-listing/c...UL_CSA_Zertifikate.pdf
08.11.2013
PMArt.-N 58120_4BuehlrKWVwirngmaterilC-UL ScertE24 93
AVLV8.E242293 - Appliance Wiring Material Certified for Canada - Component Seite 1 von 1
PM Art.-Nr. 581200_4 Buehler KWV wiring material C-UL-US cert E242293
AVLV8.E242293
Appliance Wiring Material Certified for Canada - Component
Page Bottom
See General Information for Appliance Wiring Material Certified for Canada - Component
Marking: Company name and the Recognized Component Mark for Canada, on the attached tag, the reel or the smallest unit
container in which the product is packaged.
Last Updated on 2013-10-30
© 2013 UL LLC
When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment
database for additional information regarding this product's certification.
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up
Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-
misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with
permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the
following format: "© 2013 UL LLC".
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?nam... UL_CSA_Zertifikate.pdf
07.11.2013
PMArt.-N 58120_4BuehlrLap wirngmaterilCSA-cert702
Certified Product Listing - 702000 | Certified Product Listing | CSA Group Seite 1 von 1
PM Art.-Nr. 581200_4 Buehler Lapp wiring material CSA-cert 702000
Quick Links
Certification Record
70565
Germany
• Max temperature rating 105C: TEW (where exposed to oil 60C), single conductor.
Note: Per Notice 388C, Type TEW not covered for single or multi-conductor construction with shielding and overall
covering to Std C22.2 No 127-1981.
CSA Group Web Sites CSA Group Sites Information For... Legal About CSA Group
CSA Group Bayern GmbH CSA Communities Manufacturers Privacy CSA Group is an independent, not-for-profit member-
based association dedicated to advancing safety,
emitel CSA Registries Members Terms of Use sustainability and social good. We are an internationally-
accredited standards development and testing &
mi Technology Group OHS Portal Government / Service Agreement
certification organization. We also provide consumer
Regulators / AHJs
Orb Optronix Public Review Evidence of Insurance product evaluation and education & training services. Our
Retailers / Importers / broad range of knowledge and expertise includes:
Sira Companies Shop CSA Exporters industrial equipment, plumbing & construction, electro-
medical & healthcare, appliances & gas, alternative
energy, lighting and sustainability. The CSA mark appears
on billions of products around the world.
Copyright © 2013 CSA Group. All Rights Reserved. Contact Us Site Map Accessibility
http://www.csagroup.org/ca/en/services/testing-and-certification/certified-product-listing/c...UL_CSA_Zertifikate.pdf
08.11.2013
UL_CSA_Zertifikate.pdf
PMArt.-N 56149AtosPrpctrlva eNG10UL ScertE19254
VAPT7.E192514 - Solenoids for Use in Hazardous Locations Certified for Canada Seite 1 von 1
VAPT7.E192514
Solenoids for Use in Hazardous Locations Certified for Canada
Page Bottom
See General Information for Solenoids for Use in Hazardous Locations Certified for Canada
Cat. Nos. OA, OAX, OAKX, OAXS, OAKXS, OAXW, OAKXW, followed by -12AC, -12 DC, -24AC, -24DC, -110, -110DC, -125DC, -220 or -220DC,
with or without/O, with or without /WP, with or without/BT.
Cat. Nos. OZA, OZAX, OZAXS, OZAXW, followed by -A or -A/24, with or without /O, with or without /WP, with or without/BT.
Cat. Nos. OZA-T, OZAX-T, OZAXS-T, OZAXW-t with or without /WP, with or without /BT.
© 2013 UL LLC
When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment
database for additional information regarding this product's certification.
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up
Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-
misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with
permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the
following format: "© 2013 UL LLC".
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?nam... UL_CSA_Zertifikate.pdf
06.11.2013
PMArt.-N 56149AtosPropctrlva eNG10ULcertE19254
VAPT.E192514
Solenoids for Use in Hazardous Locations
Page Bottom
Models OA, OAX, OAKX, OAXS, OAKXS, OAXW, OAKXW followed by -12AC, -12DC, -24AC, -24DC, -110, -110DC, -125DC, -220 or
-220DC, with or without /O, with or without /WP, with or without /BT.
Models OZA, OZAX, OZAXS, OZAXW followed by -A or -A/24, with or without /O, with or without /WP , with or without /BT.
Models OZA-T, OZAX-T, OZAXS-T, OZAXW-T with or without /WP, with or without /BT.
© 2013 UL LLC
When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL
Environment database for additional information regarding this product's certification.
The appearance of a company's name or product in this database does not in itself assure that products so identified have been
manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and
covered under UL's Follow-Up Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The
Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and
in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online
Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material
must include a copyright notice in the following format: "© 2013 UL LLC".
UL_CSA_Zertifikate.pdf
http://database.ul.com/...s+Locations&objid=1074426668&cfgid=1073741824&version=versionless&parent_id=1073994458&sequence=1[23.10.2013 12:18:04]
PMArt.-Nr.58 358CMPcable-glandA2FCSA-cert12 1841
Certificate of Compliance
Certificate: 1211841 (LR 113642-1) Master Contract: 184585
The products listed below are eligible to bear the CSA Mark shown
David Wood
Issued by: David Wood
PRODUCTS
CLASS 4418 05 - CABLE - Hardware - For Hazardous Locations
Note: Trade Sizes M16-M90 (M16 to M130 for A2, A2F, A2FRC, A2F-FC, SS2K only) and equivalent NPT
threads.
UL_CSA_Zertifikate.pdf
Certificate: 1211841 (LR 113642-1) Master Contract: 184585
Notes:
Note:
1. Additional marking denoting trade size, and manufacturer information will be included.
2. The P2K and A2F and A2FRC, A2F-FC, SS2K cable glands are designed for appropriate Steel Tape
Armour (STA), Steel Wire Armour (SWA), and appropriate braided cable. These cables must be with extruded
sealing (solid polymeric) completely surrounding the ‘core’ (insulation and conductor), allowing for no holes or
ventilation through the inner jacket or along the cores.
The Protex 2000 cable gland is designed for appropriate Steel Tape Armour (STA), Steel Wire Armour (SWA),
and appropriate braided cable. These cables may or may not have extruded sealing (solid polymeric) completely
surrounding the ‘core’ (insulation and conductor).
3. According to CEC C22.1-98, Section 18-106 Part 3, Tapered Threads shall have 5 fully engaged threads,
and where non-tapered threads are used in Groups IIC there must be 8 fully engaged threads.
4. IEC Canadian Standards may have either tapered or non-tapered threads which comply to ISO
Standards.
5. These cable glands are designed for appropriate cable, and installed to the manufacturers instructions, to
maintain integrity of the installation.
6. The A2F-FC cable entries are only suitable for flexible installations. Cables must be effectively clamped
to prevent pulling or twisting.
APPLICABLE REQUIREMENTS
CSA Standard C22.2 No 0. M1991 - General Requirements - Canadian Electrical Code Part II.
CSA Standard C22.2 No. 0.4-04 - Bonding of electrical equipment
CSA Standard C22.2 No. 94-M91 - Special Purpose Enclosures
CSA Standard C22.2 No. 174-M1984 - Cables and Cable Glands for Use in Hazardous Locations.
CAN/CSA-E60079-0:07 - Electrical apparatus for explosive gas atmospheres. PART 0: General
requirements.
CAN/CSA-E60079-1:07 - Electrical apparatus for explosive gas atmospheres. PART 1: Flameproof
enclosures “d”.
CAN/CSA-E60079-7:01 - Electrical apparatus for explosive gas atmospheres. PART 7: Increased Safety “e”.
UL_CSA_Zertifikate.pdf
PMArt.-N 56148AtosvaleNG6C-UL ScertE192514
VAPT7.E192514 - Solenoids for Use in Hazardous Locations Certified for Canada Seite 1 von 1
PM Art.-Nr. 561448 Atos valve NG6 C-UL-US cert E192514
VAPT7.E192514
Solenoids for Use in Hazardous Locations Certified for Canada
Page Bottom
See General Information for Solenoids for Use in Hazardous Locations Certified for Canada
Cat. Nos. OA, OAX, OAKX, OAXS, OAKXS, OAXW, OAKXW, followed by -12AC, -12 DC, -24AC, -24DC, -110, -110DC, -125DC, -220 or -220DC,
with or without/O, with or without /WP, with or without/BT.
Cat. Nos. OZA, OZAX, OZAXS, OZAXW, followed by -A or -A/24, with or without /O, with or without /WP, with or without/BT.
Cat. Nos. OZA-T, OZAX-T, OZAXS-T, OZAXW-t with or without /WP, with or without /BT.
© 2013 UL LLC
When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment
database for additional information regarding this product's certification.
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up
Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-
misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with
permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the
following format: "© 2013 UL LLC".
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?nam... UL_CSA_Zertifikate.pdf
06.11.2013
PMArt.-Nr 5614 8AtosvaleNG6ULcertE192514
VAPT.E192514
Solenoids for Use in Hazardous Locations
Page Bottom
Models OA, OAX, OAKX, OAXS, OAKXS, OAXW, OAKXW followed by -12AC, -12DC, -24AC, -24DC, -110, -110DC, -125DC, -220 or
-220DC, with or without /O, with or without /WP, with or without /BT.
Models OZA, OZAX, OZAXS, OZAXW followed by -A or -A/24, with or without /O, with or without /WP , with or without /BT.
Models OZA-T, OZAX-T, OZAXS-T, OZAXW-T with or without /WP, with or without /BT.
© 2013 UL LLC
When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL
Environment database for additional information regarding this product's certification.
The appearance of a company's name or product in this database does not in itself assure that products so identified have been
manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and
covered under UL's Follow-Up Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The
Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and
in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online
Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material
must include a copyright notice in the following format: "© 2013 UL LLC".
UL_CSA_Zertifikate.pdf
http://database.ul.com/...s+Locations&objid=1074426668&cfgid=1073741824&version=versionless&parent_id=1073994458&sequence=1[23.10.2013 12:18:04]
PMArt.-N 58048AtosvaleNG6C-UL ScertE192514
VAPT7.E192514 - Solenoids for Use in Hazardous Locations Certified for Canada Seite 1 von 1
VAPT7.E192514
Solenoids for Use in Hazardous Locations Certified for Canada
Page Bottom
See General Information for Solenoids for Use in Hazardous Locations Certified for Canada
Cat. Nos. OA, OAX, OAKX, OAXS, OAKXS, OAXW, OAKXW, followed by -12AC, -12 DC, -24AC, -24DC, -110, -110DC, -125DC, -220 or -220DC,
with or without/O, with or without /WP, with or without/BT.
Cat. Nos. OZA, OZAX, OZAXS, OZAXW, followed by -A or -A/24, with or without /O, with or without /WP, with or without/BT.
Cat. Nos. OZA-T, OZAX-T, OZAXS-T, OZAXW-t with or without /WP, with or without /BT.
© 2013 UL LLC
When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment
database for additional information regarding this product's certification.
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up
Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-
misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with
permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the
following format: "© 2013 UL LLC".
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?nam... UL_CSA_Zertifikate.pdf
06.11.2013
PMArt.-Nr 58 048AtosvaleNG6ULcertE192514
VAPT.E192514
Solenoids for Use in Hazardous Locations
Page Bottom
Models OA, OAX, OAKX, OAXS, OAKXS, OAXW, OAKXW followed by -12AC, -12DC, -24AC, -24DC, -110, -110DC, -125DC, -220 or
-220DC, with or without /O, with or without /WP, with or without /BT.
Models OZA, OZAX, OZAXS, OZAXW followed by -A or -A/24, with or without /O, with or without /WP , with or without /BT.
Models OZA-T, OZAX-T, OZAXS-T, OZAXW-T with or without /WP, with or without /BT.
© 2013 UL LLC
When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL
Environment database for additional information regarding this product's certification.
The appearance of a company's name or product in this database does not in itself assure that products so identified have been
manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and
covered under UL's Follow-Up Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The
Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and
in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online
Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material
must include a copyright notice in the following format: "© 2013 UL LLC".
UL_CSA_Zertifikate.pdf
http://database.ul.com/...s+Locations&objid=1074426668&cfgid=1073741824&version=versionless&parent_id=1073994458&sequence=1[23.10.2013 12:18:04]
PMArt.-N 2568401StahlTerminalboxpum8146CSAcert130971
PM Art.-Nr. 256824001 Stahl Terminal box pump 8146 CSA cert 1309971
Certificate of Compliance
Certificate: 75-GGE7 Master Contract: 7E7-,-
The products listed below are eligible to bear the CSA Mark shown
Issued by:
PRODUCTS
CLASS 3218 01
!"#
$% $&
,-E1B-7B-,BB @:7
UL_CSA_Zertifikate.pdf
Certificate: 75-GGE7 Master Contract: 7E7-,-
APPLICABLE REQUIREMENTS
= 2
$!
$B0 $2
2 $?@>$! 2
$$ >4!
$2&
=$>$!
2)--EG$ & $& (BB1B$ & $& (
$+
=1
8H
1)--EG-77$ 44 $ 2
$'4
@ !
4=$ 1I$ $>$! 1
8H
1)--EGE7B$ 44 $ 2
$'4
@ !
4=$ 1$ & 231
8H)7B07-B$ 44 $ 2
$ =4$
2
!+ +& 1
,-E1B-7B-,BB @:B
UL_CSA_Zertifikate.pdf
PMArt.-N 2568401StahlTerminalboxpum8146ULcertE17642V1S
BGYM.E177642
Boxes, Junction and Pull for Use in Zone Classified Hazardous Locations
Page Bottom
Boxes, Junction and Pull for Use in Zone Classified Hazardous Locations
See General Information for Boxes, Junction and Pull for Use in Zone Classified Hazardous Locations
© 2012 UL LLC
When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment
database for additional information regarding this product's certification.
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up
Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of
the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent
to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2012 UL LLC".
UL_CSA_Zertifikate.pdf
BGYM7.E177642
Boxes, Junction and Pull for Use in Zone Classified Hazardous Locations Certified
for Canada
Page Bottom
Boxes, Junction and Pull for Use in Zone Classified Hazardous Locations Certified
for Canada
See General Information for Boxes, Junction and Pull for Use in Zone Classified Hazardous Locations Certified for Canada
© 2012 UL LLC
When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment database
for additional information regarding this product's certification.
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up
Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the
data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the
extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2012 UL LLC".
UL_CSA_Zertifikate.pdf
QBCR.E177642
Outlet Boxes for Use in Hazardous Locations
Page Bottom
See General Information for Outlet Boxes for Use in Hazardous Locations
© 2012 UL LLC
When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment database
for additional information regarding this product's certification.
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up
Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the
data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the
extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2012 UL LLC".
UL_CSA_Zertifikate.pdf
QBCR7.E177642
Outlet Boxes for Use in Hazardous Locations Certified for Canada
Page Bottom
See General Information for Outlet Boxes for Use in Hazardous Locations Certified for Canada
© 2012 UL LLC
When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment database
for additional information regarding this product's certification.
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up
Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the
data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the
extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2012 UL LLC".
UL_CSA_Zertifikate.pdf
PMArt.-N 5861 Lap KabelÖfex-1503x1,5CSA-cert18570
Certificate of Compliance
Certificate: 1185170 (LL 53776-6) Master Contract: 154019
The products listed below are eligible to bear the CSA Mark shown
PRODUCTS
CLASS 5851 01 - WIRES - Appliance
UL_CSA_Zertifikate.pdf
Certificate: 1185170 (LL 53776-6) Master Contract: 154019
APPLICABLE REQUIREMENTS
UL_CSA_Zertifikate.pdf
PMArt.-N 5861 Lap KabelÖfex-1503x1,5UL-certE63 4
8/$SSUREDWLRQ
IU86$
)LUPD
8,/$33*PE+6WXWWJDUW
UL_CSA_Zertifikate.pdf
UL_CSA_Zertifikate.pdf
PMArt.-N 251 602StahlTerminalboxpum8146ULcertE17642V1S
BGYM.E177642
Boxes, Junction and Pull for Use in Zone Classified Hazardous Locations
Page Bottom
Boxes, Junction and Pull for Use in Zone Classified Hazardous Locations
See General Information for Boxes, Junction and Pull for Use in Zone Classified Hazardous Locations
© 2012 UL LLC
When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment
database for additional information regarding this product's certification.
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up
Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of
the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent
to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2012 UL LLC".
UL_CSA_Zertifikate.pdf
BGYM7.E177642
Boxes, Junction and Pull for Use in Zone Classified Hazardous Locations Certified
for Canada
Page Bottom
Boxes, Junction and Pull for Use in Zone Classified Hazardous Locations Certified
for Canada
See General Information for Boxes, Junction and Pull for Use in Zone Classified Hazardous Locations Certified for Canada
© 2012 UL LLC
When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment database
for additional information regarding this product's certification.
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up
Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the
data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the
extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2012 UL LLC".
UL_CSA_Zertifikate.pdf
QBCR.E177642
Outlet Boxes for Use in Hazardous Locations
Page Bottom
See General Information for Outlet Boxes for Use in Hazardous Locations
© 2012 UL LLC
When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment database
for additional information regarding this product's certification.
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up
Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the
data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the
extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2012 UL LLC".
UL_CSA_Zertifikate.pdf
QBCR7.E177642
Outlet Boxes for Use in Hazardous Locations Certified for Canada
Page Bottom
See General Information for Outlet Boxes for Use in Hazardous Locations Certified for Canada
© 2012 UL LLC
When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment database
for additional information regarding this product's certification.
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up
Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the
data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the
extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2012 UL LLC".
UL_CSA_Zertifikate.pdf
PMArt.-N 251 602 StahlTerminalboxpum 8146CSAcert130971
PM Art.-Nr. 251116002 Stahl Terminal box pump 8146 CSA cert 1309971
Certificate of Compliance
Certificate: 75-GGE7 Master Contract: 7E7-,-
The products listed below are eligible to bear the CSA Mark shown
Issued by:
PRODUCTS
CLASS 3218 01
!"#
$% $&
,-E1B-7B-,BB @:7
UL_CSA_Zertifikate.pdf
Certificate: 75-GGE7 Master Contract: 7E7-,-
APPLICABLE REQUIREMENTS
= 2
$!
$B0 $2
2 $?@>$! 2
$$ >4!
$2&
=$>$!
2)--EG$ & $& (BB1B$ & $& (
$+
=1
8H
1)--EG-77$ 44 $ 2
$'4
@ !
4=$ 1I$ $>$! 1
8H
1)--EGE7B$ 44 $ 2
$'4
@ !
4=$ 1$ & 231
8H)7B07-B$ 44 $ 2
$ =4$
2
!+ +& 1
,-E1B-7B-,BB @:B
UL_CSA_Zertifikate.pdf
PM Art.- Nr. 50468 Lap Oilfex-150 UL-cert E63634
8/$SSUREDWLRQ
IU86$
)LUPD
8,/$33*PE+6WXWWJDUW
UL_CSA_Zertifikate.pdf
PMArt.-N 50468 Lap Oilfex-150CSA-cert18570
Certificate of Compliance
Certificate: 1185170 (LL 53776-6) Master Contract: 154019
The products listed below are eligible to bear the CSA Mark shown
PRODUCTS
CLASS 5851 01 - WIRES - Appliance
UL_CSA_Zertifikate.pdf
PMArt.-Nr.504687Lap KabelUnitronicLiYCYUL-certE63 4
8/$SSUREDWLRQ
IU86$
)LUPD
8,/$33*PE+6WXWWJDUW
UL_CSA_Zertifikate.pdf
Certificate: 1185170 (LL 53776-6) Master Contract: 154019
APPLICABLE REQUIREMENTS
UL_CSA_Zertifikate.pdf
PMArt.-Nr504687Lap KabelUnitro cLiYC SA-cert185170
Certificate of Compliance
Certificate: 1185170 (LL 53776-6) Master Contract: 154019
The products listed below are eligible to bear the CSA Mark shown
PRODUCTS
CLASS 5851 01 - WIRES - Appliance
UL_CSA_Zertifikate.pdf
Certificate: 1185170 (LL 53776-6) Master Contract: 154019
APPLICABLE REQUIREMENTS
UL_CSA_Zertifikate.pdf
PMArt.-N 491365PMAconduitPCLT-23BUL-certE80294
YDRQ8.E80294 - Tubing, Mechanical Protection Certified for Canada - Component Seite 1 von 1
PM Art.-Nr. 491365 PMA conduit PCLT-23B UL-cert E80294
YDRQ8.E80294
Tubing, Mechanical Protection Certified for Canada - Component
Page Bottom
See General Information for Tubing, Mechanical Protection Certified for Canada - Component
Fittings, Type PMAFIX PRO designated "KNH" (Nickel Plated Brass and Plastic Threads), "KAH" (Nickel Plated Brass and Plastic Threads),
"KBH" (Nickel Plated Brass and Plastic Threads), "KIHG" (Plastic Threads), "KIS" (Nickel Plated Brass Threads), "KNZ PFLITSCH", and "KNZ
Jacob".
Type PMAFIX PRO designated "KNH" (Nickel Plated Brass and Plastic Threads), "KAH" (Nickel Plated Brass and Plastic Threads), "KBH" (Nickel
Plated Brass and Plastic Threads), "KIHG" (Plastic Threads), "KIS" (Nickel Plated Brass Threads), "KNZ PFLITSCH", and "KNZ Jacob".
Marking: Company name or tradenames "PMAFLEX", "EASIFLEX", "SMART-LINE", "PMA FLEXPLus", "EASIFIX", "ECOFIX", "ECONOMY", "PMAFIX",
"PMAGRIP& PMA FIXPLus", "PMAJACK", "PMAFLEX Pro", "PMAFIX PRO", product designation, temperature rating and the Recognized Component
© 2013 UL LLC
When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment
database for additional information regarding this product's certification.
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up
Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-
misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with
permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the
following format: "© 2013 UL LLC".
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?nam... UL_CSA_Zertifikate.pdf
06.11.2013
UL_CSA_Zertifikate.pdf
PMArt.-N 491365PMAconduitPCLT-23BCSA-cert178452
Certificate of Compliance
Certificate: 1784452 (LL88703-1) Master Contract: 181020
The products listed below are eligible to bear the CSA Mark shown
with adjacent indicators 'C' and 'US' for Canada and US or with
adjacent indicator 'US' for US only or without either indicator for
Canada only.
PRODUCTS
CLASS 1853 81 - TUBING - Flexible, Nonmetallic - Certified to US Standards
CLASS 1853 01 - TUBING - Flexible, Nonmetallic
!
"
#$% &&$' (
&')&*
&+,-.
UL_CSA_Zertifikate.pdf
Certificate: 1784452 (LL88703-1) Master Contract: 181020
/
!
''.' . ''7.#$9 &:;:
(*
UL_CSA_Zertifikate.pdf
PMArt.-N 491364PMAconduitPCLT-17BUL-certE80294
YDRQ8.E80294 - Tubing, Mechanical Protection Certified for Canada - Component Seite 1 von 1
YDRQ8.E80294
Tubing, Mechanical Protection Certified for Canada - Component
Page Bottom
See General Information for Tubing, Mechanical Protection Certified for Canada - Component
Fittings, Type PMAFIX PRO designated "KNH" (Nickel Plated Brass and Plastic Threads), "KAH" (Nickel Plated Brass and Plastic Threads),
"KBH" (Nickel Plated Brass and Plastic Threads), "KIHG" (Plastic Threads), "KIS" (Nickel Plated Brass Threads), "KNZ PFLITSCH", and "KNZ
Jacob".
Type PMAFIX PRO designated "KNH" (Nickel Plated Brass and Plastic Threads), "KAH" (Nickel Plated Brass and Plastic Threads), "KBH" (Nickel
Plated Brass and Plastic Threads), "KIHG" (Plastic Threads), "KIS" (Nickel Plated Brass Threads), "KNZ PFLITSCH", and "KNZ Jacob".
Marking: Company name or tradenames "PMAFLEX", "EASIFLEX", "SMART-LINE", "PMA FLEXPLus", "EASIFIX", "ECOFIX", "ECONOMY", "PMAFIX",
"PMAGRIP& PMA FIXPLus", "PMAJACK", "PMAFLEX Pro", "PMAFIX PRO", product designation, temperature rating and the Recognized Component
© 2013 UL LLC
When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment
database for additional information regarding this product's certification.
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up
Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-
misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with
permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the
following format: "© 2013 UL LLC".
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?nam... UL_CSA_Zertifikate.pdf
06.11.2013
UL_CSA_Zertifikate.pdf
PMArt.-N 491364PMAconduitPCLT-17BCSA-certifcae178452
Certificate of Compliance
Certificate: 1784452 (LL88703-1) Master Contract: 181020
The products listed below are eligible to bear the CSA Mark shown
with adjacent indicators 'C' and 'US' for Canada and US or with
adjacent indicator 'US' for US only or without either indicator for
Canada only.
PRODUCTS
CLASS 1853 81 - TUBING - Flexible, Nonmetallic - Certified to US Standards
CLASS 1853 01 - TUBING - Flexible, Nonmetallic
!
"
#$% &&$' (
&')&*
&+,-.
UL_CSA_Zertifikate.pdf
Certificate: 1784452 (LL88703-1) Master Contract: 181020
/
!
''.' . ''7.#$9 &:;:
(*
UL_CSA_Zertifikate.pdf
PMArt.-N 4301/43016cable-gandtype816 StahlCSA-certLR9480-26
UL_CSA_Zertifikate.pdf
UL_CSA_Zertifikate.pdf
UL_CSA_Zertifikate.pdf
UL_CSA_Zertifikate.pdf
PMArt-N.50726SiemnsLOG logicmdul6ED1052-MD0C-UL ScertE217
NRAQ7.E217227
Programmable Controllers Certified for Canada
Page Bottom
LOGO! Series programmable controllers, open type Model(s) 6ED1 052-1BB00-....#, 6ED1 052-1CA00-....#, 6ED1 052-1CC00-....#, 6ED1
052-1CC01-....#, 6ED1 052-1FA00-....#, 6ED1 052-1FB00-....#, 6ED1 052-1FB00-...7, 6ED1 052-1HA00-....#, 6ED1 052-1HB00-....#, 6ED1
052-1MD00-....#, 6ED1 052-2CC00-....#, 6ED1 052-2CC01-....#, 6ED1 052-2FB00-....#, 6ED1 052-2HB00-....#, 6ED1 052-2MD00-....#, 6ED1
053-1BB00-...., 6ED1 053-1CA00-...., 6ED1 053-1CG00-...., 6ED1 053-1FA00-...., 6ED1 053-1FB00-...., 6ED1 053-1FG00-...., 6ED1 053-1FH00-
...., 6ED1 053-1HA00-...., 6ED1 053-1HB00-...., 6ED1 053-1HG00-...., 6ED1 053-1HH00-...., 6ED1 055-1CB00-....@, 6ED1 055-1FB00-....@,
6ED1 055-1FB10-....@, 6ED1 055-1HB00-....@, 6ED1 055-1MA00-....@, 6ED1 055-1MB00-....@, 6ED1 055-1MD00-....@, 6ED1 055-1MM00-
....@, 6ED1 055-1NB10-....@, 6ED1 055-4MH00-....@, 6ED1-1MD00-...7
Numerical panel control systems Model(s) FiYANG 828D PPU240.2, FiYANG 828D PPU241.2, SINUMERIK 828D PPU240.2, SINUMERIK 828D
PPU240.3, SINUMERIK 828D PPU241.2, SINUMERIK 828D PPU241.3, SINUMERIK 828D PPU260.1, SINUMERIK 828D PPU260.2, SINUMERIK 828D
PPU260.3, SINUMERIK 828D PPU261.1, SINUMERIK 828D PPU261.2, SINUMERIK 828D PPU261.3, SINUMERIK 828D PPU280.1, SINUMERIK 828D
PPU280.2, SINUMERIK 828D PPU280.3, SINUMERIK 828D PPU281.1, SINUMERIK 828D PPU281.2, SINUMERIK 828D PPU281.3
Programmable controllers Model(s) SIJECT CI16, SIJECT CI16DP, SIJECT CI16DPINT, SIJECT CI16INT
Programmable controllers, open type Model(s) SIJECT CI16i, SIJECT CI16iP Step B
SINUMERIK 802D sl operator panel control systems Model(s) 802D MCP, 802D sl C/U Pro, 802D sl MCP, 802D sl version G/N plus, 802D sl
version G/N pro, 802D sl version T/M plus, 802D sl version T/M pro, 802D sl version T/M value, MCPA
SINUMERIK 840D and 810D Series display units and accessories, operator panels, " " Model(s) 6FX2*
SINUMERIK 840D and 810D Series display units and accessories, operator panels Model(s) 6FC5*
# - May be followed by 3, 4, 5 or 6.
@ - May be followed by 0, or 1.
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?nam... UL_CSA_Zertifikate.pdf
06.11.2013
NRAQ7.E217227 - Programmable Controllers Certified for Canada Seite 2 von 2
© 2013 UL LLC
When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment
database for additional information regarding this product's certification.
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up
Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-
misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with
permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the
following format: "© 2013 UL LLC".
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?nam... UL_CSA_Zertifikate.pdf
06.11.2013
PMArt-N.52138SiemnsLOG displaymodul6ED105-4MH0C-UL ScertE217
NRAQ7.E217227
Programmable Controllers Certified for Canada
Page Bottom
LOGO! Series programmable controllers, open type Model(s) 6ED1 052-1BB00-....#, 6ED1 052-1CA00-....#, 6ED1 052-1CC00-....#, 6ED1
052-1CC01-....#, 6ED1 052-1FA00-....#, 6ED1 052-1FB00-....#, 6ED1 052-1FB00-...7, 6ED1 052-1HA00-....#, 6ED1 052-1HB00-....#, 6ED1
052-1MD00-....#, 6ED1 052-2CC00-....#, 6ED1 052-2CC01-....#, 6ED1 052-2FB00-....#, 6ED1 052-2HB00-....#, 6ED1 052-2MD00-....#, 6ED1
053-1BB00-...., 6ED1 053-1CA00-...., 6ED1 053-1CG00-...., 6ED1 053-1FA00-...., 6ED1 053-1FB00-...., 6ED1 053-1FG00-...., 6ED1 053-1FH00-
...., 6ED1 053-1HA00-...., 6ED1 053-1HB00-...., 6ED1 053-1HG00-...., 6ED1 053-1HH00-...., 6ED1 055-1CB00-....@, 6ED1 055-1FB00-....@,
6ED1 055-1FB10-....@, 6ED1 055-1HB00-....@, 6ED1 055-1MA00-....@, 6ED1 055-1MB00-....@, 6ED1 055-1MD00-....@, 6ED1 055-1MM00-
....@, 6ED1 055-1NB10-....@, 6ED1 055-4MH00-....@, 6ED1-1MD00-...7
Numerical panel control systems Model(s) FiYANG 828D PPU240.2, FiYANG 828D PPU241.2, SINUMERIK 828D PPU240.2, SINUMERIK 828D
PPU240.3, SINUMERIK 828D PPU241.2, SINUMERIK 828D PPU241.3, SINUMERIK 828D PPU260.1, SINUMERIK 828D PPU260.2, SINUMERIK 828D
PPU260.3, SINUMERIK 828D PPU261.1, SINUMERIK 828D PPU261.2, SINUMERIK 828D PPU261.3, SINUMERIK 828D PPU280.1, SINUMERIK 828D
PPU280.2, SINUMERIK 828D PPU280.3, SINUMERIK 828D PPU281.1, SINUMERIK 828D PPU281.2, SINUMERIK 828D PPU281.3
Programmable controllers Model(s) SIJECT CI16, SIJECT CI16DP, SIJECT CI16DPINT, SIJECT CI16INT
Programmable controllers, open type Model(s) SIJECT CI16i, SIJECT CI16iP Step B
SINUMERIK 802D sl operator panel control systems Model(s) 802D MCP, 802D sl C/U Pro, 802D sl MCP, 802D sl version G/N plus, 802D sl
version G/N pro, 802D sl version T/M plus, 802D sl version T/M pro, 802D sl version T/M value, MCPA
SINUMERIK 840D and 810D Series display units and accessories, operator panels, " " Model(s) 6FX2*
SINUMERIK 840D and 810D Series display units and accessories, operator panels Model(s) 6FC5*
# - May be followed by 3, 4, 5 or 6.
@ - May be followed by 0, or 1.
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?nam... UL_CSA_Zertifikate.pdf
06.11.2013
NRAQ7.E217227 - Programmable Controllers Certified for Canada Seite 2 von 2
© 2013 UL LLC
When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment
database for additional information regarding this product's certification.
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up
Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-
misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with
permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the
following format: "© 2013 UL LLC".
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?nam... UL_CSA_Zertifikate.pdf
06.11.2013
PMArt.-N5072 SiemnsLOG extnsiomdul6ED105-CB10 -UL ScertE217
NRAQ7.E217227
Programmable Controllers Certified for Canada
Page Bottom
LOGO! Series programmable controllers, open type Model(s) 6ED1 052-1BB00-....#, 6ED1 052-1CA00-....#, 6ED1 052-1CC00-....#, 6ED1
052-1CC01-....#, 6ED1 052-1FA00-....#, 6ED1 052-1FB00-....#, 6ED1 052-1FB00-...7, 6ED1 052-1HA00-....#, 6ED1 052-1HB00-....#, 6ED1
052-1MD00-....#, 6ED1 052-2CC00-....#, 6ED1 052-2CC01-....#, 6ED1 052-2FB00-....#, 6ED1 052-2HB00-....#, 6ED1 052-2MD00-....#, 6ED1
053-1BB00-...., 6ED1 053-1CA00-...., 6ED1 053-1CG00-...., 6ED1 053-1FA00-...., 6ED1 053-1FB00-...., 6ED1 053-1FG00-...., 6ED1 053-1FH00-
...., 6ED1 053-1HA00-...., 6ED1 053-1HB00-...., 6ED1 053-1HG00-...., 6ED1 053-1HH00-...., 6ED1 055-1CB00-....@, 6ED1 055-1FB00-....@,
6ED1 055-1FB10-....@, 6ED1 055-1HB00-....@, 6ED1 055-1MA00-....@, 6ED1 055-1MB00-....@, 6ED1 055-1MD00-....@, 6ED1 055-1MM00-
....@, 6ED1 055-1NB10-....@, 6ED1 055-4MH00-....@, 6ED1-1MD00-...7
Numerical panel control systems Model(s) FiYANG 828D PPU240.2, FiYANG 828D PPU241.2, SINUMERIK 828D PPU240.2, SINUMERIK 828D
PPU240.3, SINUMERIK 828D PPU241.2, SINUMERIK 828D PPU241.3, SINUMERIK 828D PPU260.1, SINUMERIK 828D PPU260.2, SINUMERIK 828D
PPU260.3, SINUMERIK 828D PPU261.1, SINUMERIK 828D PPU261.2, SINUMERIK 828D PPU261.3, SINUMERIK 828D PPU280.1, SINUMERIK 828D
PPU280.2, SINUMERIK 828D PPU280.3, SINUMERIK 828D PPU281.1, SINUMERIK 828D PPU281.2, SINUMERIK 828D PPU281.3
Programmable controllers Model(s) SIJECT CI16, SIJECT CI16DP, SIJECT CI16DPINT, SIJECT CI16INT
Programmable controllers, open type Model(s) SIJECT CI16i, SIJECT CI16iP Step B
SINUMERIK 802D sl operator panel control systems Model(s) 802D MCP, 802D sl C/U Pro, 802D sl MCP, 802D sl version G/N plus, 802D sl
version G/N pro, 802D sl version T/M plus, 802D sl version T/M pro, 802D sl version T/M value, MCPA
SINUMERIK 840D and 810D Series display units and accessories, operator panels, " " Model(s) 6FX2*
SINUMERIK 840D and 810D Series display units and accessories, operator panels Model(s) 6FC5*
# - May be followed by 3, 4, 5 or 6.
@ - May be followed by 0, or 1.
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?nam... UL_CSA_Zertifikate.pdf
06.11.2013
NRAQ7.E217227 - Programmable Controllers Certified for Canada Seite 2 von 2
© 2013 UL LLC
When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment
database for additional information regarding this product's certification.
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up
Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-
misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with
permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the
following format: "© 2013 UL LLC".
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?nam... UL_CSA_Zertifikate.pdf
06.11.2013
PMArt.-N 503248HartinghousingHAN16BCSA-cert0187530
UL_CSA_Zertifikate.pdf
UL_CSA_Zertifikate.pdf
UL_CSA_Zertifikate.pdf
PMArt.-N 503248HartinghousingHAN16BC-UL S-certE235076
ECBT8.E235076 - Connectors for Use in Data, Signal, Control and Power Applicati... Seite 1 von 2
PM Art.-Nr. 503248 Harting housing HAN16B C-UL-US-cert E235076
ECBT8.E235076
Connectors for Use in Data, Signal, Control and Power Applications Certified for
Canada - Component
Page Bottom
Connectors for Use in Data, Signal, Control and Power Applications Certified for
Canada - Component
See General Information for Connectors for Use in Data, Signal, Control and Power Applications Certified for Canada - Component
Accessories (housings), Model(s) 09 35 002 0431, 09 35 002 0433, 09 45 345 0000, 09 45 345 0001, 09 45 545 0027, 09 45 545 0029, 09
45 545 0030, 09 45 545 0031, 09 45 545 0033, 09 45 595 0030, 09 45 595 0031
Component Connector, Series Han PushPull Power 4/0 Variante 14: Connectors, Model(s) 09 35 231 0311, 09 35 231 0312, 09 35 231
0331, 09 35 231 0333, 09 35 232 0311, 09 35 232 0312, 09 35 232 0331, 09 35 232 0333, 09 35 234 0311, 09 35 234 0312, 09 35 234 0331,
09 35 234 0401, 09 35 234 0421, 09 35 431 0501
Component Connector, Series Han PushPull Power 4/0 Variante 4, Model(s) 09 46 145 3410, 09 46 145 3411, 09 46 145 4400, 09 46 145
4401, 09 46 195 4400, 09 46 245 3410, 09 46 245 3430, 09 46 245 4000, 09 46 245 4001, 09 46 245 4030, 09 46 245 4031, 09 46 245 4400,
09 46 245 4430, 09 46 295 4030, 09 46 295 4031, 09 46 295 4430, 09 46 500 3401, 09 46 500 4400, 09 46 500 4401, 09 46 500 4402
Connector accessories, Model(s) Han PushPull Power 4/0 Metal Housing Plug Series
Han PushPull Power 4/0 PG 13.5 Plug Series, Han PushPull Power 4/0 PG 9 Plug Series
Connector Enclosure, "HAN ECO", Model(s) HAN ECO 10B, HAN ECO 16B, HAN ECO 24B, HAN ECO 6B
Connectors, "EMC Series", Model(s) HAN 10A, HAN 10B, HAN 16A, HAN 16B, HAN 24B, HAN 3A, HAN 6B
Connectors, "EMC/B Series", Model(s) HAN EMC-10B, HAN EMC-16B, HAN EMC-24B, HAN EMC-6B
Connectors, "HAN M(black) Series", Model(s) HAN M 10B, HAN M 16B, HAN M 24B, HAN M 3A, HAN M 48M, HAN M 6B
Connectors, "M12 Female Series", Model(s) 21033712402, 21033712413, 21033712415, 21033814410, 21033814411, 21033814412,
21033814413, 21033814430, 21033814431, 21033814432, 21033814433
Connectors, Model(s) Han 100A Crimp Module, Han 12 HsC* Series, HAN 3A+ Series, Han 40 EEE, Han 4A QL* Series, Han 4A* Series, Han 6
HsB* Series, Han 64 EEE, Han Axialscrew Module 100A, Han Axialscrew Module 40A, Han D* Series, Han DD PCB* Adaptor Series, Han DD*
Series, Han Dummy Module, Han ESS* Series, Han K 12/2* Series, Han K 3/0* Series, Han K 3/2* Series, Han K 4/4* Series, Han K 4/8* Series,
Han K 6/36* Series, Han K 8/0* Series, Han Pneumatic-Module, Han PushPull Power 4/0 C* Series, Han PushPull Power 4/0 PCB* Series, Han
PushPull Power 4/0 QL* Series, Han Q 12/0 PCB adapter, Han Q 12/0* Series, Han Q 17/0* Series, Han Q 2/0 Crimp, Han Q 2/0 Crimp HV, Han
Q 2/0 HV Series, Han Q 2/0 Series, Han Q 4/2 and Han Q 8/0 QuickLock, Han Q 4/2 PCB adapter Series, Han Q 4/2* Series, Han Q 5/0 QL*
Series, Han Q 5/0* Series, Han Q 7/0* Series, Han Q 8 PCB adapter Series, Han Q 8/0* Series, Han Quintax Module 9A, Han-Brid* Series, R15*
Series
Connectors, Grey single lever Series, Model(s) HAN 10A, HAN 10B, HAN 16A, HAN 16B, HAN 24B, HAN 3A, HAN 48B, HAN 6B
Connectors, High Pressure(HPR) Series, Model(s) HAN 10B, HAN 16B, HAN 24B, HAN 3A, HAN 6B
Connectors, Standard grey double lever Series, Model(s) HAN 10B, HAN 16B, HAN 24B, HAN 32A, HAN 32B
Panel Feed, Model(s) 09352220311, 09352220331, 09352230311, 09352230331, 09352240311, 09352240331, 09352260311, 09352260331
Marking: Company name or trademark , , model designation and the Recognized Component Mark for Canada, on the
device or carton.
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?nam... UL_CSA_Zertifikate.pdf
07.11.2013
ECBT8.E235076 - Connectors for Use in Data, Signal, Control and Power Applicati... Seite 2 von 2
© 2013 UL LLC
When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment
database for additional information regarding this product's certification.
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up
Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-
misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with
permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the
following format: "© 2013 UL LLC".
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?nam... UL_CSA_Zertifikate.pdf
07.11.2013
UL_CSA_Zertifikate.pdf
PMArt.-N 492 7HartinghousingHAN16BCSA-cert0187530
UL_CSA_Zertifikate.pdf
UL_CSA_Zertifikate.pdf
UL_CSA_Zertifikate.pdf
UL_CSA_Zertifikate.pdf
PMArt.-N 492 7HartinghousingHAN16BC-UL S-certiE235076
ECBT8.E235076 - Connectors for Use in Data, Signal, Control and Power Applicati... Seite 1 von 2
PM Art.-Nr. 492247 Harting housing HAN16B C-UL-US-certi E235076
ECBT8.E235076
Connectors for Use in Data, Signal, Control and Power Applications Certified for
Canada - Component
Page Bottom
Connectors for Use in Data, Signal, Control and Power Applications Certified for
Canada - Component
See General Information for Connectors for Use in Data, Signal, Control and Power Applications Certified for Canada - Component
Accessories (housings), Model(s) 09 35 002 0431, 09 35 002 0433, 09 45 345 0000, 09 45 345 0001, 09 45 545 0027, 09 45 545 0029, 09
45 545 0030, 09 45 545 0031, 09 45 545 0033, 09 45 595 0030, 09 45 595 0031
Component Connector, Series Han PushPull Power 4/0 Variante 14: Connectors, Model(s) 09 35 231 0311, 09 35 231 0312, 09 35 231
0331, 09 35 231 0333, 09 35 232 0311, 09 35 232 0312, 09 35 232 0331, 09 35 232 0333, 09 35 234 0311, 09 35 234 0312, 09 35 234 0331,
09 35 234 0401, 09 35 234 0421, 09 35 431 0501
Component Connector, Series Han PushPull Power 4/0 Variante 4, Model(s) 09 46 145 3410, 09 46 145 3411, 09 46 145 4400, 09 46 145
4401, 09 46 195 4400, 09 46 245 3410, 09 46 245 3430, 09 46 245 4000, 09 46 245 4001, 09 46 245 4030, 09 46 245 4031, 09 46 245 4400,
09 46 245 4430, 09 46 295 4030, 09 46 295 4031, 09 46 295 4430, 09 46 500 3401, 09 46 500 4400, 09 46 500 4401, 09 46 500 4402
Connector accessories, Model(s) Han PushPull Power 4/0 Metal Housing Plug Series
Han PushPull Power 4/0 PG 13.5 Plug Series, Han PushPull Power 4/0 PG 9 Plug Series
Connector Enclosure, "HAN ECO", Model(s) HAN ECO 10B, HAN ECO 16B, HAN ECO 24B, HAN ECO 6B
Connectors, "EMC Series", Model(s) HAN 10A, HAN 10B, HAN 16A, HAN 16B, HAN 24B, HAN 3A, HAN 6B
Connectors, "EMC/B Series", Model(s) HAN EMC-10B, HAN EMC-16B, HAN EMC-24B, HAN EMC-6B
Connectors, "HAN M(black) Series", Model(s) HAN M 10B, HAN M 16B, HAN M 24B, HAN M 3A, HAN M 48M, HAN M 6B
Connectors, "M12 Female Series", Model(s) 21033712402, 21033712413, 21033712415, 21033814410, 21033814411, 21033814412,
21033814413, 21033814430, 21033814431, 21033814432, 21033814433
Connectors, Model(s) Han 100A Crimp Module, Han 12 HsC* Series, HAN 3A+ Series, Han 40 EEE, Han 4A QL* Series, Han 4A* Series, Han 6
HsB* Series, Han 64 EEE, Han Axialscrew Module 100A, Han Axialscrew Module 40A, Han D* Series, Han DD PCB* Adaptor Series, Han DD*
Series, Han Dummy Module, Han ESS* Series, Han K 12/2* Series, Han K 3/0* Series, Han K 3/2* Series, Han K 4/4* Series, Han K 4/8* Series,
Han K 6/36* Series, Han K 8/0* Series, Han Pneumatic-Module, Han PushPull Power 4/0 C* Series, Han PushPull Power 4/0 PCB* Series, Han
PushPull Power 4/0 QL* Series, Han Q 12/0 PCB adapter, Han Q 12/0* Series, Han Q 17/0* Series, Han Q 2/0 Crimp, Han Q 2/0 Crimp HV, Han
Q 2/0 HV Series, Han Q 2/0 Series, Han Q 4/2 and Han Q 8/0 QuickLock, Han Q 4/2 PCB adapter Series, Han Q 4/2* Series, Han Q 5/0 QL*
Series, Han Q 5/0* Series, Han Q 7/0* Series, Han Q 8 PCB adapter Series, Han Q 8/0* Series, Han Quintax Module 9A, Han-Brid* Series, R15*
Series
Connectors, Grey single lever Series, Model(s) HAN 10A, HAN 10B, HAN 16A, HAN 16B, HAN 24B, HAN 3A, HAN 48B, HAN 6B
Connectors, High Pressure(HPR) Series, Model(s) HAN 10B, HAN 16B, HAN 24B, HAN 3A, HAN 6B
Connectors, Standard grey double lever Series, Model(s) HAN 10B, HAN 16B, HAN 24B, HAN 32A, HAN 32B
Panel Feed, Model(s) 09352220311, 09352220331, 09352230311, 09352230331, 09352240311, 09352240331, 09352260311, 09352260331
Marking: Company name or trademark , , model designation and the Recognized Component Mark for Canada, on the
device or carton.
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?nam... UL_CSA_Zertifikate.pdf
07.11.2013
ECBT8.E235076 - Connectors for Use in Data, Signal, Control and Power Applicati... Seite 2 von 2
© 2013 UL LLC
When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment
database for additional information regarding this product's certification.
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up
Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-
misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with
permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the
following format: "© 2013 UL LLC".
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?nam... UL_CSA_Zertifikate.pdf
07.11.2013
PMArt.-N 5861 Lap KabelÖfex-1503x1,5CSA-cert18570
Certificate of Compliance
Certificate: 1185170 (LL 53776-6) Master Contract: 154019
The products listed below are eligible to bear the CSA Mark shown
PRODUCTS
CLASS 5851 01 - WIRES - Appliance
UL_CSA_Zertifikate.pdf
Certificate: 1185170 (LL 53776-6) Master Contract: 154019
APPLICABLE REQUIREMENTS
UL_CSA_Zertifikate.pdf
PMArt.-N 50685SiemnsSignumtype3SBC-UL ScertE4653
NKCR7.E44653
Auxiliary Devices Certified for Canada
Page Bottom
SIEMENS AG E44653
I IA CE CP R&D-VI 4
WERNER-VON-SIEMENS-STRASSE 48
92220 AMBERG, GERMANY
Accessories Model(s) 3RP1901, 3RP1902, 3RP1903, 3SB19*, 3SB29*, 3SB39*, 3SX, followed by numbers., 3SY, followed by numbers.
Accessories, connection cables Model(s) 3RA27, followed by any numbers and or characters, ends with E02, E03 or E11.
Accessory devices, cable connector, plug, separate actuator, actuator head Model(s) 3SE5000, may be followed by letters and/or
numbers or 3SY.. or 3SX.
AS-I moduls for compact starters, open type Model(s) 3RA6970-3A, 3RA6970-3B, 3RA6970-3C, 3RA6970-3D, 3RA6970-3E, 3RA6970-3F
AS-Interface adaptors Model(s) 3SF1.*, 3SF2.*, 3SF3.*, 3SF5.*, 3SF54*, 3SF55*, 3SF59*, 3SF7*
AS-Interface Fail-Safe Monitors Model(s) 3RK1105, followed by -1A or -1B, followed by E or G, followed by 04, followed by -0CA0, -1CA0,
-2CA0, -3CA0 or -4CA0.
AS-interfaces Model(s) 3RG9, followed by 0, followed by 0, 1, 2, 3 or 4, followed by 0, 1, 4, 5 or 8, followed by 0, followed by AA, AB, AC, AD,
AE, AF, AG, AH, AJ, AK, SB or SC, followed by 00.
3RK1 or 3RK2, followed by 1, 2 or 4, followed by 0, followed by 0, 1, 2, 5, 7 or 8, followed by -0, -1, -2, -3 or -8, followed by A thru N or S,
followed by A thru U.*
3RV59 or 3RV69, followed by 0, 1 or 2, followed by 2, followed by -1, -2 or -4 followed by A, B, C or D, followed by B0, B4, F0, G6, M1, N0, N6,
P0, Q0, S0, U0, V0 or V1.*
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?nam... UL_CSA_Zertifikate.pdf
07.11.2013
NKCR7.E44653 - Auxiliary Devices Certified for Canada Seite 2 von 6
3TX44, followed by 01, 02, 04, 11, 12, 13, 20, 22, 31, 40, followed by 0, 1 or 2, followed by A, B or G.
Auxiliary contact blocks, open type Model(s) 3RA6911-1A, 3RA6911-2A, 3RA6912-1A, 3RA6912-2A, 3RA6913-1A, 3RA6913-2A
Auxiliary devices proximity switches , "BERO" Model(s) 3RG4, followed by 0 or 1, followed by 1, 2, 3 or 4, followed by 1, 2, 3 or 4, followed
by 0, 2, 3 or 6, followed by A or K, followed by A, B or D, followed by 00.
Auxiliary devices, position switch and as-interface accessories, cable connectors, plugs, plugs in shafts Model(s) 3SE5000*
Auxiliary devices, speed, level, fault current, voltage monitoring relays Model(s) 3UG4, followed by 5, 6 or 8, followed by 01, 11, 12, 13,
14, 15, 16, 17, 18, 21, 22, 24, 25, 31, 32, 33, 41 or 51, followed by -1 or -2, followed by A thru L, followed by A, N, L, P, Q, R, S or W, followed
by a letter and a number.*
Auxillary Device: Accessories Model(s) Types 3ZY12 and 3ZY13 followed by suffix letters and or numbers.
Auxillary Device: Open type Relay Modules Model(s) Type 3SK1 followed by 1 or 2, followed by 1, 2 or 3, followed by 0, 1, 2 or 3, followed 0,
1 or 2 followed by A, B or C followed by B0, J2, L2, B4, B3, W2, or W3 followed by 0, 1, 2, or 4, may be followed by suffix letters and/or
numbers.
Communication modules, open type Model(s) 3RA27, followed by 1, followed by 1 or 2 followed by -0, -1 or -2, followed by A, B, C or D,
followed by A, B or E, followed by 00 or 10.
Communications-capable electronic overload relays, basic units Model(s) 3UF50, followed by 01, 11, 21, 31, 41 or 51, followed by -3A or
-3B, followed by B, J or N, followed by 0 or 1.
Communications-capable electronic overload relays, expansion modules Model(s) 3UF5100-0AB, 3UF5100-0AJ, 3UF5100-0AN
Connecting supports Model(s) 3RU5136 followed by combination of 0, 1 or 4 and a letter A thru K, followed by B or D, followed by 0 or 1, with
connecting supports 3RU5936-3AA01.
3RU5146, followed by combination of 4 and a letter D thru M followed by B or D, followed by 0 or 1, with connecting supports 3RU5946-3AA01.
Connection supports, for Types 3UA58, 3UR58 or 3UW17 Model(s) 3UX1421, 3UX1421-0XA
Contact blocks, lamp holders and transformers Model(s) 3SB34, followed by 00, 02, 03, 11, 20 or 23, followed by 0A, 0B, 0C, 0D, 0E, 0F,
0G, 0H, 0J, 0K, 0L, 0M, 0N, 0P, 0Q, 1A, 1B, 1C, 1D, 1F, 1G, 1H, 1L, 1M, 1N, 1PA, 1PB, 1PC, 1PD, 1PE, 1QA, 1QB, 1QC, 1QD, 1QE, 1RA, 1RB,
1RC, 1RD, 1RE, 2A, 2D, 2F, 2G, 2H, 3A, 3C, 3F, 3M, 3P, 3S, 3U, 3W, 5A, 5B, 5C, 5D, 5E, 5F, 5G, 5H, 5J, 6A, 6B, 6C, 6D, 6H or 6K.
Converters Model(s) 3RS1706, 3RS1705 or 3RS1725, followed by -1 or -2, followed by F or K, followed by D, E or W, followed by 00.
Electronic overload relays Model(s) 3RB12, followed by 46, 53, 57 or 62, followed by 0F, 0K, 0L, 1E, 1P or 1Q, followed by B, G or M, followed
by 1, 2, 3 or 4, followed by 0 or 1.
Electronic timers Model(s) 3RP10 or 3RP20, followed by 00, 05, 20 or 25, followed by 1 or 2, followed by A or B, followed by P3, Q3 or W3,
followed by a number.
7PU1040, 7PU1140, 7PU1540, 7PU1640, 7PU2040, 7PU2540, 7PU2640, 7PU2643, 7PU3020, 7PU3040, 7PU3120, 7PU3140, 7PU3240, 7PU3243,
7PU3320, 7PU3340, 7PU3348, 7PU4020, 7PU4040, 7PU4120, 7PU4140, 7PU4220, 7PU4320, 7PU4340, 7PU4440, 7PU4520, 7PU4540, 7PU4620,
7PU4640, 7PU4720, 7PU5120, 7PU5220, 7PU5340, 7PU5720, 7PU6020, 7PU6040, 7PU6220, 7PU7020, 7PU7220, 7PU7243, 7PU8040, 7PU8043,
7PU8140, 7PU8143, 7PU8148, 7PU8340, 7PU8343, 7PU8348, 7PU8540, 7PU8543, 7PU8548, 7PU8640, 7PU8643, 7PU8648, 7PU8740, 7PU8748,
7PX1040, 7PX1540, 7PX7040, 7PX7140, 7PX7340, 7PX8220
Electronic timers with and/or auxiliary switches, open type Model(s) 3RA28, followed by 1, followed by 1, 2, 3, 4, 5 or 6 followed by -0, -1
or -2, followed by A, C, D, E or F, followed by W, followed by 1 or 2, followed by 0.
Electronic timers, open type Model(s) 3RT19, followed by 16 or 26, followed by -2C, -2D, -2F, -2G or -2L, followed by C, D, E, G, H, J, K or L,
followed by 0, 1, 2, 3 or 5, followed by 1.
EMC protective units Model(s) 3RT1916-1PA1, 3RT1916-1PA2, 3RT1916-1PA3, 3RT1916-1PB1, 3RT1916-1PB2, 3RT1916-1PB3, 3RT1916-
1PD1, 3RT1916-1PD2, 3RT1916-1PD3, 3RT2916-1PA1, 3RT2916-1PA2, 3RT2916-1PA3, 3RT2916-1PB1, 3RT2916-1PB2
Four to eight pole control relays, open type Model(s) 3RH2, followed by 1, 2, 3, 4 or 8, followed by 0, 1, 2, 3, 4, 5, 6, 7 or 8, followed by 0,
1, 2, 3, 4, 5, 6, 7 or 8, followed by -1, -2 or -4, followed by A, B, F, G, H, J, K, M, P, Q, V or W, followed by a character and a number.*
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?nam... UL_CSA_Zertifikate.pdf
07.11.2013
NKCR7.E44653 - Auxiliary Devices Certified for Canada Seite 3 von 6
3SE2 283 OGA 43, 3SE2 283 6GA 43, 3SE2283-0GA44, 3SE2283-6GA44, 3S32283-0GA53, 3SE2283-6GA53, 3SE2283-0GA54, 3SE2283-6GA54
3SE2283-0GA 44, 3SE2283-0GA 54, 3SE2283-6GA 44, 3SE2283-6GA 53, 3SE2283-6GA 54, SE2 283 6GA 43
3RK10, followed by 0, followed by 0, 1, 2, 3 or 4, followed by 0A, 0B, 0C, 0D, 0E, 0F or 0J, followed by A, B or C, followed by two numbers,
followed by one number, two characters and one number.
IO-link modules Model(s) 3RK50, followed by 1, followed by 0, followed by 0, followed by B or C, followed by A, followed by 0 or 1.*
Limit switches Model(s) 3SE2 or 3SE3, followed by 1, 3, 4 or 6, followed by 0, 2 or 7, followed by 0, 3, 4 or 6, followed by -0, -1, -3, -6, -7 or
-8, followed by A thru X, may be followed by W, X or V.*
3SE22, 3SE28, 3SE32 or 3SE38, followed by 00, 10, 20 or 30, followed by 0, 1, 3, 6, 7 or 8, followed by suffix letters A, AA, C, CV, D, DV, E, EV,
F, FV, G, GV, GW, GA, L, M, S, SV, R, RV, U, UW, V, VV, VW, W, WW, WV, XL, XT, XH, XX, may be followed by of letters and/or numbers up to
three digits for manufacturers use.
Limit switches Model(s) 3SE2 243-0XX, 3SE2 243-0XX18, 3SE2 243-0XX30, 3SE2 243-0XX38, 3SE2 243-0XX40, 3SE2 243-0XX48, 3SE2 243-
6XX40, 3SE2 243-6XX48, 3SE2 257-6XX, 3SE2 257-6XX18, 3SE2 257-6XX30, 3SE2 257-6XX38, 3SE2 257-6XX40, 3SE2 257-6XX48
Listed Accessories - Open type, current/voltage measuring modules Model(s) 6BK1700-3BA60-0AA0, 6BK1700-3BA70-0AA0, 6BK1700-
3BA80-0AA0
Listed Accessories - Open type,Current measuring modules Model(s) 6BK1700-3BA30-0AA0, 6BK1700-3BA40-0AA0, 6BK1700-3BA50-0AA0
Magnetically operated control switches Model(s) 3TH2, followed by 0, 1 or 2, followed by 22, 31, 40, 44, 53, 62, 71, 80, 81 or 82, followed
by 0, 1, 3, 4, 5 or 7, followed by A, B, D, E, F, G, H, J, K, L, P or Q
3TH80 or 3TH40, followed by 04, 13, 22, 31, 40, 92, 95 or 96, followed by 0A, 0B, 4B, 6B, 3B, 1E, 1F, 3K, 4K, 5K, 0H or OL.
3TH82 or 3TH42, followed by 44, 53, 62, 71, 74, 75, 80, 83, 84 or 93, followed by 0A, 0B, 3B, 4B, 6B, 1E, 1F, 3K, 4K, 5K, 0H or OL.*
3TH83 or 3TH43, followed by 10, 45, 46, 47, 48, 55, 64, 73, 82, 91 or 94, followed by 1H, 0A, 0B, 1E, 1F, 4B, 6B, 3B, 3K, 4K, 5K or 0H.
3TH85540A, 3TH85540B, 3TH85540H, 3TH85541E, 3TH85541F, 3TK2801OAC2, 3TK2801OAG2, 3TK2801OAN2, 3TK2801ODB4, 3TK2802OAC2,
3TK2802OAG2, 3TK2802OAN2, 3TK2802ODB4
Magnetically operated control switches, open type Model(s) 3TH40 or 3TH80, followed by 04, 13, 22, 31, 40, 92, 95 or 96, followed by OE,
OF, 3E, 3F, 1M, 2M, 3M, 4M, 5M or 6M.
3TH42 or 3TH82, followed by 44, 53, 62, 71, 74, 75, 80, 83, 84 or 93, followed by OE, OF, 3E, 3F, 1M, 2M, 3M, 4M, 5M or 6M.
3TH43 or 3TH83, followed by 10, 45, 46, 47, 48, 55, 64, 73, 82, 91 or 94, followed by OE, OF, 3E, 3F, 1M, 2M, 3M, 4M, 5M or 6M.
Modular systems (MSS) Model(s) 3RK3, followed by 11, 12, 13, 21, 22, 23, 24, 25, 31, 32 or 51, followed by 1 or 2, followed by 1 or 2,
followed by A or B, followed by A or C, followed by 0 or 1, followed by 0..*
Open type Industrial Control Equipment, stop modules, open type Model(s) 3SE6806-2CD00
Opening delay devices Model(s) 3RT1900-2HD810FB0, 3RT1900-2HD811FB0, 3TX4490-1A, 3TX4490-1H, 3TX4701-0AN1, 3TX4701-3AN1
Operator modules and accessories Model(s) 3RA2711-0EE11, 3RA6933-0A, 3RA6933-0B, 3RA6935-0A, 3RA6936-0A
Operators Model(s) 3SB3, followed by 0, 1, 2, 3, 4, 5 or 6, followed by 00, 01, 02, 03, 04, 05, 06, 07, 08, 10, 11, 12, 13, 14, 15, 16, 17, 18,
20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43 or 61, followed by 0A, 0B, 0C, 0D, 0E, 0N, 0P, 0Q,
1A, 1B, 1C, 1D, 1E, 1F, 1G, 1H, 1J, 1K, 1L, 1M, 1N, 1P, 1Q, 1R, 1S, 1T, 1U, 1V, 1W, 1X, 1Y, 2A, 2B, 2C, 2D, 2E, 2F, 2G, 2H, 2J, 2K, 2L, 2M, 2N,
2P, 2Q, 2R, 2S, 2T, 2U, 2V, 3P, 3Q, 3R, 3S, 3T, 3U, 3V, 3A, 3B, 3C, 3D, 3E, 3F, 3G, 3H, 4A, 4B, 4C, 4D, 4E, 4F, 4G, 4H, 4L, 4M, 4N, 4P, 4Q, 4R,
4S, 5A, 5B, 5C, 5D, 5E, 5F, 5G, 5L, 5M, 5N, 5P, 5Q, 5R, 5S, 6A, 6B, 6C, 7A, 7B, 7C, 7S, 7V, 7W, 8A, 8B, 8C, 8D, followed by A0, A1, A2, A3, A4,
A5, A6, A7, A8, B0, B1, B2, B3, B4, B5, B6, B7, C0, C1, C2, C3, C4, C5, C6, C7, C8, D0, D1, D2, D3, D4, D5, D6, E0, E1, E2, E3, E4, E5, E6, E7,
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?nam... UL_CSA_Zertifikate.pdf
07.11.2013
NKCR7.E44653 - Auxiliary Devices Certified for Canada Seite 4 von 6
F0, F1, F2, G0, G1, G2, G3, G4, G5, G6, H0, H1, H2, H3, H4, H5, H6, J0, J1, J2, J3, J4, J5, J6, K0, K1, K2, J2, K3, K4, K5, K6, L0, L1, L2, L3, L4,
L5, L6, M0, M1, M2, M3, M4, M5, M6, N0, N1, N2, N3, N4, N5, N6, P1 or R2.
Overload relays Model(s) 3RB2946-0EG, 3RB2946-0FH, 3RB2946-0MH, 3RB2956-0EG, 3RB2956-0FH, 3RB2956-0MH, 3RB2966-0EG, 3RB2966-
0FH, 3RB2966-0MH
Overload relays, accessories Model(s) 3RB2984*, 3RB2985*, 3RB2987*, 3UF7150-1AA0-0, 3UF7200-1AA00-0, 3UF7400-1AA00-0, 3UF7500-
1AA00-0, 3UF7700-1AA00-0, 3UF790-0AA00-0, 3UF7902-0AA00-0, 3UF7910-0AA00-0, 3UF7920-0AA00-0, 3UF7922-0AA00-0, 3UF793.-0.A00-0,
3UF7930-0AA00-0, 3UF7931-0AA00-0, 3UF7932-0AA00-0, 3UF7933-0AA00-0, 3UF7940-0AA00-0, 3UF7950-0AA00-0
Overload relays, basic units Model(s) 3RB22, 3RB23 or 3RB24, followed by 8, followed by 3, followed by -4A, followed by A or C, followed by
1.
Overload relays, current measuring modules Model(s) 3RB29, followed by 0, 4, 5 or 6, followed by 6, followed by -0 or -2, followed by B, D,
E, F, J, M, T or W, followed by G or H.*
Overload relays, current/voltage measuring module Model(s) 3RB29, followed by 46, 56 or 66, followed by -0EG, -0FH or -0MH.
Overload relays, digital modules and expansion modules Model(s) 3UF73, followed by 0, 1, 2 or 3, followed by 0 or 1, followed by -1A,
followed by B or U, followed by 0.*
Overload relays, open type, "Simicont System" Model(s) 3UA7, followed by 010, 011, 020 or 021, followed by 0 or 1, followed by A thru H, J
or K.
Overload relays, open type Model(s) 3UA50, 3UA52, 3UR50, 3UR52, 3UW10 or 3UW13 followed by 00, 01 or 40, followed by 0, 1, 2 or 7,
followed by A thru H, J, K or S.@
3UA54, 3UA55, 3UR54, 3UR55 or 3UW15, followed by 00, 01 or 40, followed by 0, 1, 2 or 8, followed by A, B, C, D, E, F, G, H, J, K, M, Q or R.*
3UA66002K, 3UA66003B, 3UA66003C, 3UA66003D, 3UA66003E, 3UA66402K, 3UA66403B, 3UA66403C, 3UA66403D, 3UA66403E, 3UA68003F,
3UA68003G, 3UA7900-0A, 3UA7900-0B, 3UA7900-0C, 3UA7901-0A
Overload relays, open type, with connection support 3UX1421, 3UX1421-0XA Model(s) 3UA58, 3UR58 or 3UW17, followed by 00, 01, 30
or 40, followed by 1, 2, 5 or 8, followed by A, B, C, D, E, F, G, T, P, U, V, Y or W.
Overspeed tripping devices Model(s) 3TK2810-0B41, 3TK2810-0B41-0AA0, 3TK2810-0B42, 3TK2810-0B42-0AA0, 3TK2810-0K41, 3TK2810-
0K41-0AA0, 3TK2810-0K42, 3TK2810-0K42-0AA0, 3TK2810-1B41-0AA0, 3TK2810-1B42-0AA0, 3TK2810-1BA41, 3TK2810-1K41, 3TK2810-
1K41-0AA0, 3TK2810-1K42, 3TK2810-1K42-0AA0, 3TK2810-1KA42
Pilot light units Model(s) 3SB1400-2A, 3SB1400-2B, 3SB1400-2C, 3SB1400-2D, 3SB1400-2E, 3SB1400-2L, 3SB1400-2P, 3SB1400-2Q,
3SB1420-2A, 3SB1420-3A, 3SB1420-3E, 3SB1430-2A, 3SB1430-3A, 3SB1430-3E
Pilot lights Model(s) 3SB3, followed by 0, 1, 2, 3, 4, 5 or 6, followed by 01, 04, 12, 17, 22, 23, 27, 36, 40, 44, 48, 52 or 61, followed by 6A, 6B
or 6C, followed by A0, A1, A2, A3, A4, A5, A6, A7, B6 or B7.
Push button unit and pilot light unit Model(s) 3SB3, followed by 0, 1, 2, 3, 4, 5 or 6, followed by 00, 03 or 20, followed by 1R, 1Q or 1P.
Push button units Model(s) 3SB14000A, 3SB14000B, 3SB14000C, 3SB14000G, 3SB14000H, 3SB14000J, 3SB14000R, 3SB14000S,
3SB14000V, 3SB14100B, 3SB14200B, 3SB14200C, 3SB14300B, 3SB14300C
Push button units and pilot light units Model(s) 3SB3, followed by 0, 1, 2, 3, 4, 5 or 6, followed by 00, 03 or 20, followed by 0A, 0B, 0C, 0D,
0E, 0J, 0K, 0H, 1A, 1C, 1F, 1G, 1H, 1L, 3A, 3C, 3F, 3M, 3P or 3S.
Pushbutton and pilot light units Model(s) 3SB2 followed by 0, 2, 3, 4 or 9 followed by 0, 1, 2, or 5 followed by a number 0 through 8.@
Pushbuttons, maintained Model(s) 3SB3, followed by 0, 1, 2, 3, 4, 5 or 6, followed by 00, 01, 02, 03, 04, 05, 06, 07, 08, 10, 11, 12, 13, 14,
15, 16, 17, 18, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 45, 46, 47, 50, 51, 53, 54 or 55,
followed by 0D, 1A, 1B, 1C, 1E, 1F, 1H, 1J, 1K, 1L, 1M, 1N, 1P, 1R, 1S, 1T, 1U, 1V, 1W, 1X or 1Y, followed by A0, A1, A2, A3, A4, A5, A6, A7,
A8, B0, B1, B2, B3, B4, B5, B6, B7, C0, C1, C2, C3, C4, C5, C6, C7, N6 or R2.
Pushbuttons, momentary illuminated Model(s) 3SB3, followed by 0, 1, 2, 3, 4, 5 or 6, followed by 01, 04, 05, 06, 07, 12, 13, 14, 15, 16, 18,
20, 21, 22, 24, 25, 26, 27, 28, 29, 30, 37, 38, 39, 40, 41, 42, 43, 45, 46, 47, 50, 51, 53, 54 or 55, followed by 0A, 0B, 0C, 0D, 1D, 1G, 1Q, 1S,
1V, 1W, 7S, 7V, 7W, 8B or 8D, followed by A0, A2, A3, A4, A5, A6, A7, A8, B0, B1, B3, B6, B7, C0, C1, C2, C3, C4, C5, C6 or C7.*
Pushbuttons, momentary non-illuminated Model(s) 3SB3, followed by 0, 1, 2, 3, 4, 5 or 6, followed by 00, 01, 02, 03, 08, 10, 11, 33, 34 or
35, followed by 0A, 0B, 0C, 1D, 1G, 1Q, 1S, 1V, 1W, 7A, 7B, 7C, 7S, 7V, 7W, 8A or 8C, followed by A1, A2, A3, A4, A5, A6, A7, A8, B0, B1, B2,
B3, B4, B5, B6, B7, C0, C1, C2, C3, C4, C5, C6, C7 or C8.
Relay interface modules Model(s) 3TX7004-1LB00, 3TX7004-1LB02, 3TX7004-1LF00, 3TX7014-1AM00, 3TX7014-1BB00, 3TX7014-1BB02,
3TX7014-1BE00, 3TX7014-1BE02, 3TX7014-1BF00, 3TX7014-1BF02, 3TX7014-1BM00, 3TX7014-1BM02, 3TX7015-1AM00, 3TX7015-1BB00,
3TX7015-1BB02, 3TX7015-1BE00, 3TX7015-1BE02, 3TX7015-1BF00, 3TX7015-1BF02, 3TX7015-1BM00, 3TX7015-1BM02
Remote reset thermal overload relays Model(s) 3RU1900-1A*, 3RU1900-1B*, 3RU1900-1C*, 3RU1900-2A*, 3RU2900-1A*, 3RU2900-1B*,
3RU2900-1C*, 3RU2900-2A*, 3RU5900-1A
Safety relays Model(s) 3TK28, followed by 20, 21, 22, 23, 24, 25, 26, 27, 28, 30, 34 or 35, followed by -1 or -2, followed by A, B or C, followed
by B2, B3, B4, J2, L2 or W3, followed by 0, 1, 2 or 4.
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?nam... UL_CSA_Zertifikate.pdf
07.11.2013
NKCR7.E44653 - Auxiliary Devices Certified for Canada Seite 5 von 6
Safety Relays Model(s) 3TK28, followed by 50, 51, 52, 53, 54, 56, 57 or 58, followed -1 or -2, followed by A, B or C, followed by B2, B3, B4, J2
or L2, followed by 0, 1, 2 or 3.*
Selector switches non-illuminated and keyed operator Model(s) 3SB3, followed by 0, 1, 2, 3, 4, 5 or 6, followed by 00, 01, 02, 03, 08, 10
or 11, followed by 2A, 2B, 2C, 2D, 2E, 2F, 2G, 2H, 2J, 2K, 2L, 2M, 2N, 2P, 2Q, 2R, 2S, 2T, 2U, 2V, 3P, 3Q, 3R, 3S, 3T, 3U, 3V, 3A, 3B, 3C, 3D,
3E, 3F, 3G, 4A, 4B, 4C, 4D, 4E, 4F, 4G, 4H, 4L, 4M, 4N, 4P, 4Q, 4R, 4S, 5A, 5B, 5C, 5D, 5E, 5F, 5G, 5L, 5M, 5N, 5P, 5Q, 5R or 5S, followed by
A1, A2, A3, A4, A5, A6, A7, B5, B6, B7, D0, D1, D2, D3, D4, D5, D6, E0, E1, E2, E3, E4, E5, E6, E7, F0, F1, F2, G0, G1, G2, G3, G4, G5, G6, H0,
H1, H2, H3, H4, H5, H6, J0, J1, J2, J3, J4, J5, J6, K0, K1, K2, K3, K4, K5, K6, L0, L1, L2, L3, L4, L5, L6, M0, M1, M2, M3, M4, M5, M6, N0, N1,
N2, N3, N4, N5 or N6.
Selector switches, illuminated operator Model(s) 3SB3, followed by 0, 1 or 5, followed by 01, followed by 2A, 2B, 2C, 2D, 2E, 2F, 2G, 2H, 2J,
2K, 2L, 2M, 2N, 2P, 2Q, 2R, 2S, 2T, 2U, 2V, 3P, 3Q, 3R, 3S, 3T, 3U or 3V, followed by A0, A2, A3, A4, A5, A6, A7, A8, B6 or B7.
Solid state coupling relays Model(s) 3RS18, followed by 00, followed by -1 or -2, followed by A thru H.*
Solid state overload relays Model(s) 3RB10, followed by 55, 56, 65 or 66, followed by -1 or -2, followed by F, G, K or L, followed by G0 or W0.
48, followed by A or B, followed by T, followed by A thru N, followed by 1 or 3, followed by S, followed by 00. (a)
958EB3SA (a), 958GB3SA (a), 958HB3SA (a), 958LDB3SA (a), 958LEB3SA (a), 958LFB3SA (a), 958LGB3SA (a), 958LHB3SA (a)
Solid state safety combinations Model(s) 3TK28, followed by 40, 41, 42 or 45, followed -1 or -2, followed by B, D, E, F, G or H, followed by
B4, followed by 0, 1, 2 or 4.*
Solid state thermal motor protectors Model(s) 3RN10, followed by 0, 1, 2 or 6, followed by 0, 1, 2 or 3, followed by -1 or -2, followed by A,
B, C, D, F or G , followed by B, C, G, M, K or W, followed by a number, followed by 0 or 1.
Solid state time relays Model(s) 3RP15, followed by 0, 1, 2, 3, 4, 5, 6, 7 or 8, followed by 0, 1, 2, 3, 4, 5, 6, 7 or 8, followed by -1 or -2,
followed by A, B, E, N, Q, R or S, followed by a character and a number, followed by any number or character, followed by any number or
character.
Summation current transformers Model(s) 3UL22011A, 3UL22011B, 3UL22012A, 3UL22012B, 3UL22013A, 3UL22013B, 3UL22014B,
3UL22015B, 3UL22021A, 3UL22021B, 3UL22022A, 3UL22022B, 3UL22023A, 3UL22023B, 3UL22024B, 3UL22025B, 3UL22031A, 3UL22031B,
3UL22032A, 3UL22032B, 3UL22033A, 3UL22033B, 3UL22034B, 3UL22035B
Synchronous timers Model(s) 7PR10, followed by 40, followed by 2 or 7, followed by A thru H, J thru N, P thru S or T, followed by 0 or 1,
followed by 0.
Temperature monitoring relays Model(s) 3RS10, 3RS11, 3RS14, 3RS15, 3RS20 or 3RS21, followed by 0, 1, 2, 3, 4 or 5, followed by a
number, followed by -1 or -2, followed by A thru H, followed by a character, followed by 0, 1, 2, 3, 4, 5, 6 or 8.*
Thermal overload relays Model(s) 3RU1126, followed by combination of 0, 1 or 4 and A thru K, followed by B or D, followed by 0 or 1.
3RU5116, followed by combination of 0 or 1 and A thru K, followed by B0 or C1, with connecting supports 3RU5916-3AA01.
3RU5126 followed by combination of 0, 1 or 4 and a letter A thru K, followed by B or D, followed by 0 or 1, with connecting supports 3RU5926-
3AA01.
Thermal overload relays Model(s) 3RU2126, followed by -1 or -4, followed by A, B, C, D, E, F, G, H, J, K, N or P, followed by B, C or J, followed
by 0 or 1.
Thermal overload relays, connecting supports Model(s) 3RU2916-3AA01, 3RU2916-3AC01, 3RU2926-3AA01, 3RU2926-3AC01, 3RU6916-
3AA01, 3RU6926-3AA01
Thermal overload relays, covers Model(s) 3RT2916-4EA13, 3RU2916-3BJ20, 3RU2916-3BJ21, 3RU2926-3BJ21, 3RV2908-0P, 3RV2928-4AA00
Time relays, open type Model(s) 7PV15, followed by 0, 1, 3, 4, 5 or 7, followed by 0, 1, 2, 3, 4, 5, 6, 7 or 8, followed by -1, followed by A or B,
followed by J30, N30, P30, Q30 or W30.*
Undervoltage tripping and shunt release units Model(s) 3RV19 or 3RV29, followed by 0, 1 or 2, followed by 2, followed by -1, -2 or -4,
followed by A, B, C or D, followed by B0, B4, F0, G6, M1, N0, N6, P0, Q0, S0, U0, V0 or V1.*
3TY, followed by 7, followed by 461, 481, 561 or 681, followed by 1 or 2, followed by A, B, E, F, G, K, L, N, P, Q, R, S, U, V, AA00, KA00 or
UA00.*
4S5309350-20
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?nam... UL_CSA_Zertifikate.pdf
07.11.2013
NKCR7.E44653 - Auxiliary Devices Certified for Canada Seite 6 von 6
Current monitoring relays, open type Model(s) 3RR2, followed by 1, 2 or 4, followed by 4, followed by 1 or 2, followed by -1 or -2, followed
by A or F, followed by A or W, followed by 3 or 4.*
Solid-state overload relays Model(s) 3RB3, followed by 0 or 1, followed by 1 or 2, followed by 3 or 6, followed by -1, -2 or -4, followed by R,
N, P, S, T, Q or V, followed by B or E, followed by 0.
Thermal overload relays Model(s) 3RU1116, followed by combination of 0 or 1 and A thru K, followed by B0, B1 or C1.
3RU2116, followed by combination of -0, -1 or -4 and A thru K followed by B, C or J, followed by 0, 1or 9, may be followed by numbers and/or
characters.
Three phase current measuring modules Model(s) 3UF76 followed by 0, followed by 0, followed by -1, followed by A, followed by B or U,
followed by 0, may be followed by suffix numbers and/or characters.
* - May be followed by a suffix of number(s) or/and letter(s) for manufacturers use or marketing difference only.
+ - Followed by a letter.
© 2013 UL LLC
When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment
database for additional information regarding this product's certification.
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up
Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-
misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with
permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the
following format: "© 2013 UL LLC".
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?nam... UL_CSA_Zertifikate.pdf
07.11.2013
PMArt.-N 58092 SiemnsSignumtype3SBC-UL ScertE4653
NKCR7.E44653
Auxiliary Devices Certified for Canada
Page Bottom
SIEMENS AG E44653
I IA CE CP R&D-VI 4
WERNER-VON-SIEMENS-STRASSE 48
92220 AMBERG, GERMANY
Accessories Model(s) 3RP1901, 3RP1902, 3RP1903, 3SB19*, 3SB29*, 3SB39*, 3SX, followed by numbers., 3SY, followed by numbers.
Accessories, connection cables Model(s) 3RA27, followed by any numbers and or characters, ends with E02, E03 or E11.
Accessory devices, cable connector, plug, separate actuator, actuator head Model(s) 3SE5000, may be followed by letters and/or
numbers or 3SY.. or 3SX.
AS-I moduls for compact starters, open type Model(s) 3RA6970-3A, 3RA6970-3B, 3RA6970-3C, 3RA6970-3D, 3RA6970-3E, 3RA6970-3F
AS-Interface adaptors Model(s) 3SF1.*, 3SF2.*, 3SF3.*, 3SF5.*, 3SF54*, 3SF55*, 3SF59*, 3SF7*
AS-Interface Fail-Safe Monitors Model(s) 3RK1105, followed by -1A or -1B, followed by E or G, followed by 04, followed by -0CA0, -1CA0,
-2CA0, -3CA0 or -4CA0.
AS-interfaces Model(s) 3RG9, followed by 0, followed by 0, 1, 2, 3 or 4, followed by 0, 1, 4, 5 or 8, followed by 0, followed by AA, AB, AC, AD,
AE, AF, AG, AH, AJ, AK, SB or SC, followed by 00.
3RK1 or 3RK2, followed by 1, 2 or 4, followed by 0, followed by 0, 1, 2, 5, 7 or 8, followed by -0, -1, -2, -3 or -8, followed by A thru N or S,
followed by A thru U.*
3RV59 or 3RV69, followed by 0, 1 or 2, followed by 2, followed by -1, -2 or -4 followed by A, B, C or D, followed by B0, B4, F0, G6, M1, N0, N6,
P0, Q0, S0, U0, V0 or V1.*
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?nam... UL_CSA_Zertifikate.pdf
07.11.2013
NKCR7.E44653 - Auxiliary Devices Certified for Canada Seite 2 von 6
3TX44, followed by 01, 02, 04, 11, 12, 13, 20, 22, 31, 40, followed by 0, 1 or 2, followed by A, B or G.
Auxiliary contact blocks, open type Model(s) 3RA6911-1A, 3RA6911-2A, 3RA6912-1A, 3RA6912-2A, 3RA6913-1A, 3RA6913-2A
Auxiliary devices proximity switches , "BERO" Model(s) 3RG4, followed by 0 or 1, followed by 1, 2, 3 or 4, followed by 1, 2, 3 or 4, followed
by 0, 2, 3 or 6, followed by A or K, followed by A, B or D, followed by 00.
Auxiliary devices, position switch and as-interface accessories, cable connectors, plugs, plugs in shafts Model(s) 3SE5000*
Auxiliary devices, speed, level, fault current, voltage monitoring relays Model(s) 3UG4, followed by 5, 6 or 8, followed by 01, 11, 12, 13,
14, 15, 16, 17, 18, 21, 22, 24, 25, 31, 32, 33, 41 or 51, followed by -1 or -2, followed by A thru L, followed by A, N, L, P, Q, R, S or W, followed
by a letter and a number.*
Auxillary Device: Accessories Model(s) Types 3ZY12 and 3ZY13 followed by suffix letters and or numbers.
Auxillary Device: Open type Relay Modules Model(s) Type 3SK1 followed by 1 or 2, followed by 1, 2 or 3, followed by 0, 1, 2 or 3, followed 0,
1 or 2 followed by A, B or C followed by B0, J2, L2, B4, B3, W2, or W3 followed by 0, 1, 2, or 4, may be followed by suffix letters and/or
numbers.
Communication modules, open type Model(s) 3RA27, followed by 1, followed by 1 or 2 followed by -0, -1 or -2, followed by A, B, C or D,
followed by A, B or E, followed by 00 or 10.
Communications-capable electronic overload relays, basic units Model(s) 3UF50, followed by 01, 11, 21, 31, 41 or 51, followed by -3A or
-3B, followed by B, J or N, followed by 0 or 1.
Communications-capable electronic overload relays, expansion modules Model(s) 3UF5100-0AB, 3UF5100-0AJ, 3UF5100-0AN
Connecting supports Model(s) 3RU5136 followed by combination of 0, 1 or 4 and a letter A thru K, followed by B or D, followed by 0 or 1, with
connecting supports 3RU5936-3AA01.
3RU5146, followed by combination of 4 and a letter D thru M followed by B or D, followed by 0 or 1, with connecting supports 3RU5946-3AA01.
Connection supports, for Types 3UA58, 3UR58 or 3UW17 Model(s) 3UX1421, 3UX1421-0XA
Contact blocks, lamp holders and transformers Model(s) 3SB34, followed by 00, 02, 03, 11, 20 or 23, followed by 0A, 0B, 0C, 0D, 0E, 0F,
0G, 0H, 0J, 0K, 0L, 0M, 0N, 0P, 0Q, 1A, 1B, 1C, 1D, 1F, 1G, 1H, 1L, 1M, 1N, 1PA, 1PB, 1PC, 1PD, 1PE, 1QA, 1QB, 1QC, 1QD, 1QE, 1RA, 1RB,
1RC, 1RD, 1RE, 2A, 2D, 2F, 2G, 2H, 3A, 3C, 3F, 3M, 3P, 3S, 3U, 3W, 5A, 5B, 5C, 5D, 5E, 5F, 5G, 5H, 5J, 6A, 6B, 6C, 6D, 6H or 6K.
Converters Model(s) 3RS1706, 3RS1705 or 3RS1725, followed by -1 or -2, followed by F or K, followed by D, E or W, followed by 00.
Electronic overload relays Model(s) 3RB12, followed by 46, 53, 57 or 62, followed by 0F, 0K, 0L, 1E, 1P or 1Q, followed by B, G or M, followed
by 1, 2, 3 or 4, followed by 0 or 1.
Electronic timers Model(s) 3RP10 or 3RP20, followed by 00, 05, 20 or 25, followed by 1 or 2, followed by A or B, followed by P3, Q3 or W3,
followed by a number.
7PU1040, 7PU1140, 7PU1540, 7PU1640, 7PU2040, 7PU2540, 7PU2640, 7PU2643, 7PU3020, 7PU3040, 7PU3120, 7PU3140, 7PU3240, 7PU3243,
7PU3320, 7PU3340, 7PU3348, 7PU4020, 7PU4040, 7PU4120, 7PU4140, 7PU4220, 7PU4320, 7PU4340, 7PU4440, 7PU4520, 7PU4540, 7PU4620,
7PU4640, 7PU4720, 7PU5120, 7PU5220, 7PU5340, 7PU5720, 7PU6020, 7PU6040, 7PU6220, 7PU7020, 7PU7220, 7PU7243, 7PU8040, 7PU8043,
7PU8140, 7PU8143, 7PU8148, 7PU8340, 7PU8343, 7PU8348, 7PU8540, 7PU8543, 7PU8548, 7PU8640, 7PU8643, 7PU8648, 7PU8740, 7PU8748,
7PX1040, 7PX1540, 7PX7040, 7PX7140, 7PX7340, 7PX8220
Electronic timers with and/or auxiliary switches, open type Model(s) 3RA28, followed by 1, followed by 1, 2, 3, 4, 5 or 6 followed by -0, -1
or -2, followed by A, C, D, E or F, followed by W, followed by 1 or 2, followed by 0.
Electronic timers, open type Model(s) 3RT19, followed by 16 or 26, followed by -2C, -2D, -2F, -2G or -2L, followed by C, D, E, G, H, J, K or L,
followed by 0, 1, 2, 3 or 5, followed by 1.
EMC protective units Model(s) 3RT1916-1PA1, 3RT1916-1PA2, 3RT1916-1PA3, 3RT1916-1PB1, 3RT1916-1PB2, 3RT1916-1PB3, 3RT1916-
1PD1, 3RT1916-1PD2, 3RT1916-1PD3, 3RT2916-1PA1, 3RT2916-1PA2, 3RT2916-1PA3, 3RT2916-1PB1, 3RT2916-1PB2
Four to eight pole control relays, open type Model(s) 3RH2, followed by 1, 2, 3, 4 or 8, followed by 0, 1, 2, 3, 4, 5, 6, 7 or 8, followed by 0,
1, 2, 3, 4, 5, 6, 7 or 8, followed by -1, -2 or -4, followed by A, B, F, G, H, J, K, M, P, Q, V or W, followed by a character and a number.*
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?nam... UL_CSA_Zertifikate.pdf
07.11.2013
NKCR7.E44653 - Auxiliary Devices Certified for Canada Seite 3 von 6
3SE2 283 OGA 43, 3SE2 283 6GA 43, 3SE2283-0GA44, 3SE2283-6GA44, 3S32283-0GA53, 3SE2283-6GA53, 3SE2283-0GA54, 3SE2283-6GA54
3SE2283-0GA 44, 3SE2283-0GA 54, 3SE2283-6GA 44, 3SE2283-6GA 53, 3SE2283-6GA 54, SE2 283 6GA 43
3RK10, followed by 0, followed by 0, 1, 2, 3 or 4, followed by 0A, 0B, 0C, 0D, 0E, 0F or 0J, followed by A, B or C, followed by two numbers,
followed by one number, two characters and one number.
IO-link modules Model(s) 3RK50, followed by 1, followed by 0, followed by 0, followed by B or C, followed by A, followed by 0 or 1.*
Limit switches Model(s) 3SE2 or 3SE3, followed by 1, 3, 4 or 6, followed by 0, 2 or 7, followed by 0, 3, 4 or 6, followed by -0, -1, -3, -6, -7 or
-8, followed by A thru X, may be followed by W, X or V.*
3SE22, 3SE28, 3SE32 or 3SE38, followed by 00, 10, 20 or 30, followed by 0, 1, 3, 6, 7 or 8, followed by suffix letters A, AA, C, CV, D, DV, E, EV,
F, FV, G, GV, GW, GA, L, M, S, SV, R, RV, U, UW, V, VV, VW, W, WW, WV, XL, XT, XH, XX, may be followed by of letters and/or numbers up to
three digits for manufacturers use.
Limit switches Model(s) 3SE2 243-0XX, 3SE2 243-0XX18, 3SE2 243-0XX30, 3SE2 243-0XX38, 3SE2 243-0XX40, 3SE2 243-0XX48, 3SE2 243-
6XX40, 3SE2 243-6XX48, 3SE2 257-6XX, 3SE2 257-6XX18, 3SE2 257-6XX30, 3SE2 257-6XX38, 3SE2 257-6XX40, 3SE2 257-6XX48
Listed Accessories - Open type, current/voltage measuring modules Model(s) 6BK1700-3BA60-0AA0, 6BK1700-3BA70-0AA0, 6BK1700-
3BA80-0AA0
Listed Accessories - Open type,Current measuring modules Model(s) 6BK1700-3BA30-0AA0, 6BK1700-3BA40-0AA0, 6BK1700-3BA50-0AA0
Magnetically operated control switches Model(s) 3TH2, followed by 0, 1 or 2, followed by 22, 31, 40, 44, 53, 62, 71, 80, 81 or 82, followed
by 0, 1, 3, 4, 5 or 7, followed by A, B, D, E, F, G, H, J, K, L, P or Q
3TH80 or 3TH40, followed by 04, 13, 22, 31, 40, 92, 95 or 96, followed by 0A, 0B, 4B, 6B, 3B, 1E, 1F, 3K, 4K, 5K, 0H or OL.
3TH82 or 3TH42, followed by 44, 53, 62, 71, 74, 75, 80, 83, 84 or 93, followed by 0A, 0B, 3B, 4B, 6B, 1E, 1F, 3K, 4K, 5K, 0H or OL.*
3TH83 or 3TH43, followed by 10, 45, 46, 47, 48, 55, 64, 73, 82, 91 or 94, followed by 1H, 0A, 0B, 1E, 1F, 4B, 6B, 3B, 3K, 4K, 5K or 0H.
3TH85540A, 3TH85540B, 3TH85540H, 3TH85541E, 3TH85541F, 3TK2801OAC2, 3TK2801OAG2, 3TK2801OAN2, 3TK2801ODB4, 3TK2802OAC2,
3TK2802OAG2, 3TK2802OAN2, 3TK2802ODB4
Magnetically operated control switches, open type Model(s) 3TH40 or 3TH80, followed by 04, 13, 22, 31, 40, 92, 95 or 96, followed by OE,
OF, 3E, 3F, 1M, 2M, 3M, 4M, 5M or 6M.
3TH42 or 3TH82, followed by 44, 53, 62, 71, 74, 75, 80, 83, 84 or 93, followed by OE, OF, 3E, 3F, 1M, 2M, 3M, 4M, 5M or 6M.
3TH43 or 3TH83, followed by 10, 45, 46, 47, 48, 55, 64, 73, 82, 91 or 94, followed by OE, OF, 3E, 3F, 1M, 2M, 3M, 4M, 5M or 6M.
Modular systems (MSS) Model(s) 3RK3, followed by 11, 12, 13, 21, 22, 23, 24, 25, 31, 32 or 51, followed by 1 or 2, followed by 1 or 2,
followed by A or B, followed by A or C, followed by 0 or 1, followed by 0..*
Open type Industrial Control Equipment, stop modules, open type Model(s) 3SE6806-2CD00
Opening delay devices Model(s) 3RT1900-2HD810FB0, 3RT1900-2HD811FB0, 3TX4490-1A, 3TX4490-1H, 3TX4701-0AN1, 3TX4701-3AN1
Operator modules and accessories Model(s) 3RA2711-0EE11, 3RA6933-0A, 3RA6933-0B, 3RA6935-0A, 3RA6936-0A
Operators Model(s) 3SB3, followed by 0, 1, 2, 3, 4, 5 or 6, followed by 00, 01, 02, 03, 04, 05, 06, 07, 08, 10, 11, 12, 13, 14, 15, 16, 17, 18,
20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43 or 61, followed by 0A, 0B, 0C, 0D, 0E, 0N, 0P, 0Q,
1A, 1B, 1C, 1D, 1E, 1F, 1G, 1H, 1J, 1K, 1L, 1M, 1N, 1P, 1Q, 1R, 1S, 1T, 1U, 1V, 1W, 1X, 1Y, 2A, 2B, 2C, 2D, 2E, 2F, 2G, 2H, 2J, 2K, 2L, 2M, 2N,
2P, 2Q, 2R, 2S, 2T, 2U, 2V, 3P, 3Q, 3R, 3S, 3T, 3U, 3V, 3A, 3B, 3C, 3D, 3E, 3F, 3G, 3H, 4A, 4B, 4C, 4D, 4E, 4F, 4G, 4H, 4L, 4M, 4N, 4P, 4Q, 4R,
4S, 5A, 5B, 5C, 5D, 5E, 5F, 5G, 5L, 5M, 5N, 5P, 5Q, 5R, 5S, 6A, 6B, 6C, 7A, 7B, 7C, 7S, 7V, 7W, 8A, 8B, 8C, 8D, followed by A0, A1, A2, A3, A4,
A5, A6, A7, A8, B0, B1, B2, B3, B4, B5, B6, B7, C0, C1, C2, C3, C4, C5, C6, C7, C8, D0, D1, D2, D3, D4, D5, D6, E0, E1, E2, E3, E4, E5, E6, E7,
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?nam... UL_CSA_Zertifikate.pdf
07.11.2013
NKCR7.E44653 - Auxiliary Devices Certified for Canada Seite 4 von 6
F0, F1, F2, G0, G1, G2, G3, G4, G5, G6, H0, H1, H2, H3, H4, H5, H6, J0, J1, J2, J3, J4, J5, J6, K0, K1, K2, J2, K3, K4, K5, K6, L0, L1, L2, L3, L4,
L5, L6, M0, M1, M2, M3, M4, M5, M6, N0, N1, N2, N3, N4, N5, N6, P1 or R2.
Overload relays Model(s) 3RB2946-0EG, 3RB2946-0FH, 3RB2946-0MH, 3RB2956-0EG, 3RB2956-0FH, 3RB2956-0MH, 3RB2966-0EG, 3RB2966-
0FH, 3RB2966-0MH
Overload relays, accessories Model(s) 3RB2984*, 3RB2985*, 3RB2987*, 3UF7150-1AA0-0, 3UF7200-1AA00-0, 3UF7400-1AA00-0, 3UF7500-
1AA00-0, 3UF7700-1AA00-0, 3UF790-0AA00-0, 3UF7902-0AA00-0, 3UF7910-0AA00-0, 3UF7920-0AA00-0, 3UF7922-0AA00-0, 3UF793.-0.A00-0,
3UF7930-0AA00-0, 3UF7931-0AA00-0, 3UF7932-0AA00-0, 3UF7933-0AA00-0, 3UF7940-0AA00-0, 3UF7950-0AA00-0
Overload relays, basic units Model(s) 3RB22, 3RB23 or 3RB24, followed by 8, followed by 3, followed by -4A, followed by A or C, followed by
1.
Overload relays, current measuring modules Model(s) 3RB29, followed by 0, 4, 5 or 6, followed by 6, followed by -0 or -2, followed by B, D,
E, F, J, M, T or W, followed by G or H.*
Overload relays, current/voltage measuring module Model(s) 3RB29, followed by 46, 56 or 66, followed by -0EG, -0FH or -0MH.
Overload relays, digital modules and expansion modules Model(s) 3UF73, followed by 0, 1, 2 or 3, followed by 0 or 1, followed by -1A,
followed by B or U, followed by 0.*
Overload relays, open type, "Simicont System" Model(s) 3UA7, followed by 010, 011, 020 or 021, followed by 0 or 1, followed by A thru H, J
or K.
Overload relays, open type Model(s) 3UA50, 3UA52, 3UR50, 3UR52, 3UW10 or 3UW13 followed by 00, 01 or 40, followed by 0, 1, 2 or 7,
followed by A thru H, J, K or S.@
3UA54, 3UA55, 3UR54, 3UR55 or 3UW15, followed by 00, 01 or 40, followed by 0, 1, 2 or 8, followed by A, B, C, D, E, F, G, H, J, K, M, Q or R.*
3UA66002K, 3UA66003B, 3UA66003C, 3UA66003D, 3UA66003E, 3UA66402K, 3UA66403B, 3UA66403C, 3UA66403D, 3UA66403E, 3UA68003F,
3UA68003G, 3UA7900-0A, 3UA7900-0B, 3UA7900-0C, 3UA7901-0A
Overload relays, open type, with connection support 3UX1421, 3UX1421-0XA Model(s) 3UA58, 3UR58 or 3UW17, followed by 00, 01, 30
or 40, followed by 1, 2, 5 or 8, followed by A, B, C, D, E, F, G, T, P, U, V, Y or W.
Overspeed tripping devices Model(s) 3TK2810-0B41, 3TK2810-0B41-0AA0, 3TK2810-0B42, 3TK2810-0B42-0AA0, 3TK2810-0K41, 3TK2810-
0K41-0AA0, 3TK2810-0K42, 3TK2810-0K42-0AA0, 3TK2810-1B41-0AA0, 3TK2810-1B42-0AA0, 3TK2810-1BA41, 3TK2810-1K41, 3TK2810-
1K41-0AA0, 3TK2810-1K42, 3TK2810-1K42-0AA0, 3TK2810-1KA42
Pilot light units Model(s) 3SB1400-2A, 3SB1400-2B, 3SB1400-2C, 3SB1400-2D, 3SB1400-2E, 3SB1400-2L, 3SB1400-2P, 3SB1400-2Q,
3SB1420-2A, 3SB1420-3A, 3SB1420-3E, 3SB1430-2A, 3SB1430-3A, 3SB1430-3E
Pilot lights Model(s) 3SB3, followed by 0, 1, 2, 3, 4, 5 or 6, followed by 01, 04, 12, 17, 22, 23, 27, 36, 40, 44, 48, 52 or 61, followed by 6A, 6B
or 6C, followed by A0, A1, A2, A3, A4, A5, A6, A7, B6 or B7.
Push button unit and pilot light unit Model(s) 3SB3, followed by 0, 1, 2, 3, 4, 5 or 6, followed by 00, 03 or 20, followed by 1R, 1Q or 1P.
Push button units Model(s) 3SB14000A, 3SB14000B, 3SB14000C, 3SB14000G, 3SB14000H, 3SB14000J, 3SB14000R, 3SB14000S,
3SB14000V, 3SB14100B, 3SB14200B, 3SB14200C, 3SB14300B, 3SB14300C
Push button units and pilot light units Model(s) 3SB3, followed by 0, 1, 2, 3, 4, 5 or 6, followed by 00, 03 or 20, followed by 0A, 0B, 0C, 0D,
0E, 0J, 0K, 0H, 1A, 1C, 1F, 1G, 1H, 1L, 3A, 3C, 3F, 3M, 3P or 3S.
Pushbutton and pilot light units Model(s) 3SB2 followed by 0, 2, 3, 4 or 9 followed by 0, 1, 2, or 5 followed by a number 0 through 8.@
Pushbuttons, maintained Model(s) 3SB3, followed by 0, 1, 2, 3, 4, 5 or 6, followed by 00, 01, 02, 03, 04, 05, 06, 07, 08, 10, 11, 12, 13, 14,
15, 16, 17, 18, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 45, 46, 47, 50, 51, 53, 54 or 55,
followed by 0D, 1A, 1B, 1C, 1E, 1F, 1H, 1J, 1K, 1L, 1M, 1N, 1P, 1R, 1S, 1T, 1U, 1V, 1W, 1X or 1Y, followed by A0, A1, A2, A3, A4, A5, A6, A7,
A8, B0, B1, B2, B3, B4, B5, B6, B7, C0, C1, C2, C3, C4, C5, C6, C7, N6 or R2.
Pushbuttons, momentary illuminated Model(s) 3SB3, followed by 0, 1, 2, 3, 4, 5 or 6, followed by 01, 04, 05, 06, 07, 12, 13, 14, 15, 16, 18,
20, 21, 22, 24, 25, 26, 27, 28, 29, 30, 37, 38, 39, 40, 41, 42, 43, 45, 46, 47, 50, 51, 53, 54 or 55, followed by 0A, 0B, 0C, 0D, 1D, 1G, 1Q, 1S,
1V, 1W, 7S, 7V, 7W, 8B or 8D, followed by A0, A2, A3, A4, A5, A6, A7, A8, B0, B1, B3, B6, B7, C0, C1, C2, C3, C4, C5, C6 or C7.*
Pushbuttons, momentary non-illuminated Model(s) 3SB3, followed by 0, 1, 2, 3, 4, 5 or 6, followed by 00, 01, 02, 03, 08, 10, 11, 33, 34 or
35, followed by 0A, 0B, 0C, 1D, 1G, 1Q, 1S, 1V, 1W, 7A, 7B, 7C, 7S, 7V, 7W, 8A or 8C, followed by A1, A2, A3, A4, A5, A6, A7, A8, B0, B1, B2,
B3, B4, B5, B6, B7, C0, C1, C2, C3, C4, C5, C6, C7 or C8.
Relay interface modules Model(s) 3TX7004-1LB00, 3TX7004-1LB02, 3TX7004-1LF00, 3TX7014-1AM00, 3TX7014-1BB00, 3TX7014-1BB02,
3TX7014-1BE00, 3TX7014-1BE02, 3TX7014-1BF00, 3TX7014-1BF02, 3TX7014-1BM00, 3TX7014-1BM02, 3TX7015-1AM00, 3TX7015-1BB00,
3TX7015-1BB02, 3TX7015-1BE00, 3TX7015-1BE02, 3TX7015-1BF00, 3TX7015-1BF02, 3TX7015-1BM00, 3TX7015-1BM02
Remote reset thermal overload relays Model(s) 3RU1900-1A*, 3RU1900-1B*, 3RU1900-1C*, 3RU1900-2A*, 3RU2900-1A*, 3RU2900-1B*,
3RU2900-1C*, 3RU2900-2A*, 3RU5900-1A
Safety relays Model(s) 3TK28, followed by 20, 21, 22, 23, 24, 25, 26, 27, 28, 30, 34 or 35, followed by -1 or -2, followed by A, B or C, followed
by B2, B3, B4, J2, L2 or W3, followed by 0, 1, 2 or 4.
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?nam... UL_CSA_Zertifikate.pdf
07.11.2013
NKCR7.E44653 - Auxiliary Devices Certified for Canada Seite 5 von 6
Safety Relays Model(s) 3TK28, followed by 50, 51, 52, 53, 54, 56, 57 or 58, followed -1 or -2, followed by A, B or C, followed by B2, B3, B4, J2
or L2, followed by 0, 1, 2 or 3.*
Selector switches non-illuminated and keyed operator Model(s) 3SB3, followed by 0, 1, 2, 3, 4, 5 or 6, followed by 00, 01, 02, 03, 08, 10
or 11, followed by 2A, 2B, 2C, 2D, 2E, 2F, 2G, 2H, 2J, 2K, 2L, 2M, 2N, 2P, 2Q, 2R, 2S, 2T, 2U, 2V, 3P, 3Q, 3R, 3S, 3T, 3U, 3V, 3A, 3B, 3C, 3D,
3E, 3F, 3G, 4A, 4B, 4C, 4D, 4E, 4F, 4G, 4H, 4L, 4M, 4N, 4P, 4Q, 4R, 4S, 5A, 5B, 5C, 5D, 5E, 5F, 5G, 5L, 5M, 5N, 5P, 5Q, 5R or 5S, followed by
A1, A2, A3, A4, A5, A6, A7, B5, B6, B7, D0, D1, D2, D3, D4, D5, D6, E0, E1, E2, E3, E4, E5, E6, E7, F0, F1, F2, G0, G1, G2, G3, G4, G5, G6, H0,
H1, H2, H3, H4, H5, H6, J0, J1, J2, J3, J4, J5, J6, K0, K1, K2, K3, K4, K5, K6, L0, L1, L2, L3, L4, L5, L6, M0, M1, M2, M3, M4, M5, M6, N0, N1,
N2, N3, N4, N5 or N6.
Selector switches, illuminated operator Model(s) 3SB3, followed by 0, 1 or 5, followed by 01, followed by 2A, 2B, 2C, 2D, 2E, 2F, 2G, 2H, 2J,
2K, 2L, 2M, 2N, 2P, 2Q, 2R, 2S, 2T, 2U, 2V, 3P, 3Q, 3R, 3S, 3T, 3U or 3V, followed by A0, A2, A3, A4, A5, A6, A7, A8, B6 or B7.
Solid state coupling relays Model(s) 3RS18, followed by 00, followed by -1 or -2, followed by A thru H.*
Solid state overload relays Model(s) 3RB10, followed by 55, 56, 65 or 66, followed by -1 or -2, followed by F, G, K or L, followed by G0 or W0.
48, followed by A or B, followed by T, followed by A thru N, followed by 1 or 3, followed by S, followed by 00. (a)
958EB3SA (a), 958GB3SA (a), 958HB3SA (a), 958LDB3SA (a), 958LEB3SA (a), 958LFB3SA (a), 958LGB3SA (a), 958LHB3SA (a)
Solid state safety combinations Model(s) 3TK28, followed by 40, 41, 42 or 45, followed -1 or -2, followed by B, D, E, F, G or H, followed by
B4, followed by 0, 1, 2 or 4.*
Solid state thermal motor protectors Model(s) 3RN10, followed by 0, 1, 2 or 6, followed by 0, 1, 2 or 3, followed by -1 or -2, followed by A,
B, C, D, F or G , followed by B, C, G, M, K or W, followed by a number, followed by 0 or 1.
Solid state time relays Model(s) 3RP15, followed by 0, 1, 2, 3, 4, 5, 6, 7 or 8, followed by 0, 1, 2, 3, 4, 5, 6, 7 or 8, followed by -1 or -2,
followed by A, B, E, N, Q, R or S, followed by a character and a number, followed by any number or character, followed by any number or
character.
Summation current transformers Model(s) 3UL22011A, 3UL22011B, 3UL22012A, 3UL22012B, 3UL22013A, 3UL22013B, 3UL22014B,
3UL22015B, 3UL22021A, 3UL22021B, 3UL22022A, 3UL22022B, 3UL22023A, 3UL22023B, 3UL22024B, 3UL22025B, 3UL22031A, 3UL22031B,
3UL22032A, 3UL22032B, 3UL22033A, 3UL22033B, 3UL22034B, 3UL22035B
Synchronous timers Model(s) 7PR10, followed by 40, followed by 2 or 7, followed by A thru H, J thru N, P thru S or T, followed by 0 or 1,
followed by 0.
Temperature monitoring relays Model(s) 3RS10, 3RS11, 3RS14, 3RS15, 3RS20 or 3RS21, followed by 0, 1, 2, 3, 4 or 5, followed by a
number, followed by -1 or -2, followed by A thru H, followed by a character, followed by 0, 1, 2, 3, 4, 5, 6 or 8.*
Thermal overload relays Model(s) 3RU1126, followed by combination of 0, 1 or 4 and A thru K, followed by B or D, followed by 0 or 1.
3RU5116, followed by combination of 0 or 1 and A thru K, followed by B0 or C1, with connecting supports 3RU5916-3AA01.
3RU5126 followed by combination of 0, 1 or 4 and a letter A thru K, followed by B or D, followed by 0 or 1, with connecting supports 3RU5926-
3AA01.
Thermal overload relays Model(s) 3RU2126, followed by -1 or -4, followed by A, B, C, D, E, F, G, H, J, K, N or P, followed by B, C or J, followed
by 0 or 1.
Thermal overload relays, connecting supports Model(s) 3RU2916-3AA01, 3RU2916-3AC01, 3RU2926-3AA01, 3RU2926-3AC01, 3RU6916-
3AA01, 3RU6926-3AA01
Thermal overload relays, covers Model(s) 3RT2916-4EA13, 3RU2916-3BJ20, 3RU2916-3BJ21, 3RU2926-3BJ21, 3RV2908-0P, 3RV2928-4AA00
Time relays, open type Model(s) 7PV15, followed by 0, 1, 3, 4, 5 or 7, followed by 0, 1, 2, 3, 4, 5, 6, 7 or 8, followed by -1, followed by A or B,
followed by J30, N30, P30, Q30 or W30.*
Undervoltage tripping and shunt release units Model(s) 3RV19 or 3RV29, followed by 0, 1 or 2, followed by 2, followed by -1, -2 or -4,
followed by A, B, C or D, followed by B0, B4, F0, G6, M1, N0, N6, P0, Q0, S0, U0, V0 or V1.*
3TY, followed by 7, followed by 461, 481, 561 or 681, followed by 1 or 2, followed by A, B, E, F, G, K, L, N, P, Q, R, S, U, V, AA00, KA00 or
UA00.*
4S5309350-20
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?nam... UL_CSA_Zertifikate.pdf
07.11.2013
NKCR7.E44653 - Auxiliary Devices Certified for Canada Seite 6 von 6
Current monitoring relays, open type Model(s) 3RR2, followed by 1, 2 or 4, followed by 4, followed by 1 or 2, followed by -1 or -2, followed
by A or F, followed by A or W, followed by 3 or 4.*
Solid-state overload relays Model(s) 3RB3, followed by 0 or 1, followed by 1 or 2, followed by 3 or 6, followed by -1, -2 or -4, followed by R,
N, P, S, T, Q or V, followed by B or E, followed by 0.
Thermal overload relays Model(s) 3RU1116, followed by combination of 0 or 1 and A thru K, followed by B0, B1 or C1.
3RU2116, followed by combination of -0, -1 or -4 and A thru K followed by B, C or J, followed by 0, 1or 9, may be followed by numbers and/or
characters.
Three phase current measuring modules Model(s) 3UF76 followed by 0, followed by 0, followed by -1, followed by A, followed by B or U,
followed by 0, may be followed by suffix numbers and/or characters.
* - May be followed by a suffix of number(s) or/and letter(s) for manufacturers use or marketing difference only.
+ - Followed by a letter.
© 2013 UL LLC
When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment
database for additional information regarding this product's certification.
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up
Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-
misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with
permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the
following format: "© 2013 UL LLC".
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?nam... UL_CSA_Zertifikate.pdf
07.11.2013
PMArt.-N 580931SiemnsSignumtype3SBC-UL ScertE4653
NKCR7.E44653
Auxiliary Devices Certified for Canada
Page Bottom
SIEMENS AG E44653
I IA CE CP R&D-VI 4
WERNER-VON-SIEMENS-STRASSE 48
92220 AMBERG, GERMANY
Accessories Model(s) 3RP1901, 3RP1902, 3RP1903, 3SB19*, 3SB29*, 3SB39*, 3SX, followed by numbers., 3SY, followed by numbers.
Accessories, connection cables Model(s) 3RA27, followed by any numbers and or characters, ends with E02, E03 or E11.
Accessory devices, cable connector, plug, separate actuator, actuator head Model(s) 3SE5000, may be followed by letters and/or
numbers or 3SY.. or 3SX.
AS-I moduls for compact starters, open type Model(s) 3RA6970-3A, 3RA6970-3B, 3RA6970-3C, 3RA6970-3D, 3RA6970-3E, 3RA6970-3F
AS-Interface adaptors Model(s) 3SF1.*, 3SF2.*, 3SF3.*, 3SF5.*, 3SF54*, 3SF55*, 3SF59*, 3SF7*
AS-Interface Fail-Safe Monitors Model(s) 3RK1105, followed by -1A or -1B, followed by E or G, followed by 04, followed by -0CA0, -1CA0,
-2CA0, -3CA0 or -4CA0.
AS-interfaces Model(s) 3RG9, followed by 0, followed by 0, 1, 2, 3 or 4, followed by 0, 1, 4, 5 or 8, followed by 0, followed by AA, AB, AC, AD,
AE, AF, AG, AH, AJ, AK, SB or SC, followed by 00.
3RK1 or 3RK2, followed by 1, 2 or 4, followed by 0, followed by 0, 1, 2, 5, 7 or 8, followed by -0, -1, -2, -3 or -8, followed by A thru N or S,
followed by A thru U.*
3RV59 or 3RV69, followed by 0, 1 or 2, followed by 2, followed by -1, -2 or -4 followed by A, B, C or D, followed by B0, B4, F0, G6, M1, N0, N6,
P0, Q0, S0, U0, V0 or V1.*
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?nam... UL_CSA_Zertifikate.pdf
07.11.2013
NKCR7.E44653 - Auxiliary Devices Certified for Canada Seite 2 von 6
3TX44, followed by 01, 02, 04, 11, 12, 13, 20, 22, 31, 40, followed by 0, 1 or 2, followed by A, B or G.
Auxiliary contact blocks, open type Model(s) 3RA6911-1A, 3RA6911-2A, 3RA6912-1A, 3RA6912-2A, 3RA6913-1A, 3RA6913-2A
Auxiliary devices proximity switches , "BERO" Model(s) 3RG4, followed by 0 or 1, followed by 1, 2, 3 or 4, followed by 1, 2, 3 or 4, followed
by 0, 2, 3 or 6, followed by A or K, followed by A, B or D, followed by 00.
Auxiliary devices, position switch and as-interface accessories, cable connectors, plugs, plugs in shafts Model(s) 3SE5000*
Auxiliary devices, speed, level, fault current, voltage monitoring relays Model(s) 3UG4, followed by 5, 6 or 8, followed by 01, 11, 12, 13,
14, 15, 16, 17, 18, 21, 22, 24, 25, 31, 32, 33, 41 or 51, followed by -1 or -2, followed by A thru L, followed by A, N, L, P, Q, R, S or W, followed
by a letter and a number.*
Auxillary Device: Accessories Model(s) Types 3ZY12 and 3ZY13 followed by suffix letters and or numbers.
Auxillary Device: Open type Relay Modules Model(s) Type 3SK1 followed by 1 or 2, followed by 1, 2 or 3, followed by 0, 1, 2 or 3, followed 0,
1 or 2 followed by A, B or C followed by B0, J2, L2, B4, B3, W2, or W3 followed by 0, 1, 2, or 4, may be followed by suffix letters and/or
numbers.
Communication modules, open type Model(s) 3RA27, followed by 1, followed by 1 or 2 followed by -0, -1 or -2, followed by A, B, C or D,
followed by A, B or E, followed by 00 or 10.
Communications-capable electronic overload relays, basic units Model(s) 3UF50, followed by 01, 11, 21, 31, 41 or 51, followed by -3A or
-3B, followed by B, J or N, followed by 0 or 1.
Communications-capable electronic overload relays, expansion modules Model(s) 3UF5100-0AB, 3UF5100-0AJ, 3UF5100-0AN
Connecting supports Model(s) 3RU5136 followed by combination of 0, 1 or 4 and a letter A thru K, followed by B or D, followed by 0 or 1, with
connecting supports 3RU5936-3AA01.
3RU5146, followed by combination of 4 and a letter D thru M followed by B or D, followed by 0 or 1, with connecting supports 3RU5946-3AA01.
Connection supports, for Types 3UA58, 3UR58 or 3UW17 Model(s) 3UX1421, 3UX1421-0XA
Contact blocks, lamp holders and transformers Model(s) 3SB34, followed by 00, 02, 03, 11, 20 or 23, followed by 0A, 0B, 0C, 0D, 0E, 0F,
0G, 0H, 0J, 0K, 0L, 0M, 0N, 0P, 0Q, 1A, 1B, 1C, 1D, 1F, 1G, 1H, 1L, 1M, 1N, 1PA, 1PB, 1PC, 1PD, 1PE, 1QA, 1QB, 1QC, 1QD, 1QE, 1RA, 1RB,
1RC, 1RD, 1RE, 2A, 2D, 2F, 2G, 2H, 3A, 3C, 3F, 3M, 3P, 3S, 3U, 3W, 5A, 5B, 5C, 5D, 5E, 5F, 5G, 5H, 5J, 6A, 6B, 6C, 6D, 6H or 6K.
Converters Model(s) 3RS1706, 3RS1705 or 3RS1725, followed by -1 or -2, followed by F or K, followed by D, E or W, followed by 00.
Electronic overload relays Model(s) 3RB12, followed by 46, 53, 57 or 62, followed by 0F, 0K, 0L, 1E, 1P or 1Q, followed by B, G or M, followed
by 1, 2, 3 or 4, followed by 0 or 1.
Electronic timers Model(s) 3RP10 or 3RP20, followed by 00, 05, 20 or 25, followed by 1 or 2, followed by A or B, followed by P3, Q3 or W3,
followed by a number.
7PU1040, 7PU1140, 7PU1540, 7PU1640, 7PU2040, 7PU2540, 7PU2640, 7PU2643, 7PU3020, 7PU3040, 7PU3120, 7PU3140, 7PU3240, 7PU3243,
7PU3320, 7PU3340, 7PU3348, 7PU4020, 7PU4040, 7PU4120, 7PU4140, 7PU4220, 7PU4320, 7PU4340, 7PU4440, 7PU4520, 7PU4540, 7PU4620,
7PU4640, 7PU4720, 7PU5120, 7PU5220, 7PU5340, 7PU5720, 7PU6020, 7PU6040, 7PU6220, 7PU7020, 7PU7220, 7PU7243, 7PU8040, 7PU8043,
7PU8140, 7PU8143, 7PU8148, 7PU8340, 7PU8343, 7PU8348, 7PU8540, 7PU8543, 7PU8548, 7PU8640, 7PU8643, 7PU8648, 7PU8740, 7PU8748,
7PX1040, 7PX1540, 7PX7040, 7PX7140, 7PX7340, 7PX8220
Electronic timers with and/or auxiliary switches, open type Model(s) 3RA28, followed by 1, followed by 1, 2, 3, 4, 5 or 6 followed by -0, -1
or -2, followed by A, C, D, E or F, followed by W, followed by 1 or 2, followed by 0.
Electronic timers, open type Model(s) 3RT19, followed by 16 or 26, followed by -2C, -2D, -2F, -2G or -2L, followed by C, D, E, G, H, J, K or L,
followed by 0, 1, 2, 3 or 5, followed by 1.
EMC protective units Model(s) 3RT1916-1PA1, 3RT1916-1PA2, 3RT1916-1PA3, 3RT1916-1PB1, 3RT1916-1PB2, 3RT1916-1PB3, 3RT1916-
1PD1, 3RT1916-1PD2, 3RT1916-1PD3, 3RT2916-1PA1, 3RT2916-1PA2, 3RT2916-1PA3, 3RT2916-1PB1, 3RT2916-1PB2
Four to eight pole control relays, open type Model(s) 3RH2, followed by 1, 2, 3, 4 or 8, followed by 0, 1, 2, 3, 4, 5, 6, 7 or 8, followed by 0,
1, 2, 3, 4, 5, 6, 7 or 8, followed by -1, -2 or -4, followed by A, B, F, G, H, J, K, M, P, Q, V or W, followed by a character and a number.*
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?nam... UL_CSA_Zertifikate.pdf
07.11.2013
NKCR7.E44653 - Auxiliary Devices Certified for Canada Seite 3 von 6
3SE2 283 OGA 43, 3SE2 283 6GA 43, 3SE2283-0GA44, 3SE2283-6GA44, 3S32283-0GA53, 3SE2283-6GA53, 3SE2283-0GA54, 3SE2283-6GA54
3SE2283-0GA 44, 3SE2283-0GA 54, 3SE2283-6GA 44, 3SE2283-6GA 53, 3SE2283-6GA 54, SE2 283 6GA 43
3RK10, followed by 0, followed by 0, 1, 2, 3 or 4, followed by 0A, 0B, 0C, 0D, 0E, 0F or 0J, followed by A, B or C, followed by two numbers,
followed by one number, two characters and one number.
IO-link modules Model(s) 3RK50, followed by 1, followed by 0, followed by 0, followed by B or C, followed by A, followed by 0 or 1.*
Limit switches Model(s) 3SE2 or 3SE3, followed by 1, 3, 4 or 6, followed by 0, 2 or 7, followed by 0, 3, 4 or 6, followed by -0, -1, -3, -6, -7 or
-8, followed by A thru X, may be followed by W, X or V.*
3SE22, 3SE28, 3SE32 or 3SE38, followed by 00, 10, 20 or 30, followed by 0, 1, 3, 6, 7 or 8, followed by suffix letters A, AA, C, CV, D, DV, E, EV,
F, FV, G, GV, GW, GA, L, M, S, SV, R, RV, U, UW, V, VV, VW, W, WW, WV, XL, XT, XH, XX, may be followed by of letters and/or numbers up to
three digits for manufacturers use.
Limit switches Model(s) 3SE2 243-0XX, 3SE2 243-0XX18, 3SE2 243-0XX30, 3SE2 243-0XX38, 3SE2 243-0XX40, 3SE2 243-0XX48, 3SE2 243-
6XX40, 3SE2 243-6XX48, 3SE2 257-6XX, 3SE2 257-6XX18, 3SE2 257-6XX30, 3SE2 257-6XX38, 3SE2 257-6XX40, 3SE2 257-6XX48
Listed Accessories - Open type, current/voltage measuring modules Model(s) 6BK1700-3BA60-0AA0, 6BK1700-3BA70-0AA0, 6BK1700-
3BA80-0AA0
Listed Accessories - Open type,Current measuring modules Model(s) 6BK1700-3BA30-0AA0, 6BK1700-3BA40-0AA0, 6BK1700-3BA50-0AA0
Magnetically operated control switches Model(s) 3TH2, followed by 0, 1 or 2, followed by 22, 31, 40, 44, 53, 62, 71, 80, 81 or 82, followed
by 0, 1, 3, 4, 5 or 7, followed by A, B, D, E, F, G, H, J, K, L, P or Q
3TH80 or 3TH40, followed by 04, 13, 22, 31, 40, 92, 95 or 96, followed by 0A, 0B, 4B, 6B, 3B, 1E, 1F, 3K, 4K, 5K, 0H or OL.
3TH82 or 3TH42, followed by 44, 53, 62, 71, 74, 75, 80, 83, 84 or 93, followed by 0A, 0B, 3B, 4B, 6B, 1E, 1F, 3K, 4K, 5K, 0H or OL.*
3TH83 or 3TH43, followed by 10, 45, 46, 47, 48, 55, 64, 73, 82, 91 or 94, followed by 1H, 0A, 0B, 1E, 1F, 4B, 6B, 3B, 3K, 4K, 5K or 0H.
3TH85540A, 3TH85540B, 3TH85540H, 3TH85541E, 3TH85541F, 3TK2801OAC2, 3TK2801OAG2, 3TK2801OAN2, 3TK2801ODB4, 3TK2802OAC2,
3TK2802OAG2, 3TK2802OAN2, 3TK2802ODB4
Magnetically operated control switches, open type Model(s) 3TH40 or 3TH80, followed by 04, 13, 22, 31, 40, 92, 95 or 96, followed by OE,
OF, 3E, 3F, 1M, 2M, 3M, 4M, 5M or 6M.
3TH42 or 3TH82, followed by 44, 53, 62, 71, 74, 75, 80, 83, 84 or 93, followed by OE, OF, 3E, 3F, 1M, 2M, 3M, 4M, 5M or 6M.
3TH43 or 3TH83, followed by 10, 45, 46, 47, 48, 55, 64, 73, 82, 91 or 94, followed by OE, OF, 3E, 3F, 1M, 2M, 3M, 4M, 5M or 6M.
Modular systems (MSS) Model(s) 3RK3, followed by 11, 12, 13, 21, 22, 23, 24, 25, 31, 32 or 51, followed by 1 or 2, followed by 1 or 2,
followed by A or B, followed by A or C, followed by 0 or 1, followed by 0..*
Open type Industrial Control Equipment, stop modules, open type Model(s) 3SE6806-2CD00
Opening delay devices Model(s) 3RT1900-2HD810FB0, 3RT1900-2HD811FB0, 3TX4490-1A, 3TX4490-1H, 3TX4701-0AN1, 3TX4701-3AN1
Operator modules and accessories Model(s) 3RA2711-0EE11, 3RA6933-0A, 3RA6933-0B, 3RA6935-0A, 3RA6936-0A
Operators Model(s) 3SB3, followed by 0, 1, 2, 3, 4, 5 or 6, followed by 00, 01, 02, 03, 04, 05, 06, 07, 08, 10, 11, 12, 13, 14, 15, 16, 17, 18,
20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43 or 61, followed by 0A, 0B, 0C, 0D, 0E, 0N, 0P, 0Q,
1A, 1B, 1C, 1D, 1E, 1F, 1G, 1H, 1J, 1K, 1L, 1M, 1N, 1P, 1Q, 1R, 1S, 1T, 1U, 1V, 1W, 1X, 1Y, 2A, 2B, 2C, 2D, 2E, 2F, 2G, 2H, 2J, 2K, 2L, 2M, 2N,
2P, 2Q, 2R, 2S, 2T, 2U, 2V, 3P, 3Q, 3R, 3S, 3T, 3U, 3V, 3A, 3B, 3C, 3D, 3E, 3F, 3G, 3H, 4A, 4B, 4C, 4D, 4E, 4F, 4G, 4H, 4L, 4M, 4N, 4P, 4Q, 4R,
4S, 5A, 5B, 5C, 5D, 5E, 5F, 5G, 5L, 5M, 5N, 5P, 5Q, 5R, 5S, 6A, 6B, 6C, 7A, 7B, 7C, 7S, 7V, 7W, 8A, 8B, 8C, 8D, followed by A0, A1, A2, A3, A4,
A5, A6, A7, A8, B0, B1, B2, B3, B4, B5, B6, B7, C0, C1, C2, C3, C4, C5, C6, C7, C8, D0, D1, D2, D3, D4, D5, D6, E0, E1, E2, E3, E4, E5, E6, E7,
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?nam... UL_CSA_Zertifikate.pdf
07.11.2013
NKCR7.E44653 - Auxiliary Devices Certified for Canada Seite 4 von 6
F0, F1, F2, G0, G1, G2, G3, G4, G5, G6, H0, H1, H2, H3, H4, H5, H6, J0, J1, J2, J3, J4, J5, J6, K0, K1, K2, J2, K3, K4, K5, K6, L0, L1, L2, L3, L4,
L5, L6, M0, M1, M2, M3, M4, M5, M6, N0, N1, N2, N3, N4, N5, N6, P1 or R2.
Overload relays Model(s) 3RB2946-0EG, 3RB2946-0FH, 3RB2946-0MH, 3RB2956-0EG, 3RB2956-0FH, 3RB2956-0MH, 3RB2966-0EG, 3RB2966-
0FH, 3RB2966-0MH
Overload relays, accessories Model(s) 3RB2984*, 3RB2985*, 3RB2987*, 3UF7150-1AA0-0, 3UF7200-1AA00-0, 3UF7400-1AA00-0, 3UF7500-
1AA00-0, 3UF7700-1AA00-0, 3UF790-0AA00-0, 3UF7902-0AA00-0, 3UF7910-0AA00-0, 3UF7920-0AA00-0, 3UF7922-0AA00-0, 3UF793.-0.A00-0,
3UF7930-0AA00-0, 3UF7931-0AA00-0, 3UF7932-0AA00-0, 3UF7933-0AA00-0, 3UF7940-0AA00-0, 3UF7950-0AA00-0
Overload relays, basic units Model(s) 3RB22, 3RB23 or 3RB24, followed by 8, followed by 3, followed by -4A, followed by A or C, followed by
1.
Overload relays, current measuring modules Model(s) 3RB29, followed by 0, 4, 5 or 6, followed by 6, followed by -0 or -2, followed by B, D,
E, F, J, M, T or W, followed by G or H.*
Overload relays, current/voltage measuring module Model(s) 3RB29, followed by 46, 56 or 66, followed by -0EG, -0FH or -0MH.
Overload relays, digital modules and expansion modules Model(s) 3UF73, followed by 0, 1, 2 or 3, followed by 0 or 1, followed by -1A,
followed by B or U, followed by 0.*
Overload relays, open type, "Simicont System" Model(s) 3UA7, followed by 010, 011, 020 or 021, followed by 0 or 1, followed by A thru H, J
or K.
Overload relays, open type Model(s) 3UA50, 3UA52, 3UR50, 3UR52, 3UW10 or 3UW13 followed by 00, 01 or 40, followed by 0, 1, 2 or 7,
followed by A thru H, J, K or S.@
3UA54, 3UA55, 3UR54, 3UR55 or 3UW15, followed by 00, 01 or 40, followed by 0, 1, 2 or 8, followed by A, B, C, D, E, F, G, H, J, K, M, Q or R.*
3UA66002K, 3UA66003B, 3UA66003C, 3UA66003D, 3UA66003E, 3UA66402K, 3UA66403B, 3UA66403C, 3UA66403D, 3UA66403E, 3UA68003F,
3UA68003G, 3UA7900-0A, 3UA7900-0B, 3UA7900-0C, 3UA7901-0A
Overload relays, open type, with connection support 3UX1421, 3UX1421-0XA Model(s) 3UA58, 3UR58 or 3UW17, followed by 00, 01, 30
or 40, followed by 1, 2, 5 or 8, followed by A, B, C, D, E, F, G, T, P, U, V, Y or W.
Overspeed tripping devices Model(s) 3TK2810-0B41, 3TK2810-0B41-0AA0, 3TK2810-0B42, 3TK2810-0B42-0AA0, 3TK2810-0K41, 3TK2810-
0K41-0AA0, 3TK2810-0K42, 3TK2810-0K42-0AA0, 3TK2810-1B41-0AA0, 3TK2810-1B42-0AA0, 3TK2810-1BA41, 3TK2810-1K41, 3TK2810-
1K41-0AA0, 3TK2810-1K42, 3TK2810-1K42-0AA0, 3TK2810-1KA42
Pilot light units Model(s) 3SB1400-2A, 3SB1400-2B, 3SB1400-2C, 3SB1400-2D, 3SB1400-2E, 3SB1400-2L, 3SB1400-2P, 3SB1400-2Q,
3SB1420-2A, 3SB1420-3A, 3SB1420-3E, 3SB1430-2A, 3SB1430-3A, 3SB1430-3E
Pilot lights Model(s) 3SB3, followed by 0, 1, 2, 3, 4, 5 or 6, followed by 01, 04, 12, 17, 22, 23, 27, 36, 40, 44, 48, 52 or 61, followed by 6A, 6B
or 6C, followed by A0, A1, A2, A3, A4, A5, A6, A7, B6 or B7.
Push button unit and pilot light unit Model(s) 3SB3, followed by 0, 1, 2, 3, 4, 5 or 6, followed by 00, 03 or 20, followed by 1R, 1Q or 1P.
Push button units Model(s) 3SB14000A, 3SB14000B, 3SB14000C, 3SB14000G, 3SB14000H, 3SB14000J, 3SB14000R, 3SB14000S,
3SB14000V, 3SB14100B, 3SB14200B, 3SB14200C, 3SB14300B, 3SB14300C
Push button units and pilot light units Model(s) 3SB3, followed by 0, 1, 2, 3, 4, 5 or 6, followed by 00, 03 or 20, followed by 0A, 0B, 0C, 0D,
0E, 0J, 0K, 0H, 1A, 1C, 1F, 1G, 1H, 1L, 3A, 3C, 3F, 3M, 3P or 3S.
Pushbutton and pilot light units Model(s) 3SB2 followed by 0, 2, 3, 4 or 9 followed by 0, 1, 2, or 5 followed by a number 0 through 8.@
Pushbuttons, maintained Model(s) 3SB3, followed by 0, 1, 2, 3, 4, 5 or 6, followed by 00, 01, 02, 03, 04, 05, 06, 07, 08, 10, 11, 12, 13, 14,
15, 16, 17, 18, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 45, 46, 47, 50, 51, 53, 54 or 55,
followed by 0D, 1A, 1B, 1C, 1E, 1F, 1H, 1J, 1K, 1L, 1M, 1N, 1P, 1R, 1S, 1T, 1U, 1V, 1W, 1X or 1Y, followed by A0, A1, A2, A3, A4, A5, A6, A7,
A8, B0, B1, B2, B3, B4, B5, B6, B7, C0, C1, C2, C3, C4, C5, C6, C7, N6 or R2.
Pushbuttons, momentary illuminated Model(s) 3SB3, followed by 0, 1, 2, 3, 4, 5 or 6, followed by 01, 04, 05, 06, 07, 12, 13, 14, 15, 16, 18,
20, 21, 22, 24, 25, 26, 27, 28, 29, 30, 37, 38, 39, 40, 41, 42, 43, 45, 46, 47, 50, 51, 53, 54 or 55, followed by 0A, 0B, 0C, 0D, 1D, 1G, 1Q, 1S,
1V, 1W, 7S, 7V, 7W, 8B or 8D, followed by A0, A2, A3, A4, A5, A6, A7, A8, B0, B1, B3, B6, B7, C0, C1, C2, C3, C4, C5, C6 or C7.*
Pushbuttons, momentary non-illuminated Model(s) 3SB3, followed by 0, 1, 2, 3, 4, 5 or 6, followed by 00, 01, 02, 03, 08, 10, 11, 33, 34 or
35, followed by 0A, 0B, 0C, 1D, 1G, 1Q, 1S, 1V, 1W, 7A, 7B, 7C, 7S, 7V, 7W, 8A or 8C, followed by A1, A2, A3, A4, A5, A6, A7, A8, B0, B1, B2,
B3, B4, B5, B6, B7, C0, C1, C2, C3, C4, C5, C6, C7 or C8.
Relay interface modules Model(s) 3TX7004-1LB00, 3TX7004-1LB02, 3TX7004-1LF00, 3TX7014-1AM00, 3TX7014-1BB00, 3TX7014-1BB02,
3TX7014-1BE00, 3TX7014-1BE02, 3TX7014-1BF00, 3TX7014-1BF02, 3TX7014-1BM00, 3TX7014-1BM02, 3TX7015-1AM00, 3TX7015-1BB00,
3TX7015-1BB02, 3TX7015-1BE00, 3TX7015-1BE02, 3TX7015-1BF00, 3TX7015-1BF02, 3TX7015-1BM00, 3TX7015-1BM02
Remote reset thermal overload relays Model(s) 3RU1900-1A*, 3RU1900-1B*, 3RU1900-1C*, 3RU1900-2A*, 3RU2900-1A*, 3RU2900-1B*,
3RU2900-1C*, 3RU2900-2A*, 3RU5900-1A
Safety relays Model(s) 3TK28, followed by 20, 21, 22, 23, 24, 25, 26, 27, 28, 30, 34 or 35, followed by -1 or -2, followed by A, B or C, followed
by B2, B3, B4, J2, L2 or W3, followed by 0, 1, 2 or 4.
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?nam... UL_CSA_Zertifikate.pdf
07.11.2013
NKCR7.E44653 - Auxiliary Devices Certified for Canada Seite 5 von 6
Safety Relays Model(s) 3TK28, followed by 50, 51, 52, 53, 54, 56, 57 or 58, followed -1 or -2, followed by A, B or C, followed by B2, B3, B4, J2
or L2, followed by 0, 1, 2 or 3.*
Selector switches non-illuminated and keyed operator Model(s) 3SB3, followed by 0, 1, 2, 3, 4, 5 or 6, followed by 00, 01, 02, 03, 08, 10
or 11, followed by 2A, 2B, 2C, 2D, 2E, 2F, 2G, 2H, 2J, 2K, 2L, 2M, 2N, 2P, 2Q, 2R, 2S, 2T, 2U, 2V, 3P, 3Q, 3R, 3S, 3T, 3U, 3V, 3A, 3B, 3C, 3D,
3E, 3F, 3G, 4A, 4B, 4C, 4D, 4E, 4F, 4G, 4H, 4L, 4M, 4N, 4P, 4Q, 4R, 4S, 5A, 5B, 5C, 5D, 5E, 5F, 5G, 5L, 5M, 5N, 5P, 5Q, 5R or 5S, followed by
A1, A2, A3, A4, A5, A6, A7, B5, B6, B7, D0, D1, D2, D3, D4, D5, D6, E0, E1, E2, E3, E4, E5, E6, E7, F0, F1, F2, G0, G1, G2, G3, G4, G5, G6, H0,
H1, H2, H3, H4, H5, H6, J0, J1, J2, J3, J4, J5, J6, K0, K1, K2, K3, K4, K5, K6, L0, L1, L2, L3, L4, L5, L6, M0, M1, M2, M3, M4, M5, M6, N0, N1,
N2, N3, N4, N5 or N6.
Selector switches, illuminated operator Model(s) 3SB3, followed by 0, 1 or 5, followed by 01, followed by 2A, 2B, 2C, 2D, 2E, 2F, 2G, 2H, 2J,
2K, 2L, 2M, 2N, 2P, 2Q, 2R, 2S, 2T, 2U, 2V, 3P, 3Q, 3R, 3S, 3T, 3U or 3V, followed by A0, A2, A3, A4, A5, A6, A7, A8, B6 or B7.
Solid state coupling relays Model(s) 3RS18, followed by 00, followed by -1 or -2, followed by A thru H.*
Solid state overload relays Model(s) 3RB10, followed by 55, 56, 65 or 66, followed by -1 or -2, followed by F, G, K or L, followed by G0 or W0.
48, followed by A or B, followed by T, followed by A thru N, followed by 1 or 3, followed by S, followed by 00. (a)
958EB3SA (a), 958GB3SA (a), 958HB3SA (a), 958LDB3SA (a), 958LEB3SA (a), 958LFB3SA (a), 958LGB3SA (a), 958LHB3SA (a)
Solid state safety combinations Model(s) 3TK28, followed by 40, 41, 42 or 45, followed -1 or -2, followed by B, D, E, F, G or H, followed by
B4, followed by 0, 1, 2 or 4.*
Solid state thermal motor protectors Model(s) 3RN10, followed by 0, 1, 2 or 6, followed by 0, 1, 2 or 3, followed by -1 or -2, followed by A,
B, C, D, F or G , followed by B, C, G, M, K or W, followed by a number, followed by 0 or 1.
Solid state time relays Model(s) 3RP15, followed by 0, 1, 2, 3, 4, 5, 6, 7 or 8, followed by 0, 1, 2, 3, 4, 5, 6, 7 or 8, followed by -1 or -2,
followed by A, B, E, N, Q, R or S, followed by a character and a number, followed by any number or character, followed by any number or
character.
Summation current transformers Model(s) 3UL22011A, 3UL22011B, 3UL22012A, 3UL22012B, 3UL22013A, 3UL22013B, 3UL22014B,
3UL22015B, 3UL22021A, 3UL22021B, 3UL22022A, 3UL22022B, 3UL22023A, 3UL22023B, 3UL22024B, 3UL22025B, 3UL22031A, 3UL22031B,
3UL22032A, 3UL22032B, 3UL22033A, 3UL22033B, 3UL22034B, 3UL22035B
Synchronous timers Model(s) 7PR10, followed by 40, followed by 2 or 7, followed by A thru H, J thru N, P thru S or T, followed by 0 or 1,
followed by 0.
Temperature monitoring relays Model(s) 3RS10, 3RS11, 3RS14, 3RS15, 3RS20 or 3RS21, followed by 0, 1, 2, 3, 4 or 5, followed by a
number, followed by -1 or -2, followed by A thru H, followed by a character, followed by 0, 1, 2, 3, 4, 5, 6 or 8.*
Thermal overload relays Model(s) 3RU1126, followed by combination of 0, 1 or 4 and A thru K, followed by B or D, followed by 0 or 1.
3RU5116, followed by combination of 0 or 1 and A thru K, followed by B0 or C1, with connecting supports 3RU5916-3AA01.
3RU5126 followed by combination of 0, 1 or 4 and a letter A thru K, followed by B or D, followed by 0 or 1, with connecting supports 3RU5926-
3AA01.
Thermal overload relays Model(s) 3RU2126, followed by -1 or -4, followed by A, B, C, D, E, F, G, H, J, K, N or P, followed by B, C or J, followed
by 0 or 1.
Thermal overload relays, connecting supports Model(s) 3RU2916-3AA01, 3RU2916-3AC01, 3RU2926-3AA01, 3RU2926-3AC01, 3RU6916-
3AA01, 3RU6926-3AA01
Thermal overload relays, covers Model(s) 3RT2916-4EA13, 3RU2916-3BJ20, 3RU2916-3BJ21, 3RU2926-3BJ21, 3RV2908-0P, 3RV2928-4AA00
Time relays, open type Model(s) 7PV15, followed by 0, 1, 3, 4, 5 or 7, followed by 0, 1, 2, 3, 4, 5, 6, 7 or 8, followed by -1, followed by A or B,
followed by J30, N30, P30, Q30 or W30.*
Undervoltage tripping and shunt release units Model(s) 3RV19 or 3RV29, followed by 0, 1 or 2, followed by 2, followed by -1, -2 or -4,
followed by A, B, C or D, followed by B0, B4, F0, G6, M1, N0, N6, P0, Q0, S0, U0, V0 or V1.*
3TY, followed by 7, followed by 461, 481, 561 or 681, followed by 1 or 2, followed by A, B, E, F, G, K, L, N, P, Q, R, S, U, V, AA00, KA00 or
UA00.*
4S5309350-20
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?nam... UL_CSA_Zertifikate.pdf
07.11.2013
NKCR7.E44653 - Auxiliary Devices Certified for Canada Seite 6 von 6
Current monitoring relays, open type Model(s) 3RR2, followed by 1, 2 or 4, followed by 4, followed by 1 or 2, followed by -1 or -2, followed
by A or F, followed by A or W, followed by 3 or 4.*
Solid-state overload relays Model(s) 3RB3, followed by 0 or 1, followed by 1 or 2, followed by 3 or 6, followed by -1, -2 or -4, followed by R,
N, P, S, T, Q or V, followed by B or E, followed by 0.
Thermal overload relays Model(s) 3RU1116, followed by combination of 0 or 1 and A thru K, followed by B0, B1 or C1.
3RU2116, followed by combination of -0, -1 or -4 and A thru K followed by B, C or J, followed by 0, 1or 9, may be followed by numbers and/or
characters.
Three phase current measuring modules Model(s) 3UF76 followed by 0, followed by 0, followed by -1, followed by A, followed by B or U,
followed by 0, may be followed by suffix numbers and/or characters.
* - May be followed by a suffix of number(s) or/and letter(s) for manufacturers use or marketing difference only.
+ - Followed by a letter.
© 2013 UL LLC
When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment
database for additional information regarding this product's certification.
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up
Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-
misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with
permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the
following format: "© 2013 UL LLC".
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?nam... UL_CSA_Zertifikate.pdf
07.11.2013
PMArt.-N 580916SiemnsSignumtype3SBC-UL ScertE4653
NKCR7.E44653
Auxiliary Devices Certified for Canada
Page Bottom
SIEMENS AG E44653
I IA CE CP R&D-VI 4
WERNER-VON-SIEMENS-STRASSE 48
92220 AMBERG, GERMANY
Accessories Model(s) 3RP1901, 3RP1902, 3RP1903, 3SB19*, 3SB29*, 3SB39*, 3SX, followed by numbers., 3SY, followed by numbers.
Accessories, connection cables Model(s) 3RA27, followed by any numbers and or characters, ends with E02, E03 or E11.
Accessory devices, cable connector, plug, separate actuator, actuator head Model(s) 3SE5000, may be followed by letters and/or
numbers or 3SY.. or 3SX.
AS-I moduls for compact starters, open type Model(s) 3RA6970-3A, 3RA6970-3B, 3RA6970-3C, 3RA6970-3D, 3RA6970-3E, 3RA6970-3F
AS-Interface adaptors Model(s) 3SF1.*, 3SF2.*, 3SF3.*, 3SF5.*, 3SF54*, 3SF55*, 3SF59*, 3SF7*
AS-Interface Fail-Safe Monitors Model(s) 3RK1105, followed by -1A or -1B, followed by E or G, followed by 04, followed by -0CA0, -1CA0,
-2CA0, -3CA0 or -4CA0.
AS-interfaces Model(s) 3RG9, followed by 0, followed by 0, 1, 2, 3 or 4, followed by 0, 1, 4, 5 or 8, followed by 0, followed by AA, AB, AC, AD,
AE, AF, AG, AH, AJ, AK, SB or SC, followed by 00.
3RK1 or 3RK2, followed by 1, 2 or 4, followed by 0, followed by 0, 1, 2, 5, 7 or 8, followed by -0, -1, -2, -3 or -8, followed by A thru N or S,
followed by A thru U.*
3RV59 or 3RV69, followed by 0, 1 or 2, followed by 2, followed by -1, -2 or -4 followed by A, B, C or D, followed by B0, B4, F0, G6, M1, N0, N6,
P0, Q0, S0, U0, V0 or V1.*
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?nam... UL_CSA_Zertifikate.pdf
07.11.2013
NKCR7.E44653 - Auxiliary Devices Certified for Canada Seite 2 von 6
3TX44, followed by 01, 02, 04, 11, 12, 13, 20, 22, 31, 40, followed by 0, 1 or 2, followed by A, B or G.
Auxiliary contact blocks, open type Model(s) 3RA6911-1A, 3RA6911-2A, 3RA6912-1A, 3RA6912-2A, 3RA6913-1A, 3RA6913-2A
Auxiliary devices proximity switches , "BERO" Model(s) 3RG4, followed by 0 or 1, followed by 1, 2, 3 or 4, followed by 1, 2, 3 or 4, followed
by 0, 2, 3 or 6, followed by A or K, followed by A, B or D, followed by 00.
Auxiliary devices, position switch and as-interface accessories, cable connectors, plugs, plugs in shafts Model(s) 3SE5000*
Auxiliary devices, speed, level, fault current, voltage monitoring relays Model(s) 3UG4, followed by 5, 6 or 8, followed by 01, 11, 12, 13,
14, 15, 16, 17, 18, 21, 22, 24, 25, 31, 32, 33, 41 or 51, followed by -1 or -2, followed by A thru L, followed by A, N, L, P, Q, R, S or W, followed
by a letter and a number.*
Auxillary Device: Accessories Model(s) Types 3ZY12 and 3ZY13 followed by suffix letters and or numbers.
Auxillary Device: Open type Relay Modules Model(s) Type 3SK1 followed by 1 or 2, followed by 1, 2 or 3, followed by 0, 1, 2 or 3, followed 0,
1 or 2 followed by A, B or C followed by B0, J2, L2, B4, B3, W2, or W3 followed by 0, 1, 2, or 4, may be followed by suffix letters and/or
numbers.
Communication modules, open type Model(s) 3RA27, followed by 1, followed by 1 or 2 followed by -0, -1 or -2, followed by A, B, C or D,
followed by A, B or E, followed by 00 or 10.
Communications-capable electronic overload relays, basic units Model(s) 3UF50, followed by 01, 11, 21, 31, 41 or 51, followed by -3A or
-3B, followed by B, J or N, followed by 0 or 1.
Communications-capable electronic overload relays, expansion modules Model(s) 3UF5100-0AB, 3UF5100-0AJ, 3UF5100-0AN
Connecting supports Model(s) 3RU5136 followed by combination of 0, 1 or 4 and a letter A thru K, followed by B or D, followed by 0 or 1, with
connecting supports 3RU5936-3AA01.
3RU5146, followed by combination of 4 and a letter D thru M followed by B or D, followed by 0 or 1, with connecting supports 3RU5946-3AA01.
Connection supports, for Types 3UA58, 3UR58 or 3UW17 Model(s) 3UX1421, 3UX1421-0XA
Contact blocks, lamp holders and transformers Model(s) 3SB34, followed by 00, 02, 03, 11, 20 or 23, followed by 0A, 0B, 0C, 0D, 0E, 0F,
0G, 0H, 0J, 0K, 0L, 0M, 0N, 0P, 0Q, 1A, 1B, 1C, 1D, 1F, 1G, 1H, 1L, 1M, 1N, 1PA, 1PB, 1PC, 1PD, 1PE, 1QA, 1QB, 1QC, 1QD, 1QE, 1RA, 1RB,
1RC, 1RD, 1RE, 2A, 2D, 2F, 2G, 2H, 3A, 3C, 3F, 3M, 3P, 3S, 3U, 3W, 5A, 5B, 5C, 5D, 5E, 5F, 5G, 5H, 5J, 6A, 6B, 6C, 6D, 6H or 6K.
Converters Model(s) 3RS1706, 3RS1705 or 3RS1725, followed by -1 or -2, followed by F or K, followed by D, E or W, followed by 00.
Electronic overload relays Model(s) 3RB12, followed by 46, 53, 57 or 62, followed by 0F, 0K, 0L, 1E, 1P or 1Q, followed by B, G or M, followed
by 1, 2, 3 or 4, followed by 0 or 1.
Electronic timers Model(s) 3RP10 or 3RP20, followed by 00, 05, 20 or 25, followed by 1 or 2, followed by A or B, followed by P3, Q3 or W3,
followed by a number.
7PU1040, 7PU1140, 7PU1540, 7PU1640, 7PU2040, 7PU2540, 7PU2640, 7PU2643, 7PU3020, 7PU3040, 7PU3120, 7PU3140, 7PU3240, 7PU3243,
7PU3320, 7PU3340, 7PU3348, 7PU4020, 7PU4040, 7PU4120, 7PU4140, 7PU4220, 7PU4320, 7PU4340, 7PU4440, 7PU4520, 7PU4540, 7PU4620,
7PU4640, 7PU4720, 7PU5120, 7PU5220, 7PU5340, 7PU5720, 7PU6020, 7PU6040, 7PU6220, 7PU7020, 7PU7220, 7PU7243, 7PU8040, 7PU8043,
7PU8140, 7PU8143, 7PU8148, 7PU8340, 7PU8343, 7PU8348, 7PU8540, 7PU8543, 7PU8548, 7PU8640, 7PU8643, 7PU8648, 7PU8740, 7PU8748,
7PX1040, 7PX1540, 7PX7040, 7PX7140, 7PX7340, 7PX8220
Electronic timers with and/or auxiliary switches, open type Model(s) 3RA28, followed by 1, followed by 1, 2, 3, 4, 5 or 6 followed by -0, -1
or -2, followed by A, C, D, E or F, followed by W, followed by 1 or 2, followed by 0.
Electronic timers, open type Model(s) 3RT19, followed by 16 or 26, followed by -2C, -2D, -2F, -2G or -2L, followed by C, D, E, G, H, J, K or L,
followed by 0, 1, 2, 3 or 5, followed by 1.
EMC protective units Model(s) 3RT1916-1PA1, 3RT1916-1PA2, 3RT1916-1PA3, 3RT1916-1PB1, 3RT1916-1PB2, 3RT1916-1PB3, 3RT1916-
1PD1, 3RT1916-1PD2, 3RT1916-1PD3, 3RT2916-1PA1, 3RT2916-1PA2, 3RT2916-1PA3, 3RT2916-1PB1, 3RT2916-1PB2
Four to eight pole control relays, open type Model(s) 3RH2, followed by 1, 2, 3, 4 or 8, followed by 0, 1, 2, 3, 4, 5, 6, 7 or 8, followed by 0,
1, 2, 3, 4, 5, 6, 7 or 8, followed by -1, -2 or -4, followed by A, B, F, G, H, J, K, M, P, Q, V or W, followed by a character and a number.*
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?nam... UL_CSA_Zertifikate.pdf
07.11.2013
NKCR7.E44653 - Auxiliary Devices Certified for Canada Seite 3 von 6
3SE2 283 OGA 43, 3SE2 283 6GA 43, 3SE2283-0GA44, 3SE2283-6GA44, 3S32283-0GA53, 3SE2283-6GA53, 3SE2283-0GA54, 3SE2283-6GA54
3SE2283-0GA 44, 3SE2283-0GA 54, 3SE2283-6GA 44, 3SE2283-6GA 53, 3SE2283-6GA 54, SE2 283 6GA 43
3RK10, followed by 0, followed by 0, 1, 2, 3 or 4, followed by 0A, 0B, 0C, 0D, 0E, 0F or 0J, followed by A, B or C, followed by two numbers,
followed by one number, two characters and one number.
IO-link modules Model(s) 3RK50, followed by 1, followed by 0, followed by 0, followed by B or C, followed by A, followed by 0 or 1.*
Limit switches Model(s) 3SE2 or 3SE3, followed by 1, 3, 4 or 6, followed by 0, 2 or 7, followed by 0, 3, 4 or 6, followed by -0, -1, -3, -6, -7 or
-8, followed by A thru X, may be followed by W, X or V.*
3SE22, 3SE28, 3SE32 or 3SE38, followed by 00, 10, 20 or 30, followed by 0, 1, 3, 6, 7 or 8, followed by suffix letters A, AA, C, CV, D, DV, E, EV,
F, FV, G, GV, GW, GA, L, M, S, SV, R, RV, U, UW, V, VV, VW, W, WW, WV, XL, XT, XH, XX, may be followed by of letters and/or numbers up to
three digits for manufacturers use.
Limit switches Model(s) 3SE2 243-0XX, 3SE2 243-0XX18, 3SE2 243-0XX30, 3SE2 243-0XX38, 3SE2 243-0XX40, 3SE2 243-0XX48, 3SE2 243-
6XX40, 3SE2 243-6XX48, 3SE2 257-6XX, 3SE2 257-6XX18, 3SE2 257-6XX30, 3SE2 257-6XX38, 3SE2 257-6XX40, 3SE2 257-6XX48
Listed Accessories - Open type, current/voltage measuring modules Model(s) 6BK1700-3BA60-0AA0, 6BK1700-3BA70-0AA0, 6BK1700-
3BA80-0AA0
Listed Accessories - Open type,Current measuring modules Model(s) 6BK1700-3BA30-0AA0, 6BK1700-3BA40-0AA0, 6BK1700-3BA50-0AA0
Magnetically operated control switches Model(s) 3TH2, followed by 0, 1 or 2, followed by 22, 31, 40, 44, 53, 62, 71, 80, 81 or 82, followed
by 0, 1, 3, 4, 5 or 7, followed by A, B, D, E, F, G, H, J, K, L, P or Q
3TH80 or 3TH40, followed by 04, 13, 22, 31, 40, 92, 95 or 96, followed by 0A, 0B, 4B, 6B, 3B, 1E, 1F, 3K, 4K, 5K, 0H or OL.
3TH82 or 3TH42, followed by 44, 53, 62, 71, 74, 75, 80, 83, 84 or 93, followed by 0A, 0B, 3B, 4B, 6B, 1E, 1F, 3K, 4K, 5K, 0H or OL.*
3TH83 or 3TH43, followed by 10, 45, 46, 47, 48, 55, 64, 73, 82, 91 or 94, followed by 1H, 0A, 0B, 1E, 1F, 4B, 6B, 3B, 3K, 4K, 5K or 0H.
3TH85540A, 3TH85540B, 3TH85540H, 3TH85541E, 3TH85541F, 3TK2801OAC2, 3TK2801OAG2, 3TK2801OAN2, 3TK2801ODB4, 3TK2802OAC2,
3TK2802OAG2, 3TK2802OAN2, 3TK2802ODB4
Magnetically operated control switches, open type Model(s) 3TH40 or 3TH80, followed by 04, 13, 22, 31, 40, 92, 95 or 96, followed by OE,
OF, 3E, 3F, 1M, 2M, 3M, 4M, 5M or 6M.
3TH42 or 3TH82, followed by 44, 53, 62, 71, 74, 75, 80, 83, 84 or 93, followed by OE, OF, 3E, 3F, 1M, 2M, 3M, 4M, 5M or 6M.
3TH43 or 3TH83, followed by 10, 45, 46, 47, 48, 55, 64, 73, 82, 91 or 94, followed by OE, OF, 3E, 3F, 1M, 2M, 3M, 4M, 5M or 6M.
Modular systems (MSS) Model(s) 3RK3, followed by 11, 12, 13, 21, 22, 23, 24, 25, 31, 32 or 51, followed by 1 or 2, followed by 1 or 2,
followed by A or B, followed by A or C, followed by 0 or 1, followed by 0..*
Open type Industrial Control Equipment, stop modules, open type Model(s) 3SE6806-2CD00
Opening delay devices Model(s) 3RT1900-2HD810FB0, 3RT1900-2HD811FB0, 3TX4490-1A, 3TX4490-1H, 3TX4701-0AN1, 3TX4701-3AN1
Operator modules and accessories Model(s) 3RA2711-0EE11, 3RA6933-0A, 3RA6933-0B, 3RA6935-0A, 3RA6936-0A
Operators Model(s) 3SB3, followed by 0, 1, 2, 3, 4, 5 or 6, followed by 00, 01, 02, 03, 04, 05, 06, 07, 08, 10, 11, 12, 13, 14, 15, 16, 17, 18,
20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43 or 61, followed by 0A, 0B, 0C, 0D, 0E, 0N, 0P, 0Q,
1A, 1B, 1C, 1D, 1E, 1F, 1G, 1H, 1J, 1K, 1L, 1M, 1N, 1P, 1Q, 1R, 1S, 1T, 1U, 1V, 1W, 1X, 1Y, 2A, 2B, 2C, 2D, 2E, 2F, 2G, 2H, 2J, 2K, 2L, 2M, 2N,
2P, 2Q, 2R, 2S, 2T, 2U, 2V, 3P, 3Q, 3R, 3S, 3T, 3U, 3V, 3A, 3B, 3C, 3D, 3E, 3F, 3G, 3H, 4A, 4B, 4C, 4D, 4E, 4F, 4G, 4H, 4L, 4M, 4N, 4P, 4Q, 4R,
4S, 5A, 5B, 5C, 5D, 5E, 5F, 5G, 5L, 5M, 5N, 5P, 5Q, 5R, 5S, 6A, 6B, 6C, 7A, 7B, 7C, 7S, 7V, 7W, 8A, 8B, 8C, 8D, followed by A0, A1, A2, A3, A4,
A5, A6, A7, A8, B0, B1, B2, B3, B4, B5, B6, B7, C0, C1, C2, C3, C4, C5, C6, C7, C8, D0, D1, D2, D3, D4, D5, D6, E0, E1, E2, E3, E4, E5, E6, E7,
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?nam... UL_CSA_Zertifikate.pdf
07.11.2013
NKCR7.E44653 - Auxiliary Devices Certified for Canada Seite 4 von 6
F0, F1, F2, G0, G1, G2, G3, G4, G5, G6, H0, H1, H2, H3, H4, H5, H6, J0, J1, J2, J3, J4, J5, J6, K0, K1, K2, J2, K3, K4, K5, K6, L0, L1, L2, L3, L4,
L5, L6, M0, M1, M2, M3, M4, M5, M6, N0, N1, N2, N3, N4, N5, N6, P1 or R2.
Overload relays Model(s) 3RB2946-0EG, 3RB2946-0FH, 3RB2946-0MH, 3RB2956-0EG, 3RB2956-0FH, 3RB2956-0MH, 3RB2966-0EG, 3RB2966-
0FH, 3RB2966-0MH
Overload relays, accessories Model(s) 3RB2984*, 3RB2985*, 3RB2987*, 3UF7150-1AA0-0, 3UF7200-1AA00-0, 3UF7400-1AA00-0, 3UF7500-
1AA00-0, 3UF7700-1AA00-0, 3UF790-0AA00-0, 3UF7902-0AA00-0, 3UF7910-0AA00-0, 3UF7920-0AA00-0, 3UF7922-0AA00-0, 3UF793.-0.A00-0,
3UF7930-0AA00-0, 3UF7931-0AA00-0, 3UF7932-0AA00-0, 3UF7933-0AA00-0, 3UF7940-0AA00-0, 3UF7950-0AA00-0
Overload relays, basic units Model(s) 3RB22, 3RB23 or 3RB24, followed by 8, followed by 3, followed by -4A, followed by A or C, followed by
1.
Overload relays, current measuring modules Model(s) 3RB29, followed by 0, 4, 5 or 6, followed by 6, followed by -0 or -2, followed by B, D,
E, F, J, M, T or W, followed by G or H.*
Overload relays, current/voltage measuring module Model(s) 3RB29, followed by 46, 56 or 66, followed by -0EG, -0FH or -0MH.
Overload relays, digital modules and expansion modules Model(s) 3UF73, followed by 0, 1, 2 or 3, followed by 0 or 1, followed by -1A,
followed by B or U, followed by 0.*
Overload relays, open type, "Simicont System" Model(s) 3UA7, followed by 010, 011, 020 or 021, followed by 0 or 1, followed by A thru H, J
or K.
Overload relays, open type Model(s) 3UA50, 3UA52, 3UR50, 3UR52, 3UW10 or 3UW13 followed by 00, 01 or 40, followed by 0, 1, 2 or 7,
followed by A thru H, J, K or S.@
3UA54, 3UA55, 3UR54, 3UR55 or 3UW15, followed by 00, 01 or 40, followed by 0, 1, 2 or 8, followed by A, B, C, D, E, F, G, H, J, K, M, Q or R.*
3UA66002K, 3UA66003B, 3UA66003C, 3UA66003D, 3UA66003E, 3UA66402K, 3UA66403B, 3UA66403C, 3UA66403D, 3UA66403E, 3UA68003F,
3UA68003G, 3UA7900-0A, 3UA7900-0B, 3UA7900-0C, 3UA7901-0A
Overload relays, open type, with connection support 3UX1421, 3UX1421-0XA Model(s) 3UA58, 3UR58 or 3UW17, followed by 00, 01, 30
or 40, followed by 1, 2, 5 or 8, followed by A, B, C, D, E, F, G, T, P, U, V, Y or W.
Overspeed tripping devices Model(s) 3TK2810-0B41, 3TK2810-0B41-0AA0, 3TK2810-0B42, 3TK2810-0B42-0AA0, 3TK2810-0K41, 3TK2810-
0K41-0AA0, 3TK2810-0K42, 3TK2810-0K42-0AA0, 3TK2810-1B41-0AA0, 3TK2810-1B42-0AA0, 3TK2810-1BA41, 3TK2810-1K41, 3TK2810-
1K41-0AA0, 3TK2810-1K42, 3TK2810-1K42-0AA0, 3TK2810-1KA42
Pilot light units Model(s) 3SB1400-2A, 3SB1400-2B, 3SB1400-2C, 3SB1400-2D, 3SB1400-2E, 3SB1400-2L, 3SB1400-2P, 3SB1400-2Q,
3SB1420-2A, 3SB1420-3A, 3SB1420-3E, 3SB1430-2A, 3SB1430-3A, 3SB1430-3E
Pilot lights Model(s) 3SB3, followed by 0, 1, 2, 3, 4, 5 or 6, followed by 01, 04, 12, 17, 22, 23, 27, 36, 40, 44, 48, 52 or 61, followed by 6A, 6B
or 6C, followed by A0, A1, A2, A3, A4, A5, A6, A7, B6 or B7.
Push button unit and pilot light unit Model(s) 3SB3, followed by 0, 1, 2, 3, 4, 5 or 6, followed by 00, 03 or 20, followed by 1R, 1Q or 1P.
Push button units Model(s) 3SB14000A, 3SB14000B, 3SB14000C, 3SB14000G, 3SB14000H, 3SB14000J, 3SB14000R, 3SB14000S,
3SB14000V, 3SB14100B, 3SB14200B, 3SB14200C, 3SB14300B, 3SB14300C
Push button units and pilot light units Model(s) 3SB3, followed by 0, 1, 2, 3, 4, 5 or 6, followed by 00, 03 or 20, followed by 0A, 0B, 0C, 0D,
0E, 0J, 0K, 0H, 1A, 1C, 1F, 1G, 1H, 1L, 3A, 3C, 3F, 3M, 3P or 3S.
Pushbutton and pilot light units Model(s) 3SB2 followed by 0, 2, 3, 4 or 9 followed by 0, 1, 2, or 5 followed by a number 0 through 8.@
Pushbuttons, maintained Model(s) 3SB3, followed by 0, 1, 2, 3, 4, 5 or 6, followed by 00, 01, 02, 03, 04, 05, 06, 07, 08, 10, 11, 12, 13, 14,
15, 16, 17, 18, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 45, 46, 47, 50, 51, 53, 54 or 55,
followed by 0D, 1A, 1B, 1C, 1E, 1F, 1H, 1J, 1K, 1L, 1M, 1N, 1P, 1R, 1S, 1T, 1U, 1V, 1W, 1X or 1Y, followed by A0, A1, A2, A3, A4, A5, A6, A7,
A8, B0, B1, B2, B3, B4, B5, B6, B7, C0, C1, C2, C3, C4, C5, C6, C7, N6 or R2.
Pushbuttons, momentary illuminated Model(s) 3SB3, followed by 0, 1, 2, 3, 4, 5 or 6, followed by 01, 04, 05, 06, 07, 12, 13, 14, 15, 16, 18,
20, 21, 22, 24, 25, 26, 27, 28, 29, 30, 37, 38, 39, 40, 41, 42, 43, 45, 46, 47, 50, 51, 53, 54 or 55, followed by 0A, 0B, 0C, 0D, 1D, 1G, 1Q, 1S,
1V, 1W, 7S, 7V, 7W, 8B or 8D, followed by A0, A2, A3, A4, A5, A6, A7, A8, B0, B1, B3, B6, B7, C0, C1, C2, C3, C4, C5, C6 or C7.*
Pushbuttons, momentary non-illuminated Model(s) 3SB3, followed by 0, 1, 2, 3, 4, 5 or 6, followed by 00, 01, 02, 03, 08, 10, 11, 33, 34 or
35, followed by 0A, 0B, 0C, 1D, 1G, 1Q, 1S, 1V, 1W, 7A, 7B, 7C, 7S, 7V, 7W, 8A or 8C, followed by A1, A2, A3, A4, A5, A6, A7, A8, B0, B1, B2,
B3, B4, B5, B6, B7, C0, C1, C2, C3, C4, C5, C6, C7 or C8.
Relay interface modules Model(s) 3TX7004-1LB00, 3TX7004-1LB02, 3TX7004-1LF00, 3TX7014-1AM00, 3TX7014-1BB00, 3TX7014-1BB02,
3TX7014-1BE00, 3TX7014-1BE02, 3TX7014-1BF00, 3TX7014-1BF02, 3TX7014-1BM00, 3TX7014-1BM02, 3TX7015-1AM00, 3TX7015-1BB00,
3TX7015-1BB02, 3TX7015-1BE00, 3TX7015-1BE02, 3TX7015-1BF00, 3TX7015-1BF02, 3TX7015-1BM00, 3TX7015-1BM02
Remote reset thermal overload relays Model(s) 3RU1900-1A*, 3RU1900-1B*, 3RU1900-1C*, 3RU1900-2A*, 3RU2900-1A*, 3RU2900-1B*,
3RU2900-1C*, 3RU2900-2A*, 3RU5900-1A
Safety relays Model(s) 3TK28, followed by 20, 21, 22, 23, 24, 25, 26, 27, 28, 30, 34 or 35, followed by -1 or -2, followed by A, B or C, followed
by B2, B3, B4, J2, L2 or W3, followed by 0, 1, 2 or 4.
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?nam... UL_CSA_Zertifikate.pdf
07.11.2013
NKCR7.E44653 - Auxiliary Devices Certified for Canada Seite 5 von 6
Safety Relays Model(s) 3TK28, followed by 50, 51, 52, 53, 54, 56, 57 or 58, followed -1 or -2, followed by A, B or C, followed by B2, B3, B4, J2
or L2, followed by 0, 1, 2 or 3.*
Selector switches non-illuminated and keyed operator Model(s) 3SB3, followed by 0, 1, 2, 3, 4, 5 or 6, followed by 00, 01, 02, 03, 08, 10
or 11, followed by 2A, 2B, 2C, 2D, 2E, 2F, 2G, 2H, 2J, 2K, 2L, 2M, 2N, 2P, 2Q, 2R, 2S, 2T, 2U, 2V, 3P, 3Q, 3R, 3S, 3T, 3U, 3V, 3A, 3B, 3C, 3D,
3E, 3F, 3G, 4A, 4B, 4C, 4D, 4E, 4F, 4G, 4H, 4L, 4M, 4N, 4P, 4Q, 4R, 4S, 5A, 5B, 5C, 5D, 5E, 5F, 5G, 5L, 5M, 5N, 5P, 5Q, 5R or 5S, followed by
A1, A2, A3, A4, A5, A6, A7, B5, B6, B7, D0, D1, D2, D3, D4, D5, D6, E0, E1, E2, E3, E4, E5, E6, E7, F0, F1, F2, G0, G1, G2, G3, G4, G5, G6, H0,
H1, H2, H3, H4, H5, H6, J0, J1, J2, J3, J4, J5, J6, K0, K1, K2, K3, K4, K5, K6, L0, L1, L2, L3, L4, L5, L6, M0, M1, M2, M3, M4, M5, M6, N0, N1,
N2, N3, N4, N5 or N6.
Selector switches, illuminated operator Model(s) 3SB3, followed by 0, 1 or 5, followed by 01, followed by 2A, 2B, 2C, 2D, 2E, 2F, 2G, 2H, 2J,
2K, 2L, 2M, 2N, 2P, 2Q, 2R, 2S, 2T, 2U, 2V, 3P, 3Q, 3R, 3S, 3T, 3U or 3V, followed by A0, A2, A3, A4, A5, A6, A7, A8, B6 or B7.
Solid state coupling relays Model(s) 3RS18, followed by 00, followed by -1 or -2, followed by A thru H.*
Solid state overload relays Model(s) 3RB10, followed by 55, 56, 65 or 66, followed by -1 or -2, followed by F, G, K or L, followed by G0 or W0.
48, followed by A or B, followed by T, followed by A thru N, followed by 1 or 3, followed by S, followed by 00. (a)
958EB3SA (a), 958GB3SA (a), 958HB3SA (a), 958LDB3SA (a), 958LEB3SA (a), 958LFB3SA (a), 958LGB3SA (a), 958LHB3SA (a)
Solid state safety combinations Model(s) 3TK28, followed by 40, 41, 42 or 45, followed -1 or -2, followed by B, D, E, F, G or H, followed by
B4, followed by 0, 1, 2 or 4.*
Solid state thermal motor protectors Model(s) 3RN10, followed by 0, 1, 2 or 6, followed by 0, 1, 2 or 3, followed by -1 or -2, followed by A,
B, C, D, F or G , followed by B, C, G, M, K or W, followed by a number, followed by 0 or 1.
Solid state time relays Model(s) 3RP15, followed by 0, 1, 2, 3, 4, 5, 6, 7 or 8, followed by 0, 1, 2, 3, 4, 5, 6, 7 or 8, followed by -1 or -2,
followed by A, B, E, N, Q, R or S, followed by a character and a number, followed by any number or character, followed by any number or
character.
Summation current transformers Model(s) 3UL22011A, 3UL22011B, 3UL22012A, 3UL22012B, 3UL22013A, 3UL22013B, 3UL22014B,
3UL22015B, 3UL22021A, 3UL22021B, 3UL22022A, 3UL22022B, 3UL22023A, 3UL22023B, 3UL22024B, 3UL22025B, 3UL22031A, 3UL22031B,
3UL22032A, 3UL22032B, 3UL22033A, 3UL22033B, 3UL22034B, 3UL22035B
Synchronous timers Model(s) 7PR10, followed by 40, followed by 2 or 7, followed by A thru H, J thru N, P thru S or T, followed by 0 or 1,
followed by 0.
Temperature monitoring relays Model(s) 3RS10, 3RS11, 3RS14, 3RS15, 3RS20 or 3RS21, followed by 0, 1, 2, 3, 4 or 5, followed by a
number, followed by -1 or -2, followed by A thru H, followed by a character, followed by 0, 1, 2, 3, 4, 5, 6 or 8.*
Thermal overload relays Model(s) 3RU1126, followed by combination of 0, 1 or 4 and A thru K, followed by B or D, followed by 0 or 1.
3RU5116, followed by combination of 0 or 1 and A thru K, followed by B0 or C1, with connecting supports 3RU5916-3AA01.
3RU5126 followed by combination of 0, 1 or 4 and a letter A thru K, followed by B or D, followed by 0 or 1, with connecting supports 3RU5926-
3AA01.
Thermal overload relays Model(s) 3RU2126, followed by -1 or -4, followed by A, B, C, D, E, F, G, H, J, K, N or P, followed by B, C or J, followed
by 0 or 1.
Thermal overload relays, connecting supports Model(s) 3RU2916-3AA01, 3RU2916-3AC01, 3RU2926-3AA01, 3RU2926-3AC01, 3RU6916-
3AA01, 3RU6926-3AA01
Thermal overload relays, covers Model(s) 3RT2916-4EA13, 3RU2916-3BJ20, 3RU2916-3BJ21, 3RU2926-3BJ21, 3RV2908-0P, 3RV2928-4AA00
Time relays, open type Model(s) 7PV15, followed by 0, 1, 3, 4, 5 or 7, followed by 0, 1, 2, 3, 4, 5, 6, 7 or 8, followed by -1, followed by A or B,
followed by J30, N30, P30, Q30 or W30.*
Undervoltage tripping and shunt release units Model(s) 3RV19 or 3RV29, followed by 0, 1 or 2, followed by 2, followed by -1, -2 or -4,
followed by A, B, C or D, followed by B0, B4, F0, G6, M1, N0, N6, P0, Q0, S0, U0, V0 or V1.*
3TY, followed by 7, followed by 461, 481, 561 or 681, followed by 1 or 2, followed by A, B, E, F, G, K, L, N, P, Q, R, S, U, V, AA00, KA00 or
UA00.*
4S5309350-20
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?nam... UL_CSA_Zertifikate.pdf
07.11.2013
NKCR7.E44653 - Auxiliary Devices Certified for Canada Seite 6 von 6
Current monitoring relays, open type Model(s) 3RR2, followed by 1, 2 or 4, followed by 4, followed by 1 or 2, followed by -1 or -2, followed
by A or F, followed by A or W, followed by 3 or 4.*
Solid-state overload relays Model(s) 3RB3, followed by 0 or 1, followed by 1 or 2, followed by 3 or 6, followed by -1, -2 or -4, followed by R,
N, P, S, T, Q or V, followed by B or E, followed by 0.
Thermal overload relays Model(s) 3RU1116, followed by combination of 0 or 1 and A thru K, followed by B0, B1 or C1.
3RU2116, followed by combination of -0, -1 or -4 and A thru K followed by B, C or J, followed by 0, 1or 9, may be followed by numbers and/or
characters.
Three phase current measuring modules Model(s) 3UF76 followed by 0, followed by 0, followed by -1, followed by A, followed by B or U,
followed by 0, may be followed by suffix numbers and/or characters.
* - May be followed by a suffix of number(s) or/and letter(s) for manufacturers use or marketing difference only.
+ - Followed by a letter.
© 2013 UL LLC
When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment
database for additional information regarding this product's certification.
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up
Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-
misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with
permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the
following format: "© 2013 UL LLC".
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?nam... UL_CSA_Zertifikate.pdf