You are on page 1of 33

PayPal Name Lynn@butkus.

org
BOOSTERI MANUAL
OWNER'S
BEDIENUNGSANLEITUNG
MODED'EMPLOI
DEINSTRUCCIONES
MANUAL

Er-I
=rEt
o
@
o
@ o @
0 @
@ 0
@
o

www.butkus.us
Y o u r M i n o l t a B o o s t e rI I c o n n e c t st o t h e M i n o l t a A u t o M e t e r I I / I I V I I I F o r F l a s h M e t e r I I / I I I
t o g r e a t l y i n c r e a s et h e i r v e r s a t i l i t y f o r s p e c i a l i z e dm e t e r i n g f u n c t i o n s . l f a l s o i n c r e a s e st h e
s e n s i t i v i t y o f t h e F l a s h M e t e r I I I I I I . A t t a c h m e n t s i n c l u d e d w i t h t h e B o o s t e rI I e n a b l e p o s i t i v e ,
a c c u r a t e m e a s u r e m e n to f a c t u a l b r i g h t n e s sa t a n S L R e y e p i e c e ,o n a n S L R f o c u s i n g s c r e e no r
v i e w c a m e r a g r o u n d g l a s s t, h r o u g h t h e e y e p i e c e o f a m i c r o s c o p e o r t e l e s c o p e ,o r a t t h e f i l m
plane of a full-frame 35mm camera. The booster can also be used for conventionalreflected
l i g h t m e a s u r e m e n t so f 6 0 d e g r e e so r g r e a t e r .
Before using the Booster II for the first time, please read this manual carefully whil6
i n s t a l l i n gt h e b a t t e r y , h a n d l i n g a n d a c q u a i n t i n g y o u r s e l f w i t h t h e a t t a c h m e n t s a n d f e a t u r e s o f
y o u r b o o s t e r . I n t h i s w a y , y o u c a n g e t c o r r e c t r e a d i n g sa n d b e g i n t o r e a l i z ei t s p o t e n t i a l r i g h t
from the start.
CONTENTS
NAMESOFPARTS ,.....2 METERING THROUGH A MICROSCOPE 17
POWERSWITCH ...2 W i t h f u l l - f r a m e3 5 m m S L R a n d n o n - S L R
cameras
BATTERY ... 3 For Strobe
lnstallingbattery .......3
Checkingbattery .......3 CALIBRATION FOR LIGHTING CONDITlONS
BEYOND MAXIMUM BOOSTER
METERINGON VIEWCAMERA GROUND.
G L A S S O R S L R F O C U S I N G S C R E E N. . . . .
SENSITIVITY 21
4
Methodl ... 21
C a l i b r a t i o nf o r v i e w c a m e r a s 5
22
Calibrationfor SLR cameras
Metering
6
9
t':jt'':' 22
22
M E T E R ! N G T H R O U G H T H E E Y E P I E C EO F
SLRCAMERAS. ......10
"'***t*',::
Using a Microscope attachment
.' ,...' '
....
23
23
Cameras with manual stop4own C al i b r a t i o n 23
mechanism 10 Metering 24
Calibration 10 METERING AT THE FILM PLANE 25
Metering 13
l l l u m i n a t i o na t t h e f i l m p l a n e 25
Cameras without manua'l stop-down
E x p o s u r ea t t h e f i l m p l a n e 26
mechanism 14
Calibration 14 ORDINARY METERINGWITHOUT
Metering 16 ATTACHMENT 27
M E T E R I N GT H R O U G HA B E L L O W S . . . . . . 17 TECHNICAL DETAILS . 28
CARE AND STORAGE 27

www.butkus.us
i.:-,:ilg;;
NAMES OF PARTS POWER SWITCH

o C o m p e n s a t i o ns c a l e
F i l m p l a n e m e a s ur e me n t s e t t in g
T h e M i n o l t a B o o s t e r I I i s e q ui p p e d w i t h t w o
p o w e r s w i t c h e st o h e l p p r e v e n t b a t t e r y d r a i n .
@
o M a x i m u m - s e n s i t i v i t ys e t t i n g
O r d i n a r y r e f l e c t e d -ilg h t s e t t i n g
Power switch A activates the booster when
p r e s s e d ;t e n s e c o n d s l a t e r t h e b o o s t e r i s a u t o m a t i -
@
( n o a t t a c h m e n t su s e d ) cally turned off. This feature is particularlyuseful
o Power switch B w h e n m a k i n g o n l y o n e o r t w o m e a s ur e m e n t s .
@ B a t t e r y - c h a m b e rc o v e r When using power switch A, make sure powei
o Light receptor switch B is setto "OFF" t.
@ Receptor hood F o r c o n t i n u o u s m e a s u r e m e n to r w h e n m a k i n g -
o Attachment mou nting th read many measurements, slide power switch B to
@ Power switch A "ON". Be sure to slidethe switch back to "OFF"
o C o n n e c t i n gp l u g after use.
@ Spot-probeattachment
(D E y e p i e c ea t t a c h m e n t NOTE
(E M icroscope attachm ent W h e n u s i n g p o w e r s w i t c h A , b e s u r e t o p r e s si t
(D Film planeattachment for about one second or the power may not turn
on.
BATTERY
Installing battery Checking battery
1 . O p e n t h e b a t t e r y - c h a m b e rc o v e r b y s l i d i n g i t i n After confirming that the meter's battery is
t h e d i r e c t i o n o f t h e a r r o w . T h e c o v e rw i l l s p r i n g serviceable, plug the booster into the meter's
open. a c c e s s o r y - r e c e p t ojra c k . s e t t h e b o o s t e r ' s c o m p e n -
2 . I n s e r t a s i x - v o l t s i l v e r - o x i d e ( E v e r e a d yN o . 5 4 4 s a t i o n d i a l a t t h e o r d i n a r y r e f l e c t e d - l i g h ts e t t i n g
o r e q u i v a l e n t )o r a l k a l i n e - m a n g a n e s(eE v e r e a d y ( " L " ) . t u r n o n t h e b o o s t e r ' sp o w e r a n d p o i n t t h e
N o . 5 3 7 o r e q u i v a l e n t )b a t t e r y w i t h p l u s ( + ) light receptortoward a bright area.
and minus (-) ends positioned as indicated
i n s i d et h e c h a m b e r .C l o s et h e c o v e r . Auto Meter II
P r e s st h e m e t e r ' s m e a s u r i n g b u t t o n . l f t h e r e d
NOTE u n d e r - r a n g ew a r n i n g a r e a c a n n o t b e s e e n i n t h e
o lf the battery is not inserted correctly, the u n d e r - / o v e r - r a n g ew a r n i n g w i n d o w , t h e b a t t e r y i s
boosterwill not operate. s e r v i c e a b l e ;i f i t i s s e e n , r e p l a c e t h e b a t t e r y w i t h a
o Remove the battery if the booster is not to be freshone.
usedfor two weeks or more.
Auto Meter III/IIIF

mike
Digitally signed by mike
butkus (When using the Auto Meter IIIF, slide its
DN: cn=mike butkus,
o=orphancameras, ou=29, mode-selector switch to "AM B | ".) Press the

butkus
email=mike@butkus.org,
c=US meter's measuring button. lf an f-number appears
Date: 2017.10.17 21:51:50
-04'00' i n t h e d i s p l a y w i n d o w , t h e b a t t e r y i s s e r v i c e a b l ei;f
the letter "E" appears, replace the battery with a
f r e s ho n e .

www.butkus.us
M E T E R I N GO N V I E W € A M E R A G R O U N D .
G L A S S O R S L R F O C U S I N GS C R E E N
Flash Meter II When equipped with the spot-probe attach-
S e t t h e m e a s u r i n g - m o d es e l e c t o r o f t h e m e t e r ment, the Booster II enables the user of a view
so that "CORD" appearsin the mode indication camera or of an SLR camera with an accessible
w i n d o w . P r e s st h e m e t e r ' sm e a s u r i n gb u t t o n . l f t h e focusing screen to make precise reflected light
o v e r - r a n g ew a r n i n g l i g h t s o r a n u m b e r a p p e a r s i n r e a d i n g so f e l e c t r o n i c o r b u l b f l a s h o r o f c o n t i n u -
the f-number readout window, the battery is o u s i l l u m i n a t i o n b y m e a s u r i n gt h e l u m i n a n c e o h
s e r v i c e a b l e ;i f t h e u n d e r - r a n g ew a r n i n g c o m e s o n , t h e f o c u s i n g s c r e e n . B e c a u s et h e l i g h t r e a d i n g i s _ -
replace the battery with a fresh one. t a k e n a t t h e f i l m p l a n e w i t h v i e w c a m e r a s ,i t i s n o t - .
n e c e s s a r yt o m a k e e x p o s u r e c o r r e c t i o n sf o r b e l l o w s
Flash Metor III e x t e n s i o n w h e n t a k i n g c l o s e - u pp h o t o m a c r o g r a p h s .
S l i d e t h e m e a s u r i n g - m o d es e l e c t o r o f t h e m e t e r (For close-up readings with SLR cameras see
s o t h a t " C O R D " o r " A M B l " a p p e a r si n t h e d i s p l a y " M e t e r i n g t h r o u g h a b e l l o w s , "p . 1 7 . 1
w i n d o w . P r e s st h e m e t e r ' s r n e a s u r i n gb u t t o n . l f t h e Calibrationwith any of the four meters must be
over-rangesignal or an f-number appears in the done under continuous-light conditions. Even
d i s p l a y w i n d o w , t h e b a t t e r y i s s e r v i c e a b l e ;i f t h e w h e n y o u p l a n t o m e a s u r ee l e c t r o n i c o r b u l b f l a s h
u n d e r - r a n g ew a r n i n g a p p e a r s , r e p l a c e t h e b a t t e r y w i t h a f l a s h m e t e r , c o n t i n u o u s - l i g h tc a l i b r a t i o n
with a fresh one. must be completed fi rst.
Calibrating for view cameras
1 . Auto Meter II: Flash Meter II/III:
Set film speed and move the incident/ Note the measuringtime and f-number in
r e f l e c t e ds e l e c t o rt o " l N C . " t h e d i s p l a yw i n d o w .
AUIO MEtEr III: 6. Move the receptor hood back to its recessed
S e t f i l m s p e e d. position and screw the spot-probe attachment
Auto Meter IIIF: onto the BoosterII.
S l i d e m o d e - s e l e c t o rs w i t c h t o " A M B l " a n d 7. With the camera attached securely to a tripod,
set film speed. f o c u s a t i n f i n i t y a n d p o i n t t h e l e n sa t t h e s a m e
Flash Meter II: surface as in step 4.
S e t f i l m s p e e d a n d m o v e t h e m e a s ur i n g - 8. Set the lens aperture at t15.6, or if the lens'
- mode selector so that "COR D" appears in m a x i m u m a p e r t ur e i s s m a l l e r t h a n f 1 5 . 6 ,s e t t h e
t h e m o d e i n d i c a t i o nw i n d o w . m a x i m u m a p e r t ur e .
Flash Meter III: 9. U s i n g a f o c u s i n gc l o t h o r o t h e r s u i t a b l em a t e r i a l
Set the film speed and slidethe measuring t o s h i e l d t h e g r o u n d g l a s sf r o m s t r a y l i g h t , p l a c e
mode selector so "AM B l" appears in the the tip of the spot-probe attachment f lat
d i s p l a yw i n d o w . a g a i n s t t h e g r o u n d g l a s sa n d p u s h t h e m e t e r ' s
2 . Plug the booster into the meter's accessory- m e a s ur i n g b u t t o n .
receptorjack.
3 . Extend the booster's receptor hood as far as it
w i l l g o a n d t u r n t h e c o m p e n s a t i o nd i a l s o t h a t
t h e i n d e x i s o p p o s i t et h e " L " .
4. Turn on the booster's power and point its light
receptor toward an evenly illuminated surface
(such as a wall or l8-percent gray card). Press
t h e m e t e r ' s m e a s u r i n gb u t t o n .
5 . Auto Meter II/ilI/IIIF:
Note the exposure value or the shutter-
s p e e d/ f - n u m b e r c o m b i n a t i o n .
www.butkus.us
Calibration for SLR cameras

1 0 . T u r n t h e c o m p e n s a t i o nd i a l u n t i l t h e r e a d i n gi s CAUTION
t h e s a m ea s t h e o n e o b t a i n e d i n s t e p 5 . perform the calibration BEFORE loading film
Auto Meter II/III/IIIF: into your SLR camera.
Continue pressing the measuring button
w h i l e t u r n i n g t h e c o m p e n s a t i o nd i a l . 1. Auto Meter II:
FlashMeter II/III: Set film speed and move the incident/
P r e s st h e m e a s u r i n g b u t t o n e v e r y t i m e t h e r e f l e c t e ds e l e c t o rt o " l N C . "
compensation dial is moved to check each Auto Meter III:
new reading. )
Set fi lm speed.
Record the setting obtained on the booster's Auto Meter IIIF:
c o m p e n s a t i o nd i a l . S l i d e t h e m o d e - s e l e c t o rs w i t c h t o " A M B I "
speed'
NorE ,.":llr':llrm
o lf the reading obtained in step 5 cannot be Set film speed and move the measuring-
matched even with the booster'scompensation mode selector so that "CORD" appears in
d i a l s e t a t " H " , p l e a s er e f e r t o p . 2 1 . t h e m o d e i n d i c a t i o nw i n d o w .
o B e c a u s el i g h t t r a n s m i s s i o nt h r o u g h t h e g r o u n d - F l a s hM e t e r I I I :
g l a s sm a y n o t b e u n i f o r m a t d i f f e r e n t o o i n t s o n Set the film speed and slide the measuring
its surface, it is best to calibrate and .make mode selector so "AMBI" appears in the
readings at the same point when using the display window.
b o o s t e r w i t h t h e s p o t - p r o b ea t t a c h m e n t .
2. Plug the booster into the meter's accessory- 7 . Turn on the booster's power and press the
r e c e p t o rj a c k . m e t e r ' sm e a s u r i n gb u t t o n .
3 . Screw the film-plane attachment onto the Auto Meter II/II/IIIF:
b o o s t e r a n d m o v e t h e c o m p e n s a t i o nd i a l s o t h a t N o t e t h e e x p o s ur e v a l u e o r t h e s h u t t e r -
t h e i n d e x i s o p p o s i t et h e " C " . s p e e d / f - n u m b e cr o m b in a t io n .
4 . With the camera attached securely to a tripod, Flash Meter II/III:
f o c u s o n a n e v e n l y i l l u m i n a t e d s u r f a c e ( s u c ha s N o t e t h e m e a s ur i n g t i m e a n d t h e f - n u m b e r
a w a l l o r 1 8 - p e r c e n tg r a y c a r d ) . i n t h e d i s p l a yw i n d o w .
5 . Set the aperture ring of the lens to f/5.6 and 8. Remove the film-plane attachment from the
t h e c a m e r a ' s s h u t t e r - s p e e ds e l e c t o r t o " b u l b " . camera's film f rame aperture. U nscrew the
Open the shutter. a t t a c h m e n t c o u n t e r c l o c k w i s ef r o m t h e b o o s t e r .
A l o c k a b l e c a b l e r e { e a s e ,s u c h a s M i n o l t a ' s Close the shutter and the back cover of the
Cable Release II, can be used to hold the cam era.
shutteropen. 9 . Screw the spot-probe attachment onto the
6. Open the back cover of the camera. Fit the b o o s t e r . U s i n g a f o c u s i n gc l o t h o r o t h e r s u i t a b l e
r a i s e df r a m e g u i d e o f t h e f i l m - p l a n ea t t a c h m e n t material to shield the focusing screen from
i n t o t h e c a m e r a ' sf i l m - f r a m e a p e r t u r e a n d p r e s s stray light, place the tip of the spot-probe
lightly to hold it in place. attachment flat on the focusingscreen.

www.butkus.us
1 0 . Set the aperture ring of the lens to f/5.6 and NOTE
use the stopdown button or lever on the lens o lf the reading obtained in step 7 cannot be
or camera body to close down the lens dia- matched even with the booster's compensation
phragm. With the camera focused on the same d i a f s e t a t " H " , p l e a s er e f e r t o p . 2 1 .
surface under the same illumination as that l f t h e f o c u s i n gs c r e e no r l e n su s e d i n c a l i b r a t i n g
m e a s u r e di n s t e p 4 , p r e s st h e m e t e r ' s m e a s u r i n g the booster is changed, the booster must be
button. recalibrated using the applicable combinatiogt
1 1 . T u r n t h e c o m p e n s a t i o nd i a l u n t i l t h e r e a d i n gi s to obtain proper exposurereadings.
t h e s a m ea s t h e o n e o b t a i n e d i n s t e p 7 . B e c a u s el i g h t t r a n s m i s s i o nt h r o u g h t h e f o c u s i n g '
Auto Meter II/III/IIIF : s c r e e n / g r o u n d g l a s so r l e n s i n u s e m a y n o t b e '
C o n t i n u e p r e s s i n g t h e m e a s ur i n g b u t t o n the same from the center to the edges,spot-
w h i l e t u r n i n g t h e c o m p e n s a t i o nd i a l . p r o b e r e a d i n g s s h o u l d b e m a d e , i f p o s s i b l e ,a t
Flash Meter II/III: the same point at which the booster was
P r e s st h e m e a s u r i n g b u t t o n e v e r y t i m e t h e calibrated.
compensation dial is moved to check each
n e w r e a di n g .
Record the setting obtained on the booster's
c o m p e n s a t i o nd i a l .
Maering
T
T o m e a s u r e t h e l i g h t p a s s i n gt h r o u g h a v i e w - Auto Meter II:
camera groundglassor an SLR focusing screen, usingthe meter scales
proceed as follows: Auto Meter III/IIIF:
1. With the camera attached securely to a tripod, pressing the time increase/decreasebut-
focus on the subject and compose the picture. tons (with Auto Meter IIIF's mode-selec-
2. Set the lens aperture of the camera to f/5.6. lf tor switch at "AMBl")
the mdximum lens aperture of your view- Flash Meter II:
camera lens is smaller than f/5.6, set the using the indicated readings and the
maximum aperture. a p e r t u r e / s p e e dc o n v e r s i o nd i a l f o u n d o n
3 . F o r v i e w c a m e r a s ,m o v e t h e c o m p e n s a t i o n d i a l the back of the meter
so that the index is opposite the setting found F l a s hM e t e r I I I :
i n s t e p 1 0 o f t h e v i e w - c a m e r as e c t i o n . W h e n by changing the shutter speed with the
using an SLR, move the dial to the setting meter set to "AMBl" mode
f o u n d i n s t e p 1 1 o f t h e p r e c e d i n gs e c t i o n . For electronic/bulbflash measurements:
4. Plug the booster into the meter's accessory- a. Set the proper flash-sync speed on the
r e c e p t o rj a c k a n d t u r n o n i t s p o w e r . camera.
5 . U s i n g a f o c u s i n gc l o t h o r o t h e r s u i t a b l e m a t e r i a l A u t o M e t e r I I I F ( e l e c t r o n i cf l a s h o n l y ) :
to shield the groundglass or focusing screen Slide the meter's mode-selector switch to
from stray light, place the spot-probe attach- " F L A S H " ( e i t h e r1 / 6 0 o r 1 / 1 2 5 s e c . ) .
ment flat on an imagearea of the groundglass Flash Meter II/III:
or focusing screen you wish to.reproduce as a S e t t h e f l a s h - s y n cs p e e d a n d a p p l i c a b l e
m i d - t o n e . P r e s st h e m e t e r ' s m e a s u r i n g b u t t o n . mode (cord, non cord, or multi) on the
6 . F o r c o n t i n u o u sl i g h t : meter.
From the obtained meter reading, select a b. Test fire the flash and set the camera
convenientshutter speedand aperturecom- according to the meter readout.
bination.
www.butkus.us .l-:,ru,.*
'
M E T E R I N GT H R O U G H T H E E Y E P I E C EO F S L R C A M E R A S

F i t t e d w i t h t h e e y e p i e c ea t t a c h m e n t , t h e b o o s t e r c a n m a k e c e n t e r e d ,c i r c u l a r , t h r o u g h - t h e - l e n se x p o s u r e
r e a d i n g s t h r o u g h t h e e y e p i e c e o f a n S L R . T h i s i s e s p e c i a l l yu s e f u l f o r S L R c a m e r a sw i t h o u t b u i l t - i n T T L
l i g h t - m e t e r i n gs y s t e m s o r w h e n c o n n e c t e d t o t h e A u t o M e t e r I I I F o r F l a s h M e t e r I I o r I I I f o r T T L m e a s u r e -
ments of electronicor bulb flash.

Cameras with manual stop4own mechanism 1. Auto Meter II:


Set film speed and move the incideni/
Calibration r e f l e c t e d s e l e c t o rt o " l N C . " /
Calibration with any of the f ive metersmust be Auto Meter III:
d o n e u n d e r c o n t i n u o u s - l i g hct o n d i t i o n s .E v e n w h e n Set f ilm speed.
y o u p l a n t o m e a s u r ee l e c t r o n i co r b u l b f l a s h w i t h Auto Meter IIIF l
a f l a s h m e t e r , c o n t i n u o u s - l i g h ct a l i b r a t i o nm u s t b e S l i d e t h e m o d e - s e l e c t o rs w i t c h t o " A M B l "
completed first. and set f ilm speed.
Flash Meter II:
CAUTION Set film speed and move the measuring-
P e r f o r m t h e c a l i b r a t i o n B E F O R E l o a d i n gf i l m mode selector so that "CORD" appearsin
into your SLR camera. t h e m o d e i n d i c a t i o nw i n d o w .
F l a s hM e t e r I I I :
Set the film speed and slide the measuring
mode selector so "AMBI" appears in the
d i s p l a yw i n d o w .
2 . Plug the booster into the meter's accessory-
r e c e p t o rj a c k .
3 . Screw the f ilm-plane attachment onto the
booster and turn the compensationdial so that
the index is oppositethe "C".
,
4. With the cameraattached securely to a tripod, 7 . Turn on the booster's power and press the
f o i u s o n a n e v e n l y i l l u m i n a t e d s u r f a c e( s u c ha s m e t e r ' s m e a s u r i n gb u t t o n .
a w a l l o r 1 8 - p e r c e n tg r a y c a r d ) . Auto Meter II/ilI/IIIF:
5. Set the aperturering of the lensto f/5.6 (or if Note the exposure value or the shutter-
the lens' maximum aperture is smaller than s p e e d / f - n u m b e rc o m b i n a t i o n .
f15.6, set the maximum aperture). Set the Flash Meter II/III:
c a m e r a ' ss h u t t e r - s p e e ds e l e c t o r t o " b u l b " . o p e n N o t e t h e m e a s u r i n gt i m e a n d t h e f - n u m b e r
t h e s h u t t e r . A l o c k a b l e c a b l e r e l e a s e ,s u c h a s i n t h e d i s p l a yw i n d o w .
M i n o l t a ' s C a b l e R e l e a s eI I , c a n b e u s e d t o h o l d F o r c a m e r a sw i t h a l e n s t h a t h a s a m a x i m u m
the shutteropen. a p e r t u r es m a l l e rt h a n f 1 5 . 6 :
6. Open the back cover of the camera. Fit the Auto Meter II:
r a i s e df r a m e g u i d e o f t h e f i l m - p l a n ea t t a c h m e n t N o t e t h e s h u t t e r s p e e do p p o s i t e f / 5 . 6 .
i n t o t h e c a m e r a ' sf i l m - f r a m e a p e r t u r e a n d p r e s s Auto Meter III/IIIF; Flash Meter II/III:
l i g h t l yt o h o l d i t i n p l a c e . Change the shutter speed so that f 15.6
-
"';":ii'. appears in the display window. Note that
irult'
,i! \i;:. shutter speed.
8 . Remove the film-plane attachment from the
c a m e r a ' sf i l m a p e r t u r e . U n s c r e w t h e a t t a c h m e n t
counterclockwise from the booster. Close the
shutter and back cover of the camera.

www.butkus.us
9 . Screw the eyepiece attachment onto the 1 1 . T u r n t h e c o m p e n s a t i o nd i a l u n t i l t h e r e a d i n gi s
b o o s t e r a n d s l i d e i t o v e r t h e c a m e r a ' se y e p i e c e t h e s a m ea s t h e o n e o b t a i n e d i n s t e p 7 .
f rame.
1 0 . Set the aperture ring of the lensto f/5.6 (or to F o r c a m e r a sw i t h a l e n s t h a t h a s a m a x i m u m
the maximum aperture if smaller than f/5.6) a p e r t ur e s m a l l e rt h a n t 1 5. 6 :
and use the stop-down button or lever on the Auto Meter II:
lens or camera body to close down the lens T u r n t h e b o o s t e r ' s c o m p e n s a t i o nd i a l u n t i l
diaphragm. With the camera focused on the t h e s h u t t e r s p e e dn o t e d i n s t e p 7 i s o p p o s i t b
same surface under the same illumination as t h e l e n s 'm a x i m u m a p e r t u r e . /
t h a t m e a s ur e d i n s t e p 4 , p r e s s t h e m e t e r ' s Auto Meter III/IIIF; Flash Meter II/IIIi .
m e a s u r i n gb u t t o n . Set the shutter speed noted in step 7. Turn
the compensationdial until the f-number
equal to the lens' maximum aperture
a p p e a r si n t h e m e t e r ' sd i s p l a y w i n d o w .

Record the setting obtained on the booster's


c o m p e n s a t i o nd i a l .

NOTE
lf the reading obtained in step 7 cannot be
m a t c h e d e v e n w i t h t h e b o o s t e r ' sc o m p e n s a t i o n d i a l
s e t a t " H " , p l e a s er e f e r t o p . 2 1 .
Metering
1. With the camera attached securely to a tripod, F l a s hM e t e r I I :
focus on the subject and compose the picture. using the indicated readings and the
2. Set the lens aperture to 115.6 (or to the a p e r t u r e / s p e e dc o n v e r s i o n d i a l f o u n d o n
maximum aperture if smallerthan f/5.6). Use the back of the meter
the stop-down button or lever on the lens or Flash Meter III:
c a m e r a b o d y t o c l o s e d o w n t h e l e n sd i a p h r a g m . by changing the shutter speed with the
3. Screw the eyepiece attachment onto the meter set to "AMBI" mode
b o o s t e r a n d s l i d e i t o v e r t h e c a m e r a ' se y e p i e c e For electronic/bulb flash measurements:
frame. a. Set the proper flash-sync speed on the
4 . M o v e t h e c o m p e n s a t i o nd i a l s o t h a t t h e i n d e x i s camera.
opposite the setting found in step 11 of the A u t o M e t e r I I I F ( e l e c t r o n i cf l a s h o n l y ) :
p r e c e d i n gs e c t i o n . S l i d e t h e m e t e r ' s m o d e - s e l e c t o rs w i t c h t o
5. Plug the booster into the meter's accessory- " F L A S H " ( e i t h e r1 / 6 0 o r 1 / 2 5 0 s e c . ) .
receptor jack and turn on its power. Push the Flash Meter II/III:
m e t e r ' s m e a s ur i n g b u t t o n . Set the flash-syncspeed and applicable
6 . F o r c o n t i n u o u sl i g h t : mode (cord, non cord, or multi ) on the
From the obtained meter reading, select a meter.
convenient shutter speedand aperturecom- b. Test fire the flash and set the camera
bination. according to the meter readout.
Auto Meter II:
u s i n gt h e m e t e r s c a l e s
Auto Meter III/IIIF:
pressing the time increase/decreasebut-
tons (with Auto Meter IIIF's mode-selec-
tor switchat "AMBl")
www.butkus.us
Cameras without manual stop-down mechanism

Calibration F l a s hM e t e r I I I :
Calibrationwith any of the five metersmust be Set the film speed and slide the measuring
done under continuous-light conditions. Even mode selector so "AMBI" appears in the
w h e n y o u p l a n t o m e a s u r ee l e c t r o n i co r b u l b f l a s h d i s p l a yw i n d o w .
w i t h a f l a s h m e t e r , c o n t i n u o u s - l i g h tc a l i b r a t i o n 2. Plug the booster into the meter's accessory-
must be completed first. receptorjack.
3. Extend the booster's receptor hood as far as lt
CAUTION w i l l g o a n d m o v e t h e c o m p e n s a t i o nd i a l s o t h a t
Perform the calibration BEFORE loading film the index is opposite the "L".
into your SLR camera. 4. Point the booster's receptor toward an euenly'
illuminated surface (such as a wall or 18-
1. Auto Meter II: p e r c e n t g r a y c a r d ) . T u r n o n t h e b o o s t e r ' sp o w e r
Set film speed and move the incident/ a n d p r e s st h e m e t e r ' s m e a s u r i n gb u t t o n .
r e fl e c t e d s e l e c t o rt o " l N C . " 5. Auto Meter II/il/IIIF:
Auto Moter III: Note the exposure value or the shutter-
Set f ilm speed. s p e e d/ f - n u m b e r c o m b i n a t i o n .
Auto Meter IIIF: Flash Meter II/III:
S l i d e t h e m o d e - s e l e c t o rs w i t c h t o " A M B l " N o t e t h e m e a s u r i n gt i m e a n d t h e f - n u m b e r
and set film speed. i n t h e d i s p l a yw i n d o w .
Flash Meter II: 6. Move the receptor hood back to its recessed
Set film speed and move the measuring- position and screw the eyepiece attachment
mode selector so the "CORD" appears in onto the booster.
the mode indication window.
7. With the camerasecurelyattached to a tripod,
focus on the same surface under the same
i l l u m i n a t i o n a s t h a t m e a s u r e di n s t e p 4 .
8 . S l i d e t h e e y e p i e c ea t t a c h m e n t o v e r t h e c a m e r a ' s
e y e p i e c ef r a m e a n d p r e s st h e m e t e r ' s m e a s u r i n g
button.
9 . T u r n t h e c o m p e n s a t i o nd i a l u n t i l t h e r e a d i n gi s
t h e s a m ea s t h e o n e o b t a i n e d i n s t e p 5 .
Auto Meter II/ilI/IIIF:
Continue pressing the measuring button
w h i l e t u r n i n g t h e c o m p e n s a t i o nd i a| .
Flash Meter II/III:
P r e s st h e m e a s u r i n g b u t t o n e v e r y t i m e t h e
c o m p e n s a t i o nd i a l i s m o v e d .
Record the setting obtained on the booster's
c o m p e n s a t i o nd i a l .

NOTE
lf the lens used in calibrating the booster is
changed, the booster must be recalibrated to
obtain proper exposurereadings.

www.butkus.us
Metering
1 . W i t h t h e c a m e r a f a s t e n e ds e c u r e l y t o a t r i p o d , F l a s hM e t e r I I :
focus on the subject and compose the picture. using the indicated readings and the
2. Screw the eyepiece attachment onto the a p e r t u r e / s p e e dc o n v e r s i o n d i a l f o u n d o n
b o o s t e r a n d s l i d e i t o v e r t h e c a m e r a ' se y e p i e c e the back of the meter
f rame. F l a s hM e t e r I I I :
3 . M o v e t h e c o m p e n s a t i o nd i a l s o t h a t t h e i n d e x i s by changing the shutter speed with the
opposite the setting found in step 9 of the meter set to "AMBI" mode
p r e c e d i n gc a li b r a t i o n s e c t i o n . )
4. Plug the booster into the meter's accessory- For electronic/bulbf lashmeasurements:
receptor jack and turn on its power. Push the a. Set the proper flash-sync speed on the
m e t e r ' s m e a s u r i n gb u t t o n . camera.
5 . F o r c o n t i n u o u sl i g h t : A u t o M e t e r I I I F ( e l e c t r o n i cf l a s h o n l y ) :
From the obtained meter reading, select a S l i d e t h e m e t e r ' s m o d e - s e l e c t o rs w i t c h t o
convenient shutter speedand aperturecom- " F L A S H " ( e i t h e r1 / 6 0 o r 1 / 2 5 0 s e c . ) .
bination. Flash Meter II/III:
Auto Meter II: Set the flash-syncspeed and applicable
usingthe meter scales mode (cord, non cord, or multi) on the
Auto Meter III/IIIF: meter.
pressing the time increase/decreasebut- b. Test fire the flash and set the camera
tons (with Auto Meter IIIF's mode- a c c o r d i n gt o t h e m e t e r r e a d o u t .
s e l e c t o rs w i t c h a t " A M B l " )
M E T E R I N GT H R O U G H A B E L L O W S METERINGTHROUGH A MICROSCOPE
For more accurate metering when making
close-up photographs with a bellows and SLR
camera, it is best to calibrate the booster at each
centimeter graduation on the extensaon rail and
record the result in graph form to follow for
p reciseresults.

www.butkus.us
With full-frame 35mm SLR and non-SLR cameras
2 . Plug the booster into the meter's accessory-
Calibration receptorjack.
Calibration with any of the f ive metersmust be 3 . Screw the filmplane attachment onto the
done under continuous-light conditions. Even b o o s t e r a n d t u r n t h e c o m p e n s a t i o nd i a l s o t h a t
w h e n y o u p l a n t o m e a s u r ee l e c t r o n i c o r b u l b f l a s h t h e i n d e x i s o p p o s i t et h e " C " .
with a flash meter, continuous-light calibration 4 . With the camera and microscope adapter
must be completed f irst. securely attached to the microscope, place a
p i e c e o f t r a c i n g p a p e r o r s i m i l a r m a t e r i a lo n t h e
CAUTI ON s l i d e s t a g ea n d f o c u s o n i t .
P e r f o r m t h e c a l i b r a t i o n B E F O RE l o a d i n g f i l m 5 . Set the camera's shutter-speed selector to r-
into your SLR camera. /'
" b u l b " a n d o p e n t h e s h u t t e r . A l o c k a b l ec a b l e
1. A u t o M e t e r I I : r e l e a s e ,s u c h a s M i n o l t a ' s C a b l e R e l e a s eI I , c a n
Set film speed and move the incident/ b e u s e dt o h o l d t h e s h u t t e r o p e n .
r e f l e c t e ds e l e c t o rt o " l N C . " 6 . Open the back cover of the camera. Fit the
Auto Meter III: r a i s e df r a m e g u i d e o f t h e f i l m - p l a n ea t t a c h m e n t
S e t f i l m s p e e d. i n t o t h e c a m e r a ' sf i l m - f r a m e a p e r t u r e a n d p r e s s
AUIO MEtErIIIF: lightly to hold it in place.
S l i d e t h e m o d e - s e l e c t o rs w i t c h t o " A M B l "
and set f ilm speed.
Flash Meter II:
Set film speed and move the measuring-
mode selector so that "CORD" appears in
t h e m o d e i n d i c a t i o nw i n d o w .
Flash Meter III:
Set the film speedand slide the measuring
mode selector so "AMBI" appears in the
d i s p l a yw i n d o w .
7. Turn on the booster's power and press the 9. When using an SLR-type camera, screw the
m e t e r ' sm e a s u r i n gb u t t o n . e y e p i e c ea t t a c h m e n t o n t o t h e b o o s t e r a n d s l i d e
Auto Meter II/IUIIIF: it over the camera's eyepiece frame. With
N o t e t h e e x p o s ur e v a l u e o r t h e s h u t t e r - n o n - S L R c a m e r a s ,s c r e w t h e m i c r o s c o p ea t t a c h -
s p e e d / f - n u m b e rc o m b i n a t io n . ment onto the booster, remove the micro-
Flash Meter II/III: scope's ocular, and insert the attachment into
N o t e t h e m e a s u r i n gt i m e a n d t h e f - n u m b e r t h e m i c r o s c o p et u b e i n p l a c e o f i t .
i n t h e d i s p l a yw i n d o w .

0 . P r e s st h e m e t e r ' s m e a s u r i n gb u t t o n . A d j u s t t h e
c o m p e n s a t i o nd i a l u n t i l t h e i n d i c a t e dr e a d i n gi s
the same as the one obtained in step 7. Record
the settingobtained.

8. Remove the f ilm-plane attachment f rom the NOTE


c a m e r a ' sf i l m a p e r t u r e . U n s c r e w t h e a t t a c h m e n t lf the reading obtained in step 7 cannot be
counterclockwise from the booster. Close the m a t c h e d e v e n w i t h t h e b o o s t e r ' sc o m p e n s a t i o nd i a l
shutter and back cover of the camera. s e t a t " H " , p l e a s er e fe r t o p . 2 1 .

www.butkus.us
Metering FOR STROBE:
1 . l l l u m i n a t et h e s p e c i m e na n d f o c u s o n i t . Reduce the light output by placing tracing
2 . M o v e t h e c o m p e n s a t i o nd i a l s o t h a t t h e i n d e x i s p a p e r o r s i m i l a r s u b s t a n c eo v e r t h e f l a s h g u a r d
opposite the calibration value found in step 10 w i n d o w o r a d j u s t t h e f l a s h - t o - s u b j e c td i s t a n c e
i n t h e p r e c e d i n gs e c t i o n . until f /5.6 is indicated.
3. When using an SLR-type camera, screw the
e y e p i e c ea t t a c h m e n t o n t o t h e b o o s t e r a n d s li d e NOTE
it over the camera's eyepiece f rame. When B e c a u s ea r e a d i n g o f f / 5 . 6 i s b e l o w t h e F l a s h
m e t e r i n g f o r n o n - SL R c a m e r a s , s c r e w t h e Meter ll's measuring range for film speedsettingsz'
, microscopeattachment onto the booster. Then '
of ASA 500 or over, the booster must be adjusted
r e m o v e t h e m i c r o s c o p e ' so c u l a r a n d i n s e r t t h e t o y i e l d a n f - n u m b e r w i t h i n t h e m e t e r ' s r a n g ew h e n
attachment into the microscope tube in place using these film speeds. To do this, turn the
of it. compensation dial to the setting indicated in the
4. Turn on the booster's power and press the table for the film speed in use. Then turn the
m e t e r ' s m e a s u r i n gb u t t o n . m e a s u r i n g - t i m es e l e c t o ru n t i l t h e f - n u m b e r i n d i c a t -
Auto Meter II: e d f o r t h i s s e t t i n g a p p e a r si n t h e f - n u m b e r r e a d o u t
Set the camera's shutter .speed to the speed window. Set the camera's shutter to the speed
opposite f/5.6 on the meter'sdial. s h o w n i n t h e m e a s u r i n g - t i m ew i n d o w .
Auto Meter III/IIIF; Flash Meter II/III:
Adjust the measuring time until f/5.6 is
indicatedin the indicationdisplaywindow
and set the camera's shutter to the speed
s h o w n i n t h e m e a s u r i n g - t i m ei n d i c a t i o n .
C ALIBRATIO N F O R LI G H T IN G C ON D IT ION SB EY O N D MA X IMU M B OOS TE R
SENSITIVITY
lf, when calibrating the meter, the indicated reading obtained for the final calibration step does not
I
e q u a l t h e r e a d i n g a t t h e f i l m p l a n e , e v e n w h e n t h e c o m p e n s a t i o nd i a l i s s e t a t " H " , c a l i b r a t e t h e b o o s t e r b y
a d j u s t i n gt h e m e t e r ' s f i l m - s p e e ds e t t i n g a s f o l l o w s :

METHOD1
Auto Meter II Flash Meter II
Using the film-speed setting grips, turn the W i t h t h e m e a s u r i n g - t i m e( s h u t t e r s p e e d )s e l e c -
aperture scale so that the speed and aperture tor set at the speed used for metering at the
combination obtained when metering with the f i l m p l a n e , p u s h t h e m e a s u r i n gb u t t o n ( i f i n
film-plane attachment are opposite each other. "CORD" mode, keep the button pushed in).
Record this setting along with the indicated D e p r e s st h e f i l m - s p e e d s e l e c t o rr e l e a s eu n t i l t h e
film speed. i n d i c a t i o n i s t h e s a m e a s t h a t m e a s u r e da t t h e
Auto Meter III/IIIF f i l m p l a n e . R e c o r d t h e f i l m - s p e e da n d m e a s u r -
With the measuring time set at the speed used i ng-time selector setti ngs.
for metering at the film plane (and the Auto Flash Meter III
M e t e r I I I F ' s m o d e - s e l e c t o rs w i t c h a t " A M B l " ) , With the measuring-time selector set at the
push the ASA/exposure-time selector key to speedused for metering at the film plane, reset
indicate the ASA display and adjust the in- the film speedselectorand push the measuring
c r e a s eo r d e c r e a s ek e y u n t i l t h e i n d i c a t i o n i s t h e b u t t o n . l f n e c e s s a r y ,r e p e a t t h i s p r o c e s s u n t i l
s a m ea s t h a t m e a s u r e da t t h e f i l m p l a n e . t h e i n d i c a t i o n i s t h e s a m e a s t h a t m e a s u r e da t
the film olane.

-, www.butkus.us
"
ii,ls,i,lf..
METHOD 2
Using a spot-probe attachment
Calibration
1. Plug the booster into the meter's accessory- 5 . With the camera attached securely to a tripod,
receptor jack. focus at infinity and set the lens at its maxi-
2. Extend the booster's receptor hood as far as it mum aperture.
w i l l g o a n d t u r n t h e c o m p e n s a t i o nd i a l s o t h a t 6 . Move the receptor hood back to its recessed
the index is oppositethe "L". position and screw the spot-probe attachment
3. Turn on the booster'spower and point its light onto the booster.
receptor toward an evenly illuminated surface 7 . P l a c e t h e t i p o f t h e s p o t - p r o b e f l a t a g a i n s tt h e , '
(such as a wall or lSgercent gray card). Press g r o u n d g l a s s a n d p r e s s t h e m e t e r ' s m e a s u r i n g-
t h e m e t e r ' s m e a s u r i n gb u t t o n . button.
4 . N o t e t h e s h u t t e r s p e e dt h a t i s o p p o s i t e t h e l e n s ' 8 . Auto Meter II:
m a x i m u m a p e r t u r ea s f o l l o w s : Turn the booster's compensation dial until
Auto Meter lI: t h e s h u t t e r s p e e dn o t e d i n s t e p 4 i s o p p o s i t e
R e a d f r o m t h e s h u t t e r - s p e e ds c a l e . il5.6.
Auto Meter III/IIIF: Auto Meter III/IIIF; Flash Meter II/III:
With the meter set to the measuring mode Set the shutter speed noted in step 4. Turn
(and Auto Meter IIIF's mode-selector switch the booster's compensation dial until f/5.6
a t " A M B l " ) , p r e s st h e i n c r e a s e / d e c r e a skee y a p p e a r si n t h e m e t e r ' s d i s p l a y w i n d o w .
u n t i l t h e l e n s ' m a x i m u m a p e r t u r ea p p e a r si n
the display. Record the setting obtained on the booster's
Flash Meter II/III: c o m p e n s a t i o nd i a l .
M o v e t h e m e a s u r i n g - t i m es e l e c t o r u n t i l t h e
lens' maximum aperture appears in the
display.

t: ,',',';flddffiib;. '; t.1".


ft
Metering Using a ln ic roscope attach men t
1. Focus on the subject and set any desired 1 . Plug the booster into the meter's accessory-
apertu re. r e c e p t o rj a c k .
2. Screw the spot-probe attachment onto the 2. Screw the film-plane attachment onto the
booster. booster and turn the compensationdial so that
3. Plug the booster into the meter's accessory- the index is opposite the "C".
r e c e p t o rj a c k a n d t u r n o n i t s p o w e r . 3. With the c€rmera and microscope adapter
4 . P l a c e t h e s p o t - p r o b ea t t a c h m e n t f l a t a g a i n s tt h e securely attached to the microscope, place a
groundglass. piece of tracing paper or similar material on the
P r e s st h e m e t e r ' s m e a s u r i n gb u t t o n . s l i d e s t a g ea n d f o c u s o n i t .
5 . N o t e t h e s h u t t e r s p e e do p p o s i t e f / 5 . 6 : 4. Set the camera's shutter-speed selector to
Auto Meter II: "bulb" and open the shutter. A lockable cable
Read from the shutter-speedscale. r e l e a s e ,s u c h a s M i n o l t a ' s C a b l e R e l e a s e[ I , c a n
Auto Meter III/IIIF: be usedto hold the shutter open.
W i t h t h e m e t e r s e t t o t h e m e a s u r i n gm o d e , 5. Open the back cover of. the camera. Fit the
press the increase/decrease key until f/5.6 raisedframe guide of the film-plane attachment
a p p e a r si n t h e d i s p l a y . i n t o t h e c a m e r a ' sf i l m - f r a m e a p e r t u r e a n d p r e s s
Flash Meter II/III: lightly to hold it in place.
M o v e t h e m e a s u r i n g - t i m es e l e c t o r u n t i l f / 5 . 6 6. Turn on the booster's power and press the
a p p e a r si n t h e d i s p l a y . m e t e r ' s m e a s u r i n gb u t t o n .
6. Take the photograph using the shutter speed
determined in step 5.

.-***rsi- www.butkus.us
7 . N o t e t h e s h u t t e r s p e e do p p o s i t e f / 5 . 6 : 1 0 . S e t t h e c o m p e n s a t i o n d i a l t o " H " a n d p r e s st h e
Auto Meter II: m e t e r ' s m e a s u r i n gb u t t o n .
Read from the shutter-speedscale. 1 ' , t .N o t e t h e f - n u m b e r o p p o s i t e t h e s h u t t e r s p e e d
Auto Meter III/IIIF: found in step 7:
W i t h t h e m e t e r s e t t o t h e m e a s u r i n gm o d e , Auto Meter II:
p r e s s t h e i n c r e a s e / d e c r e a s ek e y u n t i l f / 5 . 6 R e a d f r o m t h e m e a s u r i n gd i a l .
a p p e a r si n t h e d i s p l a y . Auto Meter III/IIIF; Flash Meter II/III:
Flash Meter II/III: S e t t h e s h u t t e r s p e e df o u n d i n s t e p 7 o n t h e
M o v e t h e m e a s u r i n g - t i m es e l e c t o r u n t i l f / 5 . 6 m e t e r a n d n o t e t h e f - n u m b e r t h a t a p p e a r si n
a p p e a r si n t h e d i s p l a y . the display.
8. Remove the film-plane attachment from the
c a m e r a ' sf i l m a p e r t u r e . U n s c r e w t h e a t t a c h m e n t
counterclockwise from the booster. Close the
shutter and back cover of the camera.
9. 35mm SLR: Screw the eyepiece attachment
onto the booster and slide it over the camera's
e y e p i e c ef r a m e .
N o n - S L R 3 5 m m : S c r e w t h e m i c r o s c o p ea t t a c h -
ment onto the booster. Remove the micro-
scope's ocular and insert the attachment into
t h e m i c r o s c o p et u b e i n p l a c e o f i t .

.
M E T E R I N GA T T H E F I L M P L A N E
Metering lllumination at the film plane
1 . l l l u m i n a t et h e s p e c i m e na n d f o c u s o n i t . 1. With the cameraattached securelyto a tripod,
2. With the compensationdial still set to "H", focus on the subject and compose the picture.
p r e s st h e m e t e r ' s m e a s u r i n gb u t t o n . 2 . S e t t h e f i l m - s p e e ds e l e c t o ro f t h e m e t e r t o A S A
3. Note the shutter speed opposite the f-number 100.
f o u n d i n s t e p 1 1 o f t h e p r e c e d i n gs e c t i o n : 3. Plug the booster into the meter's accessory-
Auto Meter II: r e c e p t o rj a c k .
R e a d f r o m t h e m e a s u r i n gd i a l . 4. Screw the f ilm-plane attachment onto the
Auto Meter III/IIIF : booster and turn the compensationdial so that
W i t h t h e m e t e r s e t t o t h e m e a s u r i n gm o d e , the index is opposite the "C".
p r e s s t h e i n c r e a s e / d e c r e a s ek e y u n t i l t h e 5. Set the camera's shutter-speed selector to
f - n u m b e r f o u n d i n s t e p 1 1 a p p e a r si n t h e "bulb" and open the shutter. A lockable cable
d isplay. r e l e a s e ,s u c h a s M i n o l t a ' s C a b l e R e l e a s eI I , c a n
Flash Meter II/III: be usedto hold the shutter open.
M o v e t h e m e a s u r i n g - t i m es e l e c t o r u n t i l t h e 6. Open the back cover of the camera. Fit the
f - n u m b e r f o u n d i n s t e p 1 1 a p p e a r si n t h e raisedframe guide of the film-placeattachment
d isplay. i n t o t h e c a m e r a ' sf i l m - f r a m e a p e r t u r e a n d p r e s s
4. Take the photograph using the shutter speed lightly to hold it in place.
determined in step 3.

www.butkus.us
i
l Exposure at the film plane
1 i
7. Turn on the booster's power and press the Proper exposure at the film plane is found by
j m e t e r ' s m e a s u r i n gb u t t o n . m u l t i p l y i n g t h e m e t e r ' s i n d i c a t e d s h u t t e r s p e e db y
Auto Meter II/IUIIIF: t h e i l l u m i n a t i o na t t h e f i l m p l a n e ( a sf o u n d i n t h e
'\
1
Note the exposure value or the shutter- p r e c e d i n gs e c t i o n )u s i n gt h e f o l l o w i n g f o r m u l a :
1
i s p e e d/ f - n u m b e r c o m b i n a t i o n .
I Flash Meter II/III: E=lT
I Note the measuringtime and the f-number
l
j
I i n t h e d i s p l a yw i n d o w . W h e r e E = e x p o s u r e i n l u x - s e c o n d s ,| = i l l u m i n a - "
I
j 8. The filmplane illumination is found by t i o n a t t h e f i l m p l a n e i n l u c e s ,a n d T = t h e s h u t t e r
II substituting the shutter speed found in step 7 s p e e di n s e c o n d s .
i for "T" in the followingformula:
I
i
I
I r =44(zn)
T
I
i
I Where | = the illuminationon the film surface
i

i n l u c e s ,T = t h e s h u t t e r s p e e d i n s e c o n d s ,a n d n
I

I
I
I
= the difference in stops between the f-number
I
i i n d i c a t e db y t h e m e t e r a n d f / 5 . 6 .
i
) Example:
i With a shutter speed of 1/60 sec. and an
I
il
i n d i c a t e da p e r t u r e o f t 1 1 1 , w o r k t h e e q u a t i o n
l asfollows:
j
x 2n=4
il 0.1
I | =1^o xa
I

.tr =24

rx:- -.
O RDINA RY M E T E RI N G WIT H O U T A T T AC H ME N TS

The booster may also be used as a conventional 4. Turn on the booster's power and point its light
r e f l e c t e d - l i g h tm e t e r a n d i s p a r t i c u l a r l y u s e f u l f o r receptor toward the subject. Press the meter's
t a k i n g r e a d i n g so f s m a l l o b j e c t s w h e r e i t m a y b e m e a s u r i n gb u t t o n .
d i f f i c u l t o r i m p o s s i b l et o m e t e r i n t h e n o r m a l w a y . 5 . AutO M€tEr II:
1. Auto Meter II: Release the measuring button when the
Set film speed and move the incident/ shutter-speed scale stops moving and set the
r e f l e c t e ds e l e c t o rt o " l N C . " camera for any desired shutter speed and
Auto Meter III: aperture combination shown on the meter's
Set film speed. dial.
Auto Meter IIIF: Auto Meter III/IIIF; Flash Meter II/III:
S l i d e t h e m o d e - s e l e c t o rs w i t c h t o " A M B l " Set the camera's shutter speed to the speed
and setfilm speed. shown in the meter's measurn i g time-
Flash Meter II: indication window. Then adjust the lens
Set film speed and move the measuring- aperture to the f-number indicated in the
mode selectorso that "CORD" appears in display window.
the mode indication window.
Flash Meter III:
Set the film speed and slide the measuring
mode selector so "AMBI" appears in the
d i s p l a yw i n d o w .
2 . Plug the booster into the meter's accessory-
r e c e p t o rj a c k .
3 . Extend the booster's receptor hood as far as it
will go and turn the compensationdial so that
the index is opposite the "L".

.i.l;,;xi;; www.butkus.us ,'-


TECHNI CA L DE T A IL S
T y p e : H i g h - s e n s i t i v i t y l i g h t r e c e p t o r f o r t h r o u g h - t h e - l e n sl i g h t m e a s u r e m e n t w i t h M i n o l t a ' s A u t o M e t e r
U/II/IIIF and FlashMeter II/III
Detector: Silicon photocell
R e a d i n gm e t h o d s :
O n t h e f o c u s i n g s c r e e nw i t h S p o t - p r o b e a t t a c h m e n t
T h r o u g h a n S L R v i e w f i n d e r e y e p i e c ew i t h E y e p i e c ea t t a c h m e n t
A t t h e f i l m p l a n e o f a f u l l - f r a m e 3 5 m m c a m e r a w i t h F i l m - p l a n ea t t a c h m e n t
T h r o u g h a m i c r o s c o p ee y e p i e c ew i t h M i c r o s c o p ea t t a c h m e n t
W i t h o u t a t t a c h m e n t sa n d w i t h h o o d e x t e n d e d f o r n o r m a l r e f l e c t e d r e a d i n g o f 6 0 o u'
M e a s u r i n gr a n g e s : A u t o M e t e r I I I / I I : 0.001 to 2O,OOO luces (equiv.EV -7 to17 at ASA/ISO 1OO)
Auto MeterIIIF: AMBI: 0 . 0 0 1 t o 2 0 , 0 0 0 l u c e s ( e q u i v .E V - 7 t o 1 7 a t A S A / I S O
10 0 )
FLASH: 0.002 to 145 lux. sec.(equiv. EV -6.3 to 10 at ASA/ISO
100)
F l a s hM e t e r I I I : On CORD, NON. C, or MULTI: 0.002 to 145 lux. sec
( e q u i v .E V - 6 . 3 t o 1 0 a t A S A / l S O 1 0 0 )
on AMB | : 0.002 to 20,000 luces
( e q u i v .E V - 6 . 3 t o 1 7 a t A S A / l S O 1 0 0 )
F l a s hM e t e r I I : 0.007 to 145 lux. sec
( e q u i v .E V - 4 . 3 t o 1 0 a t A S A / l S O 1 0 0 )
O t h e r : A l t e r n a t e p u s h - b u t t o n a n d s l i d e - t y p e p o w e r s w i t c h e s ,a t t a c h i n g c o r d w i t h p l u g
Power source: One silver-oxidecell (4SR44), Eveready No.544 or equivalent; or alkaline-manganese cell
( 4 L R 4 4 ) , E v e r e a d yN o . 5 3 7 o r e q u i v a l e n t

. '..:
D i m e n s i o n s z2 5 x 3 7 x 1 1 3 m m ( x 1 - 7 1 1 6x 4 - 7 1 1 6i n . l
Weight:95S (3-3/8 oz.) without power cell or attachment
Accessories included: Spot-probe attachment, Eyepiece attachment, Microscope attachment, Film-plane
attachment

S p e c i f i c a t i o n ss u b j e c t t o c h a n g ew i t h o u t n o t i c e

C A RE AN D S T O RA G E

o D o n o t t o u c h t h e r e c e p t o r . l f i t b e c o m e ss o il e d , o Keep the power switch at "OFF" when the


remove loose matter with a blower brush, then booster is not use. lf it is not to be used for
wipe gently with a soft cleancloth. more than a month, be sure to remove the
o Do not subject your Minolta Booster II to battery.
vibration or shocks. o When the Booster II is to be stored for a long
r Do not support the booster up by the attach- time, it should ideally be placed in its original
ment cord, as damagemay be done to the wire package and sealed in an air-tight container
or connections. with an appropriate quantity of dehumidifying
r The unit should never be placed or left in the a g e n ts u c h a s s i l i c ag e l .
glove compartment or other places in motor
vehicles or elesewhere in which it may be
subject to relatively high tempertures. Further,
d o n o t s t o r e i t i n h u m i d p l a c e so r n e a r c o r r o s i v e
c h e mi c a l s .

www.butkus.us