You are on page 1of 4

REGULATION CHECK GENERAL SUMMARY

GENERAL CONDITION

NO ITEM CURRENT CONDTION EXTENSION AREA NEW CONDITION REMARK

BUILDING FOOTPRINT AREA


1 5,012m2 - 5,012m2
(m2)
2 BUILDING HEIGHT (m) 8,3m 6,6m 14,9m

3 NUMBER OF FLOOR 3 stories 2 stories 5 stories

4 BUILDING PERIMETER (m) 332m - 332m

5 VOLUME (m3) 41,600m3 33,078m3 74,678m3

REGULATION CHEK

ITEM CHECK AND CALCULATION AEON LONG BIEN


ITEM REGULATION COMMENT REMARK
METHOD CONDITION

Item 1.4.8 QCVN06-2022

FF HEIGHT < 15m 14,9m FF Truck parking and


FIRE FIGHTING - NO FF Truck Parking Elevated access
TRUCK ACCESS - NO FF Elevated Access not requirement

FIRE FIGHTING
REGULATION
1 FF TRUCK ROAD LENGTH FF TRUCK ROAD LENGTH
QCVN 06-2022
= 1/4 Building perimeter
Item 6.2.2.4 - Table 16 (Parking tower have ~80m Comply with Regulation
QCVN 06:2022 Sprinkler system protection)

FIRE FIGHTING
TRUCK ROAD FF TRUCK ROAD WxH
Item 6.2.1.1 QCVN06-2022 FF TRUCK ROAD WIDTH
Item 6.2.2.2 QCVN06-2022 ≥ 3,5m
FF TRUCK ROAD HEIGHT Comply with Regulation
CLEARANCE
≥ 4,5m

AEON MALL LONG BIEN RENOVATION WORK 0


REGULATION CHECK GENERAL SUMMARY
REGULATION CHEK

ITEM CHECK AND CALCULATION AEON LONG BIEN


ITEM REGULATION COMMENT REMARK
METHOD CONDITION

Layout fire fighting control


FIRE FIGHTING FIRE FIGHTING
Item 6.17.2 room inside the parking
REGULATION 2 CONTROL Checking drawing
QCVN 06-2022 building
QCVN 06-2022 ROOM
Min area = 6m2

PARKING
All walls nex to other
BUILDING NEXT Item2.2.1.5
1 buildings separate by Fire Checking drawing
TO OTHER QCVN 13-2018
CAR PARKING fighting wall Grade 1
BUILDINGS
REGULATION
QCVN 13-2018

FIRE Fire compartment max area


2 Item2.2.4 – Table 6 5,012m2 Comply with Regulation
COMPARTMENT = 5,200m2
QCVN 13-2018

AEON MALL LONG BIEN RENOVATION WORK 1


REGULATION CHECK AEON MALL LONG BIEN – PARKING TOWER EXTENSION

PARKING BUILDING

6,5m

PARKING BUILDING
Site Area: 5,012m2 KEY PLAN
Perimeter: 332m 10m 80m ~ 1/4
Building Height: 14.9m BUILDING
PERIMETER

Fire fighting wall


GRADE 1 Requirement

LEGEND

: FIRE FIGHTING WALL CLASS 1 (REI150)

: FIRE FIGHTING CONTROL ROOM

MALL BUILDING : LINKWAY

: FF TRUCK OPERATING PROPOSE

: FIRE TRUCK ROUTE

: FIRE TRUCK IN

: FIRE TRUCK OUT

CONCLUSION:
CONCLUSION:
1.1.FOLLOW
FOLLOWQCVN
QCVN03:2018
03:2018- -ARTICLE
ARTICLE2.2.1.5
2.2.1.5
THETHEWALL
WALLOPPOSITE
OPPOSITETHE
THEMALL
MALLBUILDING
BUILDINGBY BYTHE
THEFIRE
FIREFIGHTING
FIGHTINGWALL
WALLCLASS
CLASS11(REI
(REI150)
150)
2.2.THE
THELENGTH
LENGTHOFOFFF
FFTRUCK
TRUCKPARKING
PARKING==1/4
1/4BUILDING
BUILDINGPERIMETER
PERIMETER(~80M),
(~80M),DISTANCE
DISTANCEFROM
FROMFFFFTRUCK
TRUCKTO TOPARKING
PARKINGBUILDING
BUILDINGNOT
NOTUNDER
UNDER2M
2MAND
ANDOVER
OVER10M
10M(QCVN
(QCVN06:2022,
06:2022,ARTICLE
ARTICLE6.2.3)
6.2.3)
 FFFFTRUCK
TRUCKPARKING
PARKINGLOCATION
LOCATIONAT ATTHE
THELOCATION
LOCATIONPROPOSED
PROPOSED
3.3.THE
THEPARKING
PARKINGBUILDING
BUILDINGHAVE
HAVETOTAL
TOTALFLOOR
FLOORAREA
AREA25,060m2
25,060m2>>18,000
18,000m2,
m2,FOLLOW
FOLLOWQCVN
QCVN06:2022
06:2022- -ARTICLE
ARTICLE6.17.2
6.17.2
 NEED
NEEDTOTOLAYOUT
LAYOUTFIRE
FIREFIGHTING
FIGHTINGCONTROL
CONTROLROOM
ROOMWITH
WITHPERSON
PERSONONONDUTY
DUTYAND
ANDAREA
AREAMINIMUM
MINIMUM6m2 6m2
AEON MALL LONG BIEN RENOVATION WORK 2
REGULATION CHECK AEON MALL LONG BIEN – PARKING TOWER EXTENSION

61m
Distance to escape route
Max 80m MALL BUILDING

CONCLUSION:
. ANNEX G-QCVN06-2022 . DISTANCE TO ESCAPE ROUTE REGULATION FORM ANYWHERE OF BUILDING PLAN REQUIREMENT MAX 80m
 CHECKED AND COMPLY WITH THE REGULATION

AEON MALL LONG BIEN RENOVATION WORK 3