2 Piece(s) 1 3/4" X 14" 2.0E Microllam® LVL: Passed

You might also like

You are on page 1of 1

MEMBER REPORT PASSED

Level, Wall: Header 4.2m


2 piece(s) 1 3/4" x 14" 2.0E Microllam® LVL

All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.

Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) System : Wall
72.95 Member Type : Header
Member Reaction (kN) 48.39 @ 277mm Passed (66%) 1.00 1.25 D + 1.5 S + 1.0 L (Adj Spans) Building Use : Residential
(114mm)
Shear (kN) 34.7 @ 4178mm 69.02 Passed (50%) 1.00 1.25 D + 1.5 S + 1.0 L (Adj Spans) Building Code : NBCC 2015
Provincial Code : OBC 2012
Moment (kN-m) 45.72 @ 2434mm 47.07 Passed (97%) 1.00 1.25 D + 1.5 S + 1.0 L (Alt Spans)
Design Methodology : LSD
Live Load Defl. (mm) 11.198 @ 2434mm 11.983 Passed (L/385) -- 1.0 D + 1.0 S + 0.4 W (Alt Spans)
Total Load Defl. (mm) 16.182 @ 2434mm 17.975 Passed (L/267) -- 1.0 D + 1.0 S + 0.4 W (Alt Spans)
• Deflection criteria: LL (L/360) and TL (L/240).
• Overhang deflection criteria: LL (2L/360) and TL (2L/240).
• A 14% decrease in the moment capacity has been added to account for lateral stability.
• A bearing length of 89mm has been used for Point Load Near Support Check.
• The importance category considered for this design is normal.
• The moment, shear, and member reaction values are based on factored loads (strength). Support reactions and deflections are based on unfactored loads (service).

Bearing Length Loads to Supports (kN)

Supports Total Available Required Dead Floor Live Snow Wind Accessories

1 - Trimmer - SPF 114mm 114mm 76mm 11.39 4.89 19.51 19.54 None
2 - Trimmer - SPF 114mm 114mm 76mm 11.39 4.89 19.51 19.54 None

Lateral Bracing Bracing Intervals Comments

Top Edge (Lu) 1200mm o/c


Bottom Edge (Lu) 1200mm o/c

Vertical Loads Location Tributary Width Dead Floor Live Snow Wind Comments

0 - Self Weight (kN/m) 0mm to 4868mm N/A 0.21 -- -- --


1 - Uniform (kPa) 0mm to 4868mm 4000mm 1.12 0.5 2.0 2.0

Shear (kN) Moment (kN-m) Deflection (mm)

Location Analysis Actual Allowed LDF Actual Allowed LDF Live Load Total Comments

1 - 0mm 0.0 69.02 1.00 0.00 35.56 0.65 -2.071 -2.983


2 - 1000mm 28.54 69.02 1.00 25.31 54.71 1.00 5.745 8.300
3 - 2000mm 8.69 69.02 1.00 43.85 54.71 1.00 10.665 15.412
4 - 2400mm 0.75 69.02 1.00 45.71 54.71 1.00 11.195 16.177
5 - 2800mm -7.34 69.02 1.00 44.39 54.71 1.00 10.819 15.633
6 - 3200mm -15.28 69.02 1.00 39.90 54.71 1.00 9.561 13.815
7 - 3600mm -23.22 69.02 1.00 32.23 54.71 1.00 7.504 10.841
8 - 4000mm -31.16 69.02 1.00 21.38 54.71 1.00 4.787 6.915
9 - 4400mm -39.1 69.02 1.00 7.36 54.71 1.00 1.608 2.323
10 - 4800mm 1.35 69.02 1.00 -0.05 54.71 1.00 -1.561 -2.247

ForteWEB Software Operator Job Notes


4/10/2023 2:10:18 PM UTC
Nevin Koshy
Jablonsky, Ast & Partners ForteWEB v3.5, Engine: V8.2.5.1, Data: V8.1.3.6
(416) 824-7480
nkoshy@astint.on.ca File Name: Wall opening
Page 1 / 2

You might also like